Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shot noise limited”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Shot noise limited detection of OH using the technique of laser induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluorescence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the shot-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Shot noise limited detection of OH using the technique of laser-induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Shot noise limits to sensitivity of optical interferometry

By arguing that the limiting noise is the photoelectron shot noise, we show that the sensitivity of image synthesis by an ideal optical interferometer is independent of the details of beam-splitting and recombination. The signal-to-noise ratio of the synthesized image is proportional to the square root of the total number of photoelectrons detected by the entire array. For non-ideal interferometers, which are forced to employ a closure-phase method of indirect inference of the visibility data, essentially the same result holds for strong sources, but at weak light levels beam-splitting degrades sensitivity.

Prasad, Sudhakar↗

Measuring electrically charged particle fluxes in space using a fiber optic loop sensor

The purpose of this program was to demonstrate the potential of a fiber optic loop sensor for the measurement of electrically charged particle fluxes in space. The key elements of the sensor are a multiple turn loop of low birefringence, single mode fiber, with a laser diode light source, and a low noise optical receiver. The optical receiver is designed to be shot noise limited, with this being the limiting sensitivity factor for the sensor. The sensing element is the fiber optic loop. Under a magnetic field from an electric current flowing along the axis of the loop, there is a non-vanishing line integral along the fiber optic loop. This causes a net birefringence producing two states of polarization whose phase difference is correlated to magnetic field strength and thus, current in the optical receiver electronic processing. The objectives in this program were to develop a prototype laser diode powered fiber optic sensor. The performance specification of a minimum detectable current density of 1 (mu)amp/sq m-(radical)Hz, should be at the shot noise limit of the detection electronics. OPTRA has successfully built and tested a 3.2 m diameter loop with 137 turns of low birefringence optical fiber and achieved a minimum detectable current density of 5.4 x 10(exp-5) amps/(radical)Hz. If laboratory space considerations were not an issue, with the length of optical fiber available to us, we would have achieved a minimum detectable current density of 4 x 10(exp -7) amps/(radical)Hz.

Source record↗

Sub-Shot Noise Power Source for Microelectronics

Low-current, high-impedance microelectronic devices can be affected by electric current shot noise more than they are affected by Nyquist noise, even at room temperature. An approach to implementing a sub-shot noise current source for powering such devices is based on direct conversion of amplitude-squeezed light to photocurrent. The phenomenon of optical squeezing allows for the optical measurements below the fundamental shot noise limit, which would be impossible in the domain of classical optics. This becomes possible by affecting the statistical properties of photons in an optical mode, which can be considered as a case of information encoding. Once encoded, the information describing the photon (or any other elementary excitations) statistics can be also transmitted. In fact, it is such information transduction from optics to an electronics circuit, via photoelectric effect, that has allowed the observation of the optical squeezing. It is very difficult, if not technically impossible, to directly measure the statistical distribution of optical photons except at extremely low light level. The photoelectric current, on the other hand, can be easily analyzed using RF spectrum analyzers. Once it was observed that the photocurrent noise generated by a tested light source in question is below the shot noise limit (e.g. produced by a coherent light beam), it was concluded that the light source in question possess the property of amplitude squeezing. The main novelty of this technology is to turn this well-known information transduction approach around. Instead of studying the statistical property of an optical mode by measuring the photoelectron statistics, an amplitude-squeezed light source and a high-efficiency linear photodiode are used to generate photocurrent with sub-Poissonian electron statistics. By powering microelectronic devices with this current source, their performance can be improved, especially their noise parameters. Therefore, a room-temperature sub-shot noise current source can be built that will be beneficial for a very broad range of low-power, low-noise electronic instruments and applications, both cryogenic and room-temperature. Taking advantage of recent demonstrations of the squeezed light sources based on optical micro-disks, this sub-shot noise current source can be made compatible with the size/power requirements specific of the electronic devices it will support.

Strekalov, Dmitry V.↗

Active frequency stabilization of a 1.062-micron, Nd:GGG, diode-laser-pumped nonplanar ring oscillator to less than 3 Hz of relative linewidth

Results are presented on the frequency stabilization of two diode-laser-pumped ring lasers that are independently locked to the same high-finesse interferometer. The relative frequency stability is measured by locking the lasers one free spectral range apart and observing the heterodyne beat note. The resultant beat note width of 2.9 Hz is consistent with the theoretical system noise-limited linewidth and is approximately 20 times that expected for shot-noise-limited performance.

