Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temporal laser pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Temporal laser pulse manipulation using multiple optical ring-cavities

An optical pulse stretcher and a mathematical algorithm for the detailed calculation of its design and performance is disclosed. The optical pulse stretcher has a plurality of optical cavities, having multiple optical reflectors such that an optical path length in each of the optical cavities is different. The optical pulse stretcher also has a plurality of beam splitters, each of which intercepts a portion of an input optical beam and diverts the portion into one of the plurality of optical cavities. The input optical beam is stretched and a power of an output beam is reduced after passing through the optical pulse stretcher and the placement of the plurality of optical cavities and beam splitters is optimized through a model that takes into account optical beam divergence and alignment in the pluralities of the optical cavities. The optical pulse stretcher system can also function as a high-repetition-rate (MHz) laser pulse generator, making it suitable for use as a stroboscopic light source for high speed ballistic projectile imaging studies, or it can be used for high speed flow diagnostics using a laser light sheet with digital particle imaging velocimetry. The optical pulse stretcher system can also be implemented using fiber optic components to realize a rugged and compact optical system that is alignment free and easy to use.

Nguyen, Quang-Viet↗

Planar Laser Imaging of Sprays for Liquid Rocket Studies

A planar laser imaging technique which incorporates an optical polarization ratio technique for droplet size measurement was studied. A series of pressure atomized water sprays were studied with this technique and compared with measurements obtained using a Phase Doppler Particle Analyzer. In particular, the effects of assuming a logarithmic normal distribution function for the droplet size distribution within a spray was evaluated. Reasonable agreement between the instrument was obtained for the geometric mean diameter of the droplet distribution. However, comparisons based on the Sauter mean diameter show larger discrepancies, essentially because of uncertainties in the appropriate standard deviation to be applied for the polarization ratio technique. Comparisons were also made between single laser pulse (temporally resolved) measurements with multiple laser pulse visualizations of the spray.

Lee, W.↗

High-Fidelity Flash Lidar Model Development

NASA's Autonomous Landing and Hazard Avoidance Technologies (ALHAT) project is currently developing the critical technologies to safely and precisely navigate and land crew, cargo and robotic spacecraft vehicles on and around planetary bodies. One key element of this project is a high-fidelity Flash Lidar sensor that can generate three-dimensional (3-D) images of the planetary surface. These images are processed with hazard detection and avoidance and hazard relative navigation algorithms, and then are subsequently used by the Guidance, Navigation and Control subsystem to generate an optimal navigation solution. A complex, high-fidelity model of the Flash Lidar was developed in order to evaluate the performance of the sensor and its interaction with the interfacing ALHAT components on vehicles with different configurations and under different flight trajectories. The model contains a parameterized, general approach to Flash Lidar detection and reflects physical attributes such as range and electronic noise sources, and laser pulse temporal and spatial profiles. It also provides the realistic interaction of the laser pulse with terrain features that include varying albedo, boulders, craters slopes and shadows. This paper gives a description of the Flash Lidar model and presents results from the Lidar operating under different scenarios.

Hines, Glenn D.↗

The Laser Atmospheric Wind Sounder (LAWS) Phase 2 Preliminary Laser Design

The requirements for the Laser Atmospheric Wind Sounder (LAWS) were determined from system considerations and are summarized in tabular form. The laser subsystem provides for the generation and frequency control of two beams, the transmit high power and local oscillator beams, which are delivered to the optical and receiver subsystems, respectively. In our baseline approach, the excitation of the gain section is achieved by a self-sustaining uv-(corona) preionized discharge. Gas is recirculated within the laser loop using a transverse flow fan. An intra-flow-loop heat exchanger, catalyst monolith, and acoustic attenuators condition the gas to ensure uniform energy output and high beam quality during high pulse repetition rate operation. The baseline LAWS laser pulse temporal profile as calculated by in-house laser codes is given in graphical form.

Lawrence, T. Rhidian↗

Analysis of the interaction of a laser pulse with a silicon wafer - Determination of bulk lifetime and surface recombination velocity

The decay of excess minority carriers produced in a silicon wafer of thickness d by a laser pulse is analyzed. A comprehensive theory based on this analysis is presented for the determination of bulk lifetime Tau(b) and surface recombination velocity S. It is shown that, starting with an exponential spatial profile, the carrier profile assumes a spatially symmetrical form after approximately one time constant of the fundamental mode of decay. Expressions for the spatial average of the carrier density as a function of time are derived for three temporal laser pulse shapes: impulse, square, and Gaussian. Particular attention is paid to the time constants of the fundamental and higher modes of decay. The ratios of the time constants of the higher modes to the fundamental mode, as well as the time constant of the fundamental mode, are presented over wide ranges of values of S and d. For Sd less than about 40 sq cm/s, a two-wafer method is developed to determine Tau(b) and S; it is also shown that the requirement of d/Tau(b) greater than about 20S is sufficient to adequately guarantee that the asymptotic value of the instantaneous observed lifetime differs from the bulk lifetime by no more than 10 percent.

