Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “texture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Texture analysis of AGR program matrix materials

We report the fuel form for high-temperature gas-cooled reactors consists of tristructural isotropic (TRISO) particles embedded in a matrix of graphite flake and carbonized resin. The process of overcoating particles prior to compacting yields a circumferential orientation of the graphite flake surrounding the TRISO particles, which is modified to varied extents when overcoated particles are pressed into the final fuel form. As graphite is highly anisotropic, the texture may impact the properties and performance of the fuel. Ellipsometry was used to measure the texture of the matrix for fueled compacts and unfueled “matrix-only” samples. Results indicated local texture related to the spherical particles in compacts associated with overcoating versus a more linear layered structure in “matrix-only” samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diffraction Methods for Qualitative and Quantitative Texture Analysis of Ferroelectric Ceramics

Crystallographic textures are pervasive in ferroelectrics and underpin the functional properties of devices utilizing these materials because many macroscopic properties (e.g., piezoelectricity) require a non-random distribution of dipoles. Inducing a preferred grain texture has become a viable route to improve these functional properties. X-ray and neutron diffraction have become valuable tools to probe crystallographic textures. This paper presents an overview of qualitative and quantitative methods for assessing crystallographic textures in electroceramics (domain and grain textures) and discusses their strengths and weaknesses.

36 MATERIALS SCIENCE↗

Texture measurements on quartz single crystals to validate coordinate systems for neutron time-of-flight texture analysis

In crystallographic texture analysis, ensuring that sample directions are preserved from experiment to the resulting orientation distribution is crucial to obtain physical meaning from diffraction data. This work details a procedure to ensure instrument and sample coordinates are consistent when analyzing diffraction data with a Rietveld refinement using the texture analysis software MAUD . A quartz crystal is measured on the HIPPO diffractometer at Los Alamos National Laboratory for this purpose. The methods described here can be applied to any diffraction instrument measuring orientation distributions in polycrystalline materials.

36 MATERIALS SCIENCE↗

Breast Cancer Risk Estimation Using Parenchymal Texture Analysis in Digital Breast Tomosynthesis

Mammographic parenchymal texture has been shown to correlate with genetic markers of developing breast cancer. Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique in which tomographic images of the breast are reconstructed from multiple source projections acquired at different angles of the x-ray tube. Compared to digital mammography (DM), DBT eliminates breast tissue overlap, offering superior parenchymal tissue visualization. We hypothesize that texture analysis in DBT could potentially provide a better assessment of parenchymal texture and ultimately result in more accurate assessment of breast cancer risk. As a first step towards validating this hypothesis, we investigated the association between DBT parenchymal texture and breast percent density (PD), a known breast cancer risk factor, and compared it to DM. Bilateral DBT and DM images from 71 women participating in a breast cancer screening trial were analyzed. Filtered-backprojection was used to reconstruct DBT tomographic planes in 1 mm increments with 0.22 mm in-plane resolution. Corresponding DM images were acquired at 0.1 mm pixel resolution. Retroareolar regions of interest (ROIs) equivalent to 2.5 cm{sup 3} were segmented from the DBT images and corresponding 2.5 cm{sup 2} ROIs were segmented from the DM images. Breast PD was mammographically estimated using the Cumulus scale. Overall, DBT texture features demonstrated a stronger correlation than DM to PD. The Pearson correlation coefficients for DBT were r = 0.40 (p<0.001) for contrast and r = -0.52 (p<0.001) for homogeneity; the corresponding DM correlations were r = 0.26 (p = 0.002) and r = -0.33 (p<0.001). Multiple linear regression of the texture features versus breast PD also demonstrated significantly stronger associations in DBT (R{sup 2} = 0.39) compared to DM (R{sup 2} = 0.33). We attribute these observations to the superior parenchymal tissue visualization in DBT. Our study is the first to perform DBT texture analysis in a screening population of women, showing that DBT could potentially provide better breast cancer risk assessment in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Therapy Response to Transarterial Radioembolization for Liver Metastases by Means of Post-treatment MRI-Based Texture Analysis

