Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron x-ray fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synchrotron X-ray fluorescence analyses of stratospheric cosmic dust - New results for chondritic and low-nickel particles

Trace element abundance determinations were performed using synchrotron X-ray fluorescence on nine particles collected from the stratosphere and classified as cosmic. Improvements to the Synchrotron Light Source allowed the detection of all elements between Cr and Mo, with the exceptions of Co and As, in our largest particle. The minor and trace element abundance patterns of three Ni-depleted particles were remarkably similar to those of extraterrestrial igneous rocks. Fe/Ni and Fe/Mn ratios suggest that one of these may be of lunar origin. All nine particles exhibited an enrichment in Br, ranging from 1.3 to 38 times the C1 concentration. Br concentrations were uncorrelated with particle size, as would be expected for a surface correlated component acquires from the stratosphere.

Flynn, G. J.↗

Trace element analyses of spheres from the melt zone of the Greenland ice cap using synchrotron X ray fluorescence

Synchrotron X-ray fluorescence spectra of unpolished iron and chondritic spheres extracted from sediments collected on the melt zone of the Greenland ice cap allow the analysis of Ni, Cu, Zn, Ga, Ge, Pb, and Se with minimum detection limits on the order of several parts per million. All detected elements are depleted relative to chondritic abundance with the exception of Pb, which shows enrichments up to a factor of 500. An apparent anticorrelation between the Ni-content and trace element concentration was observed in both types of spherules. The fractionation patterns of the iron and chondritic spheres are not complementary and consequently the two iron spheres examined in this study are unlikely to result from ejection of globules of Fe/Ni from parent chondritic micrometeoroids.

Chevallier, P.↗

Copper and nickel partitioning in iron meteorites

Trace element analyses using proton induced X-ray emission and synchrotron X-ray fluorescence have been made on metal and troilite from nine iron meteorites representing five geochemical groups. Nickel and copper distribution coefficients D (troilite/metal) vary by factors of 600 and 20, respectively, correlate positively with kamacite bandwidth and correlate negatively with bulk nickel content. Meteorites with bulk Ni of less than 10 percent have Cu-enriched troilite while those with Ni greater than 10 percent have Cu-depleted troilite. Since magmatic evolution and partial melting will produce Cu-enriched troilite only, the observation of Cu-depleted troilite in Ni-rich meteorites is evidence for subsolidus reequilibration, a process which reduces D(Cu) by transfer of Cu to exsolving metal. Elemental redistribution may have played an important role in establishing the present chemical trends in iron meteorites.

Sutton, S. R.↗

Cosmic dust particle densities - Evidence for two populations of stony micrometeorites

The existence of two populations of stony micrometeorites of distinctly different densities would result in significantly different orbital evolution properties for particles from each group. The densities inferred from deceleration of meteors in the earth's atmosphere suggest a substantial amount of the meteoric material has densities of 1 g/cu cm or less (Verniani, 1973). However, measurements of microcraters on lunar rock surfaces led Brownlee et al. (1973) to the conclusion that most micrometeoroids impacting the moon had densities in the 2-4 g/cu cm range, and low-density micrometeoroids were rare. The recovery of stony micrometeorites from the earth's stratosphere after atmospheric deceleration provides the opportunity to resolve the discrepancies. Here, the densities of 12 stony micrometeorites are determined, using synchrotron X-ray fluorescence to infer the particle mass and optical microscope measurements of the volumes. The particles fall into two distinct density groups, with mean values of 0.6 and 1.9 g/cu cm. The factor of 3 difference in the mean densities between the two populations implies differences in the orbital evolution time scales.

Flynn, G. J.↗

Chemical characterization of seven Large Area Collector particles by SXRF

Optical microscopy and synchrotron X-ray fluorescence (SXRF) are used to analyze the chemical composition of seven dark-appearing cosmic-dust particles obtained in the stratosphere during NASA Johnson Large Area Collector flights. The experimental setup and procedures are outlined, and the results are presented in extensive tables. Three of the particles had abundances similar to those of chondrites (except for low Ca values in one particle); two had a metallic appearance and spectra dominated by Fe and Zn; one contained Cu and Cr plus small amounts of Fe and Zn; and one had igneous-type abundances of minor and trace elements while containing all of the elements seen in chondritic particles, suggesting it may be of extraterrestrial origin.

Flynn, G. J.↗

SXRF determination of trace elements in chondrule rims in the unequilibrated CO3 chondrite, ALH A77307

The concentrations of Ni, Cu, Zn, Ga, Ge, and Se in five chondrule rims in the CO3 chondrite ALH A77307 (3.0) using the synchrotron x-ray fluorescence (SXRF) microprobe at Brookhaven National Laboratory were determined. The data show that the trace element chemistry of rims on different chondrules is remarkably similar, consistent with data obtained for the major elements by electron microprobe. These results support the idea that rims are not genetically related to individual chondrules, but all sampled the same reservoir of homogeneously mixed dust. Of the trace elements analyzed Zn and Ga show depletions relative to CI chondrite values, but in comparison with bulk CO chondrites all the elements are enriched by approximately 1.5 to 3.5 x CO. The high concentrations of the highly volatile elements Se and Ga and moderately volatile Zn (1.5 to 2 x CO) in rims show that matrix is the major reservoir of volatile elements in ALH A77307.

