Engineering PapersSearch

SEARCH · Engineering Papers

Results for “surface heat flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of local high-level, transient surface heat flux

This study is part of a continuing investigation to develop methods for measuring local transient surface heat flux. A method is presented for simultaneous measurements of dual heat fluxes at a surface location by considering the heat flux as a separate function of heat stored and heat conducted within a heat flux gage. Surface heat flux information is obtained from transient temperature measurements taken at points within the gage. Heat flux was determined over a range of 4 to 22 MW/sq m. It was concluded that the method is feasible. Possible applications are for heat flux measurements on the turbine blade surfaces of space shuttle main engine turbopumps and on the component surfaces of rocket and advanced gas turbine engines and for testing sensors in heat flux gage calibrators.

Liebert, Curt H.

Tidal and atmospheric forcing of the upper ocean in the Gulf of California. 2: Surface heat flux

Satellite infrared imagery and coastal meteorological data for March 1984 through February 1985 are used to estimate the net annual surface heat flux for the northern Gulf of California. The average annual surface heat flux for the area north of Guaymas and Santa Rosalia is estimated to be +74 W/sq m for the 1984-1985 time period. This is comparable to the +20-50 W/sq m previously obtained from heat and freshwater transport estimates made with hydrographic surveys from different years and months. The spatial distribution of the net surface heat flux shows a net gain of heat over the whole northern gulf. Except for a local maximum near San Esteban Island, the largest heat gain (+110-120 W/sq m) occurs in the Ballenas and Salsipuedes channels, where strong tidal mixing produces anomalously cold sea surface temperatures (SSTs) over much of the year. The lowest heat gain occurs in the Guayamas Basin (+40-50 W/sq m), where SSTs are consistently warmer. In the relatively shallow northern basin the net surface heat flux is farily uniform, with a net annual gain of approxmately +70 W/sq m. A local minimum in heat gain (approximately +60 W/sq m) is observed over the shelf in the northwest, where spring and summer surface temperatures are particularly high. A similar minimum in heat gain over the shelf was observed in a separate study in which historical SSTs and 7 years (1979-1986) of meteorological data from Puerto Penasco were used to estimate the net surface heat flux for the northern basin. In that study, however, the heat fluxes were higher, with a gain of +100 W/sq m over the shelf and +114 W/sq m in the northern basin. These larger values are directly attributable to the higher humidities in the 1979-1986 study compared to the 1984-1985 satellite study. High humidities reduce evaporation and the associated latent heat loss, promoting a net annual heat gain. In the norther Gulf of California, however, tidal mixing appears to play a key role in the observed gain of heat. Deep mixing in the island region produces a persistent pool of cold water which is mixed horizontally by the large-scale circulation, lowering surface temperatures over most of the northern gulf. These cold SSTs decrease evaporation by reducing the saturation vapor pressure of the overlying air. As a result, heat loss is substantially reduced, even when humidities are low. By removing heat from the surface, tidal mixing alters the time scale of air-sea interaction and reduces or possibly even inhibits the formation of deep water masses via convection.

Paden, Cynthia A.

The Surface Heat Flux as a Function of Ground Cover for Climate Models

Surface heat fluxes were examined as a function of surface properties and meteorological conditions in a 100 km x 100 km grid square at 1-km spatial resolution centered at the location of the First ISLSCP (International Satellite Land Surface Climatology Project) Field Experiment (FIFE), the Forest Ecosystem Dynamics site in central Maine, and a semiarid rangeland site around Walnut Gulch, Arizona. This investigation treats the surface heat flux variability within a GCM grid box to provide insight into methods for treating that variability in climate models. The heat fluxes were calculated using NOAA AVHRR and available meteorological data. The average heat fluxes that were estimated using the various area ground-cover representations were compared with the ensemble average heat fluxes for the entire area, which were assumed to be the best representation of the heat fluxes for the areas. Average beat fluxes were estimated for the entire 100 km x 100 km area based on a single ground-cover representation, and the mean error for the area sensible heat flux was about 10% and for the area latent heat flux, 21%. The estimation error was reduced, and in some cases significantly reduced, when the area heat fluxes were estimated by partitioning the area according to significant ground cover. The most significant effect of the partitioning was on the latent heat flux estimates.

Vukovich, Fred M.

