Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “suspended particle device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electro-Optical Device with Tunable Transparency Using Colloidal Core/Shell Nanoparticles

Here, suspended particle devices (SPDs) adapted for controlling the transmission of electromagnetic radiation have become an area of considerable focus for smart window technology due to their desirable properties, such as instant and precise light control and cost-effectiveness. Here, we demonstrate a SPD with tunable transparency in the visible regime using colloidal assemblies of nanoparticles. The observed transparency using ZnS/SiO 2 core/shell colloidal nanoparticles is dynamically tunable in response to an external electric field with increased transparency when applied voltage increases. The observed transparency change is attributed to structural ordering of nanoparticle assemblies and thereby modifies the photonic band structures, as confirmed by the finite-difference time-domain simulations of Maxwell’s equations. The transparency of the device can also be manipulated by changing the particle size and the device thickness. In addition to transparency, structural colorations and their dynamic tunability are demonstrated using α-Fe 2 O 3 /SiO 2 core/shell nanomaterials, resulting from the combination of inherent optical properties of α-Fe 2 O 3 /SiO 2 nanomaterials and coloration due to their tunable structural particle assemblies in response to electric stimuli.

36 MATERIALS SCIENCE↗

System for concentrating and analyzing particles suspended in a fluid

Disclosed is a device for separating and concentrating particles suspended in a fluid stream by using dielectrophoresis (DEP) to trap and/or deflect those particles as they migrate through a fluid channel. The method uses fluid channels designed to constrain a liquid flowing through it to uniform electrokinetic flow velocities. This behavior is achieved by connecting deep and shallow sections of channels, with the channel depth varying abruptly along an interface. By careful design of abrupt changes in specific permeability at the interface, an abrupt and spatially uniform change in electrokinetic force can be selected. Because these abrupt interfaces also cause a sharp gradient in applied electric fields, a DEP force also can be established along the interface. Depending on the complex conductivity of the suspended particles and the immersion liquid, the DEP force can controllably complement or oppose the local electrokinetic force transporting the fluid through the channel allowing for manipulation of particles suspended in the transporting liquid.

47 OTHER INSTRUMENTATION↗

Apparatus and method for concentrating and filtering particles suspended in a fluid

Disclosed is a device for separating and concentrating particles suspended in a fluid stream by using dielectrophoresis (DEP) to trap and/or deflect those particles as they migrate through a fluid channel. The method uses fluid channels designed to constrain a liquid flowing through it to uniform electrokinetic flow velocities. This behavior is achieved by connecting deep and shallow sections of channels, with the channel depth varying abruptly along an interface. By careful design of abrupt changes in specific permeability at the interface, an abrupt and spatially uniform change in electrokinetic force can be selected. Because these abrupt interfaces also cause a sharp gradient in applied electric fields, a DEP force also can be established along the interface. Depending on the complex conductivity of the suspended particles and the immersion liquid, the DEP force can controllably complement or oppose the local electrokinetic force transporting the fluid through the channel allowing for manipulation of particles suspended in the transporting liquid.

47 OTHER INSTRUMENTATION↗

Laser beam deflection control: A concept

Improved control of laser beam deflection angles may result from new conceptual device. Reflectively coated magnetized particles are suspended in liquid-filled cell surrounded by two pairs of crossed electromagnetic coils and are selectively aligned by controlling magnetic fields. Ultrasonic energy source keeps particles suspended.

Garvie, C. L.↗

Mathematical models of continuous flow electrophoresis: Electrophoresis technology

Two aspects of continuous flow electrophoresis were studied: (1) the structure of the flow field in continuous flow devices; and (2) the electrokinetic properties of suspended particles relevant to electrophoretic separations. Mathematical models were developed to describe flow structure and stability, with particular emphasis on effects due to buoyancy. To describe the fractionation of an arbitrary particulate sample by continuous flow electrophoresis, a general mathematical model was constructed. In this model, chamber dimensions, field strength, buffer composition, and other design variables can be altered at will to study their effects on resolution and throughput. All these mathematical models were implemented on a digital computer and the codes are available for general use. Experimental and theoretical work with particulate samples probed how particle mobility is related to buffer composition. It was found that ions on the surface of small particles are mobile, contrary to the widely accepted view. This influences particle mobility and suspension conductivity. A novel technique was used to measure the mobility of particles in concentrated suspensions.

