Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “static line rating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

Variable Transmission Line Ratings

This paper outlines the concept of variable-transmission facility ratings. This topic is of heightened importance following the recent Federal Energy Regulatory Commission (FERC) Order No. 881 which requires the implementation of ambient adjusted ratings (AARs) for FERC jurisdictional portions of the transmission system. Additionally, FERC issued an Advanced Notice of Proposed Rulemaking (ANOPR) implying a future order on Dynamic Line Rating (DLR) requirements. The various types of facility-rating methodologies will be discussed with a focus on how they can benefit the stability, capacity, and reliability of the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Transmission Technologies – GETs and HPCs Session 1: ATT Foundations and Dynamic Line Ratings (DLRs)

The INL TADA GETs Cohort Session 1, held on November 4, 2025, convened experts to address the integration of advanced transmission technologies, including Grid-Enhancing Technologies (GETs) and High Performance Conductors (HPCs), with a focus on digital assurance challenges. The session highlighted the growing importance of cybersecurity, supply chain transparency, reliability, and business risk management in deploying GETs, especially Dynamic Line Ratings (DLRs). Participants examined how expanded attack surfaces, limited vendor pools, and new regulatory requirements—such as FERC Orders 881, 2023, and 1920—are influencing utilities and technology providers. The workshop underscored the need for cyber-informed engineering, secure-by-design principles, and practical risk management strategies, while fostering collaboration and knowledge sharing among industry peers. Technical discussions covered the evolution from static to dynamic line ratings, complexities of cloud-based architectures, and NERC CIP compliance challenges. The session concluded with a collaborative risk exercise and a preview of future workshops on advanced power flow control and transmission topology optimization, reinforcing the cohort’s commitment to advancing digital assurance in the energy sector.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Impact of nitrogen molecular breakup on divertor conditions in JET L-mode plasmas using SOLPS-ITER

SOLPS-ITER simulations of nitrogen-seeded, low-confinement mode plasmas in the Joint European Torus (JET) predict that the electron temperature in the low-field side (LFS) divertor leg is reduced locally by up to an order of magnitude when nitrogen is assumed to recycle as molecules (N 2 ) instead of atoms using a fixed nitrogen injection rate. The LFS divertor temperature reduction under the assumption of molecular recycling occurs due to a three-step mechanism: (1) the plasma penetration of nitrogen atoms is increased due to the strong triple bond of the N 2 molecule and the kinetic energy release in the dissociation event, both mechanisms contributing equally, (2) the abundance of (particularly multiply-charged) nitrogen ions in the divertor is increased and (3) the electron temperature is reduced due to the increase in radiation (by up to a factor of 4) from nitrogen ions. Setting the volume-integrated nitrogen radiated power to a constant value (0.6 MW) instead of the nitrogen injection rate, SOLPS-ITER predicts under the molecular nitrogen recycling assumption that the peak line-integrated N II, N III and N IV intensities in the LFS divertor are approximately within 15%, 35% and 5%, respectively, of the reference atomic nitrogen recycling case. The predicted peak N II, N III and N IV intensities under either assumption are within 30%, 65% and 5%, respectively, of measurements using the vertically viewing mirror-link divertor spectrometer (Meigs et al., 2010) in nitrogen-seeded JET L-mode plasmas (Lomanowski et al., 2019). ERO2.0 simulations using a constant nitrogen seeding rate on static background plasma solutions from EDGE2D-EIRENE (previously presented in Mäenpää et al., (2022), revised here to include fast reflections) predict that N II to N IV line emission is increased by 20% to 30% when nitrogen is assumed to recycle as molecules, demonstrating the importance of considering the effect of molecular dissociation reactions on the divertor plasma in a self-consistent manner.

Divertor↗

Dynamic and static corrosion of chromium-alumina refractory in simulated nuclear waste glass

Monofrax® K-3, a chromium–alumina refractory, is widely used in nuclear waste glass melters due to its high durability. However, aggressive vitrification conditions still lead to corrosion that limits melter lifespan. Here, this study investigates two key corrosion modes, subsurface and melt-line corrosion, under static and dynamic conditions, using a custom setup enabling precise control of melt velocity and temperature. Experimental results, interpreted using diffusion-limited dissolution models, show that (i) subsurface corrosion increases by approximately 10% per mm/s increase in melt velocity, while melt-line corrosion remains virtually unaffected, (ii) corrosion rate dependence on temperature is inversely proportional to melt viscosity, and (iii) glass composition affects both corrosion modes similarly, based on Cr 2 O 3 , Al 2 O 3 , and alkali contents. The experimental data also allowed the determination of diffusion coefficients of major dissolving species, which were found to be consistent between the melt-line and subsurface corrosion models, indicating their suitability for future CFD studies.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of static Wilson line correlators from lattice QCD at finite temperature with T -matrix approach