Parameterization of surface heat fluxes above a forest with satellite thermal sensing

The authors discuss the feasibility of determining the surface flux of sensible heat from forests with surface temperatures measured by satellites together with temperature soundings in the unstable atmospheric boundary layer (ABL). The latent heat flux is derived from the sensible heat flux by means of the energy budget. The study makes use of data collected during HAPEX-MOBILHY (Hydrologic Atmospheric Pilot Experiment-Modelization du Bilan Hydrique). The methodology is based on turbulence similarity for the unstable ABL. The surface temperature data were derived from measurements by the advanced very high resolution radiometer (AVHRR) aboard the NOAA-9 satellite; the atmospheric profiles were obtained by radiosondes.

Brutsaert, Wilfried

Estimation of the average surface heat flux over an inhomogeneous terrain from the vertical velocity variance

An indirect method of estimating the surface heat flux from observations of vertical velocity variance at the lower mid-levels of the convective atmospheric boundary layer is described. Comparison of surface heat flux estimates with those from boundary-layer heating rates is good, and this method seems to be especially suitable for inhomogeneous terrain for which the surface-layer profile method cannot be used.

Eilts, M. D.

Parameterization of surface heat fluxes above forest with satellite thermal sensing and boundary-layer soundings

The paper is concerned with the feasibility of determining the surface flux of sensible heat from forest using surface temperatures measured by a satellite together with soundings of temperature aloft in the unstable atmospheric boundary layer. Consideration is also given to the effect of the spatial scale of the surface temperature measurement on the parameterization by means of the scalar roughness. The latent heat flux is derived from the sensible heat flux by means of the energy budget. The data used in the study have been obtained during the HAPEX-MOBILHY experiment of 1986. The approach is based on turbulence similarity for the unstable atmospheric boundary layer.

Brutsaert, Wilfried

A study of oceanic surface heat fluxes in the Greenland, Norwegian, and Barents Seas

This study examines oceanic surface heat fluxes in the Norwegian, Greenland, and Barents seas using the gridded Navy Fleet Numerical Oceanography Central surface analysis and the First GARP Global Experiment (FGGE) IIc cloudiness data bases. Monthly and annual means of net and turbulent heat fluxes are computed for the FGGE year 1979. The FGGE IIb data base consisting of individual observations provides particularly good data coverage in this region for a comparison with the gridded Navy winds and air temperatures. The standard errors of estimate between the Navy and FGGE IIb winds and air temperatures are 3.6 m/s and 2.5 C, respectively. The computations for the latent and sensible heat fluxes are based on bulk formulas with the same constant heat exchange coefficient of 0.0015. The results show extremely strong wintertime heat fluxes in the northern Greenland Sea and especially in the Barents Sea in contrast to previous studies.

Hakkinen, Sirpa

The effects of surface heat flux on plume spread and concentration - An assessment based on remote measurements

Satellite-derived surface heat-flux maps are presented in order to illustrate the large horizontal variations in surface heating that can occur over heterogeneous terrain. Results of plume-model studies published by Lamb (1978) and Willis and Deardorff (1978) were modified to show that the ground-level pollutant concentration depend closely upon the surface heat flux for the case of an elevated plume source during periods of free convection. It is suggested that remotely determined surface heat-flux patterns can be used in making plume dispersion calculations.

Carlson, T. N.

Dual Active Surface Heat Flux Gage Probe

A unique plug-type heat flux gage probe was tested in the NASA Ames Research Center 2x9 turbulent flow duct facility. The probe was fabricated by welding a miniature dual active surface heat flux gage body to the end of a hollow metal cylindrical bolt containing a metal inner tube. Cooling air flows through the inner tube, impinges onto the back of the gage body and then flows out through the annulus formed between the inner tube and the hollow bolt wall. Heat flux was generated in the duct facility with a Huels arc heater. The duct had a rectangular cross section and one wall was fabricated from 2.54 centimeter thick thermal insulation rigid surface material mounted onto an aluminum plate. To measure heat flux, the probe was inserted through the plate and insulating materials with the from of the gage located flush with the hot gas-side insulation surface. Absorbed heat fluxes measured with the probe were compared with absorbed heat fluxes measured with six water-cooled reference calorimeters. These calorimeters were located in a water-cooled metal duct wall which was located across from the probe position. Correspondence of transient and steady heat fluxes measured with the reference calorimeters and heat flux gage probe was generally within a satisfactory plus or minus 10 percent. This good correspondence was achieved even though the much cooler probe caused a large surface temperature disruption of 1000K between the metal gage and the insulation. However, this temperature disruption did not seriously effect the accuracy of the heat flux measurement. A current application for dual active surface heat flux gages is for transient and steady absorbed heat flux, surface temperature and heat transfer coefficient measurements on the surface of an oxidizer turbine inlet deflector operating in a space shuttle test bed engine.

