Engineering PapersSearch

SEARCH · Engineering Papers

Results for “superconducting radiofrequency cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Business Plan for a Domestic Supply of Superconducting Radiofrequency Cavities

Superconducting radiofrequency (SRF) cavities are critical components of modern particle accelerators. The industrialization of SRF technology in the U.S. has a long history, with several companies becoming interested in the technology in the past 30 years. However, there is currently no U.S. manufacturer with the capability to produce fully assembled, ready-to-test SRF cavities. A majority of these companies have either left the field or shut their doors. As a result, government-sponsored SRF accelerator projects in the U.S. largely rely on European vendors for the cavity supply. This presents not only a supply chain risk for scientific use cases, but also severely limits the commercialization of accelerator-based technologies. SRF accelerators have a range of strategic applications, including environmental remediation, semiconductor lithography, medical isotope production, and irradiation/sterilization. The nurturing of a domestic SRF industry is critical to maintaining U.S. economic competitiveness.

43 PARTICLE ACCELERATORS

Nb3Sn Superconducting Radiofrequency Cavity Fabricated by Sputter Deposition from a Stoichiometric Target

Nb$_3$Sn is a promising coating material for superconducting radiofrequency cavities in next-generation accelerators due to its higher superconducting transition temperature (~18.3 K) and superheating field (~400 mT), offering the potential to surpass the intrinsic performance limits of bulk niobium. We developed a sputter coating technique employing a stoichiometric target to fabricate Nb$_3$Sn films on the inner surfaces of niobium cavities. A Nb$_3$Sn tube target, prepared by growing a >20 m thick Nb$_3$Sn coating on the surface of a Nb tube via a Sn vapor diffusion process, was used in a DC cylindrical magnetron sputtering system. Approximately 170 nm thick Nb-Sn films were sputter-coated onto flat Nb substrates positioned to replicate the beam tube and equator regions of a 2.6 GHz cavity, followed by annealing at 950 °C for 3 hours to form Nb$_3$Sn. The composition, morphology, and structure of the annealed Nb$_3$Sn films were examined. Then, a ~1.2 m-thick film was sputter-coated onto the interior of a 2.6 GHz Nb cavity following the procedure developed for the flat samples. The cavity was subsequently annealed under the same conditions used for the flat samples. Cryogenic RF testing of the sputter-coated cavity demonstrated a T$_c$ of approximately 17.8 K, consistent with Nb$_3$Sn layer. Subsequently, the cavity underwent a light Sn recoating followed by a vapor diffusion Nb$_3$Sn coating process, achieving a quality factor of approximately 8.5 × 10$^9$ and an accelerating gradient of up to 11.3 MV/m at 4.2 K.

Shakel, Md Sharifuzzaman [Old Dominion U.; Jeffers

Investigation of hot-spots due to trapped flux in niobium superconducting radiofrequency cavities

One of the significant sources of residual losses in superconducting radio-frequency cavities is magnetic flux trapped during the cool-down due to the incomplete Messier effect. If the trapped vortices are non-uniformly distributed on the cavity surface, the temperature mapping revealed the “hotspots” at the location of high density of pinned vortices. Here, we performed a rf test on 1.3 GHz single cell cavity with the combination of the temperature mapping system. The temperature mapping reveled the development of the hot spots with the increase in rf field inside the cavity. When magnetic field is trapped locally on the surface of cavity, the hot-spots strength increase rapidly, showing the direct correlation of vortex induced hot spot and corresponding rf loss.

Accelerator Physics

Optimizing superconducting Nb film cavities by mitigating medium-field Q -slope through annealing

