Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electron Accelerator Shielding Design of KIPT Neutron Source Facility

The Argonne National Laboratory of the United States and the Kharkov Institute of Physics and Technology of the Ukraine have been collaborating on the design, development and construction of a neutron source facility at Kharkov Institute of Physics and Technology utilizing an electron-accelerator-driven subcritical assembly. The electron beam power is 100 kW using 100-MeV electrons. The facility was designed to perform basic and applied nuclear research, produce medical isotopes, and train nuclear specialists. The biological shield of the accelerator building was designed to reduce the biological dose to less than 5.0e-03 mSv/h during operation. The main source of the biological dose for the accelerator building is the photons and neutrons generated from different interactions of leaked electrons from the electron gun and the accelerator sections with the surrounding components and materials. The Monte Carlo N-particle extended code (MCNPX) was used for the shielding calculations because of its capability to perform electron-, photon-, and neutron-coupled transport simulations. The photon dose was tallied using the MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is very small, similar to 0.01 neutron for 100-MeV electron and even smaller for lower-energy electrons. This causes difficulties for the Monte Carlo analyses and consumes tremendous computation resources for tallying the neutron dose outside the shield boundary with an acceptable accuracy. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were utilized for this study. The generated neutrons were banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron dose. The weight windows variance reduction technique was also utilized for both neutron and photon dose calculations. Two shielding materials, heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total dose outside the shield boundary less than 5.0e-03 mSv/h during operation. The shield configuration and parameters of the accelerator building were determined and are presented in this paper. Copyright (C) 2016, Published by Elsevier Korea LLC on behalf of Korean Nuclear Society.

43 PARTICLE ACCELERATORS↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Shield Design for 50 kW Three-Phase Wireless Charging System

In this paper, magnetic field emissions (MFE) from a 50 kW bipolar coil-based three-phase wireless charging system (WCS) is investigated. Then, a shield design is proposed to suppress the MFE below the safety limit identified by the International Commission of Non-Ionized Radiation Protection (ICNIRP) guidelines. Bipolar coil-based three-phase (3φ) WCSs provide extremely high power-density; therefore, the 3φ WCSs are highly promising for high-power fast-wireless-charging of the electric vehicles. For the high-power EV application, it is a critical challenge to design a shield to suppress the MFE below the safety limit. The traditional aluminum shield is found ineffective for the bipolar 3φ-WCS. The proposed shield is designed with high-permeability magnetic material, i.e. ferrite, nanocrystalline material, etc. The proposed shield is simulated in finite element analysis (FEA) and the FEA results show that the proposed magnetic shield effectively suppresses the magnetic field emission below the ICNIRP limit. The generalized design of the proposed shield can be used for even higher power bipolar coil based WCSs.

Mohammad, Mostak↗

Optimal shielding design for minimum materials cost or mass

The mathematical underpinnings of cost optimal radiation shielding designs based on an extension of optimal control theory are presented, a heuristic algorithm to iteratively solve the resulting optimal design equations is suggested, and computational results for a simple test case are discussed. A typical radiation shielding design problem can have infinitely many solutions, all satisfying the problem's specified set of radiation attenuation requirements. Each such design has its own total materials cost. For a design to be optimal, no admissible change in its deployment of shielding materials can result in a lower cost. This applies in particular to very small changes, which can be restated using the calculus of variations as the Euler-Lagrange equations. Furthermore, the associated Hamiltonian function and application of Pontryagin's theorem lead to conditions for a shield to be optimal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-206-17: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semiautomated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-P-53: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semi-automated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

60 APPLIED LIFE SCIENCES↗

The New Modular High-Energy X-ray Source Facility Shielding Design

Several new research facilities will soon be constructed as part of the creation of a new engineering complex on the campus of the University of Tennessee, Knoxville (UTK). As part of this renovation, a state of the art nuclear engineering building will be constructed. This building will include a critical experiment facility, a graphite pile, and a modular high-energy X-ray source (or accelerator facility). The proximity of these new facilities to UTK's football stadium brings heightened attention to their design and safety. An important aspect of this specific design is that shielding is required to contain the new radiation sources. The work completed will reflect the specific project planning and novel two-story facility design of the modular high-energy X-ray source. It will also provide a detailed shielding and dose analysis of the facility as a whole. The end design places an accelerator into a well-shielded room; it will then direct the x-ray beam through a collimating hole in the shielding wall into the next room. The x-ray beam is to be used as a part of a materials irradiation and imaging laboratory in the adjoining room. The design satisfies all regulatory requirements, and it will serve as the preliminary facility layout design and shielding analysis for a novel two-story modular high energy X-ray source facility. The dose rates calculated by the Monte Carlo models using the NCRP shielding thickness values are well below the dose limitations set by the State of Tennessee, which leaves room for optimization. Further work could be done to complete the optimization by reducing the shielding thickness while maintaining a dose below dose regulations by using a less conservative method for calculating the initial thicknesses. (authors)