Liebert, Curt H.

Analysis of shape of porous cooled medium for an imposed surface heat flux and temperature

The surface of a porous cooled medium is to be maintained at a specified design temperature while being subjected to uniform heating by an external source. An analytical method is given for determining the shape of the medium surface that will satisfy these boundary conditions. The analysis accounts for temperature dependent variations of fluid density and viscosity and for temperature dependent matrix thermal conductivity. The energy equation is combined with Darcy's law in such a way that a potential can be defined that satisfies Laplace's equation. All of the heat-transfer and flow quantities are expressed in terms of this potential. The determination of the shape of the porous cooled region is thereby reduced to a free-boundary problem such as in inviscid free jet theory. Two illustrative examples are carried out: a porous leading edge with coolant supplied through a slot and a porous cooled duct with a rectangular outer boundary.

Siegel, R.

A study of the evolution of the surface heat flux off the southeast coast of the United States during a cold air outbreak using satellite remote sensing data

Attention is given to the contribution of the marine boundary layer to storm development via a study of the evolution of the spatial distribution of the heat flux during a cold-air outburst (CAO) which occurred during the GALE Field Program period in a 550,000-sq-km area off the southeast coast of the United States. The study focuses on a CAO that occurred in the period February 24-26, 1986. During the CAO, the area averaged total surface heat flux ranged from 190 W/sq m to 1114 W/sq m. The high value was characterized by a lower average surface air and dew-point temperatures and a higher average surface wind speed. In general, the surface heat flux increased as the sea-surface temperatures on the continental shelf increased. It reached the maximum over the Gulf Stream, and then decreased over the eastern portions of the Gulf Stream and over the Sargasso Sea. The configuration conforms with some of the earlier findings of Bane and Osgoode (1989) and Blanton et al. (1989).

Vukovich, Fred M.

Large scale surface heat fluxes

The heat flux through the ocean surface, Q, is the sum of the net radiation at the surface, the latent heat flux into the atmosphere, and the sensible heat flux into the atmosphere (all fluxes positive upwards). A review is presented of the geographical distribution of Q and its constituents, and the current accuracy of measuring Q by ground based measurements (both directly and by 'bulk formulae') is assessed. The relation of Q to changes of oceanic heat content, heat flux, and SST is examined and for each of these processes, the accuracy needed for Q is discussed. The needed accuracy for Q varies from process to process, varies geographically, and varies with the time and space scale considered.

Sarachik, E. S.

Laminar free convection over two-dimensional bodies with uniform surface heat flux

A general analysis is presented of the steady nondissipative constant-property laminar boundary layer flow over a two-dimensional body of uniform surface heat flux situated in an infinite ambient fluid of undisturbed temperature. The analysis is then applied to a long horizontal circular cylinder. Numerical solutions to the universal functions associated with the first two terms in the derived series are given for Prandtl numbers 0.7, 1, 3, 5, 7, and 10. The results are compared with those obtained by Koh (1964) whose method is patterned after the Blasius-Frossling procedure for forced convection flow. The study reveals that Wilks' (1972) analysis concerning the external natural convection about two-dimensional bodies with constant heat flux is in error.

Lin, F. N.

Measurement of a surface heat flux and temperature

The Heat Flux Microsensor is a new sensor which was recently patented by Virginia Tech and is just starting to be marketed by Vatell Corp. The sensor is made using the thin-film microfabrication techniques directly on the material that is to be measured. It consists of several thin-film layers forming a differential thermopile across a thermal resistance layer. The measured heat flux q is proportional to the temperature difference across the resistance layer q= k(sub g)/delta(sub g) x (t(sub 1) - T(sub 2)), where k(sub g) is the thermal conductivity and delta (sub g) is the thickness of the thermal resistance layer. Because the gages are sputter coated directly onto the surface, their total thickness is less than 2 micrometers, which is two orders of magnitude thinner than previous gages. The resulting temperature difference across the thermal resistance layer (delta is less than 1 micrometer) is very small even at high heat fluxes. To generate a measurable signal many thermocouple pairs are put in series to form a differential thermopile. The combination of series thermocouple junctions and thin-film design creates a gage with very attractive characteristics. It is not only physically non-intrusive to the flow, but also causes minimal disruption of the surface temperature. Because it is so thin, the response time is less than 20 microsec. Consequently, the frequency response is flat from 0 to over 50 kHz. Moreover, the signal of the Heat Flux Microsensor is directly proportional to the heat flux. Therefore, it can easily be used in both steady and transient flows, and it measures both the steady and unsteady components of the surface heat flux. A version of the Heat Flux Microsensor has been developed to meet the harsh demands of combustion environments. These gages use platinum and platinum-10 percent rhodium as the thermoelectric materials. The thermal resistance layer is silicon monoxide and a protective coating of Al2O3 is deposited on top of the sensor. The superimposed thin-film pattern of all six layers is presented. The large pads are for connection with pins used to bring the signal out the back of the ceramic. In addition to the heat flux measurement, the surface temperature is measured with a platinum resistance layer (RTS). The resistance of this layer increases with increasing temperature. Therefore, these gages simultaneously measure the surface temperature and heat flux. The demonstrated applications include rocket nozzles, SCRAM jet engines, gas turbine engines, boiling heat transfer, flame experiments, basic fluid heat transfer, hypersonic flight, and shock tube testing. The laboratory involves using one of these sensors in a small combustion flame. The sensor is made on a 2.5 cm diameter piece of aluminum nitride ceramic.

Davis, R. M.

Remote estimation of the surface characteristics and energy balance over an urban-rural area and the effects of surface heat flux on plume spread and concentration

A one dimensional boundary layer model was used in conjunction with satellite derived infrared surface temperatures to deduce values of moisture availability, thermal inertia, heat and evaporative fluxes. The Penn State satellite image display system, a sophisticated image display facility, was used to remotely sense these various parameters for three cases: St. Louis, Missouri; the Land Between the Lakes, Kentucky; and Clarksville, Tennessee. The urban centers displayed the maximum daytime surface temperatures which correspond to the minimum values of moisture availability. The urban center of St. Louis and the bodies of water displayed the maximum nighttime surface temperatures which correspond to the maximum thermal inertia values. It is shown that moisture availability and thermal inertia are very much responsible for the formation of important temperature variations over the urban rural complex.

Dicristofaro, D. C.

An analytical and experimental study for surface heat flux determination

A numerical method by which data from a single embedded thermocouple can be used to predict the transient thermal environment for both high- and low-conductivity materials is described. The results of an investigation performed to verify the method clearly demonstrate that accurate transient surface heating conditions can be obtained from a thermocouple 1.016 cm from the surface in a low-conductivity material. Space Shuttle Orbiter thermal protection system materials having temperature- and pressure-dependent properties and typical Orbiter entry heating conditions were used to verify the accuracy of the analytical procedure. Analytically generated, as well as experimental, data were used to compare predicted and measured surface temperatures.

Williams, S. D.

Surface heat flux determination: An analytical and experimental study using a single embedded thermocouple

A numerical method by which data from a single embedded thermocouple can be used to predict the transient thermal environment for both high- and low-conductivity materials is described. The results of an investigation performed to verify the method clearly demonstrate that accurate, transient, surface heating conditions can be obtained from a thermocouple l.016 centimeters from the heating surface in a low-conductivity material. Space shuttle orbiter thermal protection system materials having temperature- and pressure-dependent properties, and typical orbiter entry heating conditions were used to verify the accuracy of the analytical procedure. Analytically generated, as well as experimental, data were used to compare predicted and measured surface temperatures.

Williams, S. D.

Predicting surface heat flux

Report presents technique involving single embedded thermocouple used to predict flux and temperature for high-or-low conductivity materials that have temperature-and-pressure dependent properties. Technique solves for heat rate and temperature at given surface at each time step, rather than for entire history. Newton-Raphson technique is used for temperature solutions; then quadratic fit is employed. Report contains representative graphs and tables.

Curry, D. M.