Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

3D Imaging of Microbial Biofilms: Integration of Synchrotron Imaging and an Interactive Visualization Interface

Understanding the interactions of structured communities known as “biofilms” and other complex matrixes is possible through the X-ray micro tomography imaging of the biofilms. Feature detection and image processing for this type of data focuses on efficiently identifying and segmenting biofilms and bacteria in the datasets. The datasets are very large and often require manual interventions due to low contrast between objects and high noise levels. Thus new software is required for the effectual interpretation and analysis of the data. This work specifies the evolution and application of the ability to analyze and visualize high resolution X-ray micro tomography datasets.

Biofilm Viewer↗

Diffraction and Transmission Synchrotron Imaging at the German Light Source ANKA--Potential Industrial Applications

Diffraction and transmission synchrotron imaging methods have proven to be highly suitable for investigations in materials research and non-destructive evaluation. The high flux and spatial coherence of X-rays from modern synchrotron light sources allows one to work using high resolution and different contrast modalities. This article gives a short overview of different transmission and diffraction imaging methods with high potential for industrial applications, now available for commercial access via the German light source ANKA (Forschungszentrum Karlsruhe) and its new department ANKA Commercial Service (ANKA COS, http://www.anka-cos.de)

36 MATERIALS SCIENCE↗

A farewell to arms: using X-ray synchrotron imaging to investigate autotomy in brittle stars

Autotomy, the self-induced loss of a body structure, occurs in every living class of echinoderms and is related to the remarkable regeneration capabilities of the group. It is particularly prevalent in brittle stars (Class Ophiuroidea). Autotomy is facilitated by mutable collagenous tissue (MCT), which undergoes nervous system-mediated changes in tensile stiffness, tensile strength, and viscosity. Previous investigations of autotomy have been based on observations of the external surface, surgical manipulation of internal structures, or data on the morphology of structures post-autotomy. We used fast phase-contrast X-ray synchrotron imaging to visualize full autotomy events in vivo in the arms of specimens of the brittle star Ophioderma brevispina . This method requires no chemical or surgical manipulation and enabled us to identify several key stages in the autotomy process. We used this methodology to observe critical changes within the internal structure of the arm as it transitions from a functional mechanical apparatus to a dysfunctional disarticulated state. This method is the first in which the full intersegmental plane of the arm can be observed during autotomy. In conclusion, it can be applied to visualize autotomy and motion in vivo in other brittle star taxa, as well as in other groups such as asteroids and arthropods.

59 BASIC BIOLOGICAL SCIENCES↗

Synchrotron imaging of the grasshopper tracheal system : morphological and physiological components of tracheal hypermetry.

As grasshoppers increase in size during ontogeny, they have mass specifically greater whole body tracheal and tidal volumes and ventilation than predicted by an isometric relationship with body mass and body volume. However, the morphological and physiological bases to this respiratory hypermetry are unknown. In this study, we use synchrotron imaging to demonstrate that tracheal hypermetry in developing grasshoppers (Schistocerca americana) is due to increases in air sacs and tracheae and occurs in all three body segments, providing evidence against the hypothesis that hypermetry is due to gaining flight ability. We also assessed the scaling of air sac structure and function by assessing volume changes of focal abdominal air sacs. Ventilatory frequencies increased in larger animals during hypoxia (5% O{sub 2}) but did not scale in normoxia. For grasshoppers in normoxia, inflated and deflated air sac volumes and ventilation scaled hypermetrically. During hypoxia (5% O{sub 2}), many grasshoppers compressed air sacs nearly completely regardless of body size, and air sac volumes scaled isometrically. Together, these results demonstrate that whole body tracheal hypermetry and enhanced ventilation in larger/older grasshoppers are primarily due to proportionally larger air sacs and higher ventilation frequencies in larger animals during hypoxia. Prior studies showed reduced whole body tracheal volumes and tidal volume in late-stage grasshoppers, suggesting that tissue growth compresses air sacs. In contrast, we found that inflated volumes, percent volume changes, and ventilation were identical in abdominal air sacs of late-stage fifth instar and early-stage animals, suggesting that decreasing volume of the tracheal system later in the instar occurs in other body regions that have harder exoskeleton.

43 PARTICLE ACCELERATORS↗

Bystander Effects During Synchrotron Imaging Procedures?