Luke, Keung L.↗

Experimental Results for Temporally Overlapping Pulses from Quantel EverGreen 200 Laser

This report will detail the experimental results and observations obtained while investigating the feasibility of temporally overlapping the two laser pulses from a Quantel EverGreen 200 Laser. This laser was specifically designed for Particle Imaging Velocimetry (PIV) applications and operate by emitting two 532 nm laser pulses that are seperated by an adjustable finite time (typically on the order of ten to hundreds of microseconds). However, the use of this model laser has found recent application for Pressure Sensitive Paint (PSP) testing, especially for rotorcraft research. For this testing, it is desired to only use one laser pulse. While this is easily done by only firing one of the laser heads, more excitation energy could conceivably be had if both laser heads are fired with zero pulse separation. In addition, recently large field-of-view PIV measurements have become possible and need ever increasing laser power to illuminate the larger areas. For this work, two different methods of timing the laser are investigated using both a traditional power meter to monitor laser power as well as a fast photodiode to determine pulse separation. The results are presented here as well as some simple implications for PIV experiments using these methods.

Watkins, A. Neal↗

Heating of solid targets with laser pulses

Analytical and numerical solutions to the heat-conduction equation are obtained for the heating of absorbing media with pulsed lasers. The spatial and temporal form of the temperature is determined using several different models of the laser irradiance. Both surface and volume generation of heat are discussed. It is found that if the depth of thermal diffusion for the laser-pulse duration is large compared to the optical-attenuation depth, the surface- and volume-generation models give nearly identical results. However, if the thermal-diffusion depth for the laser-pulse duration is comparable to or less than the optical-attenuation depth, the surface-generation model can give significantly different results compared to the volume-generation model. Specific numerical results are given for a tungsten target irradiated by pulses of different temporal durations and the implications of the results are discussed with respect to the heating of metals by picosecond laser pulses.

Bechtel, J. H.↗

Computer modeling of pulsed CO2 lasers for lidar applications

The object of this effort is to develop code to enable the accurate prediction of the performance of pulsed transversely excited (TE) CO2 lasers prior to their construction. This is of particular benefit to the NASA Laser Atmospheric Wind Sounder (LAWS) project. A benefit of the completed code is that although developed specifically for the pulsed CO2 laser much of the code can be modified to model other laser systems of interest to the lidar community. A Boltzmann equation solver has been developed which enables the electron excitation rates for the vibrational levels of CO2 and N2, together with the electron ionization and attachment coefficients to be determined for any CO2 laser gas mixture consisting of a combination of CO2, N2, CO, He and CO. The validity of the model has been verified by comparison with published material. The results from the Boltzmann equation solver have been used as input to the laser kinetics code which is currently under development. A numerical code to model the laser induced medium perturbation (LIMP) arising from the relaxation of the lower laser level has been developed and used to determine the effect of LIMP on the frequency spectrum of the LAWS laser output pulse. The enclosed figures show representative results for a laser operating at 0.5 atm. with a discharge cross-section of 4.5 cm to produce a 20 J pulse with aFWHM of 3.1 microns. The first four plots show the temporal evolution of the laser pulse power, energy evolution, LIMP frequency chirp and electric field magnitude. The electric field magnitude is taken by beating the calculated complex electric field and beating it with a local oscillator signal. The remaining two figures show the power spectrum and energy distribution in the pulse as a function of the varying pulse frequency. The LIMP theory has been compared with experimental data from the NOAA Windvan Lidar and has been found to be in good agreement.

Spiers, Gary D.↗

Effects of laser source parameters on the generation of narrow band and directed laser ultrasound

Predictive and prescriptive modeling of laser arrays is performed to demonstrate the effects of the extension of array elements on laser array performance. For a repetitively pulsed laser source (the temporal laser array), efficient frequency compression is best achieved by detecting longitudinal waves off-epicenter in plates where the source size and shape directly influence the longitudinal wave shape and duration; the longitudinal array may be tailored for a given repetition frequency to yield efficient overtone energy compression into the fundamental frequency band. For phased arrays, apparent array directivity is heavily influenced by array element size.

