Year-Round Experimental Demonstration of a Thermal Energy Storage–Integrated Heat Pump for Space Cooling and Heating Load Shifting
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.
The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.
This material will be presented at the Interagency Advanced Power Group (IAPG) Chemical Working Group and Safety Panel Meeting. IAPG serves as the premier organization coordinating the collaboration and information exchange of advanced power research and development within the U.S. government.
The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.
In a nuclear reactor, prolonged exposure to high neutron flux levels can change material properties of reactor components. Due to the danger posed to personnel by highly radioactive components such as spent fuel, noncontact methods must be used to determine these properties. The objective of the current research is to test the viability of using a flash-heating method to determine the thermal diffusivity of a silicon carbide (SiC) tube, which could be used as cladding for a nuclear fuel rod. The flash-heating experiment was conducted at Oak Ridge National Laboratory and temperature results were analyzed as a two-Dimensional cross section which assumed axial symmetry. The model was fitted iteratively to the temperature measurements using nonlinear regression which required values for thermal diffusivity, Biot number and a term to determine the magnitude of the heat absorbed by the flash. The method could be expanded in the future to estimate the thermal diffusivity of spent nuclear fuel rods in an effort to increase the certainty of new reactor designs using precise thermal properties throughout the core life. A statistical analysis of the results of this work is provided as part of the analysis.
The integration of solar thermal systems with chemical reactors has been proposed as part of a larger effort to develop and deploy solar heat for industrial processes (SHIP) technologies. A strong motivation for SHIP processes and technologies is the potential for high thermal efficiency coupled with low-cost thermal energy storage (TES) which can enable commercial deployment of such systems. While there are different ways to categorize SHIP technologies, one important such distinction is between directly irradiated systems and indirect off-sun process driven by a SHIP system. While directly irradiated systems can provide high thermal efficiencies and high fluxes, they usually require complex engineering solutions due to the need for redesigning the established processes and unit operations. In most cases, it is also more challenging to couple such a process to a TES system, losing some of the benefits of SHIP. On the other hand, using a SHIP system to drive an industrial process off-sun can allow better integration with existing process chains, easier TES capabilities, and potential for more applications fitting a specific SHIP technology. However, the integration of SHIP systems with the industrial processes is not fully explored in detail, especially in the case of high-temperature processes such as reforming, cracking, cement manufacturing, and iron/steelmaking. Many of these systems require heating fluxes of >50 kW/m^2, supplied via combustion of hydrocarbons in a fire box and benefitting from radiative heat transfer between the flue gases and the reaction zones. As such, using SHIP systems for such processes is more complex than providing the same thermal input in the form of a heat transfer medium (HTM) entering the reactor, kiln, or furnace. Moreover, in case convective heat transfer using SHIP is envisioned, for example using supercritical CO2 as the HTM from a particle receiver, the thermal integration might be more challenging than initially envisioned: lower heat transfer coefficients and limited approach temperature might require large flow rates, causing a mismatch between the process thermal requirements and the thermal capacity of the SHIP system. In addition, even if the heat exchange between SHIP and reactor is effective, there is still a cold leg HTM at the reaction temperature or slightly below it. Chemical plants usually include a set of heat exchangers, heat recovery steam generators, and even power generation units - in a tightly integrated design - to recover the flue gases which are eventually vented. With SHIP systems mostly operating on a closed HTM loop, bottoming the cold leg is crucial. In this talk, we will present different modeling results for a variety of syngas production reactions, using catalytic and chemical looping processes, and discuss some of the challenges and design considerations for off-sun chemical reactors using SHIP systems.
This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.
Steady-state quantum thermal machines are typically characterized by a continuous flow of heat between different reservoirs. However, at the level of discrete stochastic realizations, heat flow is unraveled as a series of abrupt quantum jumps, each representing an exchange of finite quanta with the environment. Here, in this work, we present a framework that resolves the dynamics of quantum thermal machines into cycles classified as enginelike, coolinglike, or idle. We analyze the statistics of individual cycle types and their durations, enabling us to determine both the fraction of cycles useful for thermodynamic tasks and the average waiting time between cycles of a given type. Central to our analysis is the notion of intermittency, which captures the operational consistency of the machine by assessing the frequency and distribution of idle cycles. Our framework offers a novel approach to characterizing thermal machines, with significant relevance to experiments involving mesoscopic transport through quantum dots.
The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.
In recent history, extreme heat has been the cause of most deaths from a natural disaster. Exposure to extreme heat can aggravate preexisting conditions, increase hospitalization, and even cause death. Thus, modeling the thermal resilience of households across the United States will allow for a quantitative assessment of the health and safety risks posed by extreme heat. For the first time, we simulate occupant comfort in representative households across Boston by combining the granular results of the ResStock(TM) model with a two-node heat strain model. This model calculates occupants' core body temperature in each simulated household over a year. We compare the simulated core temperatures to two public health metrics: hyperthermia and heat stroke. Our results show for households in Boston that do not have or use aid conditioning, thousands potentially experience many dangerous heat events each summer and these events can last for more than a day at a time. These heat events peak during the late afternoon and evening, just as residents are coming home, cooking meals, and trying to go to sleep. We have found that multi-family buildings, renters, and low-income homes in more airtight and insulated homes are the most at risk for these events. These results demonstrate the scale and urgency of exposure to extreme heat.
Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.
A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.
Interfacial thermal and acoustic phenomena have an important role in quantum science and technology, including in spintronic and spincaloritronic materials and devices. Simultaneous measurements of the low-temperature thermal and acoustic properties of a metal/insulator heterostructure reveal distinct dynamics in the characteristic phonon frequency ranges of acoustic and thermal transport. The measurements probed a heterostructure consisting of a thin film of Pt on the ferrimagnetic insulator gadolinium iron garnet (Gd 3 Fe 5 O 12 , GdIG) grown epitaxially on a gadolinium gallium garnet substrate. Ultrafast structural dynamics within the Pt layer were tracked using time-resolved ultrafast x-ray diffraction and analyzed to probe interfacial acoustic and thermal properties. The rapid heating of the Pt layer by a 400 nm wavelength femtosecond-duration optical pulse produced transient structural changes that provided the stimulus for these measurements. Rapid heating produced a broadband acoustic pulse that was partially reflected by the Pt/GdIG interface. Temporal frequencies up to 740 GHz, corresponding to angular frequencies of several THz, were detected in a wavelet analysis of the acoustic oscillations of the strain in the Pt layer. The structural results were analyzed to determine (i) the acoustic damping coefficient and phonon mean free path in Pt at frequencies of hundreds of GHz and (ii) the Grüneisen anharmonicity parameter. The thermal conductance of the Pt/GdIG interface was tracked using the slower, tens-of-picosecond-scale, dynamics of the initial cooling of the heated Pt layer. Analysis using a model based on the Boltzmann transport equation shows that the phonon transmission is lower at the phonon frequencies relevant to thermal transport than for subterahertz regime acoustics.
Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.
In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.
Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.
Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity