Using Publish-Subscribe Methodology to Improve Water Data Sharing.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
The Accelerating Low-Income Financing and Transactions (LIFT) for Solar Access Everywhere project’s goal was to expand Low-to-Moderate Income (LMI) solar access for homeowners and renters. The LIFT project researched and gathered data on 453 LMI community solar project across the country. Following three years of research, the project delivered three groundbreaking research papers in June 2022, focused on 1) customer experience, 2) the growth of community solar programs, and 3) project-level financial best practices for serving LMI communities. These were followed by a user-friendly web-based Toolkit allowing users to interact with project data and key findings in November 2022. The customer experience research examined community solar subscribers’ primary motivations to join and remain satisfied with projects. Our research identified 453 projects across the country that dedicated some portion of the system capacity to LMI households. Seventeen of these projects participated in the LIFT customer experience research, allowing the project team to survey their customers and gain insight into how LMI subscribers feel about community solar and the programs that serve them. Subscribers in our sample indicated that the most critical issue that motivated them to participate in their program, however, was not savings but helping the environment. This was true for both LMI and non-LMI subscribers. Helping the environment was also the most important issue for LMI subscribers to measure how well their program was working for them. LIFT also explored how rapidly community solar has grown since its inception in 2006, publishing results in the Growth of U.S. Community Solar Serving LMI Households report. The results showed that community solar projects serving LMI households are one of the fastest growing segments of the solar industry. The report identifies and recommends ways developers should overcome real or perceived risks to LMI customer acquisition and subscriber management. Through the analysis of community solar project finance research, LIFT showed that most community solar projects serving LMI households are financed in the same ways mainstream community solar projects are financed. The value stacks and financial returns are no different, although LMI inclusion and participation rate varied across programs in our sample, ranging from between 10% and 100%. Based on the findings from the LIFT research, the team built a web-based user-friendly Toolkit, consisting of case studies, project finance best practices, and several tools built around the national dataset of 453 community solar projects that serve LMI households. These allow users to engage with the dataset in multiple ways; to explore the landscape of LMI community solar in the U.S., and to design community solar projects to optimize LMI inclusion, equity, and savings levels. The Toolkit also includes a library of LIFT-generated and LIFT-curated resources for users to learn more about how to best serve LMI communities through community solar. LIFT officially published the Toolkit on October 31, 2022, followed by a launch event (public webinar) on November 17, 2022. The core LIFT partners continue to engage in outreach and dissemination efforts to promote the LIFT Toolkit and research publications. Our driving motivation is to continue enabling solar developers to leverage the findings of this three-year research effort. By implication, the LIFT Toolkit is designed for use by utilities, energy service providers, and financiers or investors as a learning and decision-making tool to rapidly scale project models that optimize LMI inclusion and maximize real household savings.
A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.
Digital real time simulators (DRTS) are increasingly being used for the evaluation of power hardware and controller hardware in the laboratory prior to field deployment. Although DRTS are capable of simulating large models in real-time, it is challenging to visualize the results of large models without overdrawing or confounding the viewer. This paper provides an open-source framework for users to visualize their DRTS-based hardware-in-the-loop (HIL) experimental results in real-time. This proposed framework can be used by experimental test beds that can push data through an internet protocol based network. The proposed framework includes three main components. First, it includes the DRTS that generates and pushes the data to a relay. Second, it includes an application that serves multiple purposes, from data storage, testing, and translation of the data to a publisher/subscriber protocol. Finally, it includes libraries and applications that can be used to visualize the data by subscribing to the relay. This framework is available in open source, and it is tested using the HIL platform developed for testing advanced distribution management systems.
Over 2.7 GWac community solar has been installed in the U.S. as of 2020, and 44% (1.2 GWac ) were installed after 2018, which indicates a fast-growing segment of the solar market .Community solar refers to a system that allows customers to subscribe part of a solar PV system and receive credit on their electricity bills based on power production. Although the growth of community solar market makes accessing solar energy easier, low and moderate income (LMI) potential subscribers may still face challenges, such as no or low credit scores.To investigate the program designs and subscription considerations for LMI customers, we provide a summary of existing state-level low-income community solar policies, as well as estimated LMI capacity and subscribers in the U.S.
This presentation reviews trends in the national community solar market, with project data through 2019 and subscriber data through 2018. It summarizes data on community solar deployment over time, by state, and by project characteristics. It also examines how market factors have shaped community solar deployment and explores data on the community solar value proposition to subscribers.