Niobium films are of interest in applications in various superconducting devices, such as superconducting radiofrequency cavities for particle accelerators and superconducting qubits for quantum computing. In this study, we address the persistent medium-field Q-slope issue in Nb film cavities, which, despite their high-quality factor at low RF fields, exhibit a significant Q-slope at medium RF fields compared to bulk Nb cavities. Traditional heat treatments, effective in reducing surface resistance and mitigating the Q-slope in bulk Nb cavities, are challenging for Nb-coated copper cavities. To overcome this challenge, we employed DC bias high-power impulse magnetron sputtering to deposit Nb film onto a 1.3 GHz single-cell elliptical bulk Nb cavity, followed by annealing treatments aimed at modifying the properties of the Nb film. In-situ annealing at 340 °C increased the quench field from 10.0 to 12.5 MV m −1 . Vacuum furnace annealing at 600 °C and 800 °C for 3 h resulted in a quench field increase of 13.5 and 15.3 MV m −1 , respectively. Further annealing at 800 °C for 6 h boosted the quench field to 17.5 MV m −1 . Additionally, the annealing treatments significantly reduced the field dependence of the surface resistance. However, increasing the annealing temperature to 900 °C induced a Q-switch phenomenon in the cavity. The analysis of RF performance and material characterization before and after annealing has provided critical insights into how the microstructure and impurity levels in Nb films influence the evolution of the Q-slope in Nb film cavities. Our findings highlight the significant roles of hydrides, high local misorientation, and lattice and surface defects in driving field-dependent losses. By strategically optimizing film properties and controlling impurity levels, we demonstrate a promising pathway to mitigate the medium-field Q-slope, paving the way for more efficient superconducting RF technologies.

Nb film

Healing Gradient Degradation in Nb3Sn SRF Cavities Using a Recoating Method

Despite having advantageous superconducting properties, Nb3Sn superconducting radiofrequency (SRF) cavities still have practical challenges compared to Nb SRF cavities due to the brittle nature of Nb3Sn. Performance degradation can occur when a Nb3Sn SRF cavity experiences mechanical stresses such as during handling and tuning of the cavity. In this study, we present a potential treatment for SRF cavities that have experienced stress induced performance degradation that involves a recoating procedure. The degraded cavity is coated with a small amount of Sn using a single step vapor-diffusion methodology. Using this approach we can recover a significant portion of the lost performance of a Nb3Sn SRF cavity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Decoupling of Nitrogen and Oxygen Impurities in Nitrogen Doped SRF Cavities

The performance of superconducting radiofrequency (SRF) cavities is critical to enabling the next generation of efficient high-energy particle accelerators. Recent developments have focused on altering the surface impurity profile through \textit{in-situ} baking, furnace baking, and doping to introduce and diffuse beneficial impurities such as nitrogen, oxygen, and carbon. However, the precise role and properties of each impurity are not well understood. In this work, we attempt to disentangle the role of nitrogen and oxygen impurities through time-of-flight secondary ion mass spectrometry of niobium samples baked at temperatures varying from 75-800 $^\circ$C with and without nitrogen injection. From these results, we developed treatments recipe that decouple the effects of oxygen and nitrogen in doping treatments. Understanding how these impurities and their underlying mechanisms drive further optimization in the tailoring of impurity profiles for high-performance SRF cavities.

43 PARTICLE ACCELERATORS

Decoupling of Nitrogen and Oxygen Impurities in Nitrogen Doped SRF Cavities

The performance of superconducting radiofrequency (SRF) cavities is critical for enabling the next generation of efficient high-energy particle accelerators. Recent developments have focused on altering the surface impurity profile through \textit{in-situ} baking, furnace baking, and doping to introduce and diffuse beneficial impurities such as nitrogen, oxygen, and carbon. However, the precise role and properties of each impurity are not well understood. In this work, we attempt to disentangle the role of nitrogen and oxygen impurities through time-of-flight secondary ion mass spectrometry using niobium cavity cutouts baked at temperatures varying from 120-800$^\circ$C with and without nitrogen injection. Understanding the underlying mechanisms behind these impurities will drive further optimization in the tailoring of nitrogen and oxygen profiles for high-performance SRF cavities.

43 PARTICLE ACCELERATORS

Co-sputter deposition of Nb₃Sn layer into SRF cavity using Nb-Sn composite target

Nb₃Sn, with its superior superconducting critical temperature (Tc ~18.3 K) and superheating field (Hsh ~400 mT), is considered a promising material for superconducting radiofrequency (SRF) cavities, offering enhanced cryogenic performance compared to bulk niobium cavities. A Nb₃Sn coating technique has been developed for Nb SRF cavities using co-sputtering of Nb-Sn composite target in a DC cylindrical magnetron sputtering system. The composite target configuration and discharge conditions for co-sputtering were optimized to deposit Nb-Sn films on flat Nb substrates, followed by annealing to form Nb₃Sn. Multiple strategies have been explored to improve the surface homogeneity of the Nb₃Sn coating, including optimizing a two-step annealing process, annealing in Sn vapor, and a light Sn recoating process. A 1.5 µm Nb-Sn co-sputtered film was deposited on the interior of a 2.6 GHz Nb SRF cavity and annealed at 600 °C for 6 h, followed by 950 °C for 1 h. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, confirming the formation of Nb₃Sn. Then, the annealed cavity underwent a light recoating treatment and attained a quality factor (Q0) of 8.5E+08 at 2.0 K.

Accelerator Physics

How nitrogen and oxygen shape SRF cavity performance

Nitrogen and oxygen-based surface treatments have revolutionized the performance of superconducting radiofrequency (SRF) cavities, enabling them to reach higher gradients and lower losses. However, the exact mechanisms by which these treatments improve cavity performance remain largely unknown. This work provides new insights into the role of nitrogen and oxygen in SRF cavity performance by using time-of-flight secondary ion mass spectrometry (TOF-SIMS) to precisely quantify the concentrations and depth profiles of these impurities within niobium cutouts. We correlate these impurity profiles with detailed cavity performance measurements, including surface resistance and quality factor, and compare our findings with predictions from BCS theory. The results demonstrate that while both nitrogen and oxygen enhance performance, ten times more oxygen is required to achieve the same reduction in BCS resistance as interstitial nitrogen. We present a potential model in which the observed variation arises from nitrogen's greater effectiveness in trapping hydrogen, thus reducing the formation of niobium hydrides and enhancing superconducting gap.

Hu, Hannah [Chicago U.]

Understanding the Role of Extrinsic Impurities in Bulk Nb SRF Cavities

High gradient and high quality factor superconducting radiofrequency (SRF) cavities are essential for efficient particle acceleration in next-generation accelerators. This work demonstrates that the superconducting performance of bulk niobium can be enhanced through a controlled introduction of interstitial oxygen and nitrogen. Thermal and chemical surface treatments modify the concentration and distribution of these impurities, enabling systematic tuning of SRF cavity performance. By combining cavity RF measurements with quantitative materials characterizations, we isolate the impact of impurity concentration on BCS surface resistance and identify the mechanisms by which interstitial impurities alter the superconducting properties of niobium. We find that nitrogen is an order of magnitude more effective than oxygen in reducing BCS resistance at 16 MV/m and that the reduction arises from a combination of mean free path optimization and superconducting gap enhancement. Using these insights, we develop a predictive model that estimates cavity performance directly from room temperature sample material studies, reducing the reliance on full-scale cryogenic tests for surface treatment development. We then apply this model to explore co-doping strategies, demonstrating that combining interstitial oxygen and nitrogen achieves a synergistic reduction in BCS resistance. These results establish co-doping as a viable path for the development of surface-engineered niobium for future high quality factor SRF applications.

Hu, Hannah [Chicago U.]

Sputter coating of Nb₃Sn into SRF cavity using stoichiometric target

Nb₃Sn has emerged as a leading alternative material due to its higher superconducting critical temperature (Tc) and superheating field (Hsh), promising a viable solution to the intrinsic performance limit currently faced by Nb superconducting radiofrequency (SRF) cavities. We sputter-coated Nb₃Sn inside Nb SRF cavity using a stoichiometric Nb₃Sn tube target in a DC cylindrical magnetron sputter coater. The target was fabricated by growing an estimated >20 μm thick Nb₃Sn layer on a Nb tube via Sn vapor diffusion using Jefferson Lab’s coating system. Approximately 150 nm thick Nb-Sn films were sputter-deposited onto flat Nb samples at positions representing the beam tubes and equator of a 2.6 GHz Nb cavity. Post-deposition annealing at 950 °C for 3 h resulted in the formation of Nb₃Sn. Microstructural analysis of the annealed films was carried out to investigate the morphology and structure of the Nb₃Sn films. Later, a 2.6 GHz Nb SRF cavity was coated with a ~1.2 μm thick sputtered Nb-Sn film using a stoichiometric Nb₃Sn target, followed by annealing. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, indicating the formation of Nb₃Sn. After a light Sn recoating treatment, the cavity achieved a quality factor (Q0) of 6.7E+08 at lower field at 2.0 K.