Brearley, Adrian J.↗

Trace element content of chondritic cosmic dust: Volatile enrichments, thermal alterations, and the possibility of contamination

Trace element abundances in 51 chondritic Interplanetary Dust Particles (IDP's) were measured by Synchrotron X-Ray Fluorescence (SXRF). The data allow us to determine an average composition of chondritic IDP's and to examine the questions of volatile loss during the heating pulse experienced on atmospheric entry and possible element addition due to contamination during atmospheric entry, stratospheric residence, and curation.

Flynn, G. J.↗

Multielement analysis of interplanetary dust particles using TOF-SIMS

Sections of three stratospheric particles (U2015G1, W7029*A27, and L2005P9) were analyzed with TOF-SIMS (Time Of Flight-Secondary Ion Mass Spectrometry) continuing our efforts to investigate the element distribution in interplanetary dust particles (IDP's) with high lateral resolution (approximately 0.2 micron), to examine possible atmospheric contamination effects, and to further explore the abilities of this technique for element analysis of small samples. The samples, previously investigated with SXRF (synchrotron X-ray fluorescence analysis), are highly enriched in Br (Br/Fe: 59 x CI, 9.2 x CI, and 116 x CI, respectively). U2015G1 is the IDP with the by far highest Zn/Fe-ratio (81 x CI) ever reported in chondritic particles.

Stephan, T.↗

Robust Extraction and Multi-Technique Analysis of Micrometeoroids Captured in Low Earth Orbit

The use of low-density silica aerogel as the primary capture cell technology for the NASA Discovery mission Stardust to Comet Wild-2 [1] is a strong motivation for researchers within the Meteoritics community to develop techniques to handle this material. The unique properties of silica aerogel allow dust particles to be captured at hypervelocity speeds and to remain partially intact. The same unique properties present difficulties in the preparation of particles for analysis. Using tools borrowed from microbiologists, we have developed techniques for robustly extracting captured hypervelocity dust particles and their residues from aerogel collectors[2-3]. It is important not only to refine these extraction techniques but also to develop protocols for analyzing the captured particles. Since Stardust does not return material to Earth until 2006, researchers must either analyze particles that are impacted in the laboratory using light-gasgun facilities [e.g. 41 or examine aerogel collectors that have been exposed in low-Earth orbit (LEO) [5]. While there are certainly benefits in laboratory shots, i.e. accelerating known compositions of projectiles into aerogel, the LEO capture particles offer the opportunity to investigate real particles captured under real conditions. The aerogel collectors used in this research are part of the NASA Orbital Debris Collection Experiment that was exposed on the MIR Space Station for 18 months [5]. We have developed the capability at the UCB Space Sciences Laboratory to extract tiny volumes of aerogel that completely contain each impact event, and to mount them on micromachined fixtures so that they can be analyzed with no interfering support (Fig.1). These aerogel keystones simultaneously bring the terminal particle and the particle track to within 10 m (15 g cm- ) of the nearest aerogel surface. The extracted aerogel wedges containing both the impact tracks and the captured particles have been characterized using the synchrotron total external reflection X-ray fluorescence (TXRF) microprobe at SSRL, the Nuclear Microprobe at LLNL, synchrotron infrared microscopy at the ALS facility at LBL and the NSLS at BNL, and the Total Reflection X-ray Fluorescence (TXRF) facility at SLAC.

Westphal, A. J.↗

Synchrotron radiation - Applications in the earth sciences

Synchrotron-radiation sources and their characteristics are overviewed along with recent synchrotron-based research on earth materials and future earth-science applications utilizing the next generation of synchrotron-radiation sources presently under construction. Focus is placed on X-ray scattering studies of earth materials (crystalline and noncrystalline) under ambient conditions, diffraction studies of earth materials at high pressures and/or temperatures, spectroscopic studies, primarily X-ray absorption spectroscopy, and spatially resolved X-ray fluorescence studies of compositional variations in earth materials. It is noted that other synchrotron-based methods, such as X-ray tomography and topography may become important in characterizing earth materials, while soft X-ray/vacuum ultraviolet radiation from synchrotron sources can be applied to problems involving the structural environments of low-atomic-number elements and the characterization of surface reactions of minerals with liquids and gases.