Saville, Dudley A.↗

An imaging co-axial tube electrodynamic trap for manipulation of charged particles

A tubular particle trapping device was designed and fabricated using two co-axial electrically conductive tubes with diameters of 5 mm and 7 mm, respectively. The device was integrated with an imaging camera and optical fiber bundle for real time monitoring of trapped particle motion. Charged microparticles of 3 to 50 m diameter can be suspended in air at ambient pressure using the device utilizing a quadrupole potential with an alternating voltage of amplitude 300 V to 750 V and frequency of 30 Hz to 140 Hz. Controlled trapping of a single particle or multiple particles can be achieved by tuning the voltage amplitude. The particle remained trapped when the entire assembly was translated or rotated. The device can be used as a manipulator for charged particle transport and repositioning.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Portable sample preparation and analysis system for micron and sub-micron particle characterization using light scattering and absorption spectroscopy

There is provided a method and device for remote sampling, preparation and optical interrogation of a sample using light scattering and light absorption methods. The portable device is a filtration-based device that removes interfering background particle material from the sample matrix by segregating or filtering the chosen analyte from the sample solution or matrix while allowing the interfering background particles to be pumped out of the device. The segregated analyte is then suspended in a diluent for analysis. The device is capable of calculating an initial concentration of the analyte, as well as diluting the analyte such that reliable optical measurements can be made. Suitable analytes include cells, microorganisms, bioparticles, pathogens and diseases. Sample matrixes include biological fluids such as blood and urine, as well as environmental samples including waste water.

47 OTHER INSTRUMENTATION↗

Metal sulfide electrodes and energy storage devices thereof

The present invention generally relates to energy storage devices, and to metal sulfide energy storage devices in particular. Some aspects of the invention relate to energy storage devices comprising at least one flowable electrode, wherein the flowable electrode comprises an electroactive metal sulfide material suspended and/or dissolved in a carrier fluid. In some embodiments, the flowable electrode further comprises a plurality of electronically conductive particles suspended and/or dissolved in the carrier fluid, wherein the electronically conductive particles form a percolating conductive network. An energy storage device comprising a flowable electrode comprising a metal sulfide electroactive material and a percolating conductive network may advantageously exhibit, upon reversible cycling, higher energy densities and specific capacities than conventional energy storage devices.

25 ENERGY STORAGE↗

Selective Emitters

This invention relates to a small particle selective emitter for converting thermal energy into narrow band radiation with high efficiency. The small particle selective emitter is used in combination with a photovoltaic array to provide a thermal to electrical energy conversion device. An energy conversion apparatus of this type is called a thermo-photovoltaic device. In the first embodiment, small diameter particles of a rare earth oxide are suspended in an inert gas enclosed between concentric cylinders. The rare earth oxides are used because they have the desired property of large emittance in a narrow wavelength band and small emittance outside the band. However, it should be emphasized that it is the smallness of the particles that enhances the radiation property. The small particle selective emitter is surrounded by a photovoltaic array. In an alternate embodiment, the small particle gas mixture is circulated through a thermal energy source. This thermal energy source can be a nuclear reactor, solar receiver, or combustor of a fossil fuel.

Chubb, Donald L.↗

Image computing techniques to extrapolate data for dust tracking in case of an experimental accident simulation in a nuclear fusion plant

