Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “smear samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Energetic electrons in the magnetophere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980b). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(sub s)(exp 2)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Energetic electrons in the magnetosphere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(exp 2, sub s)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Compact, Automated Centrifugal Slide-Staining System

The Directional Acceleration Vector-Driven Displacement of Fluids (DAVD-DOF) system, under development at the time of reporting the information for this article, would be a relatively compact, automated, centrifugally actuated system for staining blood smears and other microbiological samples on glass microscope slides in either a microgravitational or a normal Earth gravitational environment. The DAVD-DOF concept is a successor to the centrifuge-operated slide stainer (COSS) concept, which was reported in Slide-Staining System for Microgravity or Gravity (MSC-22949), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 64. The COSS includes reservoirs and a staining chamber that contains a microscope slide to which a biological sample is affixed. The staining chamber is sequentially filled with and drained of staining and related liquids from the reservoirs by use of a weighted plunger to force liquid from one reservoir to another at a constant level of hypergravity maintained in a standard swing-bucket centrifuge. In the DAVD-DOF system, a staining chamber containing a sample would also be sequentially filled and emptied, but with important differences. Instead of a simple microscope slide, one would use a special microscope slide on which would be fabricated a network of very small reservoirs and narrow channels connected to a staining chamber (see figure). Unlike in the COSS, displacement of liquid would be effected by use of the weight of the liquid itself, rather than the weight of a plunger.

Feeback, Daniel L.↗

BATSE analysis techniques for probing the GRB spatial and luminosity distributions

The Burst And Transient Source Experiment (BATSE) has measured homogeneity and isotropy parameters from an increasingly large sample of observed gamma-ray bursts (GRBs), while also maintaining a summary of the way in which the sky has been sampled. Measurement of both of these are necessary for any study of the BATSE data statistically, as they take into account the most serious observational selection effects known in the study of GRBs: beam-smearing and inhomogeneous, anisotropic sky sampling. Knowledge of these effects is important to analysis of GRB angular and intensity distributions. In addition to determining that the bursts are local, it is hoped that analysis of such distributions will allow boundaries to be placed on the true GRB spatial distribution and luminosity function. The technique for studying GRB spatial and luminosity distributions is direct. Results of BATSE analyses are compared to Monte Carlo models parameterized by a variety of spatial and luminosity characteristics.

Hakkila, Jon↗

Determination of Small Animal Long Bone Properties Using Densitometry

Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

Breit, Gregory A.↗

Improved particulate-sampling filter

Small surface indentations entrain larger and more representative sampling than conventional petri-dish smeared with smooth layer adhesive. Filter is assembled from perforated disk and flat backing plate with sticky surface. Due to design-created currents, particulates come in contact with surface for longer time and have greater probability of being trapped. Filter is useful in air-quality monitoring at industrial sites, in mines, and in and around nuclear power plants.

Hoffman, A. R.↗

Space infrared telescope pointing control system. Infrared telescope tracking in the presence of target motion

The use of charge-coupled-devices, or CCD's, has been documented by a number of sources as an effective means of providing a measurement of spacecraft attitude with respect to the stars. A method exists of defocussing and interpolation of the resulting shape of a star image over a small subsection of a large CCD array. This yields an increase in the accuracy of the device by better than an order of magnitude over the case when the star image is focussed upon a single CCD pixel. This research examines the effect that image motion has upon the overall precision of this star sensor when applied to an orbiting infrared observatory. While CCD's collect energy within the visible spectrum of light, the targets of scientific interest may well have no appreciable visible emissions. Image motion has the effect of smearing the image of the star in the direction of motion during a particular sampling interval. The presence of image motion is incorporated into a Kalman filter for the system, and it is shown that the addition of a gyro command term is adequate to compensate for the effect of image motion in the measurement. The updated gyro model is included in this analysis, but has natural frequencies faster than the projected star tracker sample rate for dim stars. The system state equations are reduced by modelling gyro drift as a white noise process. There exists a tradeoff in selected star tracker sample time between the CCD, which has improved noise characteristics as sample time increases, and the gyro, which will potentially drift further between long attitude updates. A sample time which minimizes pointing estimation error exists for the random drift gyro model as well as for a random walk gyro model.

