Shallow (2-meter) Temperature Surveys in Colorado

Shallow temperature surveys are useful in early-stage geothermal exploration to delineate surface outflow zones, with the intent to identify the source of upwelling, usually a fault. Detailed descriptions of the 2-meter survey method and equipment design can be found in Coolbaugh et al. (2007) and Sladek et al. (2007), and are summarized here. The survey method was devised to measure temperature as far below the zone of solar influence as possible, have minimal equilibration time, and yet be portable enough to fit on the back of an all-terrain vehicle (ATV); Figure 2). This method utilizes a direct push technology (DPT) technique where 2.3 m long, 0.54" outer diameter hollow steel rods are pounded into the ground using a demolition hammer. Resistance temperature devices (RTD) are then inserted into the rods at 2-meter depths, and allowed to equilibrate for one hour. The temperatures are then measured and recorded, the rods pulled out of the ground, and re-used at future sites. Usually multiple rods are planted over the course of an hour, and then the sampler returns back to the first station, measures the temperatures, pulls the rods, and so on, to eliminate waiting time. At Wagon Wheel Gap, 32 rods were planted around the hot springs between June 20 and July 1, 2012. The purpose was to determine the direction of a possible upflow fault or other structure. Temperatures at 1.5m and 2m depths were measured and recorded in the attribute table of this point shapefile. Several anomalous temperatures suggest that outflow is coming from a ~N60W striking fault or shear zone that contains the quartz-fluorite-barite veins of the adjacent patented mining claims. It should be noted that temperatures at 2m depth vary according to the amount of solar heating from above, as well as possible geothermal heating from below.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Deep Wells Temperature Surveys as of September 2022

This Excel spreadsheet contains temperature survey results for Utah FORGE wells 58-32, 78-32, 56-32, 16A(78)-32 and 78B-32. It also contains charts and comparisons, along with a "Data Summary" which provides links to previous GDR submissions with temperature data for each well.

15 GEOTHERMAL ENERGY↗

McGee Mountain Shallow (2m) Temperature Survey, Humboldt County, Nevada 2009

This shapefile contains location and attribute data for a shallow (2 meter) temperature survey conducted by Geothermal Technical Partners, Inc. during late 2008 and early 2009. Temperatures at 2m depth were measured at 192 separate points as outlined by Coolbaugh et al., 2007. The purpose of the survey was to try and detect a shallow thermal anomaly associated with the McGee Mountain geothermal area as discovered by Phillips Petroleum and Earth Power Resources in the late 1970’s. Drilling identified ~120oC temperatures at ~100m depth. This 2-meter survey delineated what was interpreted as a steam-heated fault zone centered along a range front fault in the vicinity of the drilled holes and fumaroles. Coolbaugh, M.F., Sladek, C., Faulds, J.E., Zehner, R.E., and Oppliger, G.L., 2007, Use of rapid temperature measurements at a 2-meter depth to augment deeper temperature gradient drilling: Proceedings, 32nd Workshop on Geothermal Reservoir Engineering, Stanford University, Stanford, CA, Jan. 22-24, 2007, p. 109-116. Zehner, R., Tullar, K., and Rutledge, E., 2012, Effectiveness of 2-Meter and geoprobe shallow temperature surveys in early stage geothermal exploration: Geothermal Resources Council Transactions, v. 36, in press.

15 GEOTHERMAL ENERGY↗

Exhaust-Gas Pressure and Temperature Survey of F404-GE-400 Turbofan Engine

An exhaust-gas pressure and temperature survey of the General Electric F404-GE-400 turbofan engine was conducted in the altitude test facility of the NASA Lewis Propulsion System Laboratory. Traversals by a survey rake were made across the exhaust-nozzle exit to measure the pitot pressure and total temperature. Tests were performed at Mach 0.87 and a 24,000-ft altitude and at Mach 0.30 and a 30,000-ft altitude with various power settings from intermediate to maximum afterburning. Data yielded smooth pressure and temperature profiles with maximum jet temperatures approximately 1.4 in. inside the nozzle edge and maximum jet temperatures from 1 to 3 in. inside the edge. A low-pressure region located exactly at engine center was noted. The maximum temperature encountered was 3800 R.

