Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SN 1987A after 18 Years: Mid-Infrared GEMINI and SPITZER Observations of the Remnant

We present high resolution 11.7 and 18.3 micron mid-IR images of SN 1987A obtained on day 6526 since the explosion with the Thermal-Region Camera and Spectrograph (T-ReCS) attached to the Gemini South 8m telescope. The 11.7 micron flux has increased significantly since our last observations on day 6067. The images clearly show that all the emission arises from the equatorial ring (ER). Nearly contemporaneous spectra obtained on day 6184 with the MIPS at 24 micron, on day 6130 with the IRAC in 3.6- 8 micron region, and on day 6190 with the IRS in the 12-37 micron instruments on board the Spitzer Space Telescope's show that the emission consists of thermal emission from silicate dust that condensed out in the red giant wind of the progenitor star. The dust temperature is 1662(sup +18) (sub -12) K, and the emitting dust mass is (2.6(sup +2.0 (sub -1.4)) x 10 (exp -6) M(solar). Lines of [Ne II] 12.82 micron and [Ne III] 15.56 pm are clearly present in the Spitzer spectrum, as well as a weak [Si II] 3 34.8 micron line. We also detect two lines near 26 micron which we tentatively ascribe to [Fe II] 25.99 pm and [0 IV] 25.91 micron. Comparison of the mid-IR Gemini 11.7 micron image with X-ray images obtained by Chandra, UV-optical images obtained by HST, and radio synchrotron images obtained by the ATCA show generally good correlation of the images across all wavelengths. Because of the limited resolution of the mid-IR images we cannot uniquely determine the location. or heating mechanism of the dust giving rise to the emission. The dust could be collisionally heated by the X-ray emitting plasma, providing a unique diagnostic of plasma conditions. Alternatively, the dust could be radiatively heated in the dense UV-optical knots that are overrun by the advancing supernova blast wave. In either case the dust-to-gas mass ratio in the circumstellar medium around the supernova is significantly lower than that in the general interstellar medium of the LMC, suggesting either a low condensation efficiency in the wind of the progenitor star, or the efficient destruction of the dust by the SN blast wave. Overall, we are witnessing the interaction of the SN blast wave with its surrounding medium, creating an environment that is rapidly evolving at all wavelengths. Continuous multiwavelength observations of SN 1987A such as these provide unique snapshots of the very early evolution of supernova remnants.

Bouchet, Patrice↗

Diffraction imaging (topography) with monochromatic synchrotron radiation

Structural information of special interest to crystal growers and device physicists is now available from high resolution monochromatic synchrotron diffraction imaging (topography). In the review, the importance of superior resolution in momentum transfer and in space is described, and illustrations are taken from a variety of crystals: gallium arsenide, cadmium telluride, mercuric iodide, bismuth silicon oxide, and lithium niobate. The identification and understanding of local variations in crystal growth processes are shown. Finally, new experimental opportunities now available for exploitation are indicated.

Steiner, Bruce↗

Streaking images that appear only in the plane of diffraction in undoped GaAs single crystals: Diffraction imaging (topography) by monochromatic synchrotron radiation

Streaking images restricted to the direction of the diffraction (scattering) vector have been observed on transmission through undoped GaAs. These disruption images (caused by the reduction of diffraction in the direction of observation) appear both in the forward and in Bragg diffracted directions in monochromatic synchrontron radiation diffraction imaging. This previously unobserved phenomenon can be explained in terms of planar defects (interfaces) or platelets which affects the absorption coefficient in anomalous transmission. Such regions of the crystal look perfect despite the presence of imperfections when the scattering vector is not perpendicular to the normal of the platelets. The observed crystallographic orientation of these interfaces strongly indicates that they are antiphase boundaries.

Kuriyama, Masao↗

Structural anomalies in undoped Gallium Arsenide observed in high resolution diffraction imaging with monochromatic synchrotron radiation

Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

Steiner, B.↗

Structural anomalies in undoped gallium arsenide observed in high-resolution diffraction imaging with monochromatic synchrotron radiation

Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

Steiner, B.↗

X-ray diffraction imaging (topography) of electroopticcrystals by synchrotron radiation

Information of special interest to crystal growers and device physicists now available from monochromatic synchrotron diffraction imaging (topography) is reviewed. Illustrations are taken from a variety of electro-optic crystals. Aspects of the detailed understanding of crystal growth processes obtainable from carefully selected samples are described. Finally, new experimental opportunities now available for exploitation are indicated.

Steiner, Bruce↗

Applications of synchrotron radiation to materials science: Diffraction imaging (topography) and microradiography

Synchrotron radiation sources are now available throughout the world. The use of hard X-ray radiation from these sources for materials science is described with emphasis on diffraction imaging for material characterization. With the availability of synchrotron radiation, real-time in situ measurements of dynamic microstructural phenomena have been started. This is a new area where traditional application of X-rays has been superseded. Examples are chosen from limited areas and are by no means exhaustive. The new emerging information will, no doubt, have great impact on materials science and engineering.