Access to broadband or high-speed internet has taken on increased importance during the COVID-19 pandemic as many workplaces and schools shifted to a virtual environment. The Internet Access Index (IAI) was developed to better understand the challenges many households face in connecting to high-speed internet, whether due to lack of broadband availability from internet service providers or difficulties in subscribing to a broadband service. The IAI is calculated as the product of 3 factors. The first two factors gauge the quality and availability of high-speed internet and the third factor represents the public’s ability to subscribe to high-speed internet services. The IAI scores United States’ census tracts on a [0,1] scale, where values near 0 represent areas with less internet access and values approaching 1 represent more internet access. The maximum score (1.0) implies that all census blocks within a census tract have high speed internet available at the highest national speed (currently 1000 mbps), and that all households within the tract have a fixed broadband subscription of some type.
This presentation reviews trends in the national community solar market, with project and subscriber data through 2020. It summarizes data on community solar deployment over time, by state, and by project characteristics. It also examines how market factors have shaped community solar deployment and explores data on the community solar value proposition to subscribers, energy burden, and affordable housing benefits.
The Department of Energy (DOE) Water Power Technologies Office (WPTO) Triton Initiative supports the advancement of the marine energy (ME) industry through environmental monitoring research and technology development. This report presents the results and analysis of the Triton Initiative’s communications, outreach, and engagement (TCOE) efforts in fiscal year 2022. The primary TCOE goals were to: (1) educate and raise awareness of ME and the role of Triton's environmental monitoring research in supporting the industry; (2) build trust with audiences through transparent communications and outreach; and (3) evaluate and refine TCOE tactics based on feedback and metrics. To support these goals, the TCOE team used multiple platforms and approaches. Notable achievements include: (1) 12 newsletter issues sent to 185 subscribers with an average open rate of 56.4%. (2) 10 Triton Stories, resulting in 2,871 collective views contributing to 46% of all Triton website views. (3) 78 Triton-specific social media posts, which generated a total of 81,896 impressions, 1,037 post-clicks, and 7,814 video views. (4) 6,320 Triton website views with increased search engine optimization ranking in several categories. (5) 3 Triton researchers interviewed as guests on two different podcasts, Water Women and Big Deep: An Ocean Podcast. (6) A Triton special issue of the Journal of Marine Science and Engineering (JMSE) featuring 10 peer reviewed publications. All articles ranked in the top 25%, and two in the top 5%, for digital attention of all research outputs scored by Altmetric. (7) A seven-part webinar series called Triton Talks to share and discuss research and results from the research published in the JMSE special issue. Triton leveraged unique opportunities, particularly the JMSE special issue, to disseminate research results to end users, educate stakeholders, and gain valuable feedback. These concerted communication efforts increased exposure across platforms ultimately resulting in greater reach and access across audiences. Based on audience analyses of webinar attendees and newsletter subscribers, the TCOE team was able to successfully engage with general audiences, research partners, and ME stakeholders, including subject matter experts from government agencies, research organizations, and the regulatory community. The TCOE task established channels to gather input and create opportunities for two-way communication with people engaged with Triton’s outreach efforts. The feedback received will enable the TCOE team to support its goals for ongoing evaluation of outreach and engagement tools while continuing to build trust in the ME community and educate diverse audiences about the impactful research conducted by the Triton Initiative. This report is a Triton Initiative Fiscal Year 2022 Quarter 4 Milestone Deliverable due to the DOE WPTO Sponsor on 9/30/2022. An updated version to include data through 9/30/2022 will be delivered in October 2022.
The report presents an analysis of the considerations, costs, and benefits surrounding the implementation of utility consolidated billing in community solar programs while also exploring alternatives to achieve similar benefits in its absence. Consolidated billing simplifies the billing process for customers by combining all charges and credits associated with electricity service and community solar subscriptions into a single bill. The potential benefits of consolidated billing implementation include increased transparency, improved customer experience, and ultimately increased retention rates and decreased subscriber acquisition costs. Currently, community solar subscribers often receive two separate bills - one from the utility and one from a third-party community solar provider - potentially causing confusion. Consolidated billing seeks to resolve this by offering a unified bill, which, while beneficial to numerous stakeholders, presents administrative, technical, and financial hurdles that utilities and program administrators must address.
This presentation is an abridged version of the report it is based on that presents an analysis of the considerations, costs, and benefits surrounding the implementation of utility consolidated billing in community solar programs while also exploring alternatives to achieve similar benefits in its absence. Consolidated billing simplifies the billing process for customers by combining all charges and credits associated with electricity service and community solar subscriptions into a single bill. The potential benefits of consolidated billing implementation include increased transparency, improved customer experience, and ultimately increased retention rates and decreased subscriber acquisition costs. Currently, community solar subscribers often receive two separate bills - one from the utility and one from a third-party community solar provider - potentially causing confusion. Consolidated billing seeks to resolve this by offering a unified bill, which, while beneficial to numerous stakeholders, presents administrative, technical, and financial hurdles that utilities and program administrators must address.