In this paper, a preliminary shadowgraph-based analysis of dust particles re-suspension due to loss of vacuum accident (LOVA) in ITER-like nuclear fusion reactors has been presented. Dust particles are produced through different mechanisms in nuclear fusion devices, one of the main issues is that dust particles are capable of being re-suspended in case of events such as LOVA. Shadowgraph is based on an expanded collimated beam of light emitted by a laser or a lamp that emits light transversely compared to the flow field direction. In the STARDUST facility, the dust moves in the flow, and it causes variations of refractive index that can be detected by using a CCD camera. The STARDUST fast camera setup allows to detect and to track dust particles moving in the vessel and then to obtain information about the velocity field of dust mobilized. In particular, the acquired images are processed such that per each frame the moving dust particles are detected by applying a background subtraction technique based on the mixture of Gaussian algorithm. The obtained foreground masks are eventually filtered with morphological operations. Finally, a multi-object tracking algorithm is used to track the detected particles along the experiment. For each particle, a Kalman filter-based tracker is applied; the particles dynamic is described by taking into account position, velocity, and acceleration as state variable. The results demonstrate that it is possible to obtain dust particles’ velocity field during LOVA by automatically processing the data obtained with the shadowgraph approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle analyzing method and apparatus

The rapid chemical analysis of particles in aerosols can be accomplished using an apparatus which produces a controlled stream of individual particles from an environment, and another apparatus which vaporizes and ionizes the particles moving in free flight, for analysis by a mass spectrometer. The device for producing the stream of particles includes a capillary tube through which the air with suspended particles moves, a skimmer with a small opening spaced from an end of the capillary tube to receive particles passing through the tube, and a vacuum pump which removes air from between the tube and skimmer and creates an inflow of air and particles through the tube. The particles passing through the skimmer opening can be simultaneously vaporized and ionized while in free flight, by a laser beam of sufficient intensity that is directed across the path of the free flying particles.

Sinha, M. P.↗

Development of an Acoustic Sensor On-Line Gas Temperature Measurement in Gasifiers

This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-02NT41422 and specifically addresses Technical Topical Area 2 - Gasification Technologies. The project team includes Enertechnix, Inc. as the main contractor and ConocoPhillips Company as a technical partner, who also provides access to the SG Solutions Gasification Facility (formerly Wabash River Energy Limited), host for the field-testing portion of the research. The objective of this project was to adapt acoustic pyrometer technology to make it suitable for measuring gas temperature inside a coal gasifier, to develop a prototype sensor based on this technology, and to demonstrate its performance through testing on a commercial gasifier. The project was organized in three phases, each of approximately one year duration. The first phase consisted of researching a variety of sound generation and coupling approaches suitable for use with a high pressure process, evaluation of the impact of gas composition variability on the acoustic temperature measurement approach, evaluation of the impact of suspended particles and gas properties on sound attenuation, evaluation of slagging issues and development of concepts to deal with this issue, development and testing of key prototype components to allow selection of the best approaches, and development of a conceptual design for a field prototype sensor that could be tested on an operating gasifier. The second phase consisted of designing and fabricating a series of prototype sensors, testing them in the laboratory, and developing a conceptual design for a field prototype sensor. The third phase consisted of designing and fabricating the field prototype, and testing it in the lab and in a commercial gasifier to demonstrate the ability to obtain accurate measurements of gas temperature in an operating gasifier. Following the completion of the initial 3 year project, several continuations were awarded by the Department of Energy to allow Enertechnix to conduct extended testing of the sensor at the Wabash River facility. In February, 2008 the sensor was installed on the gasifier in preparation for a long-term test. During the initial testing of the sensor a stainless steel tube on the sensor failed and allowed syngas to escape. The syngas self-ignited and the ensuing small fire damaged some of the components on the sensor. There was no damage to the gasifier or other equipment and no injuries resulted from this incident. Two meetings were held to identify the root causes of the incident-one at Wabash River and one at Enertechnix. A list of recommended improvements that would have addressed the causes of the incident was created and presented to the Department of Energy on May 2, 2008. However, the DOE decided not to pursue these improvements and terminated the project. This report describes all of the activities conducted during the project and reports the findings of each activity in detail. The investigation of potential sound generation and coupling methods led to the selection of a reflected shock method which has been developed into a functioning prototype device. The principles of operation of this device and its performance characteristics are described in the report. Modeling of the attenuation of sound by suspended particles and by interaction of the sound pulses with the high temperature syngas inside the gasifier was conducted and the predictions of those models were used to determine the required sound pulse intensity to allow the sound pulses to be detected after passage through the gasifier environment. These modeling results are presented in this report. A study of the likely spatial and temporal variability of gas composition inside the gasifier was performed and the results of that study was used to predict the impact of that variability on the accuracy of the acoustic temperature method. These results are reported here. A design for a port rodding mechanism was developed to deal with potential slagging issues and was incorporated into the prototype sensor. This port rodding mechanism operated flawlessly during the field testing, but because these tests were performed in a region of the gasifier that experiences little slagging, the effectiveness of the rodding mechanism in dealing with highly slagging conditions was not fully demonstrated. This report describes the design and operation of the automated Gasifier Acoustic Pyrometer (autoGAP) which was tested at the Wabash River facility. The results of the tests are reported and analyzed in detail. All of the objectives of the initial R&D project were achieved and a field prototype acoustic pyrometer sensor was successfully tested at the Wabash River gasifier plant.

