Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “smps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Revisiting matrix-based inversion of scanning mobility particle sizer (SMPS) and humidified tandem differential mobility analyzer (HTDMA) data

Abstract. Tikhonov regularization is a tool for reducing noise amplification during data inversion. This work introduces RegularizationTools.jl, a general-purpose software package for applying Tikhonov regularization to data. The package implements well-established numerical algorithms and is suitable for systems of up to ∼ 1000 equations. Included is an abstraction to systematically categorize specific inversion configurations and their associated hyperparameters. A generic interface translates arbitrary linear forward models defined by a computer function into the corresponding design matrix. This obviates the need to explicitly write out and discretize the Fredholm integral equation, thus facilitating fast prototyping of new regularization schemes associated with measurement techniques. Example applications include the inversion involving data from scanning mobility particle sizers (SMPSs) and humidified tandem differential mobility analyzers (HTDMAs). Inversion of SMPS size distributions reported in this work builds upon the freely available software DifferentialMobilityAnalyzers.jl. The speed of inversion is improved by a factor of ∼ 200, now requiring between 2 and 5 ms per SMPS scan when using 120 size bins. Previously reported occasional failure to converge to a valid solution is reduced by switching from the L-curve method to generalized cross-validation as the metric to search for the optimal regularization parameter. Higher-order inversions resulting in smooth, denoised reconstructions of size distributions are now included in DifferentialMobilityAnalyzers.jl. This work also demonstrates that an SMPS-style matrix-based inversion can be applied to find the growth factor frequency distribution from raw HTDMA data while also accounting for multiply charged particles. The outcome of the aerosol-related inversion methods is showcased by inverting multi-week SMPS and HTDMA datasets from ground-based observations, including SMPS data obtained at Bodega Marine Laboratory during the CalWater 2/ACAPEX campaign and co-located SMPS and HTDMA data collected at the US Department of Energy observatory located at the Southern Great Plains site in Oklahoma, USA. Results show that the proposed approaches are suitable for unsupervised, nonparametric inversion of large-scale datasets as well as inversion in real time during data acquisition on low-cost reduced-instruction-set architectures used in single-board computers. The included software implementation of Tikhonov regularization is freely available, general, and domain-independent and thus can be applied to many other inverse problems arising in atmospheric measurement techniques and beyond.

54 ENVIRONMENTAL SCIENCES↗

SMPS data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow, 1.0 LPM, is directed through TSI's 0.071 cm impactor attached to the classifier of the SMPS setup. The SMPS’s DMA and CPC are connected through a 20.3 cm length of 0.48 cm diameter tubing. Measured SMPS size distributions were used to calculate size-dependent particle losses for each SMPS scan. Particle losses from diffusion (based on Kesten, 1991 and Gormley, 1949) and inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977) were included in the loss calculation. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

54 ENVIRONMENTAL SCIENCES↗

Scanning Mobility Particle Sizer (SMPS) Instrument Handbook

The Model 3936 Scanning Mobility Particle Spectrometer (SMPS) measures the size distribution of aerosols ranging from 10 nm up to 1000 nm. The SMPS uses a bipolar aerosol charger to keep particles within a known charge distribution. Charged particles are classified according to their electrical mobility, using a long-column differential mobility analyzer (DMA). Particle concentration is measured with a condensation particle counter (CPC). The SMPS is well-suited for applications including: nanoparticle research, atmospheric aerosol studies, pollution studies, smog chamber evaluations, engine exhaust and combustion studies, materials synthesis, filter efficiency testing, nucleation/condensation studies, and rapidly changing aerosol systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intercomparison of Aerosol Instrumental Responses Using AEROTRAK, SMPS, and APS in a Simulated Building