Bassett, W. A.↗

In situ trace element microanalysis

The use of particle-track-radiography and X-ray- fluorescence techniques in the in situ measurement of trace (less than 1000 ppm) elements in single mineral phases of polished sections is surveyed, and examples of their application to ordinary, carbonaceous and enstatite chondrites are provided. Radiographic methods surveyed include fission-track radiography (for U, Th, and Pu-244), alpha radiography using nuclear reactions (for Li and B), alpha autoradiography (for Bi and Pb), and beta autoradiography (for several elements in synthetic or biological samples). Two X-ray-fluorescence methods are compared: (1) photon-induced X-ray emission (PIXE), and (2) the potential use of synchrotron radiation. The latter is shown to allow much greater sensitivity than current PIXE technology and a much broader range of elements than particle-track radiography: the ppm analysis of 10-micron grains for all elements heavier than Na. These advantages are seen as balancing the high cost of accelerator use.

Burnett, D. S.↗

Experiments with phase transitions at very high pressure

Diamond cells were constructed for use to 1 Mbar. A refrigerator for cooling diamond cells was adapted for studies between 15 and 300 K. A cryostat for superconductivity studies between 1.5 to 300 K was constructed. Optical equipment was constructed for fluorescence, transmission, and reflectance studies. X-ray equipment was adapted for use with diamond cells. Experimental techniques were developed for X-ray diffraction studies using synchrotron radiation. AC susceptibility techniques were developed for detecting superconducting transitions. The following materials were studied: compressed solidified gases (Xe, Ar), semiconductors (Ge, Si, GaAs), superconductors (Nb3Ge, Nb3Si, Nb3As, CuCl), molecular crystals (I).

Spain, I. L.↗

X-ray observations of a flare in NGC4151 from OSO-8

The 2-60 keV flux from NGC4151 changed by a factor of two on a timescale of 1.5 days. No fluctuations were detected in excess of a factor of three on timescales less than four hours. During a total observation of approximately 11 days there were no statistically significant changes in spectral shape. The spectrum was fitted by a power law with photon index alpha approximately 1.42 + or - 0.06 and column density N sub H approximately 7.5 + or - 0.5 x 10 to the 22d power at/cu cm. A 2 sigma residual to this fit implies fluorescent Fe line emission with E. W. approximately 240 eV. Both synchrotron self-Compton and thermal Compton models are consistent with the X-ray data.

Mushotzky, R. F.↗

X-ray observations of a flare in NGC 4151 from OSO 8

The 2-60-keV flux from NGC 4151 has been observed to change by a factor of 2 on a time scale of 1.5 days. No fluctuations in excess of a factor of 3 are detected on time scales less than 4 hours. During a total observation of approximately 11 days there were no statistically significant changes in spectral shape. The spectrum can be fitted by a power law with photon index of about 1.42 + or - 0.06 and a hydrogen column density of approximately 7.5 + or - 0.5 x 10 to the 22nd power atoms/sq cm. A 2-sigma residual to this fit implies fluorescent Fe line emission with an equivalent width of about 240 eV. Both synchrotron self-Compton and thermal Compton models are consistent with the X-ray data.

Mushotzky, R. F.↗

Experiments with phase transitions at very high pressure

A diamond anvil cell is described which was developed for studying hydrogen and other materials to pressure above 100 PGa, including measurements at low temperature. The benefits of X-ray diffraction using synchrotron radiation and using a fixed anode source are examined as well as the optimization of X-ray diffraction at low temperature. A Ge diode detector was incorporated into apparatus for measuring optical absorption, reflectance, and fluorescence in order to enable luminescence studies and Raman spectra were obtained. Results of experiments on Si, Ge, GaP, InAs, hydrogen, benzene, nitrogen, graphite, and the superconductor CeCu2Si2 are given.

Spain, I. L.↗

The X-ray emitting galaxy Centaurus A

OSO-8 X-ray observations of Cen A in 1975 and 1976 are reported. The source spectrum can be well fitted in both years by a power law of number index 1.66 and absorption due to 1.3 by 10 to the 23rd power atoms/sq cm. The total flux varied by a factor of 2 between 1975 and 1976. In 1976 there were flux variations of approximately 40% on a time scale of days. Measurements of the 6.4-keV Fe fluorescent line and the 7.1-keV absorption edge imply Fe/H of approximately 0.000016. Simultaneous radio measurements show variation in phase with X-ray variability. Consideration of radio, millimeter, infrared, and X-ray data shows that all the data can be accounted for by a model in which the X-rays are due to a synchrotron self-Compton source embedded in a cold H2 cloud.

Mushotzky, R. F.↗

The X-ray emitting galaxy Cen-A

OSO-8 X-ray observations of Cen-A in 1975 and 1976 are reported. The source spectrum is well fit in both years by a power law of number index 1.62 and absorption due to 1.3 x 10 to the 23rd power at/sq cm. The total flux varied by a factor 2 between 1975 and 1976. In 1976 there were approximately 40% flux variations on a time scale of days. The 6.4 keV Fe fluorescent line and the 7.1 keV absorption edge were measured implying Fe/H approximately equals .000016. Simultaneous radio measurements show variation in phase with X-ray variability. Models considering radio, milimeter, IR and X-ray data show that all the data can be accounted for by a model in which the X-rays are due to a synchrotron self-Compton source embedded in a cold H(2) cloud.

Mushotzky, R. F.↗