01 COAL, LIGNITE, AND PEAT↗

Particle-sampling statistics in laser anemometers Sample-and-hold systems and saturable systems

The effect of the data-processing system on the particle statistics obtained with laser anemometry of flows containing suspended particles is examined. Attention is given to the sample and hold processor, a pseudo-analog device which retains the last measurement until a new measurement is made, followed by time-averaging of the data. The second system considered features a dead time, i.e., a saturable system with a significant reset time with storage in a data buffer. It is noted that the saturable system operates independent of the particle arrival rate. The probabilities of a particle arrival in a given time period are calculated for both processing systems. It is shown that the system outputs are dependent on the mean particle flow rate, the flow correlation time, and the flow statistics, indicating that the particle density affects both systems. The results are significant for instances of good correlation between the particle density and velocity, such as occurs near the edge of a jet.

Edwards, R. V.↗

Separation of Yeast Cells from MS2 Viruses Using Acoustic Radiation Force

We report a rapid and robust separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing in a microfluidic device. A piezoelectric transducer (PZT) generates acoustic standing waves in the microchannel. These standing waves induce acoustic radiation force fields that direct microparticles towards the nodes (i.e., pressure minima) or the anti-nodes (i.e., pressure maxima) of the standing waves depending on the relative compressidensity between the particle and the suspending liquid.[1] For particles larger than 2 {micro}m, the transverse velocities generated by these force fields enable continuous, high throughput separation. Extensive work in the last decade [2-4] has demonstrated acoustic focusing for manipulating microparticles or biological samples in microfluidic devices. This prior work has primarily focused on experimental realization of acoustic focusing without modeling or with limited one-dimensional modeling estimates. We recently developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices.[1] Here we compare results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. Figure 1 shows a typical experimental acoustic focusing result for microparticles (diameter = 2.0 {micro}m) in a 500 {micro}m wide by 200 {micro}m deep microchannel. In this case, the PZT driving frequency and voltage are, respectively, 1.459 MHz and 6.6 V. The microparticles tightly focus (full width half maximum (FWHM) {approx}30 {micro}m) less than 30 s after the initiation of the acoustic field. We simulated the same geometry and operating conditions for comparison. The surface plot in Figure 2 illustrates the two-dimensional pressure field orthogonal to the flow direction (x-direction) from the simulation. The superimposed vector plot shows the acoustic radiation force in this plane. The dark regions and the light regions respectively represent the nodes and anti-nodes of the acoustic pressure field. The corresponding force field predicts acoustic focusing at the center of the microchannel, which is confirmed by the experimental results shown in Figure 1. We demonstrated the separation of Saccharomyces cerevisiae (typical cell size of 4-6 {micro}m depending on the cell growth stage, measured using a Coulter counter) and MS2 bacteriophage (typical diameter {approx}30 nm [5]) using acoustic focusing (Figure 3). A mixture of S. cerevisiae and MS2 labeled with Ribogreen was prepared and injected into one inlet of the microchip (i.e., half of the microchannel was filled with the sample). We varied driving voltages from 1.96 to 4.76 V, while fixing the driving frequency at 1.459 MHz and flow rate at 20 {micro}l/min. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. Increased driving voltages enhanced the acoustic focusing of the yeast cells thereby achieving good separation. We are able to achieve yields of > 80% and sample purities of > 90% in this continuous-flow sample preparation device.