Walton, James T.↗

Granite Springs Valley, Nevada Play Fairway Analysis - Well data and Temperature Survey

This data is associated with the Nevada Play Fairway project and includes excel files containing raw 2-meter temperature data and corrections. GIS shapefiles and layer files contain ing location and attribute information for the data are included. Well data includes both deep and shallow TG holes, GIS shapefiles and layer files.

15 GEOTHERMAL ENERGY↗

Inflight fuel tank temperature survey data

Statistical summaries of the fuel and air temperature data for twelve different routes and for different aircraft models (B747, B707, DC-10 and DC-8), are given. The minimum fuel, total air and static air temperature expected for a 0.3% probability were summarized in table form. Minimum fuel temperature extremes agreed with calculated predictions and the minimum fuel temperature did not necessarily equal the minimum total air temperature even for extreme weather, long range flights.

Pasion, A. J.↗

Line Focus Receiver Infrared Temperature Survey System

For ongoing maintenance and performance purposes, solar parabolic trough field operators desire to know that the Heat Collection Elements (HCEs) are performing properly. Measuring their temperature is one way of doing this One 30MW field can contain approximately 10,000 HCE's. This software interfaces with a GPS receiver and an infrared camera. It takes global positioning data from the GPS and uses this information to automate the infrared image capture and temperature analysis of individual solar parabolic HCEs in a solar parabolic trough field With this software system an entire 30MW field can be surveyed in 2-3 days.

Wendelin, Tim↗

Hawthorne Nevada Deep Direct-Use Feasibility Study - Shallow Temperature Survey

The objective of this project is to use a multi-disciplinary, three-tiered approach to assess the geothermal resource and determine the feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the various town and county facilities in Hawthorne, Nevada. This assessment directly targets a geothermal resource recently characterized by the Navy Geothermal Program Office (GPO) as part of a focused exploration and development campaign. Zip folder containing shallow temp survey data for the Hawthorne Geothermal area.

15 GEOTHERMAL ENERGY↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Fort Bliss Geothermal Area Data: Temperature profile, logs, schematic model and cross section

This dataset contains a variety of data about the Fort Bliss geothermal area, part of the southern portion of the Tularosa Basin, New Mexico. The dataset contains schematic models for the McGregor Geothermal System, a shallow temperature survey of the Fort Bliss geothermal area. The dataset also contains Century OH logs, a full temperature profile, and complete logs from well RMI 56-5, including resistivity and porosity data, drill logs with drill rate, depth, lithology, mineralogy, fractures, temperature, pit total, gases, and descriptions among other measurements as well as CDL, CNL, DIL, GR Caliper and Temperature files. A shallow (2 meter depth) temperature survey of the Fort Bliss geothermal area with 63 data points is also included. Two cross sections through the Fort Bliss area, also included, show well position and depth. The surface map included shows faults and well spatial distribution. Inferred and observed fault distributions from gravity surveys around the Fort Bliss geothermal area.

15 GEOTHERMAL ENERGY↗

High-Temperature Modal Survey of a Hot-Structure Control Surface

Ground vibration tests or modal surveys are routinely conducted for supporting flutter analysis for subsonic and supersonic vehicles; however, for hypersonic vehicle applications, thermoelastic vibration testing techniques are not well established and are not routinely performed for supporting hypersonic flutter analysis. New high-temperature material systems, fabrication technologies and high-temperature sensors expand the opportunities to develop advanced techniques for performing ground vibration tests at elevated temperatures. High-temperature materials have the unique property of increasing in stiffness when heated. When these materials are incorporated into a hot-structure, which includes metallic components that decrease in stiffness with increasing temperature, the interaction between the two materials systems needs to be understood because that interaction could ultimately affect the hypersonic flutter analysis. Performing a high-temperature modal survey will expand the research database for hypersonics and will help build upon the understanding of the dual material interaction. This paper will discuss the vibration testing of the Carbon-Silicon Carbide Ruddervator Subcomponent Test Article which is a truncated version of the full-scale X-37 hot-structure control surface. In order to define the modal characteristics of the test article during the elevated-temperature modal survey, two series of room-temperature modal test configurations had to be performed. The room-temperature test series included one with the test article suspended from a bungee cord (free-free) and the second with it mounted on the strongback (fixed boundary condition) in NASA Dryden's Flight Loads Lab large nitrogen test chamber.

