Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “strain gage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High temperature strain gage apparent strain compensation

Once an installed strain gage is connected to a strain indicating device and the instrument is balanced, a subsequent change in temperature of the gage installation will generally produce a resistance change in the gage. This purely temperature-induced resistance will be registered by the indicating device as a strain and is referred to as 'apparent strain' to distinguish it from strain due to applied stress. One desirable technique for apparent strain compensation is to employ two identical gages with identical mounting procedures which are connected with a 'half bridge' configuration where gages see the same thermal environment but only one experiences a mechanical strain input. Their connection in adjacent arms of the bridge will then balance the thermally induced apparent strains and, in principle, only the mechanical strain remains. Two approaches that implement this technique are discussed.

Holmes, Harlan K.↗

Application of strain gages to measure adhesive strains through the thickness of an adhesively-bonded stiffened strip

The purpose of the study is to measure the through-the-thickness strain distribution in an adhesively bonded stiffened strip subject to four-point bending and to compare the distribution with predicted results. Small-strain gages are used for measuring the normal strain in the adhesive layer of the strip. A total of 16 120-ohm encapsulated strain gages were mounted on the adhesive layer, and the specimen was loaded quasi-statistically and never to failure. Both the experimental and analytical results show good correlation and, in particular, a high strain gradient acting near the edge of the adhesive layer.

Lopez, O. F.↗

A resistance strain gage with repeatable apparent strain to 800 C

Experimental PdCr temperature-compensated resistance static-strain gages are described. The gages are developed in both fine-wire and thin-film forms. It is found that a PdCr wire strain gage coated with a flame-sprayed mixture of alumina and 4 wt pct zirconia demonstrates the smallest variation in and the best repeatability of apparent strain among the existing gages used at temperatures up to 800 C. Results of preliminary tests indicate uncompensated uncoated thin-film gages have potential usefulness at temperatures up to 1000 C.

Lei, J.-F.↗

Strain gage

A strain gage particularly suited for use in detecting and measuring mechanically induced strain in thermally strained specimens including an elongated link, adapted to be fixedly secured to the surface of a specimen, having thermal expansion characteristics matched with those of the specimen, and characterized by a differential capacitor employed for detecting strain induced motion as such motion is effected between the link and the surface of the specimen.

Harting, Darrell R.↗

High Temperature Capacitive Strain Gage

Capacitive strain gages designed for measurements in wind tunnels to 2000 F were built and evaluated. Two design approaches were followed. One approach was based on fixed capacitor plates with a movable ground plane inserted between the plates to effect differential capacitive output with strain. The second approach was based on movable capacitor plates suspended between sapphire bearings, housed in a rugged body, and arranged to operate as a differential capacitor. A sapphire bearing gage (1/4 in. diameter x 1 in. in size) was built with a range of 50,000 and a resolution of 200 microstrain. Apparent strain on Rene' 41 was less than + or - 1000 microstrain from room temperature to 2000 F. Three gage models were built from the Ground Plane Differential concept. The first was 1/4 in. square by 1/32 in. high and useable to 700 F. The second was 1/2 in. square by 1/16 in. high and useable to 1440 F. The third, also 1/2 in. square by 1/16 in. high was expected to operate in the 1600 to 2000 F range, but was not tested because time and funding ended.

Wnuk, Stephen P., Jr.↗

Experimental Evaluation of White Light Fabry-Perot Interferometry Fiber-Optic Strain Gages when Measuring Small Strains