42 ENGINEERING↗

AC electrokinetic manipulation of selenium nanoparticles for potential nanosensor applications

Highlights: ► Se nanoparticles were synthesized using a reverse-microemulsion process. ► AC osmotic fluid flow repulses the particles from electrode edges. ► Dielectrophoretic force attracts the particles to electrode edges. ► Dielectrophoresis electrode showed non-ohmic behavior. ► The device can potentially be used as a nanosensor. - Abstract: We report the AC electrokinetic behavior of selenium (Se) nanoparticles for electrical characterization and possible application as micro/nano devices. selenium Se nanoparticles were successfully synthesized using a reverse-microemulsion process and investigated structurally using X-ray diffraction and transmission electron microscope. Interdigitated castellated ITO and non-castellated platinum electrodes were employed for manipulation of suspended materials in the fluid. Using ITO electrodes at low frequency limits resulted in deposition of Se particles on electrode surface. When Se particles exposed to platinum electrodes in the 10 Hz–1 kHz range and V {sub p−p}> 8, AC osmotic fluid flow repulses the particles from electrode edges. However, in 10 kHz–10 MHz range and V {sub p−p}> 5, dielectrophoretic force attracts the particles to electrode edges. As the Se particle concentration increased, the trapped Se particles were aligned along the electric field line and bridged the electrode gap. The device was characterized and can potentially be useful in making micro/nano electronic devices.

36 MATERIALS SCIENCE↗

Measurements of size-segregated emission particles by a sampling system based on the cascade impactor

A special sampling system for measurements of size-segregated particles directly at the source of emission was designed and constructed. The central part of this system is a low-pressure cascade impactor with 10 collection stages for the size ranges between 15 nm and 16 {mu}m. Its capability and suitability was proven by sampling particles at the stack (100{sup o}C) of a coal-fired power station in Slovenia. These measurements showed very reasonable results in comparison with a commercial cascade impactor for PM10 and PM2.5 and with a plane device for total suspended particulate matter (TSP). The best agreement with the measurements made by a commercial impactor was found for concentrations of TSP above 10 mg m{sup -3}, i.e., the average PM2.5/PM10 ratios obtained by a commercial impactor and by our impactor were 0.78 and 0.80, respectively. Analysis of selected elements in size-segregated emission particles additionally confirmed the suitability of our system. The measurements showed that the mass size distributions were generally bimodal, with the most pronounced mass peak in the 1-2 {mu}m size range. The first results of elemental mass size distributions showed some distinctive differences in comparison to the most common ambient anthropogenic sources (i.e., traffic emissions). For example, trace elements, like Pb, Cd, As, and V, typically related to traffic emissions, are usually more abundant in particles less than 1 {mu}m in size, whereas in our specific case they were found at about 2 {mu}m. Thus, these mass size distributions can be used as a signature of this source. Simultaneous measurements of size-segregated particles at the source and in the surrounding environment can therefore significantly increase the sensitivity of the contribution of a specific source to the actual ambient concentrations. 25 refs., 3 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Diffusiophoresis in narrow channel flows

We report that flows containing suspended colloidal particles and dissolved solutes are found in a multitude of natural and man-made systems including hydraulic fractures, water filtration systems and microfluidic devices, e.g. those designed for biological or medical applications. In these types of systems, unexpected particle dynamics such as rapid particle transport and focusing has been observed in the presence of local solute gradients due to the cooperating or competing effects of fluid advection and particle diffusiophoresis, the latter driven by local chemical gradients. We develop analytical expressions for the fluid, solute and particle dynamics in long, narrow channels due to the combined influence of pressure-driven channel flow with diffusiophoretic and diffusioosmotic effects. The results confirm a rapid particle focusing effect that can be controlled by manipulating the particle, solute and flow properties, as well as the channel’s geometry and surface chemistry. Thus, we propose a new approach for performing microfluidic zeta potentiometry, as well as techniques for sorting, concentrating and/or capturing particles based on their sizes or zeta potentials. Lastly, we demonstrate that diffusioosmotic effects can be used to pump fluid against a pressure gradient.

42 ENGINEERING↗