Spivey, Natalie Dawn↗

High-Temperature Modal Survey of a Hot-Structure Control Surface

Ground vibration tests are routinely conducted for supporting flutter analysis for subsonic and supersonic vehicles; however, for hypersonic vehicles, thermoelastic vibration testing techniques are neither well established nor routinely performed. New high-temperature material systems, fabrication technologies and high-temperature sensors expand the opportunities to develop advanced techniques for performing ground vibration tests at elevated temperatures. When high-temperature materials, which increase in stiffness when heated, are incorporated into a hot-structure that contains metallic components that decrease in stiffness when heated, the interaction between those materials can affect the hypersonic flutter analysis. A high-temperature modal survey will expand the research database for hypersonics and improve the understanding of this dual-material interaction. This report discusses the vibration testing of the carbon-silicon carbide Ruddervator Subcomponent Test Article, which is a truncated version of a full-scale hot-structure control surface. Two series of room-temperature modal test configurations were performed in order to define the modal characteristics of the test article during the elevated-temperature modal survey: one with the test article suspended from a bungee cord (free-free) and the second with it mounted on the strongback (fixed boundary). Testing was performed in the NASA Dryden Flight Research Center Flight Loads Laboratory Large Nitrogen Test Chamber.

Spivey, Natalie D.↗

Hawthorne Nevada Deep Direct-Use Feasibility Study - Data Used for Geothermal Resource Conceptual Modeling and Power Capacity Estimates

This data submission includes several data components that were used to develop a conceptual model and power capacity-estimates of two low-temperature geothermal resources that define geothermal prospect A at Hawthorne, Nevada. Data are sourced from a combination of legacy publicly-available data and more recent data acquisition conducted by the US Navy Geothermal Program Office (2008-2013) and the Great Basin Center for Geothermal Energy at the University of Nevada, Reno (2008-2010). Data sets include compiled fluid geochemistry data, down-hole temperature logs for wells in the vicinity of prospect A, 2 meter temperature survey data, temperature-spinner logs acquired in well HWAAD-2A, fracture picks from image log data acquired in wells HWAAD-2 and HWAAD-3, and X-Ray Diffraction (XRD) analyses on cuttings from wells HWAAD-2A and HWAAD-3. These data have been reviewed for errors and inconsistencies, but it is possible that few errors could still remain. The resource conceptual model and power capacity estimates are included in the final report to the US Department of Energy, and are presented in a manuscript by Ayling and Hinz. A link to the manuscript published in Geothermics is linked below in this submission.

15 GEOTHERMAL ENERGY↗

Maui Gravity and Soil Gas Surveys

Contains a ground-based gravity survey of South Maui and a series of soil CO2 flux and temperature surveys encompassing Maui and the Big Island. The gravity survey was collected from approximately 284 km2 and consisted of 400 gravity stations with 400 m spacing. Locations were derived with full DGPS. Station and line location, Complete Bouger Anomaly, first vertical derivative and horizontal gradient maps were calculated and produced. The soil CO2 flux and temperature surveys were conducted on the islands of Hawaii and Maui in April and July 2010. Average soil temperatures were measured over 10 cm depth using a hand-held thermocouple. Soil CO2 fluxes were measured using a portable accumulation chamber instrument.