IntroductionTo determine whether post-treatment magnetic resonance imaging (MRI)-based texture analysis of liver metastases (LM) may be suited predicting therapy response to transarterial radioembolization (TARE) during follow-up.Materials and MethodsThirty-seven patients with LM treated by TARE (mean age 63.4 years) between January 2006 and December 2014 were identified in this retrospective feasibility study. They underwent dynamic contrast-enhanced and hepatocellular phase MRI after TARE (mean 2.2 days). Response was evaluated on follow-up imaging scheduled in intervals of 3 months (median follow-up, 7.3 months) based on response evaluation criteria in solid tumors 1.1 (RECIST 1.1). Results of texture analysis [mean, standard deviation, skewness (s), kurtosis (k), entropy and uniformity] were compared between patients with progressive disease (PD) and patients with stable disease (SD), partial or complete response (PR/CR). Receiver operating characteristics including the area under the curve (AUC) and cutoff values including the sensitivity and specificity were calculated.ResultsAccording to RECIST 1.1, 24 patients (64.9%) had PD, 8 SD (21.6%) and 5 PR (13.5%). MRI-based texture analysis showed an earlier differentiation between patients with and without PD when compared with RECIST 1.1. Median k (2.88 vs. 2.35) in arterial phase MRI and median s (0.48 vs. 0.25) and k (2.85 vs. 2.25) in venous phase MRI were significantly different (p < 0.05). The AUC for k derived from arterial phase MRI was 0.73 (cutoff = 2.55, sensitivity = 0.83, specificity = 0.62) (p < 0.05). The AUC for s and k in venous phase MRI was 0.76 (cutoff = 0.35, sensitivity = 0.71, specificity = 0.85) (p > 0.05) and 0.83 (cutoff = 2.50, sensitivity = 0.75, specificity = 0.85) (p < 0.05).ConclusionThis study indicates the potential of MRI-based texture analysis at arterial and venous phase MRI for the early prediction of PD after TARE. Level of Evidence: IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination of the myocardial ischemia.

60 APPLIED LIFE SCIENCES↗

SU-E-T-30: Absorbed Doses Determined by Texture Analysis of Gafchromic EBT3 Films Using Scanning Electron Microscopy: A Feasibility Study

Purpose: The texture analysis method is useful to estimate structural features of images as color, size, and shape. The study aims to determine a dose-response curve by texture analysis of Gafchromic EBT3 film images using scanning electron microscopy (SEM). Methods: The uncoated Gafchromic EBT3 films were prepared to directly scan over the active surface layer of EBT3 film using SEM. The EBT3 films were exposed at a dose range of 0 to 10 Gy using a 6 MV photon beam. The exposed film samples were SEM-scanned at 100X, 1000X, and 3000X magnifications. The four texture features (Homogeneity, Correlation, Contrast, and Energy) were calculated based on the gray level co-occurrence matrix (GLCM) derived from the SEM images at each dose. To validate a correlation between delivered doses and texture features, an R-squared value in linear regression was tested. Results: The results showed that the Correlation index was more suitable as dose indices than the other three texture features due to higher linearity and sensitivity of the dose response curves. Further the Correlation index of 3000X magnified SEM images with 9 pixel offsets had an R-squared value of 0.964. The differences between the delivered doses and the doses measured by this method were 0.9, 1.2, 0.2, and 0.2 Gy at 5, 10, 15, and 20 Gy, respectively. Conclusion: It seems to be feasible to convert micro-scale structural features of {sub χ}t{sub χχχ}he EBT3 films to absorbed doses using the texture analysis method.

60 APPLIED LIFE SCIENCES↗

SU-E-E-16: The Application of Texture Analysis for Differentiation of Central Cancer From Atelectasis

Purpose: Prospectively assess the potential utility of texture analysis for differentiation of central cancer from atelectasis. Methods: 0 consecutive central lung cancer patients who were referred for CT imaging and PET-CT were enrolled. Radiotherapy doctor delineate the tumor and atelectasis according to the fusion imaging based on CT image and PET-CT image. The texture parameters (such as energy, correlation, sum average, difference average, difference entropy), were obtained respectively to quantitatively discriminate tumor and atelectasis based on gray level co-occurrence matrix (GLCM) Results: The texture analysis results showed that the parameters of correlation and sum average had an obviously statistical significance(P<0.05). Conclusion: the results of this study indicate that texture analysis may be useful for the differentiation of central lung cancer and atelectasis.