Powell, J. D.↗

Estrous Cyclicity in Mice During Simulated Weightlessness

Hindlimb unloading (HU) is a rodent model system used to simulate weightlessness experienced in space. However, some effects of this approach on rodent physiology are under-studied, specifically the effects on ovarian estrogen production which drives the estrous cycle. To resolve this deficiency, we conducted a ground-based validation study using the HU model, while monitoring estrous cycles in 16-weeks-old female C57BL6 mice. Animals were exposed to HU for 12 days following a 3 day HU cage acclimation period, and estrous cycling was analyzed in HU animals (n=22), normally loaded HU Cage Pair-Fed controls (CPF; n=22), and Vivarium controls fed ad libitum (VIV; n=10). Pair feeding was used to control for potential nutritional deficits on ovarian function. Vaginal cells were sampled daily in all mice via saline lavage. Cells were dried and stained with crystal violet, and the smears evaluated using established vaginal cytology techniques by two individuals blinded to the animal treatment group. Estrous cyclicity was disrupted in nearly all HU and CPF mice, while those maintained in VIV had an average normal cycle length of 4.8+/- 0.5 days, with all stages in the cycle visibly observed. CPF and HU animals arrested in the diestrous phase, which precedes the pre-ovulatory estrogen surge. Additionally, infection-like symptoms characterized by vaginal discharge and swelling arose in several HU animals, which we suspect was due to an inability of these mice to properly groom themselves, and/or due to the change in the gravity vector relative to the vaginal opening, which prevented drainage of the lavage solution. Pair-feeding resulted in similar weight gains of HU and CPF (1.5% vs 3.0%, respectively). The current results indicate that pair-feeding controlled weight gain and that the HU cage alone influenced estrous cyclicity. Thus, longer acclimation needs to be tested to determine if and when normal estrous cycling resumes in non-loaded mice in HU cages prior to HU testing. Future studies might also examine whether modifications to the vaginal lavage procedure might prevent the onset of the infection-like symptoms, and allow estrous cyclicity to be measured in this model system. Research supported by NNX15AB48G to JST.

Hindlimb Unloading↗

Estrous Cyclicity of Mice During Simulated Weightlessness

Hindlimb unloading (HU) is a rodent model system used to simulate weightlessness experienced in space. However, some effects of this approach on rodent physiology are under-studied, specifically the effects on ovarian estrogen production which drives the estrous cycle. To resolve this deficiency, we conducted a ground-based validation study using the HU model, while monitoring estrous cycles in 16-weeks-old female C57BL6 mice. Animals were exposed to HU for 12 days following a 3 day HU cage acclimation period, and estrous cycling was analyzed in HU animals (n22), normally loaded HU Cage Pair-Fed controls (CPF; n22), and Vivarium controls fed ad libitum (VIV; n10). Pair feeding was used to control for potential nutritional deficits on ovarian function. Vaginal cells were sampled daily in all mice via saline lavage. Cells were dried and stained with crystal violet, and the smears evaluated using established vaginal cytology techniques by two individuals blinded to the animal treatment group. Estrous cyclicity was disrupted in nearly all HU and CPF mice, while those maintained in VIV had an average normal cycle length of 4.8 0.5 days, with all stages in the cycle visibly observed. CPF and HU animals arrested in the diestrous phase, which precedes the pre-ovulatory estrogen surge. Additionally, infection-like symptoms characterized by vaginal discharge and swelling arose in several HU animals, which we suspect was due to an inability of these mice to properly groom themselves, andor due to the change in the gravity vector relative to the vaginal opening, which prevented drainage of the lavage solution. Pair-feeding resulted in similar weight gains of HU and CPF (1.5 vs 3.0, respectively). The current results indicate that pair-feeding controlled weight gain and that the HU cage alone influenced estrous cyclicity. Thus, longer acclimation needs to be tested to determine if and when normal estrous cycling resumes in non-loaded mice in HU cages prior to HU testing. Future studies might also examine whether modifications to the vaginal lavage procedure might prevent the onset of the infection-like symptoms, and allow estrous cyclicity to be measured in this model system.

fertilit↗

Compression Behavior of Fluted-Core Composite Panels

In recent years, fiber-reinforced composites have become more accepted for aerospace applications. Specifically, during NASA s recent efforts to develop new launch vehicles, composite materials were considered and baselined for a number of structures. Because of mass and stiffness requirements, sandwich composites are often selected for many applications. However, there are a number of manufacturing and in-service concerns associated with traditional honeycomb-core sandwich composites that in certain instances may be alleviated through the use of other core materials or construction methods. Fluted-core, which consists of integral angled web members with structural radius fillers spaced between laminate face sheets, is one such construction alternative and is considered herein. Two different fluted-core designs were considered: a subscale design and a full-scale design sized for a heavy-lift-launch-vehicle interstage. In particular, axial compression of fluted-core composites was evaluated with experiments and finite-element analyses (FEA); axial compression is the primary loading condition in dry launch-vehicle barrel sections. Detailed finite-element models were developed to represent all components of the fluted-core construction, and geometrically nonlinear analyses were conducted to predict both buckling and material failures. Good agreement was obtained between test data and analyses, for both local buckling and ultimate material failure. Though the local buckling events are not catastrophic, the resulting deformations contribute to material failures. Consequently, an important observation is that the material failure loads and modes would not be captured by either linear analyses or nonlinear smeared-shell analyses. Compression-after-impact (CAI) performance of fluted core composites was also investigated by experimentally testing samples impacted with 6 ft.-lb. impact energies. It was found that such impacts reduced the ultimate load carrying capability by approximately 40% on the subscale test articles and by less than 20% on the full-scale test articles. Nondestructive inspection of the damage zones indicated that the detectable damage was limited to no more than one flute on either side of any given impact. More study is needed, but this may indicate that an inherent damage-arrest capability of fluted core could provide benefits over traditional sandwich designs in certain weight-critical applications.

Schultz, Marc R.↗

Heat capacity and thermal relaxation of bulk helium very near the lambda point

In October 1992 a low temperature experiment was flown on the Space Shuttle in low Earth orbit. The objective of the mission was to measure the heat capacity and thermal conductivity of helium very close to the lambda point with the smearing effect of gravity removed. We report preliminary results from the experiment, and compare them with related measurements performed on the ground. The sample was s sphere of helium 3.5 cm in diameter contained within a copper calorimeter of vey high thermal conductivity. The calorimeter was attached to a pair of high resolution paramagnetic salt thermometers with noise levels in the 10(exp -10) K range and suspended from a high stability thermal isolation system. During the mission we found that the resolution of the thermometers was degraded somewhat due to the impact of charged particles. This effect limited the useful resolution of the measurements to about two nanokelvins from the lambda point. The results reported here are limited to about ten nanokelvins from the transition.

Lipa, John A.↗

Prolonged triboluminescence in clays and other minerals

Samples of various clays and minerals were ground or fractured and monitored with a liquid scintillation spectrometer in order to obtain triboluminescent decay curves. Kaolinite samples displayed several million counts/min after grinding, with a surface area emission estimated at tens of billions of photons/sq cm of surface. The photon production rates varied with the origin of the sample, and kaolinite continually yielded higher production rates than bentonite. The addition of water to the samples slightly increased the count rate of emitted light, while the addition of the fluorescent molecule substance tryptofan significantly enhanced the count rate. Freezing smears of kaolinite and montmorillonite in liquid nitrogen and in a salt ice mixture also induced triboluminescence in the montmorillonite. A possible connection between powdery triboluminescent materials formed in mining industries and respiratory disorders among miners is suggested.

Lahav, N.↗

A Nanometer Aerosol Size Analyzer (nASA) for Rapid Measurement of High-Concentration Size Distributions

We have developed a fast-response Nanometer Aerosol Size Analyzer (nASA) that is capable of scanning 30 size channels between 3 and 100 nm in a total time of 3 seconds. The analyzer includes a bipolar charger (P0210), an extended-length Nanometer Differential Mobility Analyzer (Nano-DMA), and an electrometer (TSI 3068). This combination of components provides particle size spectra at a scan rate of 0.1 second per channel free of uncertainties caused by response-time-induced smearing. The nASA thus offers a fast response for aerosol size distribution measurements in high-concentration conditions and also eliminates the need for applying a de-smearing algorithm to resulting data. In addition, because of its thermodynamically stable means of particle detection, the nASA is useful for applications requiring measurements over a broad range of sample pressures and temperatures. Indeed, experimental transfer functions determined for the extended-length Nano-DMA using the Tandem Differential Mobility Analyzer (TDMA) technique indicate the nASA provides good size resolution at pressures as low as 200 Torr. Also, as was demonstrated in tests to characterize the soot emissions from the J85-GE engine of a T38 aircraft, the broad dynamic concentration range of the nASA makes it particularly suitable for studies of combustion or particle formation processes. Further details of the nASA performance as well as results from calibrations, laboratory tests and field applications are presented.

Han, Hee-Siew↗

Magnetic ordering of the polar airglow

The visible airglow experiment on the Atmosphere Explorer-C satellite has gathered sufficient data over the earth's polar regions to allow one to map the geographic distribution of particle precipitation using emissions at 3371 and 5200 A. Both of these features exhibit large variations in space and time. The 3371 A emission of N2(C cubed pi), excited by low energy electrons, indicates substantial energy inputs on the dayside in the vicinity of the polar cusp. More precipitation occurs in the morning than evening for the sample reported here, while the entire night sector between magnetic latitudes 65 and 77.5 deg is subjected to particle fluxes. Regions of enhanced 5200 A emission from N(D-2) are larger in horizontal extent than those at 3371 A. This smearing effect is due to ionospheric motions induced by magnetospheric convection.

Frederick, J. E.↗

Pixel-Level Calibration in the Kepler Science Operations Center Pipeline

We present an overview of the pixel-level calibration of flight data from the Kepler Mission performed within the Kepler Science Operations Center Science Processing Pipeline. This article describes the calibration (CAL) module, which operates on original spacecraft data to remove instrument effects and other artifacts that pollute the data. Traditional CCD data reduction is performed (removal of instrument/detector effects such as bias and dark current), in addition to pixel-level calibration (correcting for cosmic rays and variations in pixel sensitivity), Kepler-specific corrections (removing smear signals which result from the lack of a shutter on the photometer and correcting for distortions induced by the readout electronics), and additional operations that are needed due to the complexity and large volume of flight data. CAL operates on long (~30 min) and short (~1 min) sampled data, as well as full-frame images, and produces calibrated pixel flux time series, uncertainties, and other metrics that are used in subsequent Pipeline modules. The raw and calibrated data are also archived in the Multi-mission Archive at Space Telescope at the Space Telescope Science Institute for use by the astronomical community.

Calibration↗

Ensembles of radial basis function networks for spectroscopic detection of cervical precancer

The mortality related to cervical cancer can be substantially reduced through early detection and treatment. However, current detection techniques, such as Pap smear and colposcopy, fail to achieve a concurrently high sensitivity and specificity. In vivo fluorescence spectroscopy is a technique which quickly, noninvasively and quantitatively probes the biochemical and morphological changes that occur in precancerous tissue. A multivariate statistical algorithm was used to extract clinically useful information from tissue spectra acquired from 361 cervical sites from 95 patients at 337-, 380-, and 460-nm excitation wavelengths. The multivariate statistical analysis was also employed to reduce the number of fluorescence excitation-emission wavelength pairs required to discriminate healthy tissue samples from precancerous tissue samples. The use of connectionist methods such as multilayered perceptrons, radial basis function (RBF) networks, and ensembles of such networks was investigated. RBF ensemble algorithms based on fluorescence spectra potentially provide automated and near real-time implementation of precancer detection in the hands of nonexperts. The results are more reliable, direct, and accurate than those achieved by either human experts or multivariate statistical algorithms.

Cervix Neoplasms/pathology↗

Natural large-scale structures in the axisymmetric mixing layer

The present study is concerned with the optimization of conditional sampling techniques for eduction of naturally occurring large-scale structures in an axisymmetric mixing layer, and a comparison of the natural structure with that induced by means of controlled excitation. Questions regarding the sensitivity of the educed structure to the excitation amplitude are also explored. Aspects regarding the eduction with the high-speed-side reference signal are considered, taking into account structure identification, the smearing effect and a comparison with the structure under excitation, the effects of the threshold level, and the effect of a trigger-level window. Attention is given to structure characteristics and their dependence on Reynolds number and initial condition.

Zaman, K. B. M. Q.↗

Smeared Impedence Model for Variable Depth Liners

Noise from modern aircraft engines has a significant broadband component, which has motivated the need for broadband acoustic engine liners. A promising broadband design, called a variable depth liner, is composed of groups of resonators tuned for different frequencies. The accuracy of commonly used smeared impedance models, however, has not been thoroughly assessed for this type of liner. Therefore, the purpose of this study is to assess, and if necessary develop, semi-analytical impedance models for variable depth designs. The impedance prediction is complicated by the fact that the radiation loading on individual resonators within the array can be different. While the radiation loading can be neglected on conventional engine liners that consist of a dense array of uniform resonators, the same is not true for variable depth liners. To better understand and model this effect, nine liner samples are tested in the NASA Langley normal incidence tube. Comparisons of predicted and measured data for relatively simple non-uniform samples confirm that the radiation loading can be approximated using mass end correction terms. Semi-analytical impedance models that incorporate the proposed end corrections provide favorable comparisons with measured impedance spectra for variable depth liner samples.

Schiller, Noah H.↗