An experimental study was conducted to evaluate whether fiber optic strain gages (FOSG) are "better" sensors than typical foil gages. A particularly attractive feature of FOSG was their specified resolution of 0.01% of full-scale (0.1 micro strain for 1000 micro strain full-scale). This feature would make FOSG practical tank level sensors, by measuring very small strains on the support structure of a tank. A specific application in mind was to measure liquid oxygen tank level, with support beams that were predicted to contract approximately 11 micro strain as the tank goes from empty to full. Among various fiber optic technologies currently available, Fabry-Perot Interferometry using white light was selected. This technology exhibits highly desirable feature such as absolute strain measurement, linearity over its full-scale, and temperature compensation. However, experiment results suggest that the resolution is 0.8 micro strain, at best, calibration from one sensor to another can be off by 2.4 - 11.2%, and that temperature compensation is not fully predictable, with errors of up to 3.5 micro strain over an 11C range. Hence, when compared with classic foil gages, FOSG possess less accuracy, similar resolution and repeatability (precision), and superior linearity over their entire operating range. They are immune to EMI and their signals suffer minimal degradation over long distances. It is also expected that drift with time will be minimal in FOSG whereas the gage factor of foil sensors changes over time when exposed to varying environmental conditions. In conclusion, FOSG are "better" than foil gages as long as the application allows calibration of individual units as installed for operation.

St.Cyr, William↗

High-Temperature, Thin-Film Strain Gages Improved

Conventional resistance strain gage technology uses "bonded" strain gages. These foil or wire gages are bonded onto the surface of the test article with glue, ceramic cements, or flame-sprayed ceramics. These bonding agents can, in some instances, limit both the degree of strain transmission from the test structure to the gage and the maximum working temperature of the gage. Also, the bulky, bonded gage normally disrupts aerodynamic gas flow on the surface of the test structure because of its intrusive character. To respond to the urgent needs in aeronautic and aerospace research where stress and temperature gradients are high, aerodynamic effects need to be minimized, and higher operational temperatures are required, the NASA Lewis Research Center developed a thin film strain gage. This gage, a vacuum-deposited thin film formed directly on the surface of a test structure, operates at much higher temperatures than commercially available gages do and with minimal disruption of the aerodynamic flow. The gage uses an alloy, palladium-13 wt % chromium (hereafter, PdCr), which was developed by United Technologies Research Center under a NASA contract. PdCr is structurally stable and oxidation resistant up to at least 1100 C (2000 F); its temperature-induced resistance change is linear, repeatable, and not sensitive to the rates of heating and cooling. An early strain gage, which was made of 25-micrometer-diameter PdCr wire and demonstrated to be useable to 800 C, won an R&D 100 award in 1991. By further improving the purity of the material and by developing gage fabrication techniques that use sputter-deposition, photolithography patterning, and chemical etching, we have made an 8- to 10-m PdCr thin-film strain gage that can measure dynamic and static strain to at least 1100 C. For static strain measurements, a 5-m-thick Pt element serves as a temperature compensator to further minimize the temperature effect of the gage. These thin-film gages provide the advantage of minimally intrusive surface strain measurements and give highly repeatable readings with low drift at temperatures from ambient to 1100 C. This is a 300 C advance in operating temperature over the PdCr wire gage and a 500 C advance over commercially available gages made of other materials.

Source record↗

A study of the effect of apparent strain on thermal stress measurement for two types of elevated temperature strain gages

A weldable type strain gage was used to measure low level thermal stress in an elevated temperature environment. Foil strain gages used in a comparative manner reveal that the apparent strain of weldable strain gages is not sufficiently known to acquire accurate low level thermal stress data. Apparent strain data acquired from coupon tests reveals a large scatter in apparent strain characteristics among the weldable strain gages. It is concluded that apparent strain data for individual weldable strain gages must be required prior to installation if valid thermal stress data is to be obtained through the temperature range of room temperature to 755 K (900 F).