60 APPLIED LIFE SCIENCES↗

MRI of pancreatic ductal adenocarcinoma: texture analysis of T2-weighted images for predicting long-term outcome

Purpose: To assess the association between T2-weighted imaging (T2WI) texture-analysis parameters and the pathological aggressiveness or long-term outcomes in pancreatic ductal adenocarcinoma (PDAC) patients. Methods: A total of 66 patients (mean age 65.3 ± 9.0 years) who underwent preoperative MRI followed by pancreatectomy for PDAC between 2013 and 2015 were included in this study. A radiologist performed a texture analysis twice on one axial image using commercial software. Differences in the tex parameters, according to pathological factors, were analyzed using a Student’s t test or an ANOVA with Tukey’s test. Univariate and multivariate Cox proportional hazards regression analyses were used to evaluate the association between tex parameters and recurrence-free survival (RFS) or overall survival (OS). Results: The mean follow-up time was 18.5 months, and there were 58 recurrences and 39 deaths. The mean of the positive pixel (MPP)-related factors was significantly lower in poorly differentiated tumors than in well-differentiated tumors as well as in cases with perineural invasion. The univariate Cox proportional hazards analysis showed a significant association between the tex parameters and RFS or OS. However, only tumor size was statistically significant after the multivariate analysis. Only tumor size and entropy with medium texture were significantly associated with OS after the multivariate analysis. Conclusions: Tumor size was a significant predictive factor for RFS and OS in PDAC patients. Although entropy with medium texture analysis was significantly associated with OS, there were also limitations in the texture analysis; thus, further study is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Implementation of a Texture Analysis System

From analysis of the crystalline texture (the distribution of crystalline orientations in a polycrystalline substance) of target samples, some critical material properties of those samples may be deduced. Texture typically results in a specimen from the conditions by which its substance is formed or engineered, and may be used to quantify its qualities. This project aimed to produce a full process for texture analysis of target samples. It was intended that this process be implemented for CCD or imaging plate diffraction data recorded in the Stanford Synchrotron Radiation Lightsource Beamline 11-3. A process was implemented for smoothly analyzing diffraction images and producing full pole figures. The MATLAB package MTEX formed a base for the implementation of this process. This process was applied to diffraction data from a rolled Cu specimen. The resulting raw-interpolated and completed pole figures did not sufficiently match to indicate a correct approximation of the orientation distribution function (ODF) for that specimen. A comparative analysis of MTEX and other pole figure inversion algorithms, as applied to this Cu data, may reveal that another method better approximates the ODF.

43 PARTICLE ACCELERATORS↗

Prediction of liver remnant regeneration after living donor liver transplantation using preoperative CT texture analysis

Purpose: To predict the rate of liver regeneration after living donor liver transplantation (LDLT) using pre-operative computed tomography (CT) texture analysis. Materials and methods: 112 living donors who performed right hepatectomy for LDLT were included retrospectively. We measured the volume of future remnant liver (FLR) on pre-operative CT and the volume of remnant liver (LR) on follow-up CT, taken at a median of 123 days after transplantation. The regeneration index (RI) was calculated using the following equation: [(V{sub LR}−V{sub FLR})/V{sub FLR}] × 100. Computerized texture analysis of the semi-automatically segmented FLR was performed. We used a stepwise, multivariable linear regression to assess associations of clinical features and texture parameters in relation to RI and to make the best-fit predictive model. Results: The mean RI was 110.7 ± 37.8%, highly variable ranging from 22.4% to 247.0%. Among texture parameters, volume of FLR, standard deviation, variance, and gray level co-occurrence matrices (GLCM) contrast were found to have significant correlations between RI. In multivariable analysis, smaller volume of FLR (ß − 0.17, 95% CI − 0.22 to − 0.13) and lower GLCM contrast (ß − 1.87, 95% CI − 3.64 to − 0.10) were associated with higher RI. The regression equation predicting RI was following: RI = 203.82 + 10.42 × pre-operative serum total bilirubin (mg/dL) − 0.17 × V{sub FLR} (cm{sup 3}) − 1.87 × GLCM contrast (× 100). Conclusion: Volume of FLR and GLCM contrast were independent predictors of RI, showing significant negative correlations. Pre-operative CT with texture analysis can be useful for predicting the rate of liver regeneration in living donor of liver transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Texture analysis improves level set segmentation of the anterior abdominal wall