Using monochromatic beam and synchrotron phase-contrast technique at the biomedical beamline of the Italian synchrotron facility Elettra (SYRMEP), we have shown in a small animal model of malignant brain tumor that it is possible to obtain high-resolution images of very small tumors when they have developed from implanted tumor cells loaded with colloidal gold nanoparticles (GNP). All previous experiments were conducted in post-mortem samples. We have now designed a cell culture experiment to investigate the effects of synchrotron radiation with an energy and dose profile similar to that expected in our first in vivo imaging studies according to the protocol developed at SYRMEP.Materials and Methods: Culture flasks containing either gold-loaded or naieve C6 glioma cells were exposed to a dose of 0.5 Gy at 24 keV. The irradiated medium was aspirated and replaced with fresh growth medium. Twenty-four hours later this non-irradiated medium exposed to irradiated cells was aspirated, then added to non-irradiated C6 cells in order to investigate whether bystander effects are seen under the conditions of our image acquisition protocol. The irradiated medium was added to a number of other non-irradiated cell cultures. Cell counts were followed until 72 hrs after irradiation. Western blots were conducted with H2AX antibodies. This experiment was one of the first biomedical experiments conducted at BMIT, the new biomedical imaging and therapy beamline of the Canadian Light Source.Results: No significant differences in proliferation were seen between cells that were directly irradiated, exposed to irradiated medium or exposed to the non-irradiated 24-hr-medium from the irradiated cells. However, there was a tendency towards a higher number of double strand breaks in previously irradiated cells when they were exposed to non-irradiated medium that had been in contact with irradiated cells for 24 hrs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal evolution of runaway electrons from synchrotron images in Alcator C-Mod

We report in the Alcator C-Mod tokamak, relativistic runaway electron (RE) generation can occur during the flattop current phase of low density, diverted plasma discharges. Due to the high toroidal magnetic field (B 0 = 5.4 T), RE synchrotron radiation is measured by a wide-view camera in the visible wavelength range (λ ≈ 400–900 nm). In this paper, a statistical analysis of over one thousand camera images is performed to investigate the plasma conditions under which synchrotron emission is observed in C-Mod. In addition, the spatiotemporal evolution of REs during one particular discharge is explored in detail via a thorough analysis of the distortion-corrected synchrotron images. To accurately predict RE energies, the kinetic solver CODE is used to evolve the electron momentum-space distribution at six locations throughout the plasma: the magnetic axis and flux surfaces q = 1, 4/3, 3/2, 2, and 3. These results, along with the experimentally-measured magnetic topology and camera geometry, are input into the synthetic diagnostic SOFT to simulate synchrotron emission and detection. Interesting spatial structure near the surface q = 2 is found to coincide with the onset of a locked mode and increased MHD activity. Furthermore, the RE density profile evolution is fit by comparing experimental to synthetic images, providing important insight into RE spatiotemporal dynamics.

synthetic diagnostic↗

Spatiotemporal evolution of runaway electrons from synchrotron images in Alcator C-Mod

In the Alcator C-Mod tokamak, relativistic runaway electron (RE) generation can occur during the flattop current phase of low density, diverted plasma discharges. Due to the high toroidal magnetic field (B0 = 5.4 T), RE synchrotron radiation is measured by a wide-view camera in the visible wavelength range (~400-900 nm). In this paper, a statistical analysis of over one thousand camera images is performed to investigate the plasma conditions under which synchrotron emission is observed in C-Mod. In addition, the spatiotemporal evolution of REs during one particular discharge is explored in detail via a thorough analysis of the distortion-corrected synchrotron images. To accurately predict RE energies, the kinetic solver CODE [Landreman et al 2014 Comput. Phys. Commun. 185 847-855] is used to evolve the electron momentum-space distribution at six locations throughout the plasma: the magnetic axis and flux surfaces q = 1, 4/3, 3/2, 2, and 3. These results, along with the experimentally-measured magnetic topology and camera geometry, are input into the synthetic diagnostic SOFT [Hoppe et al 2018 Nucl. Fusion 58 026032] to simulate synchrotron emission and detection. Interesting spatial structure near the surface q = 2 is found to coincide with the onset of a locked mode and increased MHD activity. Furthermore, the RE density profile evolution is fit by comparing experimental to synthetic images, providing important insight into RE spatiotemporal dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

Runaway electron plateau current profile reconstruction from synchrotron imaging and Ar-II line polarization angle measurements in DIII-D

