Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “smart facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

CommAwareNet: Towards Communication‐Aware Smart Facilities: Designing an Energy‐Efficient High‐Data‐Rate and Reliable Hybrid THz/VLC Comm. Arch. Reinforced with Intelligent Surfaces for Future Network

This project will develop foundations for energy-efficient, high-data-rate, and reliable communication links for next-generation advanced wireless technologies. The Internet of Everything is emerging as a major technology that can establish a massively connected network among both human-type users and machine-type devices. Particularly, massive machine-type communication is becoming the dominant communication paradigm for numerous emerging areas, including data center networking and wireless backhaul, healthcare (e-health), manufacturing (industry 4.0), utilities, transportation (connected cars and public safety), and virtual or augmented reality for human-machine interaction applications. The rising demand for high data rates, especially in indoor scenarios and densely populated outdoor environments, will eventually overload conventional RF-based technologies. This project aims to conduct fundamental research to design, optimize, and validate a communication-aware, energy-efficient, and reliable network (CommAwareNet) architecture for future smart facilities and environments that require unprecedented high throughput needs for massive numbers of the machine- and human-type users. The scientific and technical merit of this work lies in the research required to bring the proposed transformative CommAwareNet solution into fully functional and practical architecture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Designing Remote Monitoring for Smart Manufacturing Facilities: Hazard Identification and Classification

This study investigates the process of hazard identification in complex manufacturing environments during the design phase, emphasizing the significance of the design process in developing designs that effectively mitigate hazards in contexts with numerous variables, such as a variety of machines, sensors, actuators, and agents. Through a mixed-methods approach, the objective of this work is to understand how the evolution of design outcomes across various stages might influence a designer’s ability to recognize both standard and novel hazards. To achieve this understanding, an experimental design task was conducted with six designers from a national lab specializing in manufacturing technologies. This approach combined qualitative and quantitative data analysis from a one-hour virtual session with participants. Findings suggest that the complexity of identifying hazards in a high-dimensional design space is challenging within a limited time frame and that the identification of hazards is significantly influenced by the stage of the design task and the initial design decisions, indicating the need for extended time and strategic initial planning in the design process to enhance hazard identification.

Ballestas, Caseysimone↗

Artificial Intelligence for Data Center Operations (AIOps): Cooperative Research and Development (Final Report)

High performance computing data centers will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence and machine learning approaches provide the means to improve HPC data center operational efficiency, by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. NREL has developed methods of real-time collection, aggregation and streaming of these data in the ESIF HPC Data Center and has collected a significant dataset of relevant metrics across computer systems, racks, environmental, building and utility sources for research into various predictive analytics problems. HPE's Advanced Technology Group (ATG) is doing comprehensive research into exascale monitoring and management for High Performance Computing (HPC) systems (hereinafter HPE's Data Monitoring/ Management Technology). NREL and HPE will collaborate to add Artificial Intelligence (AI) to NREL's real-time data collection/ aggregation/ streaming system and HPE's Data Monitoring/ Management System, with the goal of improving the operational efficiency of NREL's Energy Systems Integration Facility (ESIF) HPC Data Center through data analytics on both historical and real-time data from IT systems and facilities operations. This collaboration will consist of efforts in Data Management, Data Analytics, and AI/ML Optimization for both manual and autonomous intervention in data center operations. This will be a multi-year, multi-staged effort with a goal towards building capabilities for an Advanced Smart Facility, and demonstration of these techniques in the NREL ESIF HPC Data Center.

97 MATHEMATICS AND COMPUTING↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

Artificial Intelligence for Data Center Operations (AI Ops)

HPC data centers such as the one at NREL's ESIF will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence (AI) and machine learning (ML) approaches provide the means to improve HPC data center efficiency (energy, operational, and managerial efficiency) and resiliency by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. The goal of coupled improvement of data center resiliency and energy efficiency through automated data collection and AI has led to a multi-year, multi-staged collaboration between NREL and Hewlett-Packard Enterprise's Advanced Technology Group, referred to as Artificial Intelligence for Data Center Operations (AIOps). The extended efforts within the AIOps project include a common goal of building capabilities for an advanced smart facility and demonstration of data collection and AI modeling techniques in the ESIF data center.

