Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “site detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multi-Resolution Elevation Mapping and Safe Landing Site Detection with Applications to Planetary Rotorcraft

In this paper, we propose a resource-efficient approach to provide an autonomous UAV with an on-board perception method to detect safe, hazard-free landing sites during flights over complex 3D terrain. We aggregate 3D measurements acquired from a sequence of monocular images by a Structure-from-Motion approach into a local, robot-centric, multi-resolution elevation map of the overflown terrain, which fuses depth measurements according to their lateral surface resolution (pixel-footprint) in a probabilistic framework based on the concept of dynamic Level of Detail. Map aggregation only requires depth maps and the associated poses, which are obtained from an on-board Visual Odometry algorithm. An efficient landing site detection method then exploits the features of the underlying multi-resolution map to detect safe landing sites based on the slope, roughness, and quality of the reconstructed terrain surface. The evaluation of the performance of the mapping and landing site detection modules are analyzed independently and jointly in simulated and realworld experiments in order to establish the efficacy of the proposed approach.

Brockers, Roland↗

Autonomous Safe Landing Site Detection for a FutureMars Science Helicopter

Future Mars Rotorcrafts require advanced navigation capabilities to enable all terrain access for science investigations with long distance flights that are executed fully autonomously. A critical component is the ability to safely land in hazardous terrain as part of a mission, or triggered by an emergency situation. In this paper, we present an advanced navigation system for continuous on-board terrain reconstruction for the purpose of hazard-free landing site detection for the autonomous navigation of a Mars Science Helicopter - a JPL research concept that investigates the feasibility of flying a multi-kilogram science payload at various Mars science locations, with flight ranges of multiple kilometers per flight. Our approach builds on a visionbased perception system that incorporates an on-board visualinertial state estimator augmented by a laser altimeter (range- VIO), and a structure-from-motion 3D reconstruction approach that uses a single, downward-looking camera to provide dense depth measurements while the vehicle is in motion. Depth measurements are accumulated in a local, robot-centric, multiresolution elevation map that is analyzed by a landing site detector to extract safe landing areas below the rotorcraft, based on a heuristic that includes slope, roughness and the presence of landing hazards. Detected landing sites are prioritized by an on-board autonomy engine that either selects suitable landing sites for immediate landing maneuvers, or can explore a terrain location as part of a mission in order to find a best landing site in a pre-planned area. We demonstrate and evaluate our approach on simulated data and data acquired with a surrogate unmanned aerial system (UAS) executing flights over relevant terrain.

Tzanetos, Teddy↗

Performance of the Moving Voxel Image Reconstruction (MVIR) Method in the Fixed Site Detection System (FSDS) Prototype

We have developed a dynamic image reconstruction method called MVIR (Moving Voxel Image Reconstruction) for lane detection in multilane portal monitor systems. MVIR was evaluated for use in the Fixed Site Detection System, a prototype three-lane portal monitor system for EZ-pass toll plazas. As a baseline, we compared MVIR with a static image reconstruction method in analyzing the same real and simulated data sets. Performance was judged by the distributions of image intensities for source and no-source vehicles over many trials as a function of source strength. We found that MVIR produced significantly better results in all cases. The performance difference was greatest at low count rates, where source/no-source distributions were well separated with the MVIR method, allowing reliable source vehicle identification with a low probability of false positive identifications. Static reconstruction of the same data produced overlapping distributions that made source vehicle identification unreliable. The performance of the static method was acceptable at high count rates. Both algorithms reliably identified two strong sources passing through at nearly the same time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A C. elegans -Based Foam for Rapid On-Site Detection of Residual Live Virus

In the response to and recovery from a critical homeland security event involving deliberate or accidental release of biological agents, initial decontamination efforts are necessarily followed by tests for the presence of residual live virus or bacteria. Such 'clearance sampling' should be rapid and accurate, to inform decision makers as they take appropriate action to ensure the safety of the public and of operational personnel. However, the current protocol for clearance sampling is extremely time-intensive and costly, and requires significant amounts of laboratory space and capacity. Detection of residual live virus is particularly problematic and time-consuming, as it requires evaluation of replication potential within a eukaryotic host such as chicken embryos. The intention of this project was to develop a new method for clearance sampling, by leveraging Sandia's expertise in the biological and material sciences in order to create a C. elegans -based foam that could be applied directly to the entire contaminated area for quick and accurate detection of any and all residual live virus by means of a fluorescent signal. Such a novel technology for rapid, on-site detection of live virus would greatly interest the DHS, DoD, and EPA, and hold broad commercial potential, especially with regard to the transportation industry.

59 BASIC BIOLOGICAL SCIENCES↗

Optimizing Terrain Mapping and Landing Site Detection for Autonomous UAVs

The next generation of Mars rotorcrafts requires on-board autonomous hazard avoidance landing. To this end, this work proposes a system that performs continuous multi- resolution height map reconstruction and safe landing spot detection. Structure-from-Motion measurements are aggregated in a pyramid structure using a novel Optimal Mixture of Gaus- sians formulation that provides a comprehensive uncertainty model. Our multiresolution pyramid is built more efficiently and accurately than past work by decoupling pyramid filling from the measurement updates of different resolutions.To detect the safest landing location, after an optimized hazard segmentation, we use a mean shift algorithm on multiple distance transform peaks to account for terrain roughness and uncertainty. The benefits of our contributions are evaluated on real and synthetic flight data.

Brockers, Roland↗

Mineralogy, Abundance, and Hydration State of Sulfates and Chlorides at the Mars Pathfinder Landing Site

Detection of elevated concentrations of S and Cl at the landing sites of Viking 1 and 2 [1], and Mars Pathfinder (MP) [2-5] reveals the presence of sulfates and chlorides in soil and rock samples [1-10]. These data are consistent with the findings of Ca sulfates and NaCl in Martian meteorites [11,12], and with Earth-based spectroscopic observations [13,14] tentatively indicating the presence of sulfates on Mars. Although the correlation of S and Mg in Viking and MP samples could reveal the occurrence of Mg sulfate [1-10], the mineralogy of sulfates and chlorides remains unclear.

Zolotov, M. Y.↗

Source Term Estimation of Radioxenon Released from the Fukushima Dai-ichi Nuclear Reactors Using Measured Air Concentrations and Atmospheric Transport Modeling

Systems designed to monitor airborne radionuclides released from underground nuclear explosions detected radioactive fallout from the Fukushima Daiichi nuclear accident in March 2011. Atmospheric transport modeling (ATM) of plumes of noble gases and particulates were performed soon after the accident to determine plausible detection locations of any radioactive releases to the atmosphere. We combine sampling data from multiple International Modeling System (IMS) locations in a new way to estimate the magnitude and time sequence of the releases. Dilution factors from the modeled plume at five different detection locations were combined with 57 atmospheric concentration measurements of 133-Xe taken from March 18 to March 23 to estimate the source term. This approach estimates that 59% of the 1.24×1019 Bq of 133-Xe present in the reactors at the time of the earthquake was released to the atmosphere over a three day period. Source term estimates from combinations of detection sites have lower spread than estimates based on measurements at single detection sites. Sensitivity cases based on data from four or more detection locations bound the source term between 35% and 255% of available xenon inventory.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A Radiotracer Assessment of Pulsatile Flow

Positron Emission Particle Tracking (PEPT) is a Lagrangian measurement technique used to examine flow behavior. In PEPT, tracer particles are labeled with a positron-emitting radionuclide. The emitted positron annihilates with a nearby electron, producing two back-to-back gamma rays of 511 keV. These gamma rays are detected using a Positron Emission Tomography (PET) scanner. The PET scanner monitors the detection sites and corresponding time in time steps on the order of milliseconds. The detection sites of the two gamma rays are connected via lines of response (LORs), and with multiple LORs a particle location is determined. Many methods have been explored in the past to track tracer particles in the field of view (FOV) of the scanner. The initial method for single particle PEPT was established by Parker et al. This method was refined to track multiple particles by Yang et al. Another method was developed by Bickell, et al based on the 'line density' of LORs in the scanner's FOV. This method was modified by Wiggins, et al to locate and track multiple particles in the FOV without a priori information about the particles. Pulsatile flow is seen in human blood flow and hydraulic and mechanical systems. The pressure gradient of the flow has been studied in an elastic tube with varying viscosity and stiffness by Anssari-Benam et al. Velocity and Reynold stresses have been examined in a rigid tube by Adamec et al. In this research, a new pulsatile flow system is constructed to analyze 3D velocity fields in Lagrangian specifications with capability of conversion to Eulerian specification. The absolute pressure across the test section is also examined. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Portable Analytical Systems for On-Site Diagnosis of Exposure to Pesticides and Nerve Agents

In this chapter, we summarize recent work in our laboratory on the development of sensitive portable analytical systems for use in on-site detection of exposure to organophosphate (OP) pesticides and chemical nerve agents. These systems are based on various nanomaterials functioning as transducers; recognition agents or labels and various elelectrochemical/immunoassay techniques. The studied nanomaterials included functionalized carbon nanotubes (CNT), zirconia nanoparticles (NPs) and quantum dots (QDs). Three biomarkers e.g. the free OPs, metabolites of OPs and protein-OP adducts in biological matrices have been employed for biomonitoring of OP exposure with our developed system. It has been found that the nanomaterial-based portable analytical systems have high sensitivity for the detection of the biomarkers, which suggest that these technologies offer great promise for the rapid and on-site detection and evaluation of OP exposure.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Field Evaluation of an External and Neutrally Buoyant Acoustic Transmitter for Juvenile Salmon: Implications for Estimating Hydroturbine Passage Survival

Turbine-passed fish are exposed to rapid decreases in pressure which can cause barotrauma. The presence of an implanted telemetry tag increases the likelihood of injury or death from exposure to pressure changes, thus potentially biasing studies evaluating survival of turbine-passed fish. Therefore, a neutrally buoyant externally attached tag was developed to eliminate this bias in turbine passage studies. This new tag was designed not to add excess mass in water or take up space in the coelom, having an effective tag burden of zero with the goal of reducing pressure related biases to turbine survival studies. To determine if this new tag affects fish performance or susceptibility to predation, it was evaluated in the field relative to internally implanted acoustic transmitters (JSATS; Juvenile Salmon Acoustic Telemetry System) used widely for survival studies of juvenile salmonids. Survival and travel time through the study reach was compared between fish with either tag type in an area of high predation in the Snake and Columbia rivers, Washington. An additional group of fish affixed with neutrally-buoyant dummy external tags were implanted with passive integrated transponder (PIT) tags and recovered further downstream to assess external tag retention and injury. There were no significant differences in survival to the first detection site, 12 river kilometers (rkm) downstream of release. Travel times were also similar between groups. Conversely, externally-tagged fish had reduced survival (or elevated tag loss) to the second detection site, 65 rkm downstream. In addition, the retention study revealed that tag loss was first observed in fish recaptured approximately 9 days after release. Results suggest that this new tag may be viable for short term (<8 days) single-dam turbine-passage studies and under these situations, may alleviate the turbine passage-related bias encountered when using internal tags, however further research is needed to confirm this.

58 GEOSCIENCES↗

Advanced Collision Detection and Site Monitoring for Avian and Bat Species for Offshore Wind Energy (Final Technical Report)

This final technical report summarizes the outcomes from a project that aimed to design, build, and test a persistent and autonomous monitoring system for avian and bat collisions with offshore wind turbines blades and structures. The system comprises four primary sensor modules: 1) on-blade sensor modules for collision detection and dual-vision image capture on each blade with both visible light and near-infrared imagers; 2) additional on-blade collision sensors mounted further from the root; 3) a nacelle-mounted unit including a 360º camera and ultrasonic microphone array; and, 4) an on-blade, high-performance infrared camera module. Primary targeted outcomes were high sensitivity for the detection of blade strikes from bats and small birds, and automatically captured visual confirmation of the striking object; these features are critical for monitoring offshore wind turbine installations, where ground-based methods are not viable. In addition, local recording will provide a long-term sensor recording database. Following laboratory validation, field testing was conducted on an operational wind turbine in collaboration with the National Wind Technology Center at the NREL Flatirons campus over two planned field tests.

17 WIND ENERGY↗