Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Application of the coincidence counting technique to DD neutron spectrometry data at the NIF, OMEGA, and Z

A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protons at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Strategy To Analyze Fourier Transform Ion Cyclotron Resonance Mass Spectrometry Data of Biomass Pyrolysis Oil for Oligomeric Structure Assignment

Among the most prominent challenges for the analysis of biomass pyrolysis products is the characterization of the abundant oligomer fraction of bio-oil. This fraction is principally made up of pyrolytic lignins and dehydrated, highly modified sugar oligomers, called humins, in liquid phase. An emerging technique for analysis of this oligomer fraction is high-resolution Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS), which allows for accurate determination of C x H y O z formulae for detected oligomers. Additionally, using simple dehydration and fragmentation reaction schemes, similar formulae can be developed from cellulose-, hemicellulose- and lignin-derived oligomers, which are primary depolymerization products. In this paper, FT-ICR MS analysis is coupled with combinatoric dehydration and fragmentation modeling in order to match experimentally detected bio-oil oligomers with hypothetical pathways for their formation during pyrolysis. In this way, we present a novel strategy by which oligomeric structures can be proposed for bio-oils. Using this approach, it becomes possible to advance the understanding of both the molecular structures comprising the bio-oil oligomer fraction and the pathways by which these structures form during biomass pyrolysis reactions.

09 BIOMASS FUELS↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

Enabling Re-executable Workflows with Near-realtime Visualization, Provenance Capture and Advanced Querying for Mass Spectrometry Data

Mass spectrometry imaging (MSI) enables simultaneous spatially-resolved analysis of numerous ionizable molecules on a sample surface. The current analysis pipeline involves analyzing the data coming off the instrument using a tool called MSI Quickview and saving the results onto a storage drive before moving on to the next experiment. While this works well for single datasets, there is a demand for more scalable, flexible workflows that are re-executable across datasets, support extensive querying and ease collaboration. Here, we present a workflow that moves data analysis from a mere desktop application for single experiments to a more general capability

Re-executable workflow↗

A universal language for finding mass spectrometry data patterns

Despite being information rich, the vast majority of untargeted mass spectrometry data are underutilized; most analytes are not used for downstream interpretation or reanalysis after publication. The inability to dive into these rich raw mass spectrometry datasets is due to the limited flexibility and scalability of existing software tools. Here, in this study, we introduce a new language, the Mass Spectrometry Query Language (MassQL), and an accompanying software ecosystem that addresses these issues by enabling the community to directly query mass spectrometry data with an expressive set of user-defined mass spectrometry patterns. Illustrated by real-world examples, MassQL provides a data-driven definition of chemical diversity by enabling the reanalysis of all public untargeted metabolomics data, empowering scientists across many disciplines to make new discoveries. MassQL has been widely implemented in multiple open-source and commercial mass spectrometry analysis tools, which enhances the ability, interoperability and reproducibility of mining of mass spectrometry data for the research community.

Damiani, Tito [Czech Academy of Sciences (CAS), Pr↗

PECAN: library-free peptide detection for data-independent acquisition tandem mass spectrometry data

Data-independent acquisition (DIA) is an emerging mass spectrometry (MS)-based technique for unbiased and reproducible measurement of protein mixtures. DIA tandem mass spectrometry spectra are often highly multiplexed, containing product ions from multiple cofragmenting precursors. Detecting peptides directly from DIA data is therefore challenging; most DIA data analyses require spectral libraries. Here we present PECECAN (http://pecan.maccosslab.org), a library-free, peptide-centric tool that robustly and accurately detects peptides directly from DIA data. PECECAN reports evidence of detection based on product ion scoring, which enables detection of low-abundance analytes with poor precursor ion signal. We demonstrate the chromatographic peak picking accuracy and peptide detection capability of PECECAN, and we further validate its detection with data-dependent acquisition and targeted analyses. Lastly, we used PECECAN to build a plasma proteome library from DIA data and to query known sequence variants.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

mzapy : An Open-Source Python Library Enabling Efficient Extraction and Processing of Ion Mobility Spectrometry-Mass Spectrometry Data in the MZA File Format

We have recently reported MZA, a new and simple mass spectrometry data structure based on the broadly supported HDF5 format and created to facilitate software development. While this format is inherently supportive of application development, the availability of a core library with standard mass spectrometry utilities greatly facilitates fast software development. Here, we present a Python library, mzapy, for efficient extraction and processing of mass spectrometry data in the MZA format. In addition to raw data extraction, mzapy contains supporting utilities enabling tasks including calibration, signal processing, peak finding, and generating plots. Being implemented in pure Python with minimal and largely standardized dependencies makes mzapy uniquely suited to application development in the multi-omics domain. The free and open source mzapy is built with extensibility in mind, and future development will support cloud computing and artificial intelligence/machine learning applications. The software source code is freely available at https://github.com/PNNL-m-q/mzapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recommendations for mass spectrometry data quality metrics for open access data(corollary to the Amsterdam principles)

Policies supporting the rapid and open sharing of proteomic data are being implemented by the leading journals in the field. The proteomics community is taking steps to ensure that data are made publicly accessible and are of high quality, a challenging task that requires the development and deployment of methods for measuring and documenting data quality metrics. On September 18, 2010, the U.S. National Cancer Institute (NCI) convened the 'International Workshop on Proteomic Data Quality Metrics' in Sydney, Australia, to identify and address issues facing the development and use of such methods for open access proteomics data. The stakeholders at the workshop enumerated the key principles underlying a framework for data quality assessment in mass spectrometry data that will meet the needs of the search community, journals, funding agencies, and data repositories. Attendees discussed and agreed upon two primary needs for the wide use of quality metrics: (i)an evolving list of comprehensive quality metrics and (ii)standards accompanied by software analytics. Attendees stressed the importance of increased education and training programs to promote reliable protocols in proteomics. This workshop report explores the historic precedents, key discussions, and necessary next steps to enhance the quality of open access data. By agreement, this article is published simultaneously in Proteomics, Proteomics Clinical Applications, Journal of Proteome Research, and Molecular and Cellular Proteomics, as a public service to the research community.The peer review process was a coordinated effort conducted by a panel of referees selected by the journals.

59 BASIC BIOLOGICAL SCIENCES↗

DEIMoS: An Open-Source Tool for Processing High-Dimensional Mass Spectrometry Data

We present DEIMoS: Data Extraction for Integrated Multidimensional Spectrometry, a Python application programming interface and command-line tool for high-dimensional mass spectrometry data analysis workflows, offering ease of development and access to efficient algorithmic implementations. Functionality includes feature detection, feature alignment, collision cross section calibration, isotope detection, and MS/MS spectral deconvolution, with the output comprising detected features aligned across study samples and characterized by mass, CCS, tandem mass spectra, and isotopic signature. Notably, DEIMoS operates on N-dimensional data, largely agnostic to acquisition instrumentation: algorithm implementations utilize all dimensions simultaneously to (i) offer greater separation between features, improving detection sensitivity, (ii) increase alignment/feature matching confidence among datasets, and (iii) mitigate convolution artifacts in tandem mass spectra. We demonstrate DEIMoS with LC-IMS-MS/MS data, demonstrating the advantages of a multidimensional approach in each data processing step.

Colby, Sean M↗

GNPS Dashboard: collaborative exploration of mass spectrometry data in the web browser

Access to web-based platforms has enabled scientists to perform research remotely. A critical aspect of mass spectrometry data analysis is the inspection, analysis, and visualization of the raw data to validate data quality and confirm statistical observations. We developed the GNPS Dashboard, a web-based data visualization tool, to facilitate synchronous collaborative inspection, visualization, and analysis of private and public mass spectrometry data remotely.

