SYNCHROTRON RADIATION AS THE SOURCE OF JUPITER'S POLARIZED DECIMETER RADIATION
Synchrotron radiation as the source of jupiters polarized decimeter radiation
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Synchrotron radiation as the source of jupiters polarized decimeter radiation
Synchrotron radiation as source of jupiters polarized decimeter radiation
Synchrotron radiation photoemission spectroscopy (SRPS) in the 1-4 KeV photon energy range is a useful tool for interface characterization. Results are presented of a series of studies of the near-interface region of Si/SiO2 which confirm that a bond strain gradient exists in the oxide as a result of lattice mismatch. These experiments include measurement of photoemission lineshape changes as a function of photon energy, corresponding changes in the electron escape depth near the interface, and surface extended X-ray absorption fine structure (SEXAFS) measurements directly indicating the shortening of the Si-Si second nearest neighbor distance in the near-interface region of the oxide.
Synchrotron spectra were computed for a hypothetical Saturn radiation belt. A monoenergetic distribution of relativistic electrons was assumed to exist in a toroidal volume in a dipole magnetic field aligned with the rotation axis. When synchrotron emission is added to the thermal component implied by observations at wavelengths shorter than 50 cm, the upturn in the total emission spectrum may be gradual to sharp, depending on the critical wavelength and the number density of radiating electrons. With the constraint of the pressure balance equation, the ranges of magnetic field intensity, and electron energy, and density were tabulated and nomographically illustrated. For several estimates of the magnetic field loading factor, the minimum surface magnetic field intensity and minimum electron number density were computed.
Changes to Jupiter's synchrotron radiation following the impact of Comet Shoemaker-Levy/9 are reported. Also, the consequences are reported for three possible mechanisms that might have caused those changes.
A technique is presented of using a single calibrated XUV detector for radiometric measurements of synchrotron radiation after the radiation passes through a monochromator that produces a mixture of first- and second-order diffracted radiation. Irradiance measurements are made with the synchrotron source operating at two different energies for the orbiting electrons. The known change in the spectral distribution produced by the electron energy change is used to calculate the flux in both first and second order. The dependence of the precision of these determinations on the two detected currents and on the detector calibration at both first- and second-order wavelengths is calculated. Experimental results using the National Bureau of Standards synchrotron (SURF-I) are presented, and anticipated results for the new NBS electron storage ring (SURF-II) are calculated.
Correction factors for spectral distribution and frequency range of radiating synchrotron electron motion
Artificial radiation belt synchrotron radiation calculation
Several synchrotron spectra are computed for a hypothetical Saturnian radiation belt. A monoenergetic distribution of relativistic electrons is assumed to exist in a toroidal volume in a dipole magnetic field aligned with the rotation axis. When synchrotron emission is added to the thermal component implied by observations at wavelengths shorter than 50 cm, the upturn in the total emission spectrum can become gradual to quite sharp depending on the critical wavelength and the number density of radiating electrons. As an example, the ranges of magnetic field intensity, and electron energy and density are tabulated for an estimate of the nonthermal component at the longest decimetric wavelength observation. The present observations are insufficient to determine the critical wavelength; but, for several estimates of the magnetic field loading factor, the minimum surface magnetic field intensity and minimum electron number density are computed.
The synchrotron radiation expected at Earth from the region L=2.9-5 R sub J of Jupiter's magnetosphere is calculated using the Pioneer 10 electron model. The result is approximately 21 flux units (f.u.). This value is to be compared with 6.0 + or - 0.7 f.u., the flux density of synchrotron radiation measured from Jupiter's entire magnetosphere in ground-based radio observations. Most of the radiation at 375 cm is emitted by electrons in the 1 to 10 MeV range. If the electron model used for calculations is cut off below 10 MeV, the calculated flux is reduced to approximately 4 f.u., a level compatible with the radio observations.
Synchrotron-radiation sources and their characteristics are overviewed along with recent synchrotron-based research on earth materials and future earth-science applications utilizing the next generation of synchrotron-radiation sources presently under construction. Focus is placed on X-ray scattering studies of earth materials (crystalline and noncrystalline) under ambient conditions, diffraction studies of earth materials at high pressures and/or temperatures, spectroscopic studies, primarily X-ray absorption spectroscopy, and spatially resolved X-ray fluorescence studies of compositional variations in earth materials. It is noted that other synchrotron-based methods, such as X-ray tomography and topography may become important in characterizing earth materials, while soft X-ray/vacuum ultraviolet radiation from synchrotron sources can be applied to problems involving the structural environments of low-atomic-number elements and the characterization of surface reactions of minerals with liquids and gases.