Day, T.↗

A new Fabry-Perot spectrometer for observations of diffuse near-infrared line emission

We describe a new Fabry-Perot spectrometer that is optimized for the detection of extended, low-surface-brightness line emission from 1.4 to 2.4 microns. The instrument combines high throughput and high sensitivity, yet limits the background radiation falling on the detector. The instrument has a single 20 sec - 200 sec beam and a resolving power lambda/delta(lambda) approximately 2500. The system is background shot-noise limited in the K window and limited by a combination of read noise, dark-current shot noise, and fluctuations in the OH airglow lines in the H window. We present sample data of some of the lowest-surface-brightness H2 line emission in the near infrared obtained to date.

Luhman, M. L.↗

Application of Twin Beams in Mach-Zehnder Interferometer

Using the twin beams generated from parametric amplifier to drive the two port of a Mach-Zehnder interferometer, it is shown that the minimum detectable optical phase shift can be largly reduced to the Heisenberg limit(1/n) which is far below the Shot Noise Limit(1/square root of n) the large gain limit. The dependence of the minimum detectable phase shift on parametric gain and the inefficient photodetectors has been discussed.

Zhang, J. X.↗

Parameter Estimation with Entangled Photons Produced by Parametric Down-Conversion

We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate "Heisenberg" limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.

Cable, Hugo↗

Intensity noise in diode-pumped single-frequency Nd:YAG lasers and its control by electronic feedback

The power spectrum of the relative intensity noise (RIN) of single-frequency diode-pumped Nd:YAG lasers is observed to be shot-noise limited at frequencies above 20 MHz for a photocurrent of up to 4.4 mA. Relaxation oscillations result in noise 60-70 dB above shot noise at a few hundred kHz. These relaxation oscillations have been suppressed using electronic feedback.

Kane, Thomas J.↗

Performance and optimization of a combustion interface for isotope ratio monitoring gas chromatography/mass spectrometry

Conditions and systems for on-line combustion of effluents from capillary gas chromatographic columns and for removal of water vapor from product streams were tested. Organic carbon in gas chromatographic peaks 15 s wide and containing up to 30 nanomoles of carbon was quantitatively converted to CO2 by tubular combustion reactors, 200 x 0.5 mm, packed with CuO or NiO. No auxiliary source of O2 was required because oxygen was supplied by metal oxides. Spontaneous degradation of CuO limited the life of CuO reactors at T > 850 degrees C. Since NiO does not spontaneously degrade, its use might be favored, but Ni-bound carbon phases form and lead to inaccurate isotopic results at T < 1050 degrees C if gas-phase O2 is not added. For all compounds tested except CH4, equivalent isotopic results are provided by CuO at 850 degrees C, NiO + O2 (gas-phase mole fraction, 10(-3)) at 1050 degrees C and NiO at 1150 degrees C. The combustion interface did not contribute additional analytical uncertainty, thus observed standard deviations of 13C/12C ratios were within a factor of 2 of shot-noise limits. For combustion and isotopic analyses of CH4, in which quantitative combustion required T approximately 950 degrees C, NiO-based systems are preferred, and precision is approximately 2 times lower than that observed for other analytes. Water must be removed from the gas stream transmitted to the mass spectrometer or else protonation of CO2 will lead to inaccuracy in isotopic analyses. Although thresholds for this effect vary between mass spectrometers, differential permeation of H2O through Nafion tubing was effective in both cases tested, but the required length of the Nafion membrane was 4 times greater for the more sensitive mass spectrometer.

NASA Discipline Exobiology↗

Real Time Quantitative 3-D Imaging of Diffusion Flame Species

A low-gravity environment, in space or ground-based facilities such as drop towers, provides a unique setting for study of combustion mechanisms. Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as better characterization of dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Even the use of so-called 'limiting cases' or the construction of 1-D or 2-D models and experiments fail to make the analysis of combustion simultaneously simple and accurate. Ideally, to bridge the gap between chemistry and fluid mechanics in microgravity combustion, species concentrations and temperature profiles are needed throughout the flame. However, restrictions associated with performing measurements in reduced gravity, especially size and weight considerations, have generally limited microgravity combustion studies to the capture of flame emissions on film or video laser Schlieren imaging and (intrusive) temperature measurements using thermocouples. Given the development of detailed theoretical models, more sophisticated studies are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion processes as well as provide accurate feedback to improve the predictive capabilities of the computational models. While there have been a myriad of fluid mechanical visualization studies in microgravity combustion, little experimental work has been completed to obtain reactant and product concentrations within a microgravity flame. This is largely due to the fact that traditional sampling methods (quenching microprobes using GC and/or mass spec analysis) are too heavy, slow, and cumbersome for microgravity experiments. Non-intrusive optical spectroscopic techniques have - up until now - also required excessively bulky, power hungry equipment. However, with the advent of near-IR diode lasers, the possibility now exists to obtain reactant and product concentrations and temperatures non-intrusively in microgravity combustion studies. Over the past ten years, Southwest Sciences has focused its research on the high sensitivity, quantitative detection of gas phase species using diode lasers. Our research approach combines three innovations in an experimental system resulting in a new capability for nonintrusive measurement of major combustion species. FM spectroscopy or high frequency Wavelength Modulation Spectroscopy (WMS) have recently been applied to sensitive absorption measurements at Southwest Sciences and in other laboratories using GaAlAs or InGaAsP diode lasers in the visible or near-infrared as well as lead-salt lasers in the mid-infrared spectral region. Because these lasers exhibit essentially no source noise at the high detection frequencies employed with this technique, the achievement of sensitivity approaching the detector shot noise limit is possible.