97 MATHEMATICS AND COMPUTING↗

From smart homes to smart laboratories: connected instruments for materials science

The current focus on artificial intelligence and machine learning in the scientific community has the potential to greatly speed up discovery. In this article, we explore what a “smart facility” would mean for materials science. We propose to capture meta-data at every step of an experiment, including materials synthesis, sample production and characterization, simulation, and the analysis software used to extract information. Although most of this information is captured in various institutional systems and staff logbooks, more insight could be obtained by connecting this information through a system that allows automation. AI-enabled processes built on such a system would have the potential of making experiment planning easier and minimize the time between experiment and publication.

Doucet, Mathieu↗

Smart Labs: Improving Lab Facilities to Meet Decarbonization Goals

Smart Labs enable safe and efficient world class science to occur in laboratories through high-performance methods. The Smart Labs Toolkit describes a systematic process to help laboratory owners and operators plan, assess, optimize, and manage laboratory facilities. This half-day workshop reviews the four phases of the Smart Labs Toolkit along with an interactive activity to complete a Laboratory Ventilation Risk Assessment. This session will also highlight the Lab Benchmarking Tool, which compares the energy use, emissions, and operational practices of lab buildings with similar facilities. Attendees will also discuss application as well as sharing tools and best practice guides.

assessment↗

Optimizing workplace charging facility deployment and smart charging strategies

This study introduces a workplace charging (WPC) optimization model that maximizes the total satisfied electric miles of employees’ plug-in electric vehicles, subject to a given annual budget. The model optimizes both planning decisions of charger number and power levels and operation decisions of charging spot assignment and charging schedule for the given temporal distribution of charging demands and varied electricity prices. Results of experiments based on national average travel data indicate that the actual WPC strategy varies by budget level. Through optimization, the strategy could reduce impacts of the varied electricity price by shifting charging schedules to periods when electricity prices are low. Also, the model is expanded to study the trade-off between providing WPC and addressing consequence of degraded charging service by including the per-mile shadow cost of unsatisfied charging demand. Finally, we observe that their relative competitiveness mainly depends on the actual shadow cost of WPC.

33 ADVANCED PROPULSION SYSTEMS↗

Subscale maturation of advanced reactor technologies (SMART): A path forward for nuclear thermal propulsion fuel and reactor development

Nuclear Thermal Propulsion (NTP) systems are actively being developed for future crewed missions to Mars. NTP systems excel in missions where both high thrust and high specific impulse are required, but modern NTP systems currently do not have a Technology Readiness Level (TRL) high enough for use in crewed space exploration. TRLs are used to demonstrate the level of rigor with which a component/system has been tested/demonstrated for its intended use. While space systems technology in general must be qualified as a unit, nuclear technology must be first demonstrated to meet qualification level requirements both at the fuel (component) level and the reactor (subsystem) level. Here, in this paper, historic NTP development programs are surveyed to identify a testing and development strategy that can be effectively implemented to allow for NTP reactor development. Based on this strategy, required facilities to enable such activities are identified. Current domestic experimental capabilities to support NTP qualification are limited to separate effects testing of individual components. Separate effects testing is found extensively in historic NTP development efforts but is not sufficient for full fuel and reactor qualification. Combined effects testing allows for an accurate assessment of fuel performance but is not achievable for NTP conditions in existing facilities. Assessment of historic development programs suggests that an intermediate, subscale test facility is necessary to advance NTP TRLs. A solution to meet this need is proposed, namely the Subscale Maturation of Advanced Reactor Technologies (SMART) facility. SMART will mitigate risk to NTP development by enabling performance and reactor physics demonstrations of NTP subsystems. A SMART facility could be built by modifying existing nuclear test facilities, which may potentially enable schedule and cost savings. To pursue reactor qualification beyond the subscale, a new ground test facility will be necessary. This ground test facility should be developed concurrently with SMART to allow for the facility to be operational in time for expedited NTP engine demonstration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FEST: Facility Energy Saving and Securing Technology Using Multi-Source Data: (Milestone 2 Report)

