Engineering PapersSearch

SEARCH · Engineering Papers

Results for “solenoidal spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Tritium targets for use in solenoidal spectrometers

Nucleon adding and removing reactions are an ideal probe to study the single-particle foundations of nuclear structure. For experiments far away from the valley of stability, one needs to use radioactive beams in inverse kinematics. To maintain excellent resolution, solenoidal spectrometers like HELIOS at Argonne National Laboratory (ANL), ISS at CERN or SOLARIS at the Facility for Rare Isotope Beams (FRIB) are used. Typically, deuterated plastic foils are the targets of choice. Depending on the energy deposited, these targets might degrade quickly in beam. The potential of using tritium-implanted targets in conjunction with the solenoidal spectrometers was realized for access to even more exotic nuclei with outstanding resolving power. While no tritiated polyethylene is commercially available at the moment, tritium-containing titanium targets have been produced in the past. Unfortunately the loading fraction of tritium for the latter was often very low and not reproducible. The progress in the production of tritium-containing targets is presented, including the characterization of the foils.

Müller-Gatermann, Claus

𝑁 = 8 Shell Breaking in 12 Be from a Single-Particle Perspective

Experimental observations of the low-lying states in 12 Be and their accurate modeling play an essential role in understanding the disappearance of the 𝑁 = 8 magic number. Long-standing experimental ambiguities have been clarified using an one-neutron adding (𝑑, 𝑝) reaction on 11 Be using the ISOLDE Solenoidal Spectrometer at CERN’s HIE-ISOLDE facility. The single-particle energies of 1⁢𝑠 1/2 , 0⁢𝑑 5/2 , and 0⁢𝑝 1/2 orbitals in 12 Be have been determined from the extracted spectroscopic factors. A significant reduction between the separation of 1⁢𝑠 1/2 and 0⁢𝑝 1/2 orbitals is found in comparison with the carbon isotones, highlighting the breakdown of the 𝑁 = 8 shell. These observations serve as an important test of different effects incorporated in theoretical models. It is found that two synergistic mechanisms, core deformation and weak binding, are responsible for the 𝑁 = 8 shell breaking and the exotic near-threshold phenomena observed in 12 Be, including the narrow unnatural-parity resonance $0^{-}_1$ and the possible halolike nature of the $0^+_2$ isomer.

Chen, Jie [Southern University of Science and Tech

Study of multiple cycles valves

A discussion is presented regarding valves which can be cycled repeatedly and are available from industry for application in the inlet system for the Pioneer Venus Probe mass spectrometer. Both solenoid type and latching type valves are considered. The study is divided into two principal areas: (1) preparation of a valve specification reflecting the requirements of the inlet system cyclic valves for the Pioneer Venus Probe mass spectrometer and the submittal of this specification to potential valve suppliers for their response and proposal; (2) preparation of a design layout of an optimum cyclic valve meeting all of the valve specification requirements.

Wichmann, H.

Status of the Jefferson Lab Eta Factory (JEF) experiment

The Jefferson Lab Eta Factory (JEF) experiment is an experiment running in Hall D at Jefferson Lab that focuses on studying the decays of the ¿ meson. These decays provide a rich laboratory for searching for new charge conjugation violating / parity conserving (CVPC) processes, looking for hints of Beyond Standard Model physics, and probing higher order terms in Chiral Perturbation Theory. The flagship channel is the rare decay ¿ ¿ p0¿¿, the measurement of which required an upgrade to the existing equipment in Hall D. The experiment uses the GlueX detector, a fixed-target large acceptance spectrometer based on a solenoid magnet containing drift chambers for tracking charged particles and a lead-scintillator barrel calorimeter in the central region and an array of 4 × 4 × 45 cm3 lead glass blocks in the forward region for detecting neutral particles. During the last two years the inner 80×80 cm2 region of the forward calorimeter has been replaced by an array of 2 × 2 × 20 cm3 lead tungstate crystals, which provide factors of two improvement in energy and position resolution. The first round of data taking with this configuration took place this year. A first look at the data will be presented.

Taylor, Simon [Thomas Jefferson National Accelerat

Direct reactions with the AT-TPC

Direct reactions are crucial tools for accessing properties of the atomic nucleus. Fundamental and exotic phenomena such as collective modes, pairing, weakbinding effects and evolution of single-particles energies can be investigated in peripheral collisions between a heavy nucleus and a light target. The necessity of using inverse kinematics to reveal how these structural properties change with isospin imbalance renders direct reactions a challenging technique when using the missing mass method. In this scenario, Active Target Time Projection Chambers (AT-TPC) have demonstrated an outstanding performance in enabling these types of reactions even under conditions of very low beam intensities. The AT-TPC of the Facility for Rare Isotope Beams (FRIB) is a next generation multipurpose Active Target. When operated inside a solenoidal magnet, direct reactions benefit from the measurement of the magnetic rigidity that enables particle identification and the determination of the excitation energy with high resolution without the need of auxiliary detectors. Additionally, the AT-TPC can be coupled to a magnetic spectrometer improving even further its spectroscopic investigation capability. In this contribution, we discuss inelastic scattering and transfer reaction data obtained via the AT-TPC and compare them to theory. In particular, we present the results for the 14 C(p,p′) and 12 Be (p,d) 11 Be reactions. For 14 C, we compare the experimental excitation energy of the first 1 – excited state with coupled-cluster calculationsbased on nuclear interactions from chiral effective field theory and with available shell-model predictions. For 12 Be, we determine the theoretical spectroscopic factors of the 12 Be (p,d) 11 Be transfer reaction in the shell modeland compare them to the experimental excitation spectrum from a qualitative standpoint.

active target

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND