Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A test matrix sequencer for research test facility automation

The hardware and software configuration of a Test Matrix Sequencer, a general purpose test matrix profiler that was developed for research test facility automation at the NASA Lewis Research Center, is described. The system provides set points to controllers and contact closures to data systems during the course of a test. The Test Matrix Sequencer consists of a microprocessor controlled system which is operated from a personal computer. The software program, which is the main element of the overall system is interactive and menu driven with pop-up windows and help screens. Analog and digital input/output channels can be controlled from a personal computer using the software program. The Test Matrix Sequencer provides more efficient use of aeronautics test facilities by automating repetitive tasks that were once done manually.

Mccartney, Timothy P.↗

A test matrix sequencer for research test facility automation

The hardware and software configuration of a Test Matrix Sequencer, a general purpose test matrix profiler that was developed for research test facility automation at the NASA Lewis Research Center, is described. The system provides set points to controllers and contact closures to data systems during the course of a test. The Test Matrix Sequencer consists of a microprocessor controlled system which is operated from a personal computer. The software program, which is the main element of the overall system is interactive and menu driven with pop-up windows and help screens. Analog and digital input/output channels can be controlled from a personal computer using the software program. The Test Matrix Sequencer provides more efficient use of aeronautics test facilities by automating repetitive tasks that were once done manually.

Mccartney, Timothy P.↗

Turbine Air-Flow Test Rig CFD Results for Test Matrix

This paper presents the Turbine Air-Flow Test (TAFT) rig computational fluid dynamics (CFD) results for test matrix. The topics include: 1) TAFT Background; 2) Design Point CFD; 3) TAFT Test Plan and Test Matrix; and 4) CFD of Test Points. This paper is in viewgraph form.

Wilson, Josh↗

Addressable test matrix for measuring analog transfer characteristics of test elements used for integrated process control and device evaluation

A set of addressable test structures, each of which uses addressing schemes to access individual elements of the structure in a matrix, is used to test the quality of a wafer before integrated circuits produced thereon are diced, packaged and subjected to final testing. The electrical characteristic of each element is checked and compared to the electrical characteristic of all other like elements in the matrix. The effectiveness of the addressable test matrix is in readily analyzing the electrical characteristics of the test elements and in providing diagnostic information.

Buehler, Martin G.↗

Test-Matrix Sequencer

Repetitive tasks in laboratory tests automated to increase productivity. Test-matrix sequencer is digital/analog electronic system providing for automatic implementation of multiple interrelated sequences of test conditions in laboratory experiment. Designed for use in testing aeronautical propulsion systems in wind tunnels, has potential for use in automated testing laboratories in general, sequencing of servo-controlled actuators, and programming of robotic manipulators.

Mccartney, Timothy P.↗

Halogenation of used aluminum matrix test reactor fuel – a bench-scale demonstration with surrogate materials

In this work, experiments with surrogate materials were performed at bench scale to demonstrate a halogenation technique applicable to treatment of used aluminum matrix test reactor fuel. The technique involves dissolution and separation of aluminum from used aluminum matrix test reactor fuel in molten-halide salt systems prior to treatment and disposition of the fuel’s uranium and fission products. Demonstration of the halogenation technique was performed with neodymium metal as a non-radiological surrogate for uranium metal. Experiments involved blending forms of aluminum and neodymium metal with ammonium and lithium chloride or ammonium and lithium bromide, which upon heating decomposed into ammonia gas and the respective hydrogen chloride or bromide gas. The latter reacted with the metals to form the respective aluminum and neodymium halides. At elevated temperatures, aluminum halides gasified away from the respective neodymium halides, which fused with their respective lithium halides. Samples of fused and distillate salts were collected and analyzed, yielding extents of aluminum removal that ranged from 94.5–98.2% for chlorination runs and 91.4–97.8% for bromination runs. No neodymium was detected in the distillate fractions. Some experiments were repeated with excess reactants, and a portion of aluminum chloride distillate was processed into a consolidated waste form.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design verification test matrix development for the STME thrust chamber assembly

This report presents the results of the test matrix development for design verification at the component level for the National Launch System (NLS) space transportation main engine (STME) thrust chamber assembly (TCA) components including the following: injector, combustion chamber, and nozzle. A systematic approach was used in the development of the minimum recommended TCA matrix resulting in a minimum number of hardware units and a minimum number of hot fire tests.

Dexter, Carol E.↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AFC FY 2023 HFIR Irradiation Test Matrix – Supported by the Design of a Ring Specimen Irradiation Vehicle

The development and deployment of accident-tolerant cladding materials in light water nuclear reactors requires the collection of neutron-irradiated properties of these materials with specific consideration to the material properties orientation (i.e., tube geometry). To that end, a test plan to irradiate several cladding tube and ring specimens in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) was proposed, along with the development of a new capsule design that features ring specimens with a preexisting gauge section. This ring specimen geometry removes the need to machine a gauge section on the irradiated specimen and thus allows for direct application of a ring-pull test post-irradiation. The test matrix includes uncoated and chromium-coated Zircaloy-4 and advanced zirconium alloy cladding specimens, pre-characterized at ORNL. Plans are to irradiate the specimens at about 4 and 10 dpa—corresponding to two and five cycles at the HFIR centerline—with a target specimen gauge section temperature of 330°C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Addressable Inverter Matrix Tests Integrated-Circuit Wafer

Addressing elements indirectly through shift register reduces number of test probes. With aid of new technique, complex test structure on silicon wafer tested with relatively small number of test probes. Conserves silicon area by reduction of area devoted to pads. Allows thorough evaluation of test structure characteristics and of manufacturing process parameters. Test structure consists of shift register and matrix of inverter/transmission-gate cells connected to two-by-ten array of probe pads. Entire pattern contained in square area having only 1.6-millimeter sides. Shift register is conventional static CMOS device using inverters and transmission gates in master/slave D flip-flop configuration.

Buehler, Martin G.↗

A creep model for metallic composites based on matrix testing: Application to Kanthal composites

An anisotropic creep model is formulated for metallic composites with strong fibers and low to moderate fiber volume percent (less than 40 percent). The idealization admits no creep in the local fiber direction and assumes equal creep strength in longitudinal and transverse shear. Identification of the matrix behavior with that of the isotropic limit of the theory permits characterization of the composite through uniaxial creep tests on the matrix material. Constant and step-wise creep tests are required as a data base. The model provides an upper bound on the transverse creep strength of a composite having strong fibers embedded in a particular matrix material. Comparison of the measured transverse strength with the upper bound gives an assessment of the integrity of the composite. Application is made to a Kanthal composite, a model high-temperature composite system. Predictions are made of the creep response of fiber reinforced Kanthal tubes under interior pressure.

Binienda, W. K.↗

Irradiation of Advanced Cladding Specimens in the High Flux Isotope Reactor: Capsule Designs and Test Matrix

The Advanced Fuels Campaign (AFC) has initiated the Advanced Reactor Cladding (ARC) irradiation campaign to generate irradiation performance data for candidate fuel cladding concepts. The campaign includes a diverse set of ferritic/martensitic steels, oxide dispersion strengthened (ODS) alloys, FeCrAlbased alloys, coated materials, and welded cladding specimens produced through multiple US Department of Energy (DOE) programs and international collaborations. Three complementary experimental thrusts comprise the campaign: tensile testing (ARC Tensile) to rapidly screen candidate alloys, fracture toughness testing (ARC Fracture) to evaluate irradiation effects on crack resistance, and tubular weld testing (ARC Weld) to quantify irradiation-induced changes in the mechanical performance of end cap welds. This report documents the irradiation campaign design, including the selected materials, specimen types, irradiation matrix, and capsule designs for irradiation within the High Flux Isotope Reactor (HFIR). A total of 14 irradiation capsules were developed to achieve target irradiation temperatures between 300°C and 600°C and doses up to 30 dpa. Thermal analyses were performed using finite element methods to establish capsule geometries capable of achieving the desired specimen temperatures while accommodating differences in specimen geometry and material properties. The resulting capsule designs provide the basis for irradiation of the AFC-ARC experimental matrix and subsequent post-irradiation examination to assess the effects of neutron irradiation on advanced cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AMMT FY23 HFIR Irradiation Test Matrix – Supported by the Design of a Miniature Bend Bar Irradiation Vehicle

With the continued advancement of additive manufacturing (AM) techniques, interest has grown in the development and qualification of steels produced via these methods for use in the structural components of advanced nuclear reactors. Therefore, it is crucial that the properties of these materials such as the tensile strength and fracture toughness be investigated following neutron irradiation to support their use in industry. To that end, a test plan to irradiate several tensile and bend bar specimens in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory was proposed, along with the development of a new “MINBEN” capsule design that features MBS-1 bend bar specimens that have a larger cross-sectional area than those of previous designs, which allows for higher temperature out-of-pile testing. The specimens include AM 316H stainless steel with wrought 316H and A709 stainless steels for reference, and they will be irradiated at 2 dpa and 10 dpa—corresponding to roughly 1 and 5 cycles at the HFIR midplane—at temperatures of 400°C and 600°C. The MINBEN design was found to be capable of providing specimen test plane average temperatures in the range of 220–660°C for six specimens, with a min-max spread in this temperature of ~40°C and a 95% confidence interval of ~24°C. This analysis shows that the capsule provides an effective vehicle for gathering needed high-temperature fracture toughness data.

36 MATERIALS SCIENCE↗

AMMT Round Robin 316H HFIR Irradiation Test Matrix and Readiness for Insertion

The Round Robin 316H HFIR-2 irradiation campaign, conducted under the Advanced Materials and Manufacturing Technologies (AMMT) Program, is designed to evaluate the variability in irradiation response of laser powder bed fusion (LPBF) stainless steel (SS)-316H across multiple national laboratories, powder heats, and processing conditions, with comparison to wrought counterparts. A total of 11 materials are intended for irradiation in the High Flux Isotope Reactor (HFIR), targeting two irradiation temperatures (400°C and 600°C) and one level of irradiation damage (2 dpa). This irradiation campaign utilizes the standardized general tensile (GENTEN) capsule design to accommodate subsized tensile specimens of these materials. Thermal analyses were performed to ensure appropriate temperature control by design and uniformity within the capsules. All the capsules for this irradiation except one have been successfully assembled, welded, and tested and are ready for HFIR insertion. The last capsule requires re-build following a failed weld. All eight capsules are intended to be inserted in HFIR cycle 517, which is scheduled to start September 8, 2026. This report summarizes the design, material selection, and readiness for insertion of the capsules.

36 MATERIALS SCIENCE↗

Report on Year-3 of Water NSTF Matrix Testing: Two-Phase Parametric Test Series

The Natural convection Shutdown heat removal Test Facility (NSTF) is large scale test facility constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactor concepts. With support from the Department of Energy (DOE) offices of Advanced Reactor Technologies (ART) and Advanced Reactors Regulatory Development (RD), this facility reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nickel hydrogen battery cell storage matrix test

Test were conducted to evaluate post storage performance of nickel hydrogen cells with various design variables, the most significant being nickel precharge versus hydrogen precharge. Test procedures and results are presented in outline and graphic form.

Wheeler, James R.↗

Small Scale Melter Testing of HLW Algorithm Glasses: Matrix 1 Tests

The principal objectives of the DM100 tests were to determine the effects of glass property extremes (glass viscosity, electrical conductivity, and T1%), minimum and maximum concentrations of several major and minor glass components, +/-15% batching errors in the addition of Glass Forming Chemicals (GFCs) to the feed, and variation in the sources of boron and sodium used in the GFCs on processing rates and melter conditions (off-gas characteristics, glass processing, foaming, cold cap, etc.) at constant bubbling rate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