Kuriyama, Masao↗

Radio images of Jupiter's synchrotron radiation at 6, 20, and 90 cm

VLA observations of Jupiter's nonthermal radiation at wavelengths of 6, 20, and 90 cm are presented and compared. The spatial resolution in all images is 0.25 R(J) (R/J/ = Jovian radius). The brightness distribution of Jupiter is very similar at each of the three wavelengths, although the radiation peaks at 6 cm are at a slightly larger distance from Jupiter than those at the longer wavelengths. This is due to the higher rate of synchrotron radiation losses at the shorter wavelengths. Radial profiles through the images clearly show the presence of a 'shoulder' or flattening in the intensity at about 2.5 R(J) due to absorption effects by the satellite Amalthea. In addition, the so-called 'hot region' in Jupiter's radiation belts is clearly present at all three wavelengths: images of the planet at a cml (central meridian longitude) of about 30-40 deg show the radiation peak to the right of Jupiter to be much brighter than the peak at the left, while images at a cml of about 210-220 deg show the opposite. The difference in brightness between the two radiation peaks is similar at all three wavelengths.

De Pater, Imke↗

Crystal regularity with high-resolution synchrotron X-radiation diffraction imaging

New, high-resolution sources of X-radiation such as monochromatic synchrotron radiation beams with subarcsec divergence allow observation of regularities in a range of crystals with sufficient clarity for comprehensive analyses, whose results can deepen understanding of the nature of various crystal irregularities, their sources, and their effects on device performance. An account is presented of the results thus achievable with irregularities encountered in lattice orientation and strain, grain and subgrain boundaries, dislocations, domain boundaries, additional phases, and surface scratches. Significant achievements to date encompass the observation of critical anomalies in lead tin telluride, the reconciliation of disparate observations of GaAs, the determination of the performance effects of irregularities in mercuric iodide, and the characterization of the origins of crystal growth in bismuth silicon oxide.

Steiner, Bruce↗

Effect of a Synchrotron X-ray Microtomography Imaging Experiment on the Amino Acid Content of a CM Chondrite

X-ray microcomputed tomography and synchrotron X-ray microcomputed tomography (μCT) are becoming popular tools for the reconnaissance imaging of chondrites. However, there are occasional concerns that the use of μCT may be detrimental to organic components of a chondrite. Soluble organic compounds represent ~2–10% of the total solvent extractable carbon in CI and CM carbonaceous chondrites and amino acids are among the most abundant compounds in the soluble organic fraction. We irradiated two samples of the Murchison CM2 carbonaceous chondrite under conditions slightly harsher (increased beam exposure time) than those typically used for x-ray μCT imaging experiments to determine if detectable changes in the amino acid abundance and distribution relative to a nonexposed control sample occurred. After subjecting two meteorite portions to ionizing radiation dosages of 1.1 kiloGray (kGy) and 1.2 kGy with 48.6 and 46.6 keV monochromatic X-rays, respectively, we analyzed the amino acid content of each sample. Within analytical errors, we found no differences in the amino acid abundances or enantiomeric ratios when comparing the control samples (nonexposed Murchison) and the irradiated samples. We show with calculations that any sample heating due to x-ray exposure is negligible. We conclude that a monochromatic synchrotron X-ray μCT experiment at beamline 13-BM-D of the Advanced Photon Source, which imparts ~1 kGy doses, has no detectable effect on the amino acid content of a carbonaceous chondrite. These results are important for the initial reconnaissance of returned samples from the OSIRIS-REx and Hayabusa 2 asteroid sample return missions.

Jon M. Friedrich↗

Dynamical diffraction imaging (topography) with X-ray synchrotron radiation

By contrast to electron microscopy, which yields information on the location of features in small regions of materials, X-ray diffraction imaging can portray minute deviations from perfect crystalline order over larger areas. Synchrotron radiation-based X-ray optics technology uses a highly parallel incident beam to eliminate ambiguities in the interpretation of image details; scattering phenomena previously unobserved are now readily detected. Synchrotron diffraction imaging renders high-resolution, real-time, in situ observations of materials under pertinent environmental conditions possible.

Kuriyama, M.↗

High resolution synchrotron X-radiation diffraction imaging of crystals grown in microgravity and closely related terrestrial crystals

Irregularities in three crystals grown in space and in four terrestrial crystals grown under otherwise comparable conditions have been observed in high resolution diffraction imaging. The images provide important new clues to the nature and origins of irregularities in each crystal. For two of the materials, mercuric iodide and lead tin telluride, more than one phase (an array of non-diffracting inclusions) was observed in terrestrial samples; but the formation of these multiple phases appears to have been suppressed in directly comparable crystals grown in microgravity. The terrestrial seed crystal of triglycine sulfate displayed an unexpected layered structure, which propagated during directly comparable space growth. Terrestrial Bridgman regrowth of gallium arsenide revealed a mesoscopic structure substantially different from that of the original Czochralski material. A directly comparable crystal is to be grown shortly in space.

