Engineering PapersSearch

SEARCH · Engineering Papers

Results for “spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bulk and integrated acousto-optic spectrometers for molecular astronomy with heterodyne spectrometers

A survey of acousto-optic spectrometers for molecular astronomy is presented, noting a technique of combining the acoustic bending of a collimated coherent light beam with a Bragg cell followed by an array of sensitive photodetectors. This acousto-optic spectrometer has a large bandwidth, a large number of channels, high resolution, and is energy efficient. Receiver development has concentrated on high-frequency heterodyne systems for the study of the chemical composition of the interstellar medium. RF spectrometers employing acousto-optic diffraction cells are described. Acousto-optic techniques have been suggested for applications to electronic warfare, electronic countermeasures and electronic support systems. Plans to use integrated optics for the further miniaturization of acousto-optic spectrometers are described. Bulk acousto-optic spectrometers with 300 MHz and 1 GHz bandwidths are being developed for use in the back-end of high-frequency heterodyne receivers for astronomical research.

Chin, G.

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) spectrometer design and performance

The development of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has been completed at JPL. This paper outlines the functional requirements of the spectrometer optics subsystem, and describes the spectrometer optical design. The optical subsystem performance is shown in terms of spectral modulation transfer functions, radial energy distributions, and system transmission at selected wavelengths for the four spectrometers. An outline of the spectrometer alignment is included.

Macenka, Steven A.

Tropospheric Emission Spectrometer and Airborne Emission Spectrometer

The Tropospheric Emission Spectrometer (TES) is an instrument being developed for the NASA Earth Observing System Chemistry Platform. TES will measure the distribution of ozone and its precursors in the lower atmosphere. The Airborne Emission Spectrometer (AES) is an aircraft precursor to TES. Applicable descriptions are given of instrument design, technology challenges, implementation and operations for both.

TES AES Ozone Spectrometer Earth Observation

Automated extraction of absorption features from Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and Geophysical and Environmental Research Imaging Spectrometer (GERIS) data

Automated techniques were developed for the extraction and characterization of absorption features from reflectance spectra. The absorption feature extraction algorithms were successfully tested on laboratory, field, and aircraft imaging spectrometer data. A suite of laboratory spectra of the most common minerals was analyzed and absorption band characteristics tabulated. A prototype expert system was designed, implemented, and successfully tested to allow identification of minerals based on the extracted absorption band characteristics. AVIRIS spectra for a site in the northern Grapevine Mountains, Nevada, have been characterized and the minerals sericite (fine grained muscovite) and dolomite were identified. The minerals kaolinite, alunite, and buddingtonite were identified and mapped for a site at Cuprite, Nevada, using the feature extraction algorithms on the new Geophysical and Environmental Research 64 channel imaging spectrometer (GERIS) data. The feature extraction routines (written in FORTRAN and C) were interfaced to the expert system (written in PROLOG) to allow both efficient processing of numerical data and logical spectrum analysis.

Kruse, Fred A.

Long-term changes in the total ozone mapping spectrometer relative to world primary standard Dobson spectrometer 83

The stability of the calibration of the Nimbus 7 solar backscatter UV (SBUV) and total ozone mapping spectrometer (TOMS) instruments by comparing their ozone measurements with those made by a single, very stable Dobson instrument: the world primary standard Dobson spectrometer number 83. Measurements of ozone made with instrument 83 at Mauna Loa observatory in eight summers between 1979 and 1989 were compared with coincident TOMS ozone measurements. The comparison shows that relative to instrument 83, ozone measured by TOMS (and SBUV) was stable between 1979 and approximately 1983, had decreased by 3 percent by 1986, and had decreased by almost 7 percent by 1989. A similar time dependence is seen when data from an ensemble of 39 Dobson stations throughout the world is compared with TOMS over the period 1979-1987. The most likely reason for the relative drift is that the diffuser plate used by both SBUV and TOMS to measure solar flux has suffered an uncorrected wavelength-dependent degradation, with most of the degradation occurring after 1983. The recently released version 6 TOMS data, corrected using the internal 'pair justification' technique, show almost no drift relative to Dobson instrument 83. Accurate measurements of long-term global ozone change will require a coherent system incorporating both ground-based and satellite-based ozone measurements.

Mcpeters, Richard D.

Acousto-optic tunable filter field spectrometer for validation of airborne and spaceborne imaging spectrometers

A new concept for a field portable spectrometer designed to meet the needs of the remote sensing community is presented. This instrument uses acoustooptic tunable filters (AOTFs) as wavelength sorters, allowing the design of a rugged, compact, light-weight tool that provides broad spectral coverage, great versatility, and ease of utilization. The spectrometer provides continuous spectral coverage from 0.4 to 2.5 microns with two channels defined by detector technology, while a visible channel covering the 0.4 to 1.0 micron spectral range uses silicon PV photodiodes. The short-wavelength IR channel covers the 0.9 to 2.5 micron special range with thermoelectrically cooled lead sulfide PC detectors.

Rider, David M.

Volume 1. Preliminary design study: AXAF x ray calibration spectrometers. Volume 2. Revised preliminary design study: AXAF x ray calibration spectrometers

The objective of this work was to provide a preliminary design concept for a Flux Monitor Spectrometer (FMS) for use at the X Ray Astrophysics Facility (XRAF) during High Resolution Mirror Assembly (HRMA) testing that met the requirements of SAO-AXAF-88-025 dated July 31, 1991. The calibration test team determined that the spectral resolution of the FMS had to be greater than or equal to twice that of all the AXAF spectrometers throughout the 0.1 to 10 KeV range of x-ray energies. Since this effectively doubled the resolution required by SAO-AXAF-88-025, a change order was approved by the Marshall Space Flight Center and given to Radiation Sciences to revise their study.

Source record

The Plasma Proton Environment within Saturn’s F-G Ring Gap as Observed by the Cassini Plasma Spectrometer Ion Mass Spectrometer during Saturn Orbit Insertion

We report on the detection of protons and the potential detection of H 2 + between Saturn's F and G rings based on Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) time-of-flight (TOF) composition measurements acquired during Saturn Orbit Insertion (SOI) outbound pass. The range in dipole L shell is 2.3 < L < 2.8. Initial results based on TOF data were presented in E. C. Sittler et al., 2017. Here we present the latest results of our analysis. During the SOI outbound pass between the F and G rings the CAPS IMS was in a mode of reduced post-acceleration voltage at -6 kV instead of the usual -14.6 kV. This reduced voltage still allows the analysis of protons since 6 keV protons are minimally scattered by the instrument’s ultrathin carbon foils when compared to heavier ions O + and O 2 + , scattering. Background noise from penetrating radiation and ghost peaks produced by foil-scattered O + ions within the instrument were considered in our analysis. The analysis allowed determination of the proton density, temperature and flow velocity, accounting for spacecraft potential by assuming a convected Maxwellian for the proton velocity distribution function. We find average proton density n P = 3.2 ± 1.1 #/cm 3 , proton temperature T P = 1.74 ± 0.12 eV, proton rotational flow speed V P = 24 ± 1.5 km/s and spacecraft potential  SC = -0.8 ±1.5 V. These results are compared with previous theoretical estimates of H + and H 2 + ions within Saturn’s inner magnetosphere.

E C Sittler

Composition measurements of the topside ionosphere using a magnetic mass spectrometer, ion mass spectrometer on ISIS-2 spacecraft

The ion mass spectrometer (IMS) on the ISIS-II satellite is described; it measures the composition and distribution of positive ions in the earth's ionosphere in the mass range of 1 to 64 atomic mass units. Significant data were received which show a wide variation in ion composition at night near the equator and in the daytime poleward of the plasmapause. It was found that these data enable further study of the polar wind and that the experiment produced timely data during the August, 1972 magnetic storm to show the development of a unique ionosphere above the plasmapause during the period of the storm. The scientific objectives and results of the experiment, the technical description of the instrument, a bibliography with sample papers attached, and a summary of recommendations for further study are presented.

Hoffman, J. H.

