Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal response functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

G-Function Library for Modeling Vertical Bore Ground Heat Exchanger

This library contains g-functions (thermal response functions) for standard, regularly spaced vertical borehole ground heat exchangers. In total, it contains 34, 321 configurations. To permit interpolation, each configuration has g-functions for heights of 24, 48, 96, 192, and 384 m. All the g-functions were calculated with burial depths of 2m, and borehole diameters of 15 to 17.5 cm, depending on height. In configurations with uniform spacing, the spacing between the boreholes is set to 5m, though it can be scaled to other horizontal spacings.

15 GEOTHERMAL ENERGY↗

Open library of g-functions for 34,321 configurations

Thermal response functions, known as g-functions, are commonly used in ground heat exchanger design tools and whole building energy simulation programs to simulate the ground heat exchanger performance. Calculation of g-functions can be quite computationally time-consuming, particularly as the number of boreholes gets large. However, once the g-function is computed, the actual simulation time can be quite short, particularly if a hybrid time-step (Cullin and Spitler 2011) approach is used. Because of this, pre-computed g-function libraries are commonly used in design tools and building simulation tools. This paper describes development of a new, publicly available library containing g-functions for 34,321 borehole field configurations; for each configuration, gfunctions are provided for 5 depths to allow interpolation between different borehole-to-height ratios. The available configurations include configurations in standard shapes: lines, rectangles, open rectangles, L-shapes, and U-shapes. It also includes new configurations: C-shapes, lopsided-U-shapes, and zoned rectangles, which are rectangular configurations with different interior and perimeter spacing of the boreholes.

Spitler, Jeffery↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

Electron thermalization and relaxation in laser-heated nickel by few-femtosecond core-level transient absorption spectroscopy

Direct measurements of photoexcited carrier dynamics in nickel are made using few-femtosecond extreme ultraviolet (XUV) transient absorption spectroscopy at the nickel M 2,3 edge. It is observed that the core-level absorption line shape of photoexcited nickel can be described by a Gaussian broadening (σ) and a red shift (ω s ) of the ground-state absorption spectrum. Theory predicts and the experimental results verify that after initial rapid carrier thermalization, the electron temperature increase (ΔT ) is linearly proportional to the Gaussian broadening factor σ, providing quantitative real-time tracking of the relaxation of the electron temperature. Measurements reveal an electron cooling time for 50 nm thick polycrystalline nickel films of 640 ± 80 fs. With hot thermalized carriers, the spectral red shift exhibits a power-law relationship with the change in electron temperature of ω s ∝ ΔT 1.5 . Rapid electron thermalization via carrier-carrier scattering accompanies and follows the nominal 4-fs photoexcitation pulse until the carriers reach a quasithermal equilibrium. Entwined with a <6 fs instrument response function, carrier thermalization times ranging from 34 fs to 13 fs are estimated from experimental data acquired at different pump fluences and it is observed that the electron thermalization time decreases with increasing pump fluence. Here, the study provides an initial example of measuring electron temperature and thermalization in metals in real time with XUV light, and it lays a foundation for further investigation of photoinduced phase transitions and carrier transport in metals with core-level absorption spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical Actuation via Homeomorphic Transformations of Topological Solitons within Polymer Coatings

Abstract Topological solitons are currently under investigation for their exotic properties, especially in nonlinear physics, optics, and material sciences. However, challenges of robust generation and limited stability over time have hindered their practical uses. To address this issue, an approach is developed to form structured arrays of solitons in films of polymerizable liquid crystals. Their complex molecular architecture is preserved by in situ photopolymerization forming a stable liquid crystal network. Most excitingly, their properties are advanced to include responsiveness functions. When thermally actuated, these topological solitons mediate the reconfiguration of surface topographies. Complex shape changes occur depending on the intrinsic complex spatial distribution of the director, which may even lead to full shape inversion and topographical changes as high as ≈40% of the initial thickness. Conversely, the shape changes provide information on the initial director profile, which is consistent with the mathematical model. The soliton‐containing polymer coatings are applicable in multiple domains, ranging from tunable optics to haptics, and from shape‐coupled sensing systems to temperature‐coupled heat management.

