Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal vacuum chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

GPHS-RTG F5R Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

Solid-state optical refrigerator for cryogenic cooling of payloads

A solid-state optical refrigerator for cryogenic cooling of a payload, the solid-state optical refrigerator including a laser cooling crystal including a first material and a dopant material; a thermal link including a second material, the thermal link being bonded to the laser cooling crystal and the thermal link being configured to be thermally linked to the payload to transfer heat conductively from the payload to the laser cooling crystal via the thermal link; and a vacuum chamber housing the laser cooling crystal and the thermal link, the vacuum chamber and thermal link having a combination of shape and coating such that laser and fluorescence light reflected off a wall of the vacuum chamber and laser and fluorescence light propagating within the thermal link are not incident on the payload.

Hehlen, Markus Peter↗

Beam Induced Heating Analysis Update for the EIC Vacuum Chamber Components

One of the challenges of designing the Electron-Ion Col lider (EIC) is to mitigate beam-induced heating due to the intense electron and hadron beams. Heating of the ESR vac uum chamber components is mainly due to beam-induced resistive wall (RW) losses and synchrotron radiation. For the HSR heating is mainly due to large radial offsets and heat conduction from room temperature to cryogenic tem perature for cryo-components. In this paper, we provide an update on the beam-induced heating and thermal analysis of some critical ESR vacuum chamber components, such as the ESR Large Angle Bremhustraulung Monitor (LABM). We also provide a similar update for critical HSR vacuum com ponents, including the cryo-cooled BPM button assembly, beam screen, abort kicker, and polarimeter. To perform the thermal analyses, the resistive wall loss on individual compo nents is calculated with CST and the synchrotron radiation (if exists) is evaluated using SynRad. These losses, along with realistic boundary conditions are then fed to ANSYS to determine the temperature distribution.

43 PARTICLE ACCELERATORS↗

Development of the materials analysis and particle probe for Proto-MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being used in plasma source research and development (R&D) for the proposed MPEX. Once the R&D is completed, this device can also be used to perform plasma–material interaction studies. To perform these studies, a new materials analysis and particle probe (MAPP) has been constructed. The MAPP’s components are a sample holder and manipulator and a custom vacuum chamber with ports to facilitate surface chemistry diagnostics. The MAPP’s overall design enables rapid sample turnaround and in vacuo surface characterization. The surface analysis vacuum chamber has ports for x-ray photoelectron spectroscopy, thermal desorption spectroscopy, back-scatter ion scattering spectroscopy, forward-scatter ion scattering spectroscopy, and direct recoil spectroscopy. The sample manipulator and holder is a Lesker/UHV Multi-Centre Analytical Stage, which is used to place the samples in the exposure region of the Proto-MPEX or the analysis position in the MAPP vacuum chamber. The sample holder has a heating capability of up to 1200 °C for heated exposure and for desorption studies. In this work, we present the MAPP’s design and the first tungsten sample exposure with ex situ analysis that shows a surface deposition layer on the exposed target, highlighting the need for additional in situ measurements on the Proto-MPEX.

Beers, C. J. (ORCID:0000000150985459)↗

A BEAM SCREEN TO PREPARE THE RHIC VACUUM CHAMBER FOR EIC HADRON BEAMS: CONCEPTUAL DESIGN AND REQUIREMENTS

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will use the existing Relativistic Heavy Ion Collider storage rings, including the superconducting magnet arcs [1]. The vacuum chambers in the superconducting magnets and the cold mass interconnects were not designed for EIC beams and so must be updated to reduce resistive-wall heating and to suppress e-clouds. To do so without compromising the EIC luminosity goal, a stainless steel beam screen with colaminated copper and a thin layer of amorphous carbon will be installed. This paper describes the main requirements that our solution for the hadron ring vacuum chamber needs to satisfy, including impedance, aperture limitations, vacuum, thermal and structural stability, mechanical design, installation and operation. The conceptual design of the beam screen currently under development is introduced.