59 BASIC BIOLOGICAL SCIENCES↗

Peptide-Centric Proteome Analysis: An Alternative Strategy for the Analysis of Tandem Mass Spectrometry Data

In mass spectrometry-based bottom-up proteomics, data-independent acquisition (DIA) is an emerging technique due to its comprehensive and unbiased sampling of precursor ions. However, current DIA methods use wide precursor isolation windows, resulting in co- fragmentation and complex mixture spectra. Thus, conventional database searching tools that identify peptides by interpreting individual MS/MS spectra are inherently limited in analyzing DIA data. Here we discuss an alternative approach, peptide-centric analysis, which tests directly for the presence and absence of query peptides. We discuss how peptide-centric analysis resolves some limitations of traditional spectrum-centric analysis, and we outline the benefits of peptide-centric analysis in general.

analyte-centric analysis↗

DEIMoS GUI: An Open-Source User Interface for a High-Dimensional Mass Spectrometry Data Processing Tool

In this paper, we report the creation of a graphical user interface (GUI) for the Data Extraction for Integrated Multidimensional Spectrometry (DEIMoS) tool. DEIMoS is a Python package to process data from high-dimensional mass spectrometry measurements. It is divided into several modules, each representing a data processing step, such as peak detection, alignment, and tandem mass spectra extraction and deconvolution. The inputs for and outputs from DEIMoS can include millions of N-dimensional data points, which can be challenging to visualize in a way that is interactive, informative, and responsive. Here, we used the HoloViz Python data stack, including DataShader and Param, to create an interactive visualization of mass spectrometry data. We believe the GUI will increase the accessibility of DEIMoS, and the visualization methods could be useful for other open-source mass spectrometry tools.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

mzPeak: Designing a Scalable, Interoperable, and Future-Ready Mass Spectrometry Data Format

Advances in mass spectrometry (MS) instrumentation, such as higher resolution, faster scan speeds, and improved sensitivity, have significantly increased the volume and complexity of data. The growing adoption of imaging and ion mobility further amplifies these challenges across MS-based omics fields, including proteomics, metabolomics, and lipidomics. While these technologies unlock new possibilities, they also present significant challenges in data management, storage, and accessibility. Existing open formats, such as the XML-based community standards mzML and imzML, struggle to meet the demands of modern MS workflows due to their large file sizes, slow data access, and limited metadata support. Vendor-specific formats, while optimized for proprietary instruments, lack interoperability, comprehensive metadata support and long-term archival reliability. This white paper lays the groundwork for mzPeak, a next-generation community data format designed to address these challenges and support high-throughput, multi-dimensional MS workflows. By adopting a hybrid model that combines efficient binary storage for numerical data and both human and machine-readable metadata storage, mzPeak will reduce file sizes, accelerate data access, and offer a scalable, adaptable solution for evolving MS technologies. For researchers, mzPeak will enable enhanced interoperability across platforms, seamless support for complex workflows including ion mobility and MS imaging, and faster data access compared to existing community formats such as mzML. Its design will ensure data is managed in compliance with regulatory standards, essential for applications such as precision medicine and chemical safety, where long-term data integrity and accessibility are critical. For vendors, mzPeak provides a streamlined, open alternative to proprietary formats, reducing the burden of regulatory compliance while aligning with the industry's push for transparency and standardization. By offering a high-performance, interoperable solution, mzPeak positions vendors to meet customer demands for sustainable data management tools which will be able to handle emerging and future data types and workflows. mzPeak aspires to become the cornerstone of MS data management, empowering researchers, vendors, and developers to innovate and collaborate more effectively.

data formats↗

Attributes from NMIS Time Coincidence, Fast-Neutron Imaging, Fission Mapping, And Gamma-Ray Spectrometry Data

