Engineering PapersSearch

SEARCH · Engineering Papers

Results for “spectroRadiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of Coincident Multiangle Imaging Spectroradiometer and Moderate Resolution Imaging Spectroradiometer Aerosol Optical Depths over Land and Ocean Scenes Containing Aerosol Robotic Network Sites

The Multiangle Imaging Spectroradiometer (MISR) and the Moderate Resolution Imaging Spectroradiometer (MODIS), launched on 18 December 1999 aboard the Terra spacecraft, are making global observations of top-of-atmosphere (TOA) radiances. Aerosol optical depths and particle properties are independently retrieved from these radiances using methodologies and algorithms that make use of the instruments corresponding designs. This paper compares instantaneous optical depths retrieved from simultaneous and collocated radiances measured by the two instruments at locations containing sites within the Aerosol Robotic Network (AERONET). A set of 318 MISR and MODIS images, obtained during the months of March, June, and September 2002 at 62 AERONET sites, were used in this study. The results show that over land, MODIS aerosol optical depths at 470 and 660 nm are larger than those retrieved from MISR by about 35% and 10% on average, respectively, when all land surface types are included in the regression. The differences decrease when coastal and desert areas are excluded. For optical depths retrieved over ocean, MISR is on average about 0.1 and 0.05 higher than MODIS in the 470 and 660 nm bands, respectively. Part of this difference is due to radiometric calibration and is reduced to about 0.01 and 0.03 when recently derived band-to-band adjustments in the MISR radiometry are incorporated. Comparisons with AERONET data show similar patterns.

Moderate Resolution Imaging Spectroradiometer (MOD

Multipurpose Spectroradiometer for Satellite Instrument Calibration and Zenith Sky Remote Sensing Measurements

In the early 1990s a series of surface-based direct sun and zenith sky measurements of total column ozone were made with SBUV/2 flight models and the SSBUV Space Shuttle instrument in Boulder, Colorado which were compared with NOAA Dobson Instrument direct sun observations and TOMS instrument overpass observations of column ozone. These early measurements led to the investigation of the accuracy of derived total column ozone amounts and aerosol optical depths from zenith sky observations. Following the development and availability of radiometrically stable IAD narrow band interference filter and nitrided silicon photodiodes a simple compact multifilter spectroradiometer was developed which can be used as a calibration transfer standard spectroradiometer (CTSS) or as a surface based instrument remote sensing instruments for measurements of total column ozone and aerosol optical depths. The total column ozone derived from zenith sky observations agrees with Dobson direct sun AD double wavelength pair measurements and with TOMS overpass ozone amounts within uncertainties of about 1%. When used as a calibration transfer standard spectroradiometer the multifilter spectroradiometer appears to be capable of establishing instrument radiometric calibration uncertainties of the order of 1% or less relative to national standards laboratory radiometric standards.

Heath, Donald F.

Design and initial performance evaluation of a portable short wave infrared spectroradiometer

The design, initial calibration, and performance evaluations of a portable short wave infrared (SWIR) spectroradiometer are described. The spectroradiometer covers the range from 1.1 to 2.5 microns with a spectral resolution that may be varied from less than 10 nm to more than 100 nm. A single spectrum is acquired in about 2 sec. The SNR is about 230 at a wavelength of 2.2 microns for a Lambertian surface of 90-percent reflectance illuminated by the sun at normal incidence with 14.8-nm resolution, a 25 C background temperature, and no atmospheric attenuation. FOV-defining optics are coupled by a flexible fiber-optics bundle to the spectroradiometer, which consists of a concave holographic diffraction grating with a flat focal field imaged onto a 1024-element platinum silicide linear-array detector.

Smith, Mark W.