36 MATERIALS SCIENCE↗

Thermal responses of dissolved organic matter under global change

The diversity of intrinsic traits of different organic matter molecules makes it challenging to predict how they, and therefore the global carbon cycle, will respond to climate change. Here we develop an indicator of compositional-level environmental response for dissolved organic matter to quantify the aggregated response of individual molecules that positively and negatively associate with warming. We apply the indicator to assess the thermal response of sediment dissolved organic matter in 480 aquatic microcosms along nutrient gradients on three Eurasian mountainsides. Organic molecules consistently respond to temperature change within and across contrasting climate zones. At a compositional level, dissolved organic matter in warmer sites has a stronger thermal response and shows functional reorganization towards molecules with lower thermodynamic favorability for microbial decomposition. The thermal response is more sensitive to warming at higher nutrients, with increased sensitivity of up to 22% for each additional 1 mg L -1 of nitrogen loading. The utility of the thermal response indicator is further confirmed by laboratory experiments and reveals its positive links to greenhouse gas emissions.

54 ENVIRONMENTAL SCIENCES↗

Parallelized Quadrupole Simulations of Thermographic Responses of Composites

Thermography has been shown to be a viable technique for inspection of composites. Model inversion of the thermography data requires a fast method for performing the forward problem. Viable numerical methods for the thermal response forward problem are finite element, finite difference and the quadrupole method. Normally both the finite element and finite difference methods solve for the thermal response in the time domain which limits one’s ability to increase the speed of the simulation by parallelization. In contrast, the quadrupole method solves for the Laplace transform of the thermal response. One of the features of the Laplace transform methodology is the solution at any discrete time is independent of the solution at all other times. Therefore, it is easy to separate into a set of independent calculations with each of the times of interest being performed in parallel. Additionally, the numeric inversion of the Laplace transform typically involves numerically solving for the Laplace transform at multiple Laplace frequencies. Each of those solutions are also independent of solutions at other frequencies and can be calculated in parallel. By parallelization of this method, it is possible to perform the simulations of three-dimensional configurations in seconds. When the input stimulus for thermal response is a delta function heat flux (a reasonable approximation for flash heating), the thermal response is smooth. For this case, it is possible to accurately estimate the thermal response at any time within a given time interval from a set of simulations separated by exponentially increasing time steps. From these simulations, it is possible to accurately interpolate to find the response at intermediate times by a spline interpolation of the logarithm of time versus logarithm of temperature. The thermal response with exponential time stepping is shown to produce values for the thermal response which are within 1% of values within the time interval. The simulations are compared to finite element simulations of the same inspection configurations. The simulations are also compared to the thermographic measurements on composites where shape and depth of the delaminations are obtained from other inspection methods.

Thermography↗

Parallelized Quadrupole Simulations of Thermographic Responses of Composites

Thermography has been shown to be a viable technique for inspection of composites. Model inversion of the thermography data requires a fast method for performing the forward problem. Viable numerical methods for the thermal response forward problem are finite element, finite difference and the quadrupole method. Normally both the finite element and finite difference methods solve for the thermal response in the time domain which limits one’s ability to increase the speed of the simulation by parallelization. In contrast, the quadrupole method solves for the Laplace transform of the thermal response. One of the features of the Laplace transform methodology is the solution at any discrete time is independent of the solution at all other times. Therefore, it is easy to separate into a set of independent calculations with each of the times of interest being performed in parallel. Additionally, the numeric inversion of the Laplace transform typically involves numerically solving for the Laplace transform at multiple Laplace frequencies. Each of those solutions are also independent of solutions at other frequencies and can be calculated in parallel. By parallelization of this method, it is possible to perform the simulations of three-dimensional configurations in seconds. When the input stimulus for thermal response is a delta function heat flux (a reasonable approximation for flash heating), the thermal response is smooth. For this case, it is possible to accurately estimate the thermal response at any time within a given time interval from a set of simulations separated by exponentially increasing time steps. From these simulations, it is possible to accurately interpolate to find the response at intermediate times by a spline interpolation of the logarithm of time versus logarithm of temperature. The thermal response with exponential time stepping is shown to produce values for the thermal response which are within 1% of values within the time interval. The simulations are compared to finite element simulations of the same inspection configurations. The simulations are also compared to the thermographic measurements on composites where shape and depth of the delaminations are obtained from other inspection methods.