This work tests a systematic procedure for analyzing data acquired by the Nuclear Materials Identification System (NMIS) at Oak Ridge National Laboratory with fast-neutron imaging and high-purity germanium (HPGe) gamma spectrometry capabilities. NMIS has been under development by the US Department of Energy Office of Nuclear Verification since the mid-1990s, and prior to that by the National Nuclear Security Administration Y-12 National Security Complex, with NMIS having been used at Y-12 for template matching to confirm inventory and receipts. In this present work, a complete set of NMIS time coincidence, fast-neutron imaging, fission mapping, and HPGe gamma-ray spectrometry data was obtained from Monte Carlo simulations for a configuration of fissile and nonfissile materials. The data were then presented for analysis to someone who had no prior knowledge of the unknown object to accurately determine the description of the object by applying the previously mentioned procedure to the simulated data. The best approximation indicated that the unknown object was composed of concentric cylinders: a void inside highly enriched uranium (HEU) (84.7 {+-} 1.9 wt % 235 U), surrounded by depleted uranium, surrounded by polyethylene. The final estimation of the unknown object had the correct materials and geometry, with error in the radius estimates of material regions varying from 1.58% at best and 4.25% at worst; error in the height estimates varied from 2% to 12%. The error in the HEU enrichment estimate was 5.9 wt % (within 2.5Σ of the true value). The accuracies of the determinations could be adequate for arms control applications. Future work will apply this iterative reconstructive procedure to other unknown objects to further test and refine it.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Auto-deconvolution and molecular networking of gas chromatography–mass spectrometry data

We engineered a machine learning approach, MSHub, to enable auto-deconvolution of gas chromatography–mass spectrometry (GC–MS) data. We then designed workflows to enable the community to store, process, share, annotate, compare and perform molecular networking of GC–MS data within the Global Natural Product Social (GNPS) Molecular Networking analysis platform. MSHub/GNPS performs auto-deconvolution of compound fragmentation patterns via unsupervised non-negative matrix factorization and quantifies the reproducibility of fragmentation patterns across samples.

47 OTHER INSTRUMENTATION↗

Automated Interpretation and Extraction of Topographic Information from Time of Flight Secondary Ion Mass Spectrometry Data

Time of flight secondary ion mass spectrometry (ToF SIMS) is one of the most powerful characterization tools allowing imaging of the chemical properties of various systems and materials. It allows precise studies of the chemical composition with sub-100-nm lateral and nanometer depth spatial resolution. However, comprehensive interpretation of ToF SIMS results is challengeable, because of the data volume and its multidimensionality. Furthermore, investigation of the samples with pronounced topographical features are complicated by the spectral shift. In this work we developed approach for the comprehensive ToF SIMS data interpretation based on the data analytics and automated extraction of the sample topography based on time of flight shift. We further applied this approach to investigate correlation between biological function and chemical composition in Arabidopsis roots.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FREDA: A Web Application for the Processing, Analysis, and Visualization of Fourier‐Transform Mass Spectrometry Data

The high-resolution measurement capability of Fourier-transform mass spectrometry (FT-MS) has made it a necessity for exploring the molecular composition of complex organic mixtures, like soil, plant, aquatic, and petroleum samples. This demand has driven a need for informatics tools to explore and analyze FT-MS data in a robust and reproducible manner. FREDA is an interactive web application developed to enable spectrometrists to format, process, and explore their FT-MS data without the need for statistical programming expertise. FREDA was built to explore outputs from a molecular identification tool, like CoreMS, and provide a suite of methods to filter data, compute chemical properties of peaks, statistically compare samples and groups of samples, conduct exploratory data analysis, and download the results with a report detailing all steps conducted. To demonstrate the utility of FREDA, an example analysis was conducted using FT-MS data from a soil microbiology study of samples collected in two different soil depths at the Sphagnum bog forest north of Grand Rapids, Minnesota. Differences between the two depths are observed using Kendrick, Gibbs free energy, and van Krevelen plots. G-tests are used to quantify a significant difference between the groups. All analyses and plotting are conducted using only the FREDA application. FREDA is an open-source and readily available web application that allows users to explore and make statistically valid conclusions about their FT-MS data. The application is available online (https://map.emsl.pnnl.gov/app/freda) with a tutorial web series (https://youtu.be/k5HLE2kNSBY?si=yB6sGoyvzxrFf5MP) and freely accessible code on Github (https://github.com/EMSL-Computing/FREDA).

47 OTHER INSTRUMENTATION↗