Spicer, James B.↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

Spectrally Tailored Pulsed Thulium Fiber Laser System for Broadband Lidar CO2 Sensing

Thulium doped pulsed fiber lasers are capable of meeting the spectral, temporal, efficiency, size and weight demands of defense and civil applications for pulsed lasers in the eye-safe spectral regime due to inherent mechanical stability, compact "all-fiber" master oscillator power amplifier (MOPA) architectures, high beam quality and efficiency. Thulium fiber's longer operating wavelength allows use of larger fiber cores without compromising beam quality, increasing potential single aperture pulse energies. Applications of these lasers include eye-safe laser ranging, frequency conversion to longer or shorter wavelengths for IR countermeasures and sensing applications with otherwise tough to achieve wavelengths and detection of atmospheric species including CO2 and water vapor. Performance of a portable thulium fiber laser system developed for CO2 sensing via a broadband lidar technique with an etalon based sensor will be discussed. The fielded laser operates with approximately 280 J pulse energy in 90-150ns pulses over a tunable 110nm spectral range and has a uniquely tailored broadband spectral output allowing the sensing of multiple CO2 lines simultaneously, simplifying future potentially space based CO2 sensing instruments by reducing the number and complexity of lasers required to carry out high precision sensing missions. Power scaling and future "all fiber" system configurations for a number of ranging, sensing, countermeasures and other yet to be defined applications by use of flexible spectral and temporal performance master oscillators will be discussed. The compact, low mass, robust, efficient and readily power scalable nature of "all-fiber" thulium lasers makes them ideal candidates for use in future space based sensing applications.

Heaps, William S.↗

Saturation Phenomena in LIF Measurements, Appendix B

Optical saturation is the phenomenon in which the laser-induced rates of absorption and spontaneous emission between two levels, induced by a laser, become comparable to or greater than the spontaneous emission and collision rates connecting these levels. This results in the excited state population N(u) acquiring a value of similar magnitude to that of the ground state, N(e). Under these conditions the observed fluorescence signal, which is proportional to N(u), is no longer linearly dependent on laser intensity I, but increases at a slower rate, and in principle ultimately becomes independent of I. A conceptual picture of optical saturation using a two-level picture is described. This is, however, inadequate for the description of a real experiment involving a molecule, such as OH, for several reasons, which will be explained briefly; these are the multi-level nature of the electronic states and energy transfer among them and effects due to spatial, spectral, and temporal fluctuations in the laser pulse.

Source record↗

Redistribution of radiation in the absence of collisions

Redistribution and depolarization of near-resonant radiation is studied for the He 2(1P)-3(1D) line (668 nm) and some data for H-alpha (656 nm) are also presented. A Nd:YAG pumped dye laser, with a bandwidth of 0.1/cm and a power density of 100 kW/sq cm, is used in the experiment. The transitions have lower levels with natural line widths that are large compared with their upper-level natural widths, and, under experimental conditions, their collisional widths are also small. The ratio of fluorescence to Rayleigh intensity is measured and the results indicate that while the Rayleigh emission has the same temporal development as the laser pulse (5 ns FWHM), the fluorescent intensity has a decay time determined by the radiative decay lifetime and by collisional quenching. The prediction that redistribution of radiation occurs in the absence of collisions for transitions having significant lower-level radiative widths is confirmed. Depolarization rates by collisions with helium are also inferred from the measurements.

Lombardi, G. G.↗

Laser-fluorescence measurements of nitric oxide in low-pressure H2/O2/NO flames

The concentration profiles of NO in low-pressure (76 Torr) H2/O2/Ar flames to which nitric oxide is added are measured by pulsed laser-induced fluorescence. Temporally resolved fluorescence measurements are used to determine the collisional deexcitation rates needed to convert time-integrated fluorescence signal into oxide concentration. Five flames are studied with H2/O2 equivalence ratios of 0.88, 0.98, 1.22, 1.37, and 1.50. In these flames the collisional deexcitation rate decreases rapidly above the burner surface as the density decreases with increasing temperature. A 20 percent decrease is observed for the lean flames, and a 30 percent decrease for the rich flames. Within the precision of the measurement technique (+ or - 10 percent), no significant removal of nitric oxide is observed in these flames.