Thermography↗

Characterization of the thermal conductivity for Advanced Toughened Uni-piece Fibrous Insulations

Advanced Toughened Uni-piece Fibrous Insulations (TUFI) is discussed in terms of their thermal response to an arc-jet air stream. A modification of the existing Ames thermal conductivity program to predict the thermal response of these functionally gradient materials is described in the paper. The modified program was used to evaluate the effect of density, surface porosity, and density gradient through the TUFI materials on the thermal response of these insulations. Predictions using a finite-difference code and calculated thermal conductivity values from the modified program were compared with in-depth temperature measurements taken from TUFI insulations during short exposures to arc-jet hypersonic air streams.

Stewart, David A.↗

Development of New g-function Data for Simulating a Novel Shallow Bore Ground Heat Exchanger

Geothermal heat pump (GHP), which is also referred as ground source heat pump, is the most energy-efficient technology for space heating and cooling. However, the application of GHP is hindered by its high initial cost, of which approximately 30% is for the ground heat exchanger (GHE). In recent years, researchers have developed different types of shallow bore ground heat exchangers (SBGHE) intending to reduce the cost of drilling. The ability to predict the thermal response of an SBGHE is critical for sizing SBGHE. While g-functions have been commonly used for predicting the thermal response of conventional vertical bore ground heat exchangers (VBGHE), they cannot be directly used for predicting the performance of SBGHE because they did not account for the impacts of the seasonal variation of the soil temperature along with the depth of an SBGHE. In addition, an SBGHE has a larger thermal mass within the borehole than the VBGHE due to the larger borehole diameter of SBGHE. This study develops new g-function data pairs for a new design of SBGHE, which is named Underground Thermal Battery (UTB). Impacts of the seasonal variation of soil temperature on the thermal response of UTB were accounted for by superposing a time-dependent soil temperature onto the g-functions calculated with a numerical model that assumes constant undisturbed soil temperature. The TOUGH program was used to predict the thermal response of several configurations involving multiple UTBs. The results indicate that the proposed methodology is appropriate to generate g-functions for the UTB, and the g-function value of UTB is much lower than that of VBGHE in the time range of 15 min to 1 year due to the large thermal mass and convection heat transfer within the UTB.

Shi, Liang↗

Parametric Study of an Ablative TPS and Hot Structure Heatshield for a Mars Entry Capsule Vehicle

The National Aeronautics and Space Administration is planning to send humans to Mars. As part of the Evolvable Mars Campaign, different en- try vehicle configurations are being designed and considered for delivering larger payloads than have been previously sent to the surface of Mars. Mass and packing volume are driving factors in the vehicle design, and the thermal protection for planetary entry is an area in which advances in technology can offer potential mass and volume savings. The feasibility and potential benefits of a carbon-carbon hot structure concept for a Mars entry vehicle is explored in this paper. The windward heat shield of a capsule design is assessed for the hot structure concept as well as an ablative thermal protection system (TPS) attached to a honeycomb sandwich structure. Independent thermal and structural analyses are performed to determine the minimum mass design. The analyses are repeated for a range of design parameters, which include the trajectory, vehicle size, and payload. Polynomial response functions are created from the analysis results to study the capsule mass with respect to the design parameters. Results from the polynomial response functions created from the thermal and structural analyses indicate that the mass of the capsule was higher for the hot structure concept as compared to the ablative TPS for the parameter space considered in this study.

Langston, Sarah L.↗

Fit-free optical determination of electronic thermalization time in nematic iron-based superconductors

We present a nematic response function model (NRFM) for fit-free direct extraction of the characteristic time of ultrafast electronic thermalization in iron-based superconductors, materials with electronic nematicity. By combining the NRFM for polarization-dependent pump–probe measurements of electronic nematic response with the two-temperature model (TTM) for sub-picosecond quasiparticle relaxation, we quantify the electronic thermalization timescales and their anisotropy. The nematic response function is modeled as the difference in normalized reflectivity signals, revealing a pronounced sub-picosecond extremum in signal evolution that directly yields the characteristic electronic thermalization time. This method demonstrates that the NRFM is consistent with TTM fits of transient optical response, yielding electronic thermalization time constants on the order of 110–230 fs for the FeSe 1−x Te x and Ba(Fe 0.92 Co 0.08 ) 2 As 2 thin films. Here, the proposed approach can be applied to any material that exhibits electronic nematicity, providing a powerful tool for direct mapping of the relaxation time in nematic materials, avoiding complex experimental data-fitting procedures.