Comparison of Sun-Induced Chlorophyll Fluorescence Estimates Obtained from Four Portable Field Spectroradiometers

Remote Sensing of Sun-Induced Chlorophyll Fluorescence (SIF) is a research field of growing interest because it offers the potential to quantify actual photosynthesis and to monitor plant status. New satellite missions from the European Space Agency, such as the Earth Explorer 8 FLuorescence EXplorer (FLEX) mission-scheduled to launch in 2022 and aiming at SIF mapping-and from the National Aeronautics and Space Administration (NASA) such as the Orbiting Carbon Observatory-2 (OCO-2) sampling mission launched in July 2014, provide the capability to estimate SIF from space. The detection of the SIF signal from airborne and satellite platform is difficult and reliable ground level data are needed for calibration/validation. Several commercially available spectroradiometers are currently used to retrieve SIF in the field. This study presents a comparison exercise for evaluating the capability of four spectroradiometers to retrieve SIF. The results show that an accurate far-red SIF estimation can be achieved using spectroradiometers with an ultrafine resolution (less than 1 nm), while the red SIF estimation requires even higher spectral resolution (less than 0.5 nm). Moreover, it is shown that the Signal to Noise Ratio (SNR) plays a significant role in the precision of the far-red SIF measurements.

Julitta, Tommaso

Polarization-sensitive spectroradiometer - Two methods for overcoming the problems of measuring reflectance spectra

The spectra obtained using a spectroradiometer are incorrect if the incident light from the sample is polarized, and if, at the same time, polarization is introduced into the transmitted beam by components of the spectroradiometer. Two methods are proposed for obtaining correct power reflectance spectra. One way is to average two incorrect reflectance spectra, which are taken at mutually orthogonal angles of rotation of the radiometer about its optical axis. Another way is by averaging reflectance spectra of mutually orthogonal polarized light components. When the orientation of one component is chosen such that it is in the plane of polarization of the incoming light, the latter method also gives the correct degree of polarization.

Auer, S.

The correlation and quantification of airborne spectroradiometer data to turbidity measurements at Lake Powell, Utah

A water sampling program was accomplished at Lake Powell, Utah, during June 1975 for correlation to multispectral data obtained with a 500-channel airborne spectroradiometer. Field measurements were taken of percentage of light transmittance, surface temperature, pH and Secchi disk depth. Percentage of light transmittance was also measured in the laboratory for the water samples. Analyses of electron micrographs and suspended sediment concentration data for four water samples located at Hite Bridge, Mile 168, Mile 150 and Bullfrog Bay indicated differences in the composition and concentration of the particulate matter. Airborne spectroradiometer multispectral data were analyzed for the four sampling locations. The results showed that: (1) as the percentage of light transmittance of the water samples decreased, the reflected radiance increased; and (2) as the suspended sediment concentration (mg/l) increased, the reflected radiance increased in the 1-80 mg/l range. In conclusion, valuable qualitative information was obtained on surface turbidity for the Lake Powell water spectra. Also, the reflected radiance measured at a wavelength of 0.58 micron was directly correlated to the suspended sediment concentration.

Merry, C. J.

Infrared airborne spectroradiometer survey results in the western Nevada area

The Mark II airborne spectroradiometer system was flown over several geologic test sites in western Nevada. The infrared mineral absorption bands were observed and recorded for the first time using an airborne system with high spectral resolution in the 2.0 to 2.5 micron region. The data show that the hydrothermal alteration zone minerals, carbonates, and other minerals are clearly visible in the airborne survey mode. The finer spectral features that distinguish the various minerals with infrared bands are also clearly visible in the airborne survey data. Using specialized computer pattern recognition methods, it is possible to identify mineralogy and map alteration zones and lithologies by airborne spectroradiometer survey techniques.

Collins, W.

Comparison of CNES spherical and NASA hemispherical large aperture integrating sources. I - Using a laboratory transfer spectroradiometer. II - Using the SPOT-2 satellite instruments

CNES spherical and NASA hemispherical large aperture calibration sources are examined using a laboratory transfer spectroradiometer and SPOT-2 instruments. The sources, collected at Matra in France during October 1987, are compared in terms of absolute calibration, linearity, and uniformity. The laboratory transfer spectroradiometer data reveal that the calibration results correspond to within about 7 percent absolute accuracy level and the linearity of the CNES source with lamp level is good. It is observed using the satellite data that both sources have an excellent uniformity over a 4 deg field of view.