Jenkins, J. M.↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 800 C

A temperature compensated static strain gage, which is fabricated from palladium-13w/o chromium (Pd13Cr) alloy and a platinum (Pt) compensator, is being developed and was tested over a temperature range to 800 C at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 800 C than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4w/o zirconia overcoating. Test results to 800 C indicate apparent strain variations of less than 300 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. Apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

Use of photostress and strain gages to analyze behavior of weldments and use of photostress and strain gages to analyze behavior of an aft skirt test specimen

Previous work using Photostress on TIG welded, heat treated specimens of 2219-T87 parent material and 2319 weld material indicated that behavior of the joint can be highly irregular and non-uniform. Welded joints 1.40 inches thick exhibited a totally non-uniform behavior through the weld thickness with the 'wide' side of the weld being much more ductile than the 'narrow' side. It is believed that this difference in behavior through the weld is, in part, caused by procedures used when laying the weld bead. Joints similar to weldments in references 1 and 2 are an integral part of the aft skirt of the SRB of the shuttle. Since the ultimate safety factor for the lower portion of the weld is below the minimum required safety factor, a photostress analysis of this lower portion will be conducted in the vicinity of the weld. A test program using photostress will be conducted in accordance with the project planning document entitled 'Photostress Evaluation Requirements for AFT Skirt Test Article No. 4'.

Gambrell, S. C.↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 1500 F

A temperature compensated static strain gauge, which is fabricated from Pd13Cr alloy and a Pt compensator, is being developed and has been tested over a temperature range to 1500 F at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 500 F than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4 wt pct zirconia overcoating. Test Results to 1500 F indicate apparent strain variations of less than 250 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. The apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

Strain Gages in use at NASA Langley: A Technical Review

Surface mounted strain gages and strain gage application techniques are as varied as they are versatile. There is an abundance of technical literature, available throughout the strain gage community, offering techniques for installing strain gages and methods of obtaining useful information from them. This paper, while providing more of the same, will focus its discussions on recent Langley developments for using strain gages reliably and accurately in very harsh environments. With Langley's extensive use of wind tunnel balances, its ongoing effort in materials development, and its currently focused activities in structural testing, the use of strain gages in unusual and demanding environments has led to several innovative improvements in the "how to gage it" department. Several of these innovations will be addressed that hopefully will provide some practical information for the strain gage user who is finding the test environment and (or) the materials to be tested too demanding for previously utilized strain gage application technology. Specifically, this paper will include discussions in the following three areas: (1) technical considerations when gaging cryogenic wind tunnel balances, including areas for improving accuracy and reliability; (2) addressing technical difficulties associated with gaging composite test articles and certain alloys for testing at temperatures approaching -450F, or elevated temperatures up to 350F, or both temperatures inclusive during the same test scenario; (3) gaging innovations for testing metal/matrix and carbon/carbon composites at temperatures above 700F.

Moore, Thomas C., Sr.↗

Strain gage balances and buffet gages

One-piece strain gage force balances were developed for use in the National Transonic Facility (NTF). This was accomplished by studying the effects of the cryogenic environment on materials, strain gages, cements, solders, and moisture proofing agents, and selecting those that minimized strain gage output changes due to temperature. In addition, because of the higher loads that may be imposed by the NTF, these balances are designed to carry a larger load for a given diameter than conventional balances. Full cryogenic calibrations were accomplished, and wind tunnel results that were obtained from the Langley 0-3-Meter Transonic Cryogenic Tunnel were used to verify laboratory test results.

Ferris, A. T.↗

Design of a strain-gage probe

Strain-gage spacer probe uses the deflection of a leaf spring to measure strain in a long, slender beam nondestructively. The selected gage is of the smallest practical size, as thin as possible and yet of a standard type.

Kolba, V. M.↗

High temperature static strain gage program

Development of electrical resistance strain gages for static strain measurements of nickel or cobalt superalloy parts inside a gas turbine engine on a test stand was inititated. Measurements of this type are of great importance because without reliable knowledge of the stresses and strains which exist in specific components, it will be difficult to fully appreciate where improvements in design and materials can be implemented. The first part of this effort consists of a strain gage alloy development program which will be followed by an investigation of complete strain gage systems. Efforts to date are summarized.

Hulse, C.↗