Steiner, Bruce↗

Search for Organic Nanoglobules in Carbonaceous Chondrites Using Microtomography

Primitive solar materials have various organic matters. In recent years, novel organic materials called organic nanoglobules of a few hundred micrometers in typical size were discovered in carbonaceous chondrites, IDPs, and comet 81P/Wild 2. The organic globules are spherical shape and in many cases with hollow structures. Composition of the globules are mainly aromatic carbon. The isotopic anomalies of SD and 6N 15 observed in the globules indicate that they were formed from photochemical reaction to ice particles at very low temperature environment, such as molecular clouds or outer protosolar disk. Aqueous alteration of organic matters and the gamma-ray irradiation to PAH are also suggested as alternative possible formation processes. If the globules are made from organic ice particles, the hollow regions of the globules are suggested to be once filled with volatile H20-rich organic ices, while if they were formed by aqueous alteration, the hollow regions should be filled with a fluid which caused the aqueous alteration. However, fluids in the globules have not been detected so far in the previous studies. If fluids were originally preserved in the hollows, they might be lost during destructive processes of sample separation or preparation for TEM observation. X-ray computed tomography (CT) is a nondestructive method which can determine 3-D internal structures of objects. SR (synchrotron radiation)-based imaging microtomography can give submicron spatial resolution [8] and was applied to micro textures in extraterrestrial materials, such as cometary grains captured by the Stardust mission [9]. If organic globules are observed non-destructively in carbonaceous chondrites by tomography, we can check the presence of fluids in the hollows. If fluids are preserved, we may analyze chemical and isotopic compositions of the fluids. The purpose of this study is to observe organic nanoglobules using imaging tomography for future analysis.

Matsumoto, T.↗

The metrology of spherical shells using synchrotron x ray microtomography

With recent advances in solid state imaging technology and the increasing availability of synchrotron x-ray radiation sources, synchrotron x-ray microtomography is emerging as a nondestructive technique for the evaluation of the structure and composition of small specimens with spatial resolution in the micron range. Synchrotron radiation offers the following advantages over conventional x-ray sources: high brightness, continuous emission which is tunable over a large energy range, faster data collection rates, and a highly collimated beam of large cross section permitting the illumination of large specimens. Synchrotron x-ray microtomography enables the structure of individual spheres to be evaluated in order to reveal the concentricity and sphericity of the internal void and the uniformity of the shell wall in the case of high quality spherical shells for Sandia National Laboratories' Inertial Confinement Fusion project.

Hmelo, Anthony B.↗

High resolution diffraction imaging of crystals grown in microgravity and closely related terrestrial crystals

Irregularities found in three crystals grown in space, in four crystals grown entirely on the ground were examined and compared. Irregularities were observed in mercuric iodide, lead tin telluride, triglycine sulfate, and gallium arsenide by high resolution synchrotron x radiation diffraction imaging. Radiation detectors made from mercuric iodide crystals grown in microgravity were reported to perform far better than conventional detectors grown from the same material under full gravity. Effort is now underway to reproduce these 'space' crystals, optimize their properties, and extend comparable superiority to other types of materials.

Steiner, B.↗

Model images of radio halos around supernova remnants

I present model calculations of profiles and two-dimensional images of the radio synchrotron emission of young supernova remnants, concentrating on observable effects of relativistic eletrons diffusing upstream of the shock wave. If the preshock electron scattering mean free path is sufficiently long, observable synchrotron halos outside the bulk of the radio emission can potentially result; their absence can constrain the mean free path from above. If scattering is primarily due, as expected, to Alfven waves with amplitude detla(B), the halo is expected to extend a distance of order r(sub g)c(delta(B)/B)(exp 2)/v(sub s) beyond the shock, where r(sub g) is the gyroradius of the electrons emitting at the observed frequency, B is the upstream magnetic field strength, v(sub s) is the shock velocity, and the amplitude delta(B) refers to wave with wavelength comparable to r(sub g), of order 10(exp 13) cm for typical supernova-remnant parameters. However, the detailed geometry of the halo varies with the assumptions about particle acceleration in the shock wave. I present an atlas of model profiles and images as a function of preshock diffusion length, of aspect angle between the magnetic field and the line of sight, and of other relevant parameters.

Reynolds, Stephen P.↗

Uncertainty Quantification of Classical Theories of Dendritic Growth Kinetics Applied to Nickel-Based Alloys

The solidification velocity in a model nickel-alloy single crystal during laser spot melting was recently characterized using synchrotron X-ray imaging. The measured solidification velocity was found to exceed the absolute stability threshold predicted by the Kurz-Giovanola-Trivedi (KGT) model. The discrepancies between the model and experiments motivate the further assessment of accurate material properties. This work quantifies the impact material property uncertainty has on model predictions of the absolute stability threshold velocities. Properties from the literature are reviewed and compared to those calculated using computational thermodynamics to provide uncertainty estimates on input properties to the KGT model. Global sensitivity analysis is used to quantify the influence of each uncertain input property on the predicted threshold velocity. This work supports the understanding of the nickel-alloy solidification during powder bed fusion additive manufacturing and identifies the solidification material properties that are the most important to assess from first-principles computations and experiments.

Computational thermodynamics↗