In this work, three aerosol instruments were intercompared by using data collected from field campaigns in a simulated building environment during the last quarter of 2020 from October to December at Oak Ridge National Laboratory. The three aerosol instruments—AeroTrak Model 9110, Scanning Mobility Particle Spectrometer (SMPS) 3080L + 3025A, and Aerodynamic Particle Sizer (APS) 3320—were manufactured by TSI Inc. to perform in situ measurements of particle number concentration in the air. These instruments were co-located in one room in which an aerosol generator was used to produce a defined aerosol population for the instruments to sample and detect in each campaign. The SMPS measured aerosol particles with diameters from 0.01 to 0.7 µm, APS measured aerosol particles with diameters from 0.5 to 20 µm, and AeroTrak measured aerosol particles with diameters from 0.1 to 10 µm. The results suggest that although AeroTrak is fast and easy to use, it does not provide measurements comparable with those obtained by SMPS and APS. The differences in particle counts were orders of magnitude in size (i.e., the AeroTrak data were unreasonably small in the tested scenarios). The results clearly indicate that AeroTrak should not be used in ambient applications in which the level of particle concentration is expected to be high. This would cause difficulty to a campaign in which the dilution factor is unknow a priori. The high particle concentration could also lead to an erroneous aerosol size distribution (e.g., a bimodal size distribution was measured as opposed to a single-mode one). The number concentration limit that AeroTrak is expected to run reliably (i.e., with a counting coincidence error less than ±10%) is approximately three to four per cubic centimeter. This suggests that the instrument is best used in a clean room environment, not in an ambient or indoor application, such as the Flexible Research Platform campaigns.

47 OTHER INSTRUMENTATION↗

Design, characterization and shape recovery behavior of 3D/4D printed shape memory polymers (SMPs)

Shape memory polymers (SMPs) represent a paradigm shift in material science, uniquely capable of undergoing reversible shape transformations triggered by external stimuli, positioning them as pivotal in developing next-generation biomedical devices, aerospace components, and adaptive structures. Extensive research has been done on SMPs with a major focus on high-temperature programming methods, which can limit energy efficiency and applicability with temperature-sensitive materials. Additionally, while various SMP blends have demonstrated great potential, limited work has been done on the suitability for 3D printing these materials, particularly under high-strain and ambient temperature programming conditions. In this study, a three-component optimized SMP composition was evaluated by 3D printing via the Material Extrusion (MEX) technique and investigating its ambient temperature-programming behavior at high strains. The SMP formulation studied was a tailored blend of thermoplastic polyurethane (TPU), polycaprolactone (PCL), and an octadecane diol-based copolymer (OBC) that exhibits robust shape memory behavior, high strain tolerance, and efficient force generation. Rigorous thermal, mechanical, and shape recovery analyses, along with optimized printing parameters and consistent shape recovery rates of up to 90%, were achieved under dynamic mechanical analysis (DMA), even under ambient programming conditions. This work demonstrates the SMP composition’s potential for adaptive, self-deployable systems with 4D printing characteristics ideal for bio-inspired structures and artificial muscle fibers.

Sudan, Kavish [University of Louisville, KY]↗

Merged aerosol size distribution from SMPS and OPC for SAIL

This dataset contains merged aerosol number size distribution data for the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign. The merged size distribution data were constructed by combining measurements from a scanning-mobility particle sizer (SMPS) and an optical particle counter (OPC), covering a size range of 0.01–35 µm. The merging methodology follows the approach described by Hand and Kreidenweis (2002) and Marinescu et al. (2019). All aerosol data from the ARM archive were corrected to standard temperature (273.15 K) and pressure (101.3 kPa).

merged size distribution↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - SMPS

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

Particle number size distributions (10-461 nm) measured by SMPS at the ENA site during the AGENA campaign

During the Aerosol Growth in the Eastern North Atlantic (AGENA) campaign at the ENA site, particle number size distributions ranging from 10.6 to 461 nm were measured using SMPS with a time resolution of 4 minutes. The local pollution was identified and flagged by the “pollutionflag” field, where 0 denotes the clean periods and 1 denotes the polluted periods.

54 ENVIRONMENTAL SCIENCES↗

Scanning Mobility Particle Sizer (SMPS)-Aerodynamic Particle Sizer (APS) Merged Size Distribution (mergedsmpsaps) Value-Added Product Report

Aerosol particles influence the Earth’s radiation balance directly by absorbing and scattering light and indirectly by influencing cloud formation, properties, and lifetimes. Measurements of aerosol particle optical properties, mass loading, size distributions, microphysical properties, cloud formation properties, and chemical composition are important for understanding the aerosol life cycle and for validating earth system models that predict these quantities. The Atmospheric Radiation Measurement (ARM) user facility’s Aerosol Observing System (AOS) is a highly instrumented platform designed to house instruments that measure many of these aerosol properties in situ. Currently, ARM operates at least four different instruments that measure a portion of the ambient aerosol size distribution. Most users are interested in the entire size distribution or a portion of the size distribution that extends across the measurement range of multiple instruments. However, merging these distributions is not trivial as the instruments employ different measurement principals and, in most cases, report data as a function of different representations of the aerosol diameter.

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-UCDAVIS Aerosol Optical Properties and Sizing - smps

Aerosol size distribution and optical properties collected in La Port TX, during TRACER-CAT-UCDavis, July 2022. Speciated particle composition measurements are reported separately. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by UC Davis (TRACER-CAT-UCDavis, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-UCDavis is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments include: UC Davis two-wavelength cavity ringdown-photoacoustic spectrometer (CRD-PAS); Brechtel scanning electrical mobility sizer (SEMS); modified humidified cavity attenuated phase shift spectrometer with single scatter albedo (H-CAPS-SSA)

54 ENVIRONMENTAL SCIENCES↗

Hyperbranched PDMAEMA-functionalized SiO 2 microparticles: ATRP polymerization and grafting in a continuous flow reactor

Flow chemistry offers high reaction yield, kinetic control, improved safety, reliability, scalability, and greater degree of process control. Herein, hyperbranched polymer-grafted silica microparticles (HP-SMPs) are synthesized in a commercially available flow reactor through atom transfer radical polymerization. Initiator-anchored silica microparticles are obtained by in situ silanization in the flow reactor. Hyperbranched poly[2-(dimethylamino)ethylmethacrylate] chains are grafted onto the initiator-anchored SMPs through inimer–monomer ratio control. To demonstrate the efficiency and universality of this approach in grafting polymers onto SMPs, multiple hyperbranched polymeric structures are obtained by varying the inimer concentration. Dye absorption test is conducted to demonstrate the potential applications of HP-SMPs.

36 MATERIALS SCIENCE↗

CPC data from TAMU TRACER campaign in the Houston, TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.3 LPM is directed to the CPC. To correct the data for particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate total particle loss through the inlet for every SMPS scan at a single deployment location. Second, the CPC data was corrected for particle losses using the average of the total losses per scan. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. An additional flatline correction of 14% was applied to all CPC data based on laboratory calibration prior to and after the campaign. In laboratory calibrations, we identified that for the same sample of air the field CPC (GRIMM Model 5.403 CPC) undercounted the total concentration of particles by 14% compared to the ground truth laboratory CPC (TSI Model 3750). This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Efficiency, Power Loss, and Power Factor Measurement of Quadrupole Magnet Power Supplies at the Spallation Neutron Source

The linear accelerator (LINAC) quadrupole magnets are powered by 42 silicon-controlled rectifier (SCR) based power supplies at the Spallation Neutron Source (SNS) facility of Oak Ridge National Laboratory. These 35V, 525A power supplies are bulky, inefficient and require both air and water cooling. The reliability of the SNS facility is impacted due to water leaks internal to power supplies and current readback issues associated with their unique control system interface, resulting in multiple downtime events. Hence, an alternate solution is necessary for the continued reliable operation of the SNS. To mitigate the above-mentioned problems, this paper proposes the use of off-the-shelf Switch Mode Power Supplies (SMPS) rated for 20V, 500A with serial control interface. These SMPS are air-cooled, more efficient and more compact owing to their switching speeds of approximately 160 kHz. The performance enhancements of the SMPS in comparison with the existing SCR power supply are discussed in detail in this paper. The features of the SMPS, along with experimental results for both power supplies, like efficiency, power losses and stability, are presented. Ongoing work is also discussed.

Harave, Sudarshan↗

Melting of spatially modulated phases at domain wall/surface junctions in antiferrodistortive multiferroics

A physical understanding of the nature of spatially modulated phases (SMPs) in rare-earth-doped antiferrodistortive (AFD) multiferroics and how they behave close to surfaces and interfaces is lacking. Here the emergence of the antiferroelectric (AFE), ferroelectric (FE), or ferrielectric (AFE-FE) spatial modulation in the vicinity of the morphotropic phase transition in La x Bi 1 – x Fe O 3 ( x ~ 0.2 ) is explored on the atomic level using high-resolution scanning transmission electron microscopy (HRSTEM). The suppression, or “melting,” of the AFE-type SMP in the vicinity of the AFD twin wall/surface junction is revealed by HRSTEM in La 0.22 Bi 0.78 Fe O 3 films and explained by the hybrid approach combining Landau-Ginzburg-Devonshire (LGD) phenomenology and the semimicroscopic four-sublattice model (FSM). The LGD-FSM approach reduces the problem of AFE (or AFE-FE) SMP emergence and stability to the thermodynamic analysis of the free-energy functional with AFE, FE, and AFD long-range order parameters and two master parameters: the FE-AFE coupling strength between four neighboring A sites and the nonstoichiometry factor, which are proportional to the variations of La concentration in La x Bi 1 – x Fe O 3 films. Finally, we establish that the surface-induced melting of SMPs and the associated broadening of AFE AFD domain walls minimize the film free energy under certain conditions imposed on the master parameters and gradient energy below the critical value. The observed behavior provides insight into the origin of SMPs in AFD multiferroics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stent with expandable foam

A system comprising first, second, and third shape memory polymers (SMPs); wherein (a) the first SMP is a biodegradable open cell foam that includes a first channel; (b) the second SMP includes a second channel and is included in the first channel; (c) the foam is in a first state and is configured to expand to a second state, radially outward from the second foam, in response to thermal stimulus; (d) the third SMP is between the first and second SMPs and includes a stent having a first strut that includes the third SMP and a second strut that includes the third SMP; and (e) each of the first, second, and third SMPs is coupled to a wire.

Wilson, Thomas S.↗

CACTI: Best Estimate Aerosol Size Distribution by airborne measurements

These data were collected during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI; https://www.arm.gov/research/campaigns/amf2018cacti ) field campaign in the Sierras de Córdoba mountain range of north-central Argentina as part of ARM Aerial Facility (AAF) deployment. The ARM Aerial Facility Gulfstream-1 was operated from Las Higueras Airport (IATA: RCU, ICAO: SAOC), Río Cuarto, Córdoba, Argentina, for the Intensive Observation Period (IOP) from Nov. 1 through Dec. 15, 2018. The G-1 aircraft performed 22 research flights over the first ARM Mobile Facility (AMF1) location in the Sierras de Córdoba mountain range to measure atmospheric state and turbulence, cloud water content and droplet size distributions, aerosol precursor gases, aerosol chemical composition and size distributions. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 5 sensors; three aerosol spectrometers: Scanning Mobility Particle Sizer (SMPS), Ultra-High Sensitivity Aerosol Spectrometer (UHSAS), and Passive Cavity Aerosol Spectrometer (PCASP); and two cloud probes: Cloud Aerosol Spectrometer (CAS) and Fast Cloud Droplet Probe (FCDP). The SMPS data were interpolated to 1 second from “native” time resolution of about 64 second to match all other probes.

54 ENVIRONMENTAL SCIENCES↗

Self-assembly of wood-based shape memory composites triggered by solar-thermal energy

Transporting and assembling large, complex structures poses significant challenges due to their size, geometry, and cost. Additionally, the installation sites are often inaccessible or hazardous for humans, necessitating self-assembling capabilities in these structures. To mitigate these challenges, we propose using 3D printing materials with shape memory effect (SME) for both transport and construction. This approach involves developing 3D modular components into flat sheets for easier transportation, and then self-assembling into 3D structures on-site using solar energy. To gain a deeper understanding of the factors influencing material memory performance, we have chosen a composite PLA/WF, which is polylactic acid (PLA) with 20 wt% wood flour (WF) for this purpose, leveraging its high tensile modulus at 0.966 GPa, low cost, and sustainability. Printed shapes with this material can maintain a recovery ratio over 90% after 3 cycles. While traditional composites fillers (e.g. glass or carbon fiber) are added to enhance mechanical and thermal properties, the addition of bio-based fillers like WF accomplish similar goals without compromising sustainability. We conducted multiple experiments to demonstrate how environmental conditions (i.e. temperature) maximize the material’s SME. Although still at an early stage, this study provides initial insights into bridging the gap between the small-scale nature of shape memory polymers (SMPs) and their potential for large-scale additive manufacturing, addressing a critical need for efficient and sustainable construction. In the long term, we hope our study contributes to the design vision of utilizing SMPs for transportation, assembly, and deployment of complex structures, providing a new pathway for sustainable construction and transportation of large-scale structures to hard-to-access locations such as disaster-affected areas and remote deserts, etc.

4D printing↗