The thermodynamic T-matrix approach is used to study Wilson line correlators (WLCs) for a static quark-antiquark pair in the quark-gluon plasma (QGP). Selfconsistent results that incorporate constraints from the QGP equation of state can approximately reproduce WLCs computed in 2+1-flavor lattice-QCD (lQCD), provided the input potential exhibits less screening than in previous studies. Utilizing the updated potential to calculate pertinent heavylight T-matrices we evaluate thermal relaxation rates of heavy quarks in the QGP. We find a more pronounced temperature dependence for low-momentum quarks than in our previous results (with larger screening), which turns into a weaker temperature dependence of the (temperature-scaled) spatial diffusion coefficient, in fair agreement with the most recent lQCD data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evolution of the electrothermal instability from thick rod z pinches subject to dynamically and statically applied axial magnetic field

LDRD Project 229427 aimed to determine how electrothermal instability (ETI) driven heating on a z-pinch rod pulsed with intense current evolves under mixed magnetic field (azimuthal + axial) conditions, which is pertinent to pulsed-power-driven magnetically-insulated transmission lines and physics targets. Experiments focused on diagnosing ETI-driven heating from deliberately-machined and well-characterized micron-scale surface defects (referred to as engineered defects or ED). Prior to the start of this project, understanding of how unmagnetized (B z =0) ED evolve had been obtained—simulations largely reproduce the experimentally observed high temperature spots which develop at the poles of bare/uncoated ED. Project 229427 extended the Mykonos Facility ED experimental platform to include axial field. In the first class of experiments, axial field was provided “dynamically” via a helical return can (HRC). In this case, B z and B θ rise at the same rate. Generally, the HRC generated magnetic field at a fixed polarization angle Φ B =arctan(B z /B θ )=15° on the rod's surface. In the second class of experiments, axial field was provided “statically” via a slow-rising (millisecond) external Helmholtz coil pair. In this case, B z was effectively constant/static throughout the 100 ns rise of the Mykonos current. For either case, a primary goal was to determine whether ETI provides a helical seed perturbation for the subsequent growth of the helical magneto Rayleigh-Taylor modes observed in MagLIF (static B z ) and dynamic screw pinch (DSP, dynamic B z ) experiments. When dynamic field was applied using an HRC, emissions from individual ED aligned toward Φ B , while emissions from ED within pairs elongated and preferentially merged along Φ B . These data strongly support that for a randomized defect distribution, heating from nearby current-density perturbations will favorably merge about Φ B to generate an extended seed perturbation that aligns toward the surface-field polarization, and this may impact the orientation of subsequent MRT growth on imploding liners. The results from the static field experiments were largely inconclusive, as any ETI heating rotation, if present, was obscured/overwhelmed by local/random heating from ED rim imperfections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanocrystal-to-Ligand Interfacial Thermal Transport: Plasmonic Indium Tin Oxide to Perylene Diimide Adsorbates

The generation and dissipation of heat in nanocrystals upon optical excitation is a process which may either limit or enhance their performance in certain applications. Using transient absorption spectroscopy, we tracked the flow of heat from plasmonic tin-doped indium oxide (ITO) nanocrystals to surface adsorbed perylenediimide (PDI) molecules upon excitation of the ITO near-infrared plasmon resonance. Here, we rationalize the derivative line shapes observed in the transient absorption bleach features are the result of thermal transfer from the ITO core to surface ligands based on temperature-dependent static absorption studies of the PDI molecules adsorbed on plasmonic ITO. Through a series of pump power dependent measurements, we demonstrate that the PDI heating time is largely fluence independent at the powers measured, while the overall recovery time increases. Elucidating thermal transfer rates at the nanocrystal and organic ligand interface is key for applications such as plasmon mediated photocatalysis, where heating may obfuscate hot carrier transfer processes.

heat dissipation↗

CFD modeling and simulation for corrosive wear of refractory in molten slag

The development of high-wear resistant refractories having minimal production costs is facilitated by characterizing the wear mechanisms associated with their corrosive wear. Static cup testing is a commonly used method for comparing the corrosion resistance performance of two or more refractory materials. Although the static cup test conditions are not as severe as dynamic tests, this study shows that the thermal gradient present within the system during heating and cooling stages serves to generate movement of the slag leading to mechanical wear. The thermal gradient within the refractory, and between the slag and the refractory, occurs during the ramp stage of the test and lasts until the soaking stage is reached bringing the system to a thermal equilibrium. Using computational fluid dynamics (CFD) capabilities embedded within ANSYS software, this study modelled and quantified the convection currents within the slag and associated shear stresses generated on the refractory walls due to the thermal gradient. A traditional ladle furnace was employed as a case study to verify the results of the studied CFD model. The corrosion rate of the refractory lining was found to depend on the mass transfer coefficient of the refractory dissolution into the slag, and a velocity term which governs the extent of corrosion at any given location. This velocity term is a function of slag viscosity, as well as the concentration gradient and/or temperature gradient at the triple points. In this study, wall shear stress was used as a reliable proxy for identifying high-velocity regions prone to excessive corrosive wear. Elevated wall shear stress near the slag/air and slag/molten steel interfaces align with observed corrosion grooves, which reflects the intensified corrosive wear at these locations.

Ramteke, Rajat Rajat Durgesh Ramteke [University o↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