Engineering PapersSearch

SEARCH · Engineering Papers

Results for “third-party validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Evaluation of a 5kW Solid Oxide Electrolysis Cell Stack

Solid oxide electrolysis cells (SOECs) are a developing technology for hydrogen production. They are promising due to their utilization of thermal energy to reduce their electricity consumption. The Department of Energy (DOE) has set goals to reduce the price per kilogram of hydrogen, and Idaho National Laboratory (INL) is conducting research to develop and demonstrate advanced methods and technologies to achieve making hydrogen a more affordable, efficient, and sustainable energy source. In this project, INL is collaborating with a vendor to evaluate and validate the design of a 5kW SOEC stack. The test aims to demonstrate a safe startup, operation, and shutdown on INL’s 5kW test stand, providing third-party validation in a different environment. A successful 50-hour test with stable hydrogen production will pave the way for a subsequent 1000-hour test. This project emphasized learning about electrolysis and the various support systems, referred to as balance of plant (BOP) equipment. These systems required modification while swapping to the vendor 5kW SOEC stack, most prominently the furnace door design and the controls system. It also included gaining skills in creating computer-aided design (CAD) drawings for the new door while using available materials and ensuring it met high-temperature requirements. Upon completion of modifications to the test stand, the SOEC will be test-fitted with respective wiring and piping. Instrumentation and piping will be checked for leaks and quality. This must be completed before the vendor’s engineers arrive to observe the test plan, startup, and a collection of 50 hours of data. The vendor’s engineers will ensure their stack performed sufficiently in the 50-hour test to enable the progression to a 1000-hour test.

08 - HYDROGEN

Performance of Quantum Dot Coatings for Luminescent Solar Concentrating Windows: Cooperative Research and Development Final Report, CRADA Number CRD-16-00640

The two major outcomes from this DOE supported collaboration between UbiQD and NREL were: 1) an expert analysis/modeling of the expected performance and cost of luminescent solar concentrating windows with quantum dot coatings, and 2) critical R&D characterization of materials and device performance analysis using equipment and processes that are too expensive for UbiQD to perform in-house. The latter also included third-party validation of the device performance with an NREL-certified conversion efficiency that was ultimately published. (see ACS Energy Lett. 2018 and recently ACS Appl. Energy Mater. 2020).

14 SOLAR ENERGY

Kivalina Biomass Reactor

This report summarizes work performed under DOE Award DE-EE00010149 to support the reliable operation of a community-scale biochar reactor system in Kivalina, Alaska. The project focused on improving sanitation and waste management in a remote community by assessing the installed system, identifying spare parts, defining key performance indicators (KPIs), preparing operator and maintenance manuals, and developing mobile reporting tools for operational data and KPI tracking. The team also produced training materials and recorded videos to support operator onboarding and continuity. The project demonstrated progress in system readiness, documentation, and digital reporting, while also identifying challenges common to remote deployments, including travel constraints, upstream system failures, and local resource limitations. This work provides a practical framework for improving the operation, monitoring, and future replication of biomass reactor systems in remote communities.

09 BIOMASS FUELS

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

It is important for manufacturers of electric vehicle charging connectors, inlets, and adapters to understand the thermal performance of their devices. Various standards, such as SAE J1772, SAE J3400, IEC 62196, UL 2251, and UL 2252, list temperature limits that charging hardware needs to meet. However, there are currently very limited standardized reference devices against which to measure connector performance, and those that do currently exist generally serve charging currents less than 500A. This can make determining whether a charging connector meets the appropriate temperature limits difficult. Additionally, as automakers and charging station suppliers transition from the SAE J1772 CCS charging standard to SAE J3400 NACS, a number of CCS-to-NACS and NACS-to-CCS adapters are entering the market. These devices are being produced both by well-known automakers/equipment OEMs and lesser-known third-party suppliers, across a wide range of price points and construction qualities. Though SAE J3400/1 and UL 2252 lay out standards for adapter construction, performance and overtemperature response, there is no guarantee that any particular adapter will follow these standards and react to overtemperature events appropriately. This work addresses these issues by developing and evaluating a set of CCS and NACS reference inlet devices to validate the performance of charging connectors in the 500-800A range. The work also evaluates the performance of multiple NACS-to-CCS and CCS-to-NACS charging adapters with respect to UL 2252 temperature limits and SAE J3400/1 overtemperature signaling criteria.

33 ADVANCED PROPULSION SYSTEMS

Conflict Detection in Open RAN with Recurrent Neural Networks Using Geometric Manifolds

Allowing third-party applications on Radio Access Network (RAN) Intelligent Controllers (RICs) within the OpenRAN (O-RAN) framework introduces conflicting interactions that are often difficult to detect in advance. These conflicts, occurring between third-party applications in the Near RealTime RIC (Near-RT RIC), known as xApps, can lead to performance degradation and instability in O-RAN if not identified early. Existing conflict detection and mitigation solutions in the literature assume that the conflicts are known beforehand, which is not always accurate due to the complex and often hidden relationships between control parameters and Key Performance Indicators (KPIs). In this paper, we propose a novel Recurrent Neural Network (RNN) to detect both known and unknown conflicts in O-RAN xApps as specified in the O-RAN standards. We model the xApps, control parameters, and KPIs with nodes and edges to create graph structures and use the hidden nonEuclidean geometric properties of the Riemannian manifold to train the RNN model. The performance of this proposed model is validated using evaluation metrics and compared with benchmarks. Results demonstrate that the proposed RNN model, leveraging Riemannian geometric properties, can achieve 100% of the F1-score provided by an optimal solution in just 20 iterations.

5G

Conflict Detection in Open RAN with Recurrent Neural Networks Using Geometric Manifolds

Allowing third-party applications on Radio Access Network (RAN) Intelligent Controllers (RICs) within the OpenRAN (O-RAN) framework introduces conflicting interactions that are often difficult to detect in advance. These conflicts, occurring between third-party applications in the Near RealTime RIC (Near-RT RIC), known as xApps, can lead to performance degradation and instability in O-RAN if not identified early. Existing conflict detection and mitigation solutions in the literature assume that the conflicts are known beforehand, which is not always accurate due to the complex and often hidden relationships between control parameters and Key Performance Indicators (KPIs). In this paper, we propose a novel Recurrent Neural Network (RNN) to detect both known and unknown conflicts in O-RAN xApps as specified in the O-RAN standards. We model the xApps, control parameters, and KPIs with nodes and edges to create graph structures and use the hidden nonEuclidean geometric properties of the Riemannian manifold to train the RNN model. The performance of this proposed model is validated using evaluation metrics and compared with benchmarks. Results demonstrate that the proposed RNN model, leveraging Riemannian geometric properties, can achieve 100% of the F1-score provided by an optimal solution in just 20 iterations.

5G

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI