Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal management systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Oscillating heat pipe integrated thermal management system for power electronics

Disclosed is a thermal management system for removing heat from a power electronic heat source, the system comprising: a base plate having a plurality of fluid passages there through and extending between and inlet side of the base plate and an outlet side of the base plate; and a plurality of heat transfer pipe segments respectively attached to one or more of the plurality of fluid passages at the inlet side of the base plate and the outlet side of the base plate, the plurality of heat transfer pipe segments arranged adjacent one another, the plurality of heat transfer pipe segments containing a two-phase working fluid, and the plurality of heat transfer pipe segments forming a continuous flow path through and back into the base plate for the two-phase working fluid.

Wang, Jim↗

Thermal Management System for an Electric Machine With Additively Manufactured Hollow Conductors With Integrated Heat Pipes

Here, this paper discusses steps taken to develop a novel thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal finite element analysis is used to determine optimum heat transfer coefficient of the convective boundaries. For some of the convective boundaries, fin-based surface area enhancement is required to reach a target combined overall heat transfer coefficient and surface area performance (UA). This enhancement is worked out using a combination of the Engineering Equation Solver tool and 3D thermal FEA. The thermal management system's UA, and by extension its specific power, sensitivity to coolant temperature is explored. Temperature distribution plots of optimized machine components are also presented and discussed. Lastly, additional heat pipe testing is carried out to study its maximum heat transfer capability's sensitivity to condenser coolant temperature and configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative analysis of thermal management systems in electric vehicles at extreme weather conditions: Case study on Nissan Leaf 2019 Plus, Chevrolet Bolt 2020 and Tesla Model 3 2020

With the surge in electric vehicle (EV) adoption and the need for extended driving ranges, optimizing energy efficiency, particularly through thermal management, is critical, especially in extreme weather. Managing the substantial energy needed for cabin climate control and battery temperature regulation can increase energy demands by over 50 %, severely limiting range. This study conducts a comparative analysis of thermal management systems (TMS) in three popular EV vehicles, 2020 Chevrolet Bolt, 2019 Nissan Leaf Plus, and 2020 Tesla Model 3, evaluating their distinct TMS configurations and performance under varied weather conditions. Using both numerical simulations and experimental data collected on a controlled test bench at Argonne National Laboratory, we assess how TMS architecture and operational modes influence energy consumption and range. A comprehensive TMS model was developed, integrating cabin and battery thermal sub-models in the Autonomie software platform, to simulate temperature fluctuations and range impacts. Cabin climate was modeled using a mono-zonal approach, while battery cell temperature distribution was estimated through a 2D nodal structure. Each vehicle's distinct TMS setup was evaluated: the Chevrolet Bolt and Tesla Model 3 use a dual evaporator vapor compression cycle with a PTC heater for the cabin and a coolant loop for battery thermal management; the Nissan Leaf Plus employs a heat pump with a PTC heater for the cabin and air-cooling for the battery. Tests conducted at ambient temperatures of 35°C, 22°C, -7°C, and -18°C reveal significant differences in energy use and range reduction across both configurations and conditions. At 35°C, the Tesla Model 3, Chevrolet Bolt, and Nissan Leaf Plus have a range reduction of 8%, 9%, and 13%, respectively, due to air conditioning. In winter, heating technology is paramount; at -7°C, the Nissan Leaf's heat pump configuration achieves a lower range reduction (19.3%) compared to the Tesla and Chevrolet Bolt PTC heaters, which reduce range by 28.3% and 31%, respectively. Further, this study provides valuable insights for automotive engineers, EV technology researchers, and thermal management system designers aiming to enhance electric vehicle performance by understanding how different weather conditions and TMS architectures impact energy consumption and driving range.

33 ADVANCED PROPULSION SYSTEMS↗

Heat Pipe Enhanced Thermal Management System for GaN Switches in an Integrated Modular Motor Drive for Aircraft Propulsion

This paper presents the process of sizing a heat pipe enhanced thermal management system (TMS) for GaN switches in an integrated modular motor drive (IMMD) powering a 250 kW aircraft propulsion electric motor. A test setup mimicking the TMS and GaN switches assembly is constructed. The condenser chamber of the TMS is modeled in ANSYS Fluent while the GaN switches assembly is modeled in ANSYS Thermal allowing us to verify heat spreader temperature under test conditions and estimate GaN temperatures under test and actual application operating conditions.

DIRECT ENERGY CONVERSION↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

Cooling charge determination for a local thermal management system

A system and method for estimating the state of charge, i.e., the amount of cooling remaining, in a latent heat thermal storage module of a local environmental control system. The local environmental control system stores cooling energy at night by freezing a latent heat phase change material (PCM), and then releasing the stored cooling energy by removing heat from room air flowing through the PCM during the day. Differential temperature sensors are used measure the air temperature drop across the latent thermals storage unit and the fan voltage, which is directly related to fan air flow rate, is sampled. A controller is programmed to determine the charging state from these measurements.

Khalifa, H. Ezzat↗

Safety Hazards of Batteries and Hydrogen Storage Systems in Proximity

This report addresses the safety concerns and mitigations for battery failures and their impact on hydrogen storage systems. Through an analysis of failure modes, this report highlights the risks posed by thermal runaway and chemical emissions caused by batteries. Although rare, battery thermal failure events may prompt the opening of the relief valve on the hydrogen tank. Strategies such as battery management systems, thermal management systems, and multiple thermally activated pressure relief devices can mitigate these risks. Potential simulations and experiments to better quantify the unique risks posed by lithium-ion batteries near tanks are suggested. Improving safety standards will enable integration of batteries and hydrogen storage systems in various energy storage technologies.

08 HYDROGEN↗

Li-Ion Battery Thermal Characterization for Thermal Management Design

Battery design efforts often prioritize enhancing the energy density of the active materials and their utilization. However, optimizing thermal management systems at both the cell and pack levels is also key to achieving mission-relevant battery design. Battery thermal management systems, responsible for managing the thermal profile of battery cells, are crucial for balancing the trade-offs between battery performance and lifetime. Designing such systems requires accounting for the multitude of heat sources within battery cells and packs. This paper provides a summary of heat generation characterizations observed in several commercial Li-ion battery cells using isothermal battery calorimetry. The primary focus is on assessing the impact of temperatures, C-rates, and formation cycles. Moreover, a module-level characterization demonstrated the significant additional heat generated by module interconnects. Characterizing heat signatures at each level helps inform manufacturing at the design, production, and characterization phases that might otherwise go unaccounted for at the full pack level. Further testing of a 5 kWh battery pack revealed that a considerable temperature non-uniformity may arise due to inefficient cooling arrangements. To mitigate this type of challenge, a combined thermal characterization and multi-domain modeling approach is proposed, offering a solution without the need for constructing a costly module prototype.

25 ENERGY STORAGE↗

Actively controlled coolant tank to increase thermal storage capacity of hybrid electric vehicles

An engine and cabin thermal management system for use with a vehicle having an engine, a cabin heating system configured to thermally heat a cabin of the vehicle, a coolant system operably coupled to the engine and to the cabin heating system to thermally manage a temperature of the engine and a temperature of the cabin. The coolant system having one or more coolant thermal storage units fluidly coupled with a radiator and heater core of the coolant system forming a coolant loop. The system further having a control system configured to monitor and maintain at least a predetermined coolant temperature at the cabin heating system even during a coolant temperature decrease at the engine stops.

Amini, Mohammad Reza↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

A Comprehensive Numerical and Experimental Study for the Passive Thermal Management in Battery Modules and Packs

Cooling plates in battery packs of electric vehicles play critical roles in passive thermal management systems to reduce risks of catastrophic thermal runaway. In this work, a series of numerical simulations and experiments are carried out to unveil the role of cooling plates (both between cells and a bottom plate parallel to the cell stack) on the thermal behavior of battery modules and packs under nail penetrations. First, we investigated the role of side cooling plates on the thermal runaway propagation mitigation in battery modules (1S3P) and packs (3S3P) by varying the key parameters of the side cooling plates, such as plate thicknesses, thermal contact resistances, and materials. Then, three important factors for passive thermal management systems are identified: (i) thermal mass of side cooling plates, (ii) interfacial thermal contact resistances, and (iii) the effective heat transfer coefficients at exterior surfaces. The roles of bottom cooling plates on thermal runaway propagation mitigation in 1S3P and 1S5P battery modules are numerically investigated by comparing the thermal behavior of the modules with only side cooling plates and with both side and bottom cooling plates.

25 ENERGY STORAGE↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor (CFC)

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. They can also be used in modular designs, affording even more flexibility for potential deployment. In addition to the aerogel adsorbent within the blanket material, a CFC includes thermally-conductive membrane layered with the aerogel, which acts as a large-area, quick-response thermal management system. The system conducts heat throughout the volume to discharge the unit quickly. This same thermal management system can also be connected to a refrigeration system, or cold fluid such as liquid nitrogen (LN2), to facilitate the charging up of the CFC. The charging and discharging can be performed as fast or as slow as desired by controlling the cooling or heating supplied to the CFC.

08 HYDROGEN↗