Kane, Daniel J.↗

Self-scanned Digicon - A digital image tube for astronomical spectroscopy

We have successfully fabricated, tested, and operated a digital image tube consisting of a magnetically focused image intensifier tube in which a self-scanned linear array of 1024 silicon photodiodes operating in the EBS mode serves as the photoelectron image detector, amplifier, and intermediate image storage device. Integral on-chip MOS shift registers driven by an external clock sequentially interrogate the photodiodes through MOS FET multiplex switch arrays. Each output frame is a sequence of 256 analog pulses on each of four video lines. Laboratory and observing tests show that the output signal is photoelectron shot noise limited over at least a range of 1-100,000 detected photoelectrons per picture element, indicating that single photon detection is achieved. High-resolution astronomical spectroscopy has been carried out in the coude spectrograph of the 2.7-m telescope at McDonald Observatory. Examples are shown.

Tull, R. G.↗

Source self-mixing in the detection of extended incoherent sources

We consider the self-beating of incoherent light from an extended source at a wideband photomixer. The intermediate frequency mean squared current is found to be proportional to the product of the direct detected source power and the power within the IF bandpass about the optical frequency and within the heterodyne field of view. Thus the ratio of the heterodyne signal to self-beating power is proportional to the ratio of local oscillator power to direct detected power. This ratio is usually large for systems employing efficient local oscillators that generate shot-noise-limited operation. In less efficient systems, such as those employing tunable diode lasers, the effects of self-mixing may be significant.

Cohen, S. C.↗

A fully automated digitally controlled 30-inch telescope

A fully automated 30-inch (75-cm) telescope has been successfully designed and constructed from a military surplus Nike-Ajax radar mount. Novel features include: closed-loop operation between mountain telescope and campus computer 30 km apart via microwave link, a TV-type sensor which is photon shot-noise limited, a special lightweight primary mirror, and a stepping motor drive capable of slewing and settling one degree in one second or a radian in fifteen seconds.

Colgate, S. A.↗

Experimental remote sensing of subsurface temperature in natural ocean water

The first successful depth-resolved remote sensing measurements of subsurface ocean water temperature were obtained by spectral analysis of the 3400 per cm O-H stretching Raman band of liquid water. Raman spectral data were obtained from a research vessel at various depths from the surface to 10 meters below the surface in a tidal estuary. The temperature inferred from the spectra was consistent with ground truth temperature to within the shot noise limited accuracy of plus or minus 2 C. The performance of a future fully developed airborne laser Raman water temperature measurement system is estimated on the basis of these first tests.

Leonard, D. A.↗

The evaluation of a HgCdTe photomixer with a Tunable Diode Laser (TDL) and the evaluation of TDL's as a local oscillator in a heterodyne detection system

Heterodyne systems would be much more versatile if a broadly tunable laser, such as a semiconductor diode laser (TDL), could be used as the local oscillator (LO). Previous studies have shown that while a TDL can be used as an LO, the TDL lack sufficient power to cause the signal-to-noise ratio to be shot noise limited. The heterodyne system with a HgCdTe photodiode as the LO was characterized and the beat frequency response of the heterodyne systems was mapped out.

Harward, C. N.↗

Texas Instruments /TI/ 800 x 800 charge-coupled device /CCD/ image sensor

Very-large area high-performance CCD image sensors with 800 x 800 pixel format have been successfully fabricated and operated on the basis of a three-level polysilicon gate technology. They are thinned to 8 microns over the entire 12.2 x 12.2 mm active area, and are used in the rear illumination mode. The light transfer characteristic has a gamma value of 1.000 + or - 0.002 over most of the dynamic range. Analysis of the noise behavior shows that the device SNR is shot-noise-limited over most of the dynamic range. Simple on-chip signal processing can be performed using an integration well to noiselessly collect signal charge from multiple pixels prior to reading out the charge. A UV-sensitive phosphor has been applied to the chip, yielding a device capable of imaging at wavelengths from the vacuum UV to the near IR.

Blouke, M. M.↗