15 GEOTHERMAL ENERGY↗

Advancements in 3D Structural Analysis of Geothermal Systems

Robust geothermal activity in the Great Basin, USA is a product of both anomalously high regional heat flow and active fault-controlled extension. Elevated permeability associated with some fault systems provides pathways for circulation of geothermal fluids. Constraining the local-scale 3D geometry of these structures and their roles as fluid flow conduits is crucial in order to mitigate both the costs and risks of geothermal exploration and to identify blind (no surface expression) geothermal resources. Ongoing studies have indicated that much of the robust geothermal activity in the Great Basin is associated with high density faulting at structurally complex fault intersection/interaction areas, such as accommodation/transfer zones between discrete fault systems, step-overs or relay ramps in fault systems, intersection zones between faults with different strikes or different senses of slip, and horse-tailing fault terminations. These conceptualized models are crucial for locating and characterizing geothermal systems in a regional context. At the local scale, however, pinpointing drilling targets and characterizing resource potential within known or probable geothermal areas requires precise 3D characterization of the system. Employing a variety of surface and subsurface data sets, we have conducted detailed 3D geologic analyses of two Great Basin geothermal systems. Using EarthVision (Dynamic Graphics Inc., Alameda, CA) we constructed 3D geologic models of both the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, NV. These 3D models allow spatial comparison of disparate data sets in 3D and are the basis for quantitative structural analyses that can aid geothermal resource assessment and be used to pinpoint discrete drilling targets. The relatively abundant data set at Brady’s, ~80 km NE of Reno, NV, includes 24 wells with lithologies interpreted from careful analysis of cuttings and core, a 1:24,000 scale detailed geologic map and cross-sections, 2D seismic reflection profiles and other geophysical data, and downhole temperature data. The 3D geologic model based on these data consists of 61 fault planes, 25 distinct stratigraphic units, and 2 intrusive bodies. Geothermal fluids are produced from a left step-over/relay ramp within the Brady’s Fault Zone (BFZ). Under local stress conditions, fault segments that strike NNE-to-NE are most likely to slip and/or dilate, and therefore transmit geothermal fluids. The 3D model defines the locations of discrete fault intersections within the BFZ and indicates that the densest zones of structurally controlled fracture permeability are ~10-to-10s of meters in diameter and plunge ~55° NW-NNW beneath the heart of the BFZ step over. The locations of high intersection density, high fault slip and dilation tendency, high subsurface temperature, and lithologies known to support high fracture permeability are combined to produce 3D ‘fairway’ maps useful in both assessments of geothermal resource potential and for defining drilling targets. Astor Pass is located on the Pyramid Lake Paiute Reservation, ~80 km north of Reno, NV. It is a prospective ‘greenfield’ geothermal area, and thus subsurface data are relatively sparse. Available data include: two relatively deep wells (~1400 m) and one shallower well (~500 m) with lithologies interpreted from drill cuttings, several 2D seismic reflection profiles, a 1:24,000 scale geologic map and cross-section, a shallow temperature survey, and downhole temperature data. 3D modeling based on these data has defined 19 distinct fault planes and 16 stratigraphic units. Based on the stress field calculated from borehole breakouts, drilling induced tensile cracks and petal-centerline cracks in the two relatively deep wells, 3D slip and dilation tendency analysis indicates that northerly striking fault segments are most likely to slip and/or dilate, and therefore transmit geothermal fluids. Analysis of fault intersection density indicates that the highest density of structurally controlled permeability within the field lies in a narrow (10-to-10s of m) zone plunging moderately (~35°) to the NNW beneath Pleistocene tufa deposits. This zone of increased fracture density, which we interpret as the primary upflow zone, is controlled by the intersection of N-to-NNW striking normal faults and a WNW striking dextral fault zone and represents the most promising target for future drilling. Construction of a 3D geologic model involves integration of a variety of data into an internally consistent framework. A robust model allows for spatial comparison between the various types of data (structural, stratigraphic, geophysical, temperature, etc.) that are commonly used independently to site geothermal wells. Furthermore, highly detailed 3D geologic models provide the basis for additional quantitative analysis, including 3D fault slip and dilation tendency analysis and the precise location of structurally controlled permeability pathways. These analyses provide detailed information relating to the internal dynamics of geothermal systems and can mitigate the costs and risks of geothermal exploration and development by contributing to better well targeting and more accurate evaluations of resource potential.