Cattolica, R. J.↗

Time and wavelength domain algorithms for chemical analysis by laser radar

Laser-induced fluorescence (LIF) is a promising technique for laser radar applications. Laser radar using LIF has already been applied to algae blooms and oil slicks. Laser radar using LIF has great potential for remote chemical analysis because LIF spectra are extremely sensitive to chemical composition. However, most samples in the real world contain mixtures of fluorescing components, not merely individual components. Multicomponent analysis of laser radar returns from mixtures is often difficult because LIF spectra from solids and liquids are very broad and devoid of line structure. Therefore, algorithms for interpreting LIF spectra from laser radar returns must be able to analyze spectra that overlap in multicomponent systems. This paper analyzes the possibility of using factor analysis-rank annihilation (FARA) to analyze emission-time matrices (ETM) from laser radar returns instead of excitation-emission matrices (EEM). The authors here define ETM as matrices where the rows (or columns) are emission spectra at fixed times and the columns (or rows) are temporal profiles for fixed emission wavelengths. Laser radar usually uses pulsed lasers for ranging purposes, which are suitable for measuring temporal profiles. Laser radar targets are hard instead of diffuse; that is, a definite surface emits the fluorescence instead of an extended volume. A hard target would not broaden the temporal profiles as would a diffuse target. Both fluorescence lifetimes and emission spectra are sensitive to chemical composition. Therefore, temporal profiles can be used instead of excitation spectra in FARA analysis of laser radar returns. The resulting laser radar returns would be ETM instead of EEM.

Rosen, David L.↗

Collisional Removal of OH (X (sup 2)Pi, nu=7) by O2, N2, CO2, and N2O

Collisional removal rate constants for the OH (X 2PI, nu = 7) radical are measured for the colliders O2, CO2, and N2O, and an upper limit is established for N2. OH(nu = 4) molecules, generated in a microwave discharge flow cell by the reaction of hydrogen atoms with ozone, are excited to v = 7 by the output of a pulsed infrared laser via direct vibrational overtone excitation. The temporal evolution of the P = 7 population is probed as a function of the collider gas partial pressure by a time-delayed pulsed ultraviolet laser. Fluorescence from the B 21 + state is detected in the visible spectral region.

Knutsen, Karen↗

Temporal correlation measurements of pulsed dual CO2 lidar returns

A pulsed dual-laser direct-detection differential-absorption lidar DIAL system, operating near 10.6 microns, is used to measure the temporal correlation and statistical properties of backscattered returns from specular and diffuse topographic targets. Results show that atmospheric-turbulence fluctuations can effectively be frozen for pulse separation times on the order of 1-3 msec or less. The diffuse target returns, however, yielded a much lower correlation than that obtained with the specular targets; this being due to uncorrelated system noise effects and different statistics for the two types of target returns.

Menyuk, N.↗

Laser-Induced Incandescence in Microgravity

Knowledge of soot concentration is important due to its presence and impact upon a wide range of combustion processes ranging from diffusion to premixed flames, laminar to turbulent processes and homogeneous to heterogeneous combustion. Measurement of soot volume fraction (f(sub v)) is essential to discerning its formation and growth. The presence of soot also affects other physical and chemical properties of combustion thereby affecting studies not directly concerned with either its formation or growth, such as radiative heat transfer, CO oxidation and fuel vaporization or pyrolysis rates. Microgravity offers unique opportunities for studying both soot growth and the effect of soot radiation upon flame structure and spread. Spatial scales and residence time scales are greatly extended in 0-g facilitating soot growth studies. With the varied geometries, short duration microgravity test times and time-varying processes there is a demand for measurement of f(sub v) with high spatial and temporal resolution. Laser-induced incandescence (LII) has advanced f(sub v) measurements in many 1-g combustion processes. To create laser-induced incandescence, a pulsed high intensity laser heats soot to incandescence temperatures. Using appropriate spectral and temporal detection conditions, the resulting incandescence can be selectively detected apart from the non-laser-heated soot and flame gases. Theoretical modelling and experiments have shown that the resulting incandescence is representative of f(sub v). Using an intensified array camera and a laser sheet for excitation, one- and two-dimensionally resolved LII images of f(sub v) have been obtained in 1-g. LII has been characterized and developed at NASA-Lewis for soot volume fraction determination in a wide range of 1-g combustion applications. Broadly grouped, the characterization work has included studies of excitation intensity, excitation wavelength and the optimum temporal and spectral detection conditions to enable an accurate representation of soot volume fraction by LII. Tests for special requirements imposed by different combustion processes have been performed in laminar and turbulent diffusion flames, rich sooting premixed flames, single droplet combustion, and other heterogeneous combustion. These studies demonstrated LII's high sensitivity, temporal and spatial capabilities and its geometric versatility. In contrast to the advantages offered to combustion studies by a microgravity environment, advanced diagnostics, specifically those requiring pulsed laser diagnostics have been limited due to the size, weight and power limitations in a low-gravity environment. Reported here are the first demonstrations of LII performed in a microgravity environment. Examples are shown for laminar and turbulent gas-jet diffusion flames in 0-g.

VanderWal, Randy L.↗