Engineering PapersSearch

SEARCH · Engineering Papers

Results for “software measurement software faults software reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Machine learning for photovoltaic single axis tracker fault detection and classification

More than 81% of the annual capacity of utility-scale photovoltaic (PV) power plants in the U.S. use single-axis trackers (SATs) due to SATs delivering 4% in capacity factor on average over fixed-array systems. However, SATs are subject to faults, such as software misconfigurations and mechanical failures, resulting in suboptimal tracking. If left undetected, the overall power yield of the PV power plant is reduced significantly. Minimizing downtime and ensuring efficient operation of SATs requires robust detection and diagnosis mechanisms for SAT faults. We present a machine learning framework for implementing real-time SAT fault detection and classification. Our implementation of the proposed framework reliably identifies measurements taken from a test PV system undergoing emulated SAT faults relative to state-of-the-art algorithms and produces nearly zero false positives on our testing days. Code and data are available at https://pvpmc.sandia.gov/tools.

Fault classification

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]