With the increasing complexity of the distribution smart grid architecture, algorithms such as the fault location, isolation, and service restoration (FLISR) scheme rely on robust communications that are resilient to natural and man-made adverse conditions and exhibit robustness. Existing communications infrastructure for information exchange are centralized at the distribution management system, with very little autonomy or intelligence at the grid-edge. As a first step towards achieving grid-edge self-healing, this paper aims to bridge this shortcoming by implementing a centrally coordinated rules-based FLISR scheme and integrating it with Open Field Message Bus (OpenFMB), which is a flexible publish-subscribe architecture with the potential to enable point-to-multipoint communications and is more robust and resilient to natural and man-made adverse conditions. A proof of concept is developed to validate the centrally coordinated FLISR and OpenFMB mounted on an SEL-3360 computer that interacts with a simple feeder network of five SEL-651R relays, an SEL-3530 RTAC, and a hardware-in-the-loop testbed. Results demonstrate the efficacy of this approach in enabling direct, low-latency information exchange. OpenFMB's publish-subscribe data model also opens new ways to enable grid-edge interoperability among devices of different vendors interacting with different protocols.
Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.
Opportunistic pathogens such as Streptococcus pneumoniae secrete a giant metalloprotease virulence factor responsible for cleaving host IgA1, yet the molecular mechanism has remained unknown since their discovery nearly 30 years ago despite the potential for developing vaccines that target these enzymes to block infection. Here we show through a series of cryo-electron microscopy single particle reconstructions how the Streptococcus pneumoniae IgA1 protease facilitates IgA1 substrate recognition and how this can be inhibited. Specifically, the Streptococcus pneumoniae IgA1 protease subscribes to an active-site-gated mechanism where a domain undergoes a 10.0 Å movement to facilitate cleavage. Monoclonal antibody binding inhibits this conformational change, providing a direct means to block infection at the host interface. These structural studies explain decades of biological and biochemical studies and provides a general strategy to block Streptococcus pneumoniae IgA1 protease activity to potentially prevent infection.
In situ processing does not only allow scientific applications to face the explosion in data volume and velocity but also to address the time constraints of many simulation-analysis workflows by providing scientists with early insights about their applications at runtime. Multiple frameworks implement the concept of a data transport layer (DTL) to enable such in situ workflows. These tools are very versatile, directly or indirectly access the data generated on the same node, another node of the same compute cluster, or a completely distinct node, and allow data publishers and subscribers to run on the same computing resources or not. This versatility puts on researchers the onus of taking key decisions related to resource allocation and how to transport data to ensure the most efficient execution of their in situ workflows. However, domain scientists and workflow practitioners lack the appropriate tools to assess the respective performance of particular design and deployment options. In this paper we introduce a versatile simulated DTL designed to provide researchers with insights on the respective performance of different execution scenarios of in situ workflows. This open-source, standalone library builds on the SimGrid toolkit and can be linked to any SimGrid-based simulator. It facilitates the evaluation of the performance behavior, at scale, of different data transport configurations and the study of the effects of resource allocation strategies. We demonstrate the scalability, versatility, and accuracy of this simulated DTL by reproducing the execution of two synthetic benchmarks and of a real-world in situ workflow composed of an MPI application and a parallel data analysis. Results of simulations run on a single core show that the proposed library can simulate the interactions of tens of thousands of simulated processes deployed on two interconnected commodity clusters in a few seconds, and the execution by a thousand simulated processes of an in situ workflow in less than three minutes.
Cyber landscape evolves rapidly. Internet of Things (IoT) and Edge Computing (EC) have rapidly become an integral part of the modern computing infrastructure. It is expected that there will be more than 50 billion active and connected IoT devices by 2025 [1]. Pervasive IoT/EC creates unprecedented opportunities bridging the gap between previously segregated cyber and physical spaces. However, this progress also brings along new security challenges. IoT devices typically have limited computation, communication, and storage resources. This leads to security architecture designs such as using symmetric keys for group communication. While secure and efficient in stable network settings, symmetric key solutions are ill-adapted for IoT's highly dynamic device mobility behavior and frequent group membership turnover. Whenever IoT members leave a group, the known symmetric keys cannot be made forgotten, posing a serious vulnerability. This leads to frequent re-groupings that require expensive re-authentication, key regeneration, and key redistribution in order to maintain IoT/EC security. We present a novel symmetric key management framework that integrate an Incremental Threshold Scheme (ITS) cryptographical function into communication protocol's key rotation mechanism to allow for secure and efficient symmetric key communication group member node revocation. This ITS-enabled key management framework alleviates the need of frequent and expensive re-grouping and re-keying needed by today's large and dynamic IoT/EC operations. We further applied this ITS-enabled key management framework to a distributed IoT/EC-integrated publish and subscribe framework for applicability validation.
This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.
Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.