Bartenev, Alexander [University of Puerto Rico, Ma↗

Linear dynamic analysis of the Space Station Freedom thermal/environmental control system

A methodology for dynamic analysis of the Space Station Freedom thermal/environmental control system is described which uses linear system analysis techniques to determine the ability of the system to accommodate thermal load transients. A nonlinear integrated model of the system as it exists at Stage 6, Man Tended Capability (MTC), is described which encompasses the cabin air cooling system, avionics air cooling system, internal and external thermal control systems. The nonlinear model is linearized at an assumed design operating point, and the linear model is evaluated by comparison with the nonlinear model. Transfer functions are derived to determine the response of the heat rejection system to time-varying thermal loads applied at various points in the heat acquisition system. The frequency response calculated from the transfer functions is used to determine allowable operating envelopes of thermal load magnitude and frequency for each point of application of thermal load. The dynamic operating envelopes provide a quantitative indication of the degree and duration of peak loads which the thermal/environmental system is able to transport and reject.

Tandler, John↗

Comparison of Dynamic Characteristics for an Inflatable Solar Concentrator in Atmospheric and Thermal Vacuum Conditions

Dynamic testing of an inflatable solar concentrator structure in a thermal vacuum chamber as well as in ambient laboratory conditions is described in detail. Unique aspects of modal testing for the extremely lightweight inflatable are identified, including the use of a noncontacting laser vibrometer measurement system. For the thermal vacuum environment, mode shapes and frequency response functions are compared for three different test article inflation pressures at room temperature. Modes that persist through all the inflation pressure regimes are identified, as well as modes that are unique for each pressure. In atmospheric pressure and room temperature conditions, dynamic measurements were obtained for the expected operational inflation pressure of 0.5 psig. Experimental mode shapes and frequency response functions for ambient conditions are described and compared to the 0.5 psig results from the thermal vacuum tests. Only a few mode shapes were identified that occurred in both vacuum and atmospheric environments. This somewhat surprising result is discussed in detail, and attributed at least partly to 1.) large differences in modal damping, and 2.) significant differences in the mass of air contained by the structure, in the two environments. Results of this investigation point out the necessity of testing inflatable space structures in vacuum conditions before they can be launched. Ground testing in atmospheric pressure is not sufficient for predicting on-orbit dynamics of non-rigidized inflatable systems.

Slade, Kara N.↗

Atomic faulting drives exceptional toughness in low thermal expansion chromium alloys

Endowing functional properties with mechanical responses in traditional metals has been a frontier topic, akin to transforming base metal into gold. Chromium and its alloys, with their functional deficiencies and limited ductility, serve as typical examples. Herein, we report a Cr96Fe4Ge1.3B1 alloy that unifies low thermal expansion (LTE, αl = 1.79 × 10-6 K-1, 200 − 315 K) with exceptional toughness (240.2 J·cm-3). The enhancement in mechanical responses is primarily attributed to layered Cr2B intermetallic precipitates, which ameliorate interfacial cohesion and simultaneously refine the grain structure. The weakened interlayer interactions within the Cr-B layers facilitate the nucleation and movement of numerous tiny stacking faults in precipitates, efficiently alleviating strain energy and resulting in marked work-hardening ability. Additionally, antiferromagnetic fluctuations in the BCC matrix contribute to the unique LTE behavior. This paves the way for the design of high-performance alloys featuring layered-symmetry precipitates.

Yu, Chengyi [University of Science and Technology ↗

Microgravity fluid management in two-phase thermal systems

Initial studies have indicated that in comparison to an all liquid single phase system, a two-phase liquid/vapor thermal control system requires significantly lower pumping power, demonstrates more isothermal control characteristics, and allows greater operational flexibility in heat load placement. As a function of JSC's Work Package responsibility for thermal management of space station equipment external to the pressurized modules, prototype development programs were initiated on the Two-Phase Thermal Bus System (TBS) and the Space Erectable Radiator System (SERS). JSC currently has several programs underway to enhance the understanding of two-phase fluid flow characteristics. The objective of one of these programs (sponsored by the Microgravity Science and Applications Division at NASA-Headquarters) is to design, fabricate, and fly a two-phase flow regime mapping experiment in the Shuttle vehicle mid-deck. Another program, sponsored by OAST, involves the testing of a two-phase thermal transport loop aboard the KC-135 reduced gravity aircraft to identify system implications of pressure drop variation as a function of the flow quality and flow regime present in a representative thermal system.

Parish, Richard C.↗