The microwave synchrotron radiation in the sub-cyclotron frequency region has been systematically validated as a diagnostic method for runaway electrons (>1 MeV) with radiation modeling and experiments on the DIII-D tokamak. Experimental observations reveal that sub-cyclotron frequency microwave radiation emerges only after runaway electrons are excited during plasma disruptions. Electron gyro-magnetic radiation modeling confirms that only runaway electrons with energies exceeding 1 MeV can emit radiation in the observed sub-cyclotron frequency band on DIII-D. The synchrotron Razin and Beaming effects are modeled in both the sub-cyclotron and standard Electron Cyclotron Emission (ECE) frequency region. Due to the pronounced beaming effect, the modeling supports that a standard ECE system is insensitive to synchrotron radiation from beamed runaway electrons (p ∥ >> p ⟂ ), but very sensitive to ECE radiation from isotropic suprathermal electrons (100 keV or less). DIII-D experiments further show that combining ECE and sub-cyclotron receivers reveals new insights into transient runaway dynamics during the plateau phase. Certain transient crash events appear only in the sub-cyclotron band or lead to opposite changes on the sub-cyclotron and standard ECE signals, supporting models where transient MHD events can exert a different effect on electrons of different energy levels. This novel diagnostic technique offers a powerful tool for studying and detecting runaway electron dynamics in both present-day and high-field future tokamaks. The diagnostic approach has been extrapolated to the SPARC tokamak, where sub-cyclotron radiation is predicted to respond sensitively and solely to runaway electrons during SPARC’s L-mode startup phase.
It is possible to use synchrotron radiation from electron synchrotrons and electron storage rings as an absolute source, especially in the VUV and soft X-ray regions where other standards are difficult to find. At the NBS, an electron storage ring (SURF-II) has been used to calibrate spectrometers and photometers utilized in solar and aeronomy research and in fusion plasma diagnostics. The radiation incident on these spectrometers can be calculated to uncertainties of 3%, and a technique to exactly determine the number of electrons orbiting in the ring is currently being developed to reduce this uncertainty. Detector calibrations between 5 and 55 nm are routinely performed at SURF-II and transfer standard detectors with 6-10% uncertainties over the range 5-254 nm are supplied.
An increasing interest in high quality and high current electron beams necessitates a thorough understanding and prediction of coherent synchrotron radiation effects. The self-interaction of charged particles in a beam undergoing synchrotron motion is a physically significant process that is all too often computationally intensive with very little analytical results to rely on for the general case. The coherent spectrum of this interaction is of utmost importance to the design of free electron lasers (FELs) and an accurate assessment is imperative for their design. This work presents a novel implementation to the numerical simulation of charged particle beams. The simulation is a self-consistent approach including the self-fields generated by the beam of which coherent synchrotron radiation effects are of primary interest. A particle-in-cell model is used where a planar beam sampled by point particles is deposited on an encompassing grid at each timestep. The electromagnetic fields are calculated on the grid using the retarded potentials according to causality. The electromagnetic forces from the fields are interpolated on each particle which in turn advance in time. The simulation is benchmarked against well-established results for coherent synchrotron radiation effects. In addition, studies are provided that show the convergence of simulation results for increasing resolution. A study into the transverse beam size effects on beam dynamics is performed as well as a proof of concept where the simulation is used by a genetic algorithm to optimize the design parameters of a beam lattice. The results of these studies in tandem verify the efficacy of the simulation for its practical use in accelerator design or the study of synchrotron radiation effects
Restoration of original synchrotron radiation formula
Synchrotron radiation rate from deexcitation of electrons in magnetic orbits of low quantum numbers, stressing electrons radiation in intense magnetic fields
Synchrotron radiation sources are now available throughout the world. The use of hard X-ray radiation from these sources for materials science is described with emphasis on diffraction imaging for material characterization. With the availability of synchrotron radiation, real-time in situ measurements of dynamic microstructural phenomena have been started. This is a new area where traditional application of X-rays has been superseded. Examples are chosen from limited areas and are by no means exhaustive. The new emerging information will, no doubt, have great impact on materials science and engineering.
The Jovian decimetric emission is caused by the combined emission of synchrotron radiation originating from the relativistic electrons trapped in Jupiter's 'Van Allen radiation belts' and thermal emission from the planet's atmosphere. Synchrotron radiation characteristics and variations (which provides insight into the physical properties of Jupiter's inner radiation belts) will be amplified and discussed.