Purpose: The treatment of ventral hernias (VH) has been a challenging problem for medical care. Repair of these hernias is fraught with failure; recurrence rates ranging from 24% to 43% have been reported, even with the use of biocompatible mesh. Currently, computed tomography (CT) is used to guide intervention through expert, but qualitative, clinical judgments, notably, quantitative metrics based on image-processing are not used. The authors propose that image segmentation methods to capture the three-dimensional structure of the abdominal wall and its abnormalities will provide a foundation on which to measure geometric properties of hernias and surrounding tissues and, therefore, to optimize intervention.Methods: In this study with 20 clinically acquired CT scans on postoperative patients, the authors demonstrated a novel approach to geometric classification of the abdominal. The authors’ approach uses a texture analysis based on Gabor filters to extract feature vectors and follows a fuzzy c-means clustering method to estimate voxelwise probability memberships for eight clusters. The memberships estimated from the texture analysis are helpful to identify anatomical structures with inhomogeneous intensities. The membership was used to guide the level set evolution, as well as to derive an initial start close to the abdominal wall.Results: Segmentation results on abdominal walls were both quantitatively and qualitatively validated with surface errors based on manually labeled ground truth. Using texture, mean surface errors for the outer surface of the abdominal wall were less than 2 mm, with 91% of the outer surface less than 5 mm away from the manual tracings; errors were significantly greater (2–5 mm) for methods that did not use the texture.Conclusions: The authors’ approach establishes a baseline for characterizing the abdominal wall for improving VH care. Inherent texture patterns in CT scans are helpful to the tissue classification, and texture analysis can improve the level set segmentation around the abdominal region.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-249: Characterization of Gynecological Tumor Heterogeneity Using Texture Analysis in the Context of An 18F-FDG PET Adaptive Protocol

Purpose: We propose a method to examine gynecological tumor heterogeneity using texture analysis in the context of an adaptive PET protocol in order to establish if texture metrics from baseline PET-CT predict tumor response better than SUV metrics alone as well as determine texture features correlating with tumor response during radiation therapy. Methods: This IRB approved protocol included 29 women with node positive gynecological cancers visible on FDG-PET treated with EBRT to the PET positive nodes. A baseline and intra-treatment PET-CT was obtained. Tumor outcome was determined based on RECIST on posttreatment PET-CT. Primary GTVs were segmented using 40% threshold and a semi-automatic gradient-based contouring tool, PET Edge (MIM Software Inc., Cleveland, OH). SUV histogram features, Metabolic Volume (MV), and Total Lesion Glycolysis (TLG) were calculated. Four 3D texture matrices describing local and regional relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 texture features were calculated. Prognostic power of baseline features derived from gradientbased and threshold GTVs were determined using the Wilcoxon rank-sum test. Receiver Operating Characteristics and logistic regression was performed using JMP (SAS Institute Inc., Cary, NC) to find probabilities of predicting response. Changes in features during treatment were determined using the Wilcoxon signed-rank test. Results: Of the 29 patients, there were 16 complete responders, 7 partial responders, and 6 non-responders. Comparing CR/PR vs. NR for gradient-based GTVs, 7 texture values, TLG, and SUV kurtosis had a p < 0.05. Threshold GTVs yielded 4 texture features and TLG with p < 0.05. From baseline to intra-treatment, 14 texture features, SUVmean, SUVmax, MV, and TLG changed with p < 0.05. Conclusion: Texture analysis of PET imaged gynecological tumors is an effective method for early prognosis and should be used complimentary to SUV metrics, especially when using gradient based segmentation.

60 APPLIED LIFE SCIENCES↗

Latest developments in seismic texture analysis for subsurface structure, facies, and reservoir characterization: A review

In exploration geology and geophysics, seismic texture is still a developing concept that has not been sufficiently known, although quite a number of different algorithms have been published in the literature. This paper provides a review of the seismic texture concepts and methodologies, focusing on latest developments in seismic amplitude texture analysis, with particular reference to the gray level co-occurrence matrix (GLCM) and the texture model regression (TMR) methods. The GLCM method evaluates spatial arrangements of amplitude samples within an analysis window using a matrix (a two-dimensional histogram) of amplitude co-occurrence. The matrix is then transformed into a suite of texture attributes, such as homogeneity, contrast, and randomness, which provide the basis for seismic facies classification. The TMR method uses a texture model as reference to discriminate among seismic features based on a linear, least-squares regression analysis between the model and the data within an analysis window. By implementing customized texture model schemes, the TMR algorithm has the flexibility to characterize subsurface geology for different purposes. A texture model with a constant phase is effective at enhancing the visibility of seismic structural fabrics, a texture model with a variable phase is helpful for visualizing seismic facies, and a texture model with variable amplitude, frequency, and size is instrumental in calibrating seismic to reservoir properties. Preliminary test case studies in the very recent past have indicated that the latest developments in seismic texture analysis have added to the existing amplitude interpretation theories and methodologies. These and future developments in seismic texture theory and methodologies will hopefully lead to a better understanding of the geologic implications of the seismic texture concept and to an improved geologic interpretation of reflection seismic amplitude