This project aims to demonstrate three technologies developed in-house at LLNL and University of Michigan-Dearborn (UMD), at a military site, including i) Grid Data Crossing (called GriD-Xing) for increasing smart meter data usability, ii) Facility Energy Optimization (called Facility E-GO) for improving facility energy efficiency in both operation and planning perspectives, and iii) Co-simulation tool (called Co-Sim) for enhancing smart meter and energy facility networks resilience and security. In this report, Millstone 2 - Integration A: Integrate GriD-Xing and facility optimization tools is documented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roundtable Report: Terahertz and 6G Wireless Communications in Science and Extreme Environments

The main objective of the roundtable is to bring together computer scientists and wireless communications experts from industry, academia, and government to explore the electromagnetic spectrum in the Terahertz (THz) bands for ultra-high-speed short-distance wireless communications in extreme environments. This new generation of THz wireless communications is the key to future machine-to-machine communications critical for the mass deployment of an intelligent Internet of Things (IoT). The roundtable discussion explores THz and 6G wireless technologies along with Visible Light Communications (VLC), intelligent reflection surfaces, free-space quantum and optical communications, and nano communications. The roundtable considers the suitability of these technologies for extreme environments from the nanoscale to the mesoscale for the following: scientific facilities and associated instruments, as well as industry, and manufacturing. Such use cases are not traditionally the primary customer of commercial wireless networks which are focused on personal broadband voice and data communications. Finally, the discussion identifies high-level opportunities and challenges for leveraging THz and 6G wireless communications and related Artificial Intelligence (AI) that can catalyze the advancement of the development of hyperconnected smart scientific instruments and facilities.

97 MATHEMATICS AND COMPUTING↗

Corrosion Detection Coatings

Explore the source record for details and available documents.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vegetation Management Lessons Learned and Helpful Tools

The InSPIRE Project is investigating questions around vegetation management and agrivoltaics at solar sites across the US. Results from research at three Enel Green Power pollinator-friendly solar sites in Minnesota have shown that the success of different pollinator-friendly seed mixes depend on the ecoregion and can vary from site to site. Results from the Enel Green Power sites also showed that weed coverage decreases dramatically by three years post seeding. The InSPIRE project has also created resources like The 5 C's of Agrivoltaics and an online agrivoltaics financial calculator to help farmers, land owners, developers, and facility operators with vegetation management at solar facilities. The PV-SMaRT calculator was created by the University of Minnesota in partnership with NREL to help with questions surrounding storm-water runoff at PV sites.

agrivoltaic↗

Smart Labs Final Report Summer 2021

The Smart Labs Project at Los Alamos National Laboratory (LANL) is an initiative derived from The University of California, Irvine and is part of the Department of Energy’s (DOE) Better Buildings Challenge. These carbon abatement strategies aim to reduce energy consumption of laboratories while also maintaining health and safety requirements. Smart Labs designs incorporate seven key principles which are: digital control systems, demand-based ventilation, low power-density demand-based lighting, exhaust fan discharge velocity optimization, pressure drop optimization, fume hood flow optimization, and commissioning with automated cross-platform fault detection. As the ALDCP Smart Labs team for the summer of 2021, the scope of the project is to determine the energy savings within building 03-1698 (Material Science Laboratory - MSL). Over the past couple of years, the Sustainability Group has been adding Smart Labs upgrades into the MSL building and the summer team would like to understand the impact made for the overall energy consumption/demand and safety for the building, determine the overall return on investment (ROI), and recommend more Smart Labs upgrades that can be added to the MSL building. The goal is to enable the UI FOD (Utilities and Infrastructure Facility Operation Division) to promote more Smart Labs projects in the future and further the reputation LANL and DOE facilities have of being leading examples of developers of high performing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