43 PARTICLE ACCELERATORS↗

Ion-beam-assisted growth of cesium-antimonide photocathodes

We report on the novel use of a Cs+ ion gun for an ion-beam-assisted molecular-beam-epitaxy (IBA-MBE) method to sequentially deposit Cs-Sb cathodes on room temperature substrates as opposed to the standard technique of thermal evaporation on elevated-temperature substrates. The details of the ultrahigh-vacuum chamber, the Cs+ ion source, and the growth technique are elaborated. The final quantum efficiency (QE) is reasonably good for Cs-Sb cathodes grown on two different substrates—Si (100) and strontium titanate—and is comparable to the QE of cathodes grown using thermal sources. This suggests that IBA-MBE could be a viable alternative to grow alkali-antimonides without substrate heating, paving the way for the growth of epitaxial alkali-antimonides in a more reproducible fashion, which may help improve the efficiency of photon detectors and accelerator applications that use alkali-antimonides as electron sources.

Engineering↗

Synthesis of magnesiowüstite nanocrystallites embedded in an amorphous silicate matrix via low energy multiple ion implantations

The synthesis process is presented for experimentally simulating modifications in cosmic dust grains using sequential ion implantations or irradiations followed by thermal annealing. Cosmic silicate dust analogues were prepared via implantation of 20–80 keV Fe - , Mg - , and O - ions into commercially available p-type silicon (100)wafers. The as-implanted analogues are amorphous with a Mg/(Fe+Mg) ratio of 0.5 tailored to match theoretical abundances in circumstellar dusts. Before the ion implantations were performed, Monte-Carlo-based ion-solid interaction codes were used to model the dynamic redistribution of the implanted atoms in the silicon substrate. 600 keV helium ion irradiation was performed on one of the samples before thermal annealing. Two samples were thermally annealed at a temperature appropriate for an M-class stellar wind, 1000 K, for 8.3 h in a vacuum chamber with a pressure of 1 x 10 -7 torr. The elemental depth profiles were extracted utilizing Rutherford Backscattering Spectrometry (RBS) in the samples before and after thermal annealing. X-ray diffraction (XRD)analysis was employed for the identification of various phases in crystalline minerals in the annealed analogues. Transmission electron microscopy (TEM) analysis was utilized to identify specific crystal structures. RBS analysis shows redistribution of the implanted Fe, Mg, and O after thermal annealing due to incorporation into the crystal structures for each sample type. XRD patterns along with TEM analysis showed nanocrystalline Mg and Fe oxides with possible incorporation of additional silicate minerals.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Thermal conductivity of RHIC superconducting magnet insulation materials at low temperatures

The Electron-Ion Collider (EIC) is planned to be built upon the Relativistic Heavy Ion Collider (RHIC), which vacuum chamber will need to be upgraded to host the EIC hadron beams. For the beam pipe section running through the RHIC superconducting (SC) magnets, the baseline is to insert a screen that will get cooled by thermal contact to the 4.55 K beam pipe of RHIC. Knowing the material properties of the cold mass is thus crucial to understand which is the final temperature that the screen and the superconducting coils in the magnets will reach during the passage of the EIC beams. The thermal conductivities of two insulation materials in the RHIC superconducting magnets and a reference material were measured at cryogenic temperatures at the Magnet Science and Technology division of the National High Magnetic Field Laboratory (NHMFL). The measurements were performed in a Quantum Design physical property measurement system. This report explains the motivation behind this work and summarizes the measurement method and results.

43 PARTICLE ACCELERATORS↗

Thermal simulation of the EIC HSR interconnect module - RF fingers

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will reuse most of the existing superconducting magnets from the RHIC storage ring. However, the existing beam vacuum chamber and stripline BPMs will not be compatible with the planned EIC hadron bunches that will have a 3x higher intensity and be 10x shorter, and some operational scenarios with large radial offsets of the beam in the vacuum chamber. To address these challenges, a copper coated beam screen will be implemented, the existing RHIC stripline BPMs will be shielded and an interconnect module design, including new BPM will be installed adjacent to the existing BPMs. A thermal analysis of the new arc BPM interconnect housing has been conducted to assess the heating caused by beam induced resistive wall heating and electron cloud heating. An analysis of the BPM module has been made and reported separately. This report will focus on the other side of the interconnect module, containing the RF fingers.

43 PARTICLE ACCELERATORS↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Design and Study of Inductively Coupled Plasma Chamber Components Using the SupRISE Test Device at DIII-D

The DIII-D National Fusion Facility aims to increase the auxiliary heating power for the tokamak by upgrading the Neutral Beam Injection (NBI) system. In collaboration with North Carolina State University, the conventional ‘arc and filament’ NBI ion sources will be converted to inductively coupled plasma (ICP) sources which utilize radio frequency (RF) coupling to maximize reliability for high power operation. In support of this initiative, a full scale test device (SupRISE, Superior Radiofrequency Ion Source Experiment) is currently under construction at the DIII-D Facility. In preparation for the construction of a full scale prototype that can be installed on the DIII-D NBI system, experiments on SupRISE will be conducted to determine the optimal RF frequency for high power coupling, Faraday shield slit configuration, and ICP chamber length. SupRISE is comprised of an approximately 30 x 70 cm quartz dielectric vessel with an internal Faraday shield enclosed in a secondary vacuum chamber to ensure structural stability of the dielectric. Actively cooled front and back plates are designed to reduce the thermal stresses on the plasma facing components and mate with the existing accelerator used by the NBI system at DIII-D. 50 kW of RF power will be coupled to the plasma through the quartz over a variable frequency range of 4-8 MHz to sustain a plasma density of ∼ 10 18 m −3 for a 10 s ON, 210 s OFF duty cycle. Various modelling efforts have been employed to simulate the thermal and stress profiles over the primary components of the SupRISE device as well as the inductance behavior of the RF antenna. These simulation results and the final design for SupRISE will be presented. An additional reduced-scale predecessor ICP source (called RISE) has been used to develop a predictive match model that will be applied to frequency optimization studies on SupRISE. Furthermore, the outcomes of this research and complementary efforts at North Carolina State University are essential for the incorporation of ICP NBI positive ion sources at the DIII-D facility.

DIII-D↗

Thermal analysis of RHIC arc dipole magnet cold mass with EIC beam screen

The existing RHIC storage rings – including their superconducting magnet arcs – will be used for the hadron storage ring of the Electron-Ion Collider (EIC). The vacuum chamber of these magnets was not designed for the EIC hadron beams, with shorter bunches and of higher average current than the RHIC beams. With the current stainless steel beam pipe, the resistive-wall (RW) heating will exceed the dynamic heat load budget. Limiting the RW heating is important to prevent the superconducting magnets from quenching and to maintain a low screen temperature necessary to impede the rise of RW heating (higher resistance at higher temperature) as well as to achieve desired ultra-high vacuum. In addition, simulations predict the formation of electron cloud which would further contribute to the dynamic heat load and could compromise the quality and stability of the beam. To reduce the resistive-wall heating and suppress electron cloud, a beam screen will be installed in the vacuum chamber of the RHIC SC magnets. The screen will have a high RRR copper layer at its inner face – useful to reduce the resistive-wall impedance thanks to its high conductivity especially at cryogenic temperatures – and will be coated with a thin layer of amorphous carbon, a material with low secondary electron yield to suppress the formation of electron clouds. The baseline solution envisages a screen that will be cooled by thermal contact to the 4.55 K beam pipe. Detailed thermal analysis have been conducted in ANSYS 2020 for an arc dipole cold mass equipped with a beam screen in order to study the feasibility of a passively-cooled screen and guide its design. Temperature-dependent thermal conductivity properties of all materials in the operating (cryogenic) temperature range are considered. Suitable assumptions and simplifications are made to model the magnet coil and calculate its homogenized thermal conductivity. Sensitivity studies with respect to layer thicknesses and area of contact are carried out and results are presented.

43 PARTICLE ACCELERATORS↗

Thermal simulation of the HSR arc BPM Module for EIC

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will reuse most of the existing superconducting magnets from the RHIC storage ring. However, the existing stripline beam position monitors (BPM) used for RHIC will not be compatible with the planned EIC hadron beam parameters that include higher intensity, shorter bunches, and some operational scenarios with large radial offsets of the beam in the vacuum chamber. To address these challenges, the existing RHIC stripline BPMs will be shielded, and a new BPM design using button pick-ups and integrated in a new vacuum interconnect/bellows assembly that will be installed adjacent to the existing BPMs. A thermal analysis of the new arc BPM housing and button pick-up design has been conducted to assess the effects caused by beam induced resistive wall heating and signal propagation through the button pick-up cables for several operational scenarios. This report will describe the analysis results to quantify the heat transfer and temperature distribution that can be expected on the new HSR cryogenic arc BPM housings, button pick-ups, and cryo-signal cables.

43 PARTICLE ACCELERATORS↗

Progress Towards the Reality of Low-Temperature Critical Experiments with Low-Temperature TEX

Integral benchmarks for criticality safety do not exist below room temperature. Incredible support for below room temperature benchmarks is present across the international community. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Similarly, the IAEA, which contains 176 member states, has the same requirement for subcriticality for fissile material transportation. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University. A six-case experiment designed based off the TEX-HEU baseline experiments has been proposed utilizing a chilled vacuum chamber capable of cooling the HEU stack down to -50°C. The six proposed configurations span the entire neutron fission energy range and can be tested at intermediate temperatures between room temperature and -40°C. Of the six configurations, the fastest case utilizes nearly 135 kg of HEU. Understanding the system is required prior to critical experiment operations. In order to test the functionality of the system, testing with surrogate fuel materials has been conducted. The following discusses the design of the low temperature TEX (LT-TEX) experiment as well as the progress made via surrogate testing towards a reality in which low-temperature integral benchmarks exist in the International Criticality Safety Benchmark Evaluation Project (ICSBEP).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of an accelerator-based neutron source to prototype Mo-99 production, Part II: A liquid LBE loop under a high vacuum

To provide US domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. Part I of this work discusses the design of a liquid lead–bismuth eutectic (LBE) windowless target for an accelerator-based neutron source development. Part II discusses how to couple this windowless target to an accelerator operating at an ultra-high vacuum and the subcritical UTA cooled by water at room temperature. Due to the windowless design of the target, the liquid LBE flow shares an ultra-high vacuum (<1.3 × 10 -7 Pa or 10 -9 Torr) space with the accelerator. As a result of this shared vacuum space, the LBE system must operate at a high vacuum (10 -3 ~10 -6 Pa or 10 -5 ~10 -8 Torr). A magnetic rotary motion feedthrough unit utilizes magnetic fluid to allow rotation of the pump while maintaining a high vacuum environment. Prior to testing the LBE system under vacuum, a pump curve measurement is performed to estimate flowrate in the system. This measurement also generates data on orifice loss coefficients, which are compared to correlations in literature. The second experiment investigates vacuum level in the LBE system during operation. High vacuum is maintained (10 -3 ~10 -5 Pa or 10 -5 ~10 -7 Torr) during system operation, and a residual gas analyzer (RGA) scan shows that partial pressures of residual gases in the LBE system lower over the duration of LBE system operations. The third experiment investigates the gravity driven liquid LBE flowing out of the target chamber in the return line, which is partially full. If the liquid LBE is not drained quickly enough, flooding in the target chamber could occur. The coefficient n in the Manning equation is found to be around 0.008 s/m 1/3 . The last experiment performed is a demonstration that a vacuum jacket could provide sufficient thermal insulation to allow coupling between 300 °C LBE loop and a water tank at room temperature. In conclusion, the results from these experiments have influenced the development of the neutron source for the future commercial scale Mo-99 production system.

43 PARTICLE ACCELERATORS↗