Abstract Current profile reconstructions are obtained for high current ( I p ≃ 550 kA) post-disruption runaway electron (RE) plateau plasmas in DIII-D. Two novel methods of measuring the RE current profile in high-current RE plateaus are introduced and compared: localization of the q = 2 rational surface using visible synchrotron emission (SE) imaging and the measurement of the polarization angle of line-integrated Ar-II line emission. The two methods are found to be consistent with each other within the data uncertainties. Different simulations of the RE current profile are compared with the measurements: the toroidal fluid RE model is found to best fit the data, within the measurement uncertainties. In addition to introducing two novel methods to measure the RE current profile and validating present simulation capabilities, this work demonstrates that instabilities can grow at q = 2 and q = 1 surfaces without necessarily causing a RE final loss instability. Numerical simulations are also presented to elucidate the role of these instabilities on synchrotron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemical Heterogeneity in PAN/LLZTO Composite Electrolytes by Synchrotron Imaging

Solid polymer/ceramic composite electrolytes are promising for batteries due to their attractive thermal stability and mechanical properties. Chemical heterogeneity in solid composite electrolytes, such as the inhomogeneity in the ceramic phase and salt distribution at the polymer/ceramic interface, is critical to the performance of solid composite electrolytes. However, such heterogeneity has not been well understood yet. In this work, we use Synchrotron-based X-ray fluorescence imaging (XRF) and Transmission X-ray Microscope (TXM) to image nanoscale chemical heterogeneity in polyacrylamide/Li 7+x La 3 Zr 2–x Ta x O 12 (LLZTO) composite electrolytes and investigate the effects of lithium salt, salt concentration, and plasticizer. We find that LLZTO particles show strong inter- and intra-particles chemical heterogeneities, and the off-stoichiometry of Zr in an LLZTO particle is unlikely to be only balanced by Ta substitution. Moreover, statistical analysis suggests that LiI tends to accumulate at the ceramic/polymer interface at a low concentration of 5 wt%, but no such tendency was observed in samples with 10 wt% LiI. However, composite electrolytes with LiTFSI show interfacial accumulation at both 5 wt% and 10 wt%. Furthermore, this report provides insight into element distributions in solid composite electrolytes, and we hope further researches can shed light on the connections between chemical heterogeneity and ionic transport pathway inside.

36 MATERIALS SCIENCE↗

Synchrotron Imaging of Pore Formation in Li Metal Solid-State Batteries Aided by Machine Learning

High-rate capable, reversible lithium metal anodes are necessary for next generation energy storage systems. In situ tomography of Li/LLZO/Li cells is carried out to track morphological transformations in Li metal electrodes. Machine learning enables tracking the lithium metal morphology during galvanostatic cycling. Nonuniform lithium electrode kinetics are observed at both electrodes during cycling. Hot spots in lithium metal are correlated with microstructural anisotropy in LLZO. Mesoscale modeling reveals that regions with lower effective properties (transport and mechanical) are nuclei for failure. Advanced visualization combined with electrochemistry represents an important pathway toward resolving non-equilibrium effects that limit rate capabilities of solid-state batteries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the effect of taurine supplementation on muscle taurine content in the mdx mouse model of Duchenne muscular dystrophy using chemically specific synchrotron imaging

Duchenne muscular dystrophy (DMD) is a lethal genetic muscle wasting disorder, which currently has no cure. Supplementation with the drug taurine has been shown to offer therapeutic benefit in the mdx model for DMD, however the mechanism by which taurine protects dystrophic muscle is not fully understood. Mdx muscle is deficient in taurine, however it is not known if this deficiency occurs in the extracellular space, in other cells present in the tissue (such as immune cells) or in the myofibre itself. Likewise, the tissue location of taurine enrichment in taurine treated mdx muscle is not known. In this study we applied X-ray absorption near edge spectroscopy (XANES) at the sulfur K-edge in an imaging format to determine taurine distribution in muscle tissue. XANES is the only technique currently capable of imaging taurine directly in muscle tissue, at a spatial resolution approaching myocyte cell size (20–50 μm). Using a multi-modal approach of XANES imaging and histology on the same tissue sections, we show that in mdx muscle, it is the myofibres that are deficient in taurine, and taurine supplementation ameliorates this deficiency. Increasing the taurine content of mdx myofibres was associated with a decrease in myofibre damage (as shown by the percentage of intact myofibres) and inflammation. These data presented here will help drive future studies to better elucidate the molecular mechanisms through which taurine protects dystrophic muscle; they also support the continued investigation of taurine as a therapeutic intervention for DMD.

59 BASIC BIOLOGICAL SCIENCES↗