Recovery of Atmospheric Water Vapor Total Column Abundance from Imaging Spectrometer Data Around 940 nm - Sensitivity Analysis and Application to Airborne Visible/Infrared Imaging Spectrometer (AVIRI

Twosimple techniques to retrieve path precipitable water fromthe Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) high spectral resolution radiance data (Continuum Interpolated Band Ratio, CIBR, and Narrow/Wide Ratio, N/W), using the 940 nm water absorption band, are compared.

water present surface reflectance atmospheric catt

APES: Acute Precipitating Electron Spectrometer - A High Time Resolution Monodirectional Magnetic Deflection Electron Spectrometer

We present a description of the Acute Precipitating Electron Spectrometer (APES) that was designed and built for the Ground-to-Rocket Electron Electrodynamics Correlative Experiment (GREECE) auroral sounding rocket mission. The purpose was to measure the precipitating electron spectrum with high time resolution, on the order of milliseconds. The trade-off made in order to achieve high time resolution was to limit the aperture to only one look direction. The energy selection was done by using a permanent magnet to separate the incoming electrons, such that the different energies would fall onto different regions of the microchannel plate and therefore be detected by different anodes. A rectangular microchannel plate (MCP) was used (15 mm x 100 mm), and there was a total of 50 discrete anodes under the MCP, each one 15 mm x 1.5 mm, with a 0.5 mm spacing between anodes. The target energy range of APES was 200 eV to 30 keV.

Michell, R. G.

Recovery of atmospheric water vapor total column abundance from imaging spectrometer data around 940 nm - Sensitivity analysis and application to Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data

Two simple techniques (Continuum Interpolated Band Ratio, CIBR, and Narrow/Wide ratio, N/W) to retrieve path precipitable water from AVIRIS high spectral resolution radiance data using the 940 nm water absorption band are compared. A sensitivity analysis was performed using the radiative transfer code LOWTRAN 7 to determine which one of these two approaches will provide a better estimate over land and water areas. The CIBR proved to be the technique less sensitive to perturbing effects, except for errors in visibility estimate. Both techniques were applied to AVIRIS radiance data acquired over Salton Sea, California. Resulting images confirmed that the use of a constant gray reflectance in the model led to a higher overestimation of the amount of water retrieved for N/W over vegetated areas. Validation was performed through comparison between an independent estimate of water vapor from concurrent Reagan sunphotometer measurements and AVIRIS estimates. Amounts retrieved using the N/W approach match more closely in situ measurements, even after adjusting model parameters for background reflectance, viewing geometry, and type of aerosol at the site.

Carrere, Veronique

Comprehensive Analyses of Data Collected from TEREK (Solar EUV Telescope) RES-C (Solar X-Ray Spectrometer) and SORS (Solar Radio Spectrometer) on board CORONAS-1 Using Magnetohydrodynamic Models

By using the observed magnetic field data obtained from the Wilcox Solar Observatory at Stanford University as the inputs to a two-dimensional plane-of-sky magnetohydrodynamic model, via numerical relaxation method, we have deduced the plasma and magnetic field parameters for the observed coronal hole by CORONAS-1. The method for this self-consistent MHD analysis will be discussed in detail. Numerical results for the magnetic field configuration, velocity distribution, density and temperature distributions will be presented. We have converted the computed density to polarization brightness in order to directly compare the MHD outputs with observations. Also included is a summary of achievements made during the grant period. This section is summarized into three categories: 1) Visit of Co-Investigators; 2) Presentations; and 3) Papers published, accepted and submitted for publication in journals.

Wu, S. T.

Pseudoslit Spectrometer

The pseudoslit spectrometer is a conceptual optoelectronic instrument that would offer some of the advantages, without the disadvantages, of prior linear-variable etalon (LVE) spectrometers and prior slit spectrometers. The pseudoslit spectrometer is so named because it would not include a slit, but the combined effects of its optical components would include a spatial filtering effect approximately equivalent to that of a slit. Like a prior LVE spectrometer, the pseudoslit spectrometer would include an LVE (essentially, a wedge-like narrowband- pass filter, the pass wavelength of which varies linearly with position in one dimension) in a focal plane covering an imaging planar array of photodetectors. However, the pseudoslit spectrometer would be more efficient because unlike a prior LVE spectrometer, the pseudoslit spectrometer would not have to be scanned across an entire field of view to obtain the spectrum of an object of interest that may occupy only a small portion of the field of view. Like a prior slit spectrometer, the pseudoslit spectrometer could acquire the entire spectrum of such a small object without need for scanning. However, the pseudoslit spectrometer would be optically and mechanically simpler: it would have fewer components and, hence, would pose less of a problem of alignment of components and would be less vulnerable to misalignment.

Reuter, Dennis C.