Engineering PapersSearch

SEARCH · Engineering Papers

Results for “short circuit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Short circuit protection for a power distribution system

Sensing circuit detects when the output from a matrix is present and when it should be present. The circuit provides short circuit protection for a power distribution system where the selection of the driven load is accomplished by digital logic.

Owen, J. R., III

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]

Improved internal short circuit models for thermal runaway simulations in lithium-ion batteries

Thermal runaway (TR) modeling is one of the primary tools that can be used to overcome challenges associated with lithium-ion battery (LIB) safety. Among all LIB accidents that have occurred over the past decade, Internal Short Circuit (ISC) remains the most common trigger mechanism. Many available models in the literature either use a simplified approach to simulate ISC or completely ignore its contribution. The aim of this study is to understand the nature of the heat released for different types of ISC scenarios, including aluminum-anode, anode–cathode, and copper-cathode ISC. We study ISC behavior using a coupled electrochemical–thermal model with an integrated TR chemical kinetics solver built in the COMSOL Multiphysics framework. The time duration of heat release and the magnitude of the peak ISC current are studied as functions of parameters such as the size of the penetrating filament and the capacity of the cell. The numerical results are used to build an empirical model validated against the published experimental TR propagation data. Our model can be successfully used as a viable low-cost substitute in lower order (lumped) TR simulations to enable TR prevention and mitigation.

Singh, Bakhshish Preet (ORCID:0000000264751992)

Pressure-Tolerant 3D Anodes Enable Short-Circuit Prevention and Low Heat Generation in Argyrodite Solid-State Batteries

Solid-state batteries (SSBs) offer a safer, higher-energy-density alternative to lithium-ion batteries, yet commercialization is hindered by incompatibility with lithium metal. Here, to overcome these challenges, we developed a cost-effective, commercially available prelithiated micro carbon fiber framework (Li-Cf) anode featuring a high-pressure-tolerance, for use with argyrodite solid-state electrolytes (SSEs). This 3D structure accommodates uniform lithium deposition, simplifies cell assembly under elevated pressure, inhibits dendrite growth toward SSEs, reduces heat generation, and enhances overall compatibility. Notably, our architecture enables the cell to tolerate pressures up to 400 MPa without short-circuiting during assembly. Meanwhile, the 3D framework serves as a preferential pathway for lithium deposition, thereby reducing lithium growth toward the SSEs and mitigating the risk of dendrite formation in SSEs. Operando calorimetry and distribution of relaxation times analysis reveal that lithium morphology degradation at the interface with the SSEs is a key failure mechanism in lithium metal argyrodite SSBs, leading to increased diffusion resistance and heat generation. In contrast, the Li-Cf anode mitigates these issues by reducing both heat flux and charge transfer resistance. Full cells with LiNi 0.8 Co 0.1 Mn 0.1 O 2 /Li 6 PS 5 Cl/Li-Cf retain ~79% capacity after 600 cycles, demonstrating significantly improved cycling stability and strong potential for practical energy storage applications.

25 ENERGY STORAGE

A Parametric Reduced-Order Model for Inverter Short-Circuit Response in Protection Studies

This paper presents a reduced-order model (ROM) for grid-following (GFL) inverters that reproduces inverter fault current trajectories, including sub transients, transient, and steady-state phases, across a range of fault types, locations, and pre-fault operating points. . The proposed model is developed by: Constructing the positive- and negative-sequence current with parameterization fitted by large data training and fitting Validating using EMT simulation against EMT full model and demonstrating the ROM's capability to capture fault current magnitude, phase angle, and oscillatory transients. Building a standard EMT simulation platform library component for easy configuration and application.

24 POWER TRANSMISSION AND DISTRIBUTION

Inter-cofactor protein remodeling rewires short-circuited transmembrane electron transfer

Intraprotein electron transfer (ET) requires explicit local control of the environment of cofactors to influence their intermolecular distances, relative orientations, and redox properties. Efficient, longer-range ET often utilizes molecular orbitals of aromatic residues present in the intervening space. Here, revitalization of a vestigial ET pathway in the bacterial photosynthetic reaction center is achieved by scanning with tryptophans to uncover markedly improved routes of electron conduction in a key stabilizing step spanning 15 Å between tetrapyrrole and quinone cofactors. This ET event is maximally enhanced by pairing one or more tryptophans with a threonine to influence quinone binding and/or redox potential. Synergistic effects of these substitutions increase the yield of that ET step to ~95%. Joining these substitutions with mutant residues that improve initial ET steps dramatically enhances transmembrane charge separation via this redesigned version of a pathway that is quantitatively inactive in the native protein-cofactor complex.

Biophysical chemistry