Accelerator Physics

Advances in understanding vacuum break dynamics in liquid helium-cooled tubes for accelerator beamline applications

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is essential for ensuring operational safety. This review summarizes experimental and theoretical work conducted in our cryogenics lab to address this issue. Systematic measurements were performed to study nitrogen gas propagation in uniform copper tubes cooled by both normal liquid helium (He I) and superfluid helium (He II). These experiments revealed a nearly exponential deceleration of the gas front, with stronger deceleration observed in He II-cooled tubes. To interpret these results, a one-dimensional (1D) theoretical model was developed, incorporating gas dynamics, heat transfer, and condensation mechanisms. The model successfully reproduced key experimental observations in the uniform tube system. However, recent experiments involving a bulky copper cavity designed to mimic the geometry of a superconducting radiofrequency (SRF) cavity revealed strong anisotropic flow patterns of nitrogen gas within the cavity, highlighting limitations in extrapolating results from simplified tube geometries to real accelerator beamlines. To address these complexities, we outline plans for systematic studies using tubes with multiple bulky cavities and the development of a two-dimensional (2D) model to simulate gas dynamics in these more intricate configurations. As a result, these efforts aim to provide a comprehensive understanding of vacuum breaks in particle accelerators and improve predictive capabilities for their operational safety.

Beamline tube

Co-Sputtering of Nb3Sn into SRF Cavity Using Composite Target and Optimizing Surface Homogeneity

Nb₃Sn coating method for superconducting radiofrequency (SRF) cavity has been developed following co-sputtering of Nb-Sn composite target using a DC cylindrical sputter coater. Deposition parameters and annealing strategies were optimized for uniform Nb₃Sn coating. 1.5 m Nb-Sn film was deposited onto 2.6 GHz Nb SRF cavity and annealed at 600 C for 6 h, followed by 950 C for 1 h. Cryogenic RF testing confirmed Nb₃Sn formation with Tc = 17.8 K. A post-annealing light Sn recoating process improved the cavity s performance, achieving Q₀ = 8.5 10⁸ at 2.0 K.

Shakel, M. S. [Old Dominion U.]

High-$Q_0$ treatment of CEBAF 1.5 GHz SRF cavities

The Continuous Electron Beam Accelerator Facility (CEBAF) was the first large-scale accelerator to employ superconducting radiofrequency (SRF) cavities for continuous-wave operation. Ongoing research and development efforts continue to focus on increasing the intrinsic quality factor (Q 0 ) of these cavities in order to reduce cryogenic losses while maintaining operational gradients. Here, in this work, we report on the application of high-Q 0 surface treatments to single-cell and multicell C100 and C75 style 1.5 GHz niobium cavities used in the CEBAF accelerator. Nitrogen infusion and oxygen alloying via medium-temperature baking were applied under heat-treatment constraints relevant to existing cavity hardware. Both processes yielded substantial improvements in Q 0 at moderate accelerating gradients, achieving values of approximately 2 × 10 10 at 2.07 K and 20 MV/m. The effectiveness of nitrogen infusion at reduced annealing temperatures and the successful extension of oxygen alloying to multicell cavities are demonstrated. These results establish viable pathways for implementing high-Q 0 treatments in CEBAF-compatible cavities and support future integration into cryomodules for reduced operational cryogenic load.

Dhakal, Pashupati [Thomas Jefferson National Accel

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659

Advancements in HF-free bipolar pulsed electropolishing for next-generation superconducting cavities

Hydrofluoric acid (HF)-free bipolar pulsed electropolishing (BPEP) offers an environmentally sustainable alternative to conventional Buffered Chemical Polishing (BCP) and Electropolishing (EP) techniques for superconducting radiofrequency (SRF) cavities. Recent studies at Jefferson Lab have demonstrated that a single-cell 1.3 GHz niobium cavity processed using HF-free BPEP achieved an accelerating gradient Eacc of 35 MV/m with a quality factor Q0 of 1E10 at 2 K, following extensive research and optimization. This talk will highlight the challenges encountered in developing this technique, key insights gained from experimental studies, and ongoing efforts to enhance its capabilities. In particular, we will explore its potential for refining Nb3Sn-coated niobium cavities via vapor diffusion techniques and for electroplating Nb3Sn films onto various cavity substrates, contributing to the advancement of high-performance SRF systems.

Tian, Hui [Thomas Jefferson National Accelerator F