Guenther, B.

Forest and grassland ecosystem studies using the advanced solid-state array spectroradiometer

The advanced solid-state array spectroradiometer (ASAS) is an airborne, off-nadir pointing imaging spectroradiometer used to acquire bidirectional radiance data for terrestrial targets. As its platform aircraft flies over a target the sensor can image the target through a sequence of at least seven fore-to-aft view directions ranging up to 45 deg on either side of nadir. ASAS acquires data for 29 spectral bands in the visible and near-infrared portions of the spectrum with a resolution of 15 nm. ASAS data were recently acquired for a prairie ecosystem and a northern forest ecosystem. The data demonstrate the combined effects of reflectance anisotropy and increased atmospheric path length on off-nadir observations. One result of these effects is a variation in vegetation indices as a function of view direction. Normalized-difference-vegetation-indices for prairie grass, coniferous, and deciduous canopies varied up to 14 percent, 23 percent, and 6 percent, respectively, relative to nadir as a function of view zenith angle along the solar principal plane.

Irons, James R.

Remote sensing of surface hemispherical reflectance (albedo) using pointable multispectral imaging spectroradiometers

Remote techniques for determining albedo are examined in terms of the range of view angles required in the use of string techniques with the Moderate Resolution Imaging Spectroradiometer (MODIS) and the High Resolution Imaging Spectroradiometer (HIRIS). Ground data are used to compute full and half strings out to 15, 30, 45, and 60 degrees for various sun angles and ground cover types. A knowledge-based system is employed to evaluate both the visible and near-IR bands, and the results indicate errors of up to 7 percent for the MODIS data, HIRIS data, and the full-string +/- 60 degrees. In the cases of large extrapolations greater ranges of error are noted indicating that 60-deg systems are most effective. The error is increased in the case of sensor systems that only view in the fore or aft direction, and the MODIS full string for +/- 45 deg is also considered a good system.

Kimes, D. S.

Cooling rate of an active Hawaiian lava flow from nighttime spectroradiometer measurements

A narrow-band spectroradiometer has been used to make nighttime measurements of the Phase 50 eruption of Pu'u O'o, on the East Rift Zone of Kilauea Volcano, Hawaii. On February 19, 1992, a GER spectroradiometer was used to determine the cooling rate of an active lava flow. This instrument collects 12-bit data between 0.35 to 3.0 microns at a spectral resolution of 1-5 nm. Thirteen spectra of a single area on a pahoehoe flow field were collected over a 59 minute period (21:27-22:26 HST) from which the cooling of the lava surface has been investigated. A two-component thermal mixing model (Flynn, 1992) applied to data for the flow immediately on emplacement gave a best-fit crustal temperature of 768 C, a hot component at 1150 C, and a hot radiating area of 3.6 percent of the total area. Over a 52-minute period (within the time interval between flow resurfacings) the lava flow crust cooled by 358 to 410 C at a rate that was as high as 15 C/min. The observations have significance both for satellite observations of active volcanoes and for numerical models of the cooling of lava flows during their emplacement.

Flynn, Luke P.

Development of moored oceanographic spectroradiometer

Biospherical Instruments has successfully completed a NASA sponsored SBIR (Small Business Innovational Research Program) project to develop spectroradiometers capable of being deployed in the ocean for long periods of time. The completion of this project adds a valuable tool for the calibration of future spaceborne ocean color sensors and enables oceanographers to extend remote sensing optical techniques beyond the intermittent coverage of spaceborne sensors. Highlights of the project include two moorings totalling 8 months generating extensive sets of optical, biological, and physical data sets in the ocean off La Jolla, California, and a 70 day operational deployment of the resulting commercial product by the ONR and NASA sponsored BIOWATT program. Based on experience gained in these moorings, Biospherical Instruments has developed a new line of spectroradiometers designed to support the oceanographic remote sensing missions of NASA, the Navy, and various oceanographers.

Booth, Charles R.

A Second Generation Multi-Angle Imaging SpectroRadiometer (MISR-2)

The Multi-angle Imaging SpectroRadiometer (MISR) has been in Earth orbit since December 1999 on NASA's Terra spacecraft. This instrument provides new ways of looking at the Earth's atmosphere, clouds, and surface for the purpose of understanding the Earth's ecology, environment, and climate. To facilitate the potential future continuation of MISR's multi-angle observations, a study was undertaken in 1999 and 2000 under the Instrument Incubator Program (IIP) of NASA Code Y's Earth Science Technology Office (ESTO) to investigate and demonstrate the feasibility of a successor to MISR that will have greatly reduced size and mass. The kernel of the program was the design, construction, and testing of a highly miniaturized camera, one of the nine that would probably be used on a future space borne MISR-like instrument. This demonstrated that the size and mass reduction of the optical system and camera electronics are possible and that filters can be assembled to meet the miniaturized packaging requirements. An innovative, reflective optics design was used, enabling the wavelength range to be extended into the shortwave infrared. This was the smallest all-reflective camera ever produced by the contractor. A study was undertaken to determine the feasibility of implementing nine (multi-angle) cameras within a single structure. This resulted in several possible configurations. It would also be possible to incorporate one of the cameras into an airborne instrument.

spectroradiometers

Multi-angle Imaging SpectroRadiometer (MISR): Optical Characterization of the Spectralon Calibration Panels

The reflectance properties of an engineering model of the Spectralon panel intended for use within an On-Board Calibrator (OBC) on the NASA Multi-angle Imaging SpectroRadiometer (MISR) instrument have been fully characterized with regard to panel uniformity and isotropy in response to three incident laser wavelengths of 442, 632.8 and 859.9 nm. A regional variation in bidirectional reflectance function (BRF) across the surface of the engineering model (EM) panel, contributing to spatial non-uniformity at the +/-2% level has been measured at all three laser wavelengths. Further, a BRF anisotropy has been identified. The mechanism causing these departures from the ideal Lambertian surface may originate in the sanding of the Spectralon surface in the final stage of preparation. This is corroborated by measurements made on a 'pressed' polytetrafluoroethylene (PTFE) panel in which a greatly reduced anisotropy in panel BRF is measured. The EM panel BRF reveals deviation from a Lambertian characteristic manifest as an off-specular peak in the forward scattering direction. A common cross-over point at an angle of reflection of around 37 at which the BRF is constant within 0.4% for an illumination angle range of ui = 30 60 is observed at all three wavelengths. Two Spectralon protoflight panels which were fabricated after the engineering model was studied were also the subject of a uniformity study over part of the area of the Spectralon panels at the 442 nm wavelength. The analysis indicated that the panel uniformity satisfies the 0.5% criterion indicating improved panel preparation. However, the off specular peak in the forward scattering direction is essentially unchanged with the cross-over point at approximately 37.

Multi-angle Imaging SpectroRadiometer

Development of an Operational System for the Retrieval of Aerosol and Land Surface Properties from the Terra Multi-Angle Imaging SpectroRadiometer

An operational system to retrieve atmospheric aerosol and land surface properties using data from the Multi-angle Imaging SpectroRadiometer (MISR) instrument, currently flying onboard NASA's Terra spacecraft, has been deployed. The system is in full operation, with new data products generated daily and distributed to science users worldwide. This paper describes the evolution of the system, from initial requirements definition and prototyping through design, implementation, testing, operational deployment, checkout and maintenance activities. The current status of the system and future plans for enhancement are described. Major challenges encountered during implementation are detailed.

aerosols