58 GEOSCIENCES↗

TU-F-12A-09: GLCM Texture Analysis for Normal-Tissue Toxicity: A Prospective Ultrasound Study of Acute Toxicity in Breast-Cancer Radiotherapy

Purpose: To evaluate the morphologic and structural integrity of the breast glands using sonographic textural analysis, and identify potential early imaging signatures for radiation toxicity following breast-cancer radiotherapy (RT). Methods: Thirty-eight patients receiving breast RT participated in a prospective ultrasound imaging study. Each participant received 3 ultrasound scans: 1 week before RT (baseline), and at 6-week and 3-month follow-ups. Patients were imaged with a 10-MHz ultrasound on the four quadrant of the breast. A second order statistical method of texture analysis, called gray level co-occurrence matrix (GLCM), was employed to assess RT-induced breast-tissue toxicity. The region of interest (ROI) was 28 mm × 10 mm in size at a 10 mm depth under the skin. Twenty GLCM sonographic features, ratios of the irradiated breast and the contralateral breast, were used to quantify breast-tissue toxicity. Clinical assessment of acute toxicity was conducted using the RTOG toxicity scheme. Results: Ninety-seven ultrasound studies (776 images) were analyzed; and 5 out of 20 sonographic features showed significant differences (p < 0.05) among the baseline scans, the acute toxicity grade 1 and 2 groups. These sonographic features quantified the degree of tissue damage through homogeneity, heterogeneity, randomness, and symmetry. Energy ratio value decreased from 108±0.05 (normal) to 0.99±0.05 (Grade 1) and 0.84±0.04 (Grade 2); Entropy ratio value increased from 1.01±0.01 to 1.02±0.01 and 1.04±0.01; Contrast ratio value increased from 1.03±0.03 to 1.07±0.06 and 1.21±0.09; Variance ratio value increased from 1.06±0.03 to 1.20±0.04 and 1.42±0.10; Cluster Prominence ratio value increased from 0.98±0.02 to 1.01±0.04 and 1.25±0.07. Conclusion: This work has demonstrated that the sonographic features may serve as imaging signatures to assess radiation-induced normal tissue damage. While these findings need to be validated in a larger cohort, they suggest that ultrasound imaging may be used to improve early detection of normal-tissue toxicity in breast-cancer RT.

60 APPLIED LIFE SCIENCES↗

SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity differences between primary and lymphoma tumor by multi-scale image texture analysis. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

5-Fluorouracil induced liver toxicity in patients with colorectal cancer: role of computed tomography texture analysis as a potential biomarker

Purpose: To assess if CT texture analysis (TA) can serve as a biomarker of liver toxicity in patients with colorectal cancer treated with 5-fluorouracil (5-FU)-based chemotherapy. Methods: In this IRB-approved, HIPAA-compliant retrospective study, patients with colorectal cancer treated with 5-FU-based regimens during 2008–2010 were identified from institutional electronic database. Total 43 patients (23 women; mean age 56 years) with normal baseline liver function tests (LFTs), availability of baseline (pre-chemotherapy) and first follow-up CT (median 1.7 months, interquartile range (IQR) 1.5–2.5) performed during chemotherapy were included. Two single-slice ROI of right and left liver lobe were obtained on baseline and first follow-up CT for TA. Texture features [mean, entropy, kurtosis, skewness, mean of positive pixel, standard deviation (SD)] were extracted using a commercially available software (TexRAD; Feedback Medical Ltd, Cambridge, UK). Changes in texture parameters between baseline and follow-up CT were evaluated with Wilcoxon signed-rank test for patients with and without LFT elevation during chemotherapy. Results: Patients with LFT elevation (n = 34; 79%) showed significantly different mean, entropy, skewness, and SD (p values range 0.007–0.047) between baseline and first follow-up CT. No significant changes in features were observed in patients without LFT elevation (n = 9; 21%). In 19 patients (56%), first follow-up CT was performed before elevation of LFTs was observed. Conclusions: This proof-of-concept study shows that there are early changes in liver texture on first follow-up CT in patients with LFT elevation during 5-FU-based chemotherapy for colorectal cancer. In more than 50% of cases, these changes occur before LFT elevation becomes evident on blood tests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