43 PARTICLE ACCELERATORS↗

Electromagnetic simulation of helicon plasma antennas for their electrostatic shield design

A detailed electromagnetic parametric analysis of the helicon antenna (half Nagoya type) is shown at 13.56 MHz using a CST Microwave Studio 2012. The antenna is used to excite plasma inside a dielectric cylinder similar to a commercial reactor. Instead of focusing on the plasma state, the authors focus on the penetration and the three dimensional distribution of electric fields through the dielectric wall. Our aim is to reduce capacitive coupling which produces unwanted longitudinal and radial electric fields. Comparison of the helicon antenna electromagnetic performance under diverse boundary conditions shows that one is allowed to use vacuum simulations without plasma present in the cylinder, or approximate the plasma as a column of gyrotropic material with a tensor dielectric permittivity and with a sheath of a few millimeters in order to qualitatively predict the electric field distribution, thus avoiding a full plasma simulation. This way the analysis of the full problem is much faster and allows an optimal shield design. A detailed study of various shields shows that one can reduce the radial and axial fields by more than 1 order of magnitude compared to the unshielded antenna, while the azimuthal field is reduced only by a factor of 2. Optimal shield design in terms of pitch and spacing of openings is determined. Finally, an experimental proof of concept of the effect of shielding on reduced wall sputtering is provided, by monitoring the roughness created during oxygen plasma etching of an organic polymer.

42 ENGINEERING↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

25 ENERGY STORAGE↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

Zhang, Bo↗

Observations Regarding Face Shield Designs Using Commonly Available Materials

A Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated design options for face shields constructed from commonly available materials (CAMs). This study is not focused on face shields for medical applications, and as such, has excluded labeling and flammability considerations suggested by the FDA. Design options for face shields were analyzed with subject matter expert input considering the design's effectiveness (seal around face), reusability (compatibility with solvents, degree of inertness), producibility (ability to obtain materials, build time), cost, and comfort (fit around head, contact surface interface). Observations for the design of face shields using CAMS are provided here.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-474: Improvements to Intra-Oral Shield Design for Electron Beam Treatments: Use of Multi-Layered Metal Foils

Purpose: Intraoral electron shields used in radiotherapy are designed to minimize radiation exposure to non-treatment tissue. Sites where shields are used include but are not limited to, the treatment of lips, cheeks and ears whilst shielding the underlying oral cavity, tongue, gingival or temporal region. However their use produces an enhancement in dose on the beam side caused by an increase in electron backscatter radiation. This work designs a new shield incorporating copper, aluminium and wax in a step down filter arrangement to minimise backscatter whilst minimizing overall shield thickness. Methods: For electron beams ranging from 6 MeV to 10 MeV, shields of varying designs and thicknesses were assessed to determine the thinnest shield design that could be produced whilst minimising backscattered radiation to a clinically acceptable level. This was performed with conventional lead and wax shields as well as varying quantities of aluminium and copper foils. Results: From tested shield designs, a new shield design of 4 mm lead, 0.6 mm copper, 1.0 mm aluminium and 1.5 mm wax (3.1 mm added filtration, 7.1 mm total thickness) provided a clinically acceptable (no greater than 110% dose) backscatter and transmission reduction and matched a standard 4.5 mm lead and 10 mm wax (total thickness 14.5 mm) electron shield. Dose enhancement values of no more than 10 % were measured utilising this shield design with a 50 % reduction in shield thickness. Conclusion: The thinner layered shield reduced backscattered radiation dose to less than 10% enhancement for beam energies on 10 MeV and less and will allow easier patient set up. The thinner shields are tolerated better by patients when mucosal reactions occur as they place less physical pressure on these sites during treatment due to their smaller size and thickness.

60 APPLIED LIFE SCIENCES↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference [1]. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year. This technical note presents the method used to identify these potential high beam loss locations, evaluate the potential radiation risk these losses create outside the enclosure shield and the design process that specifies the required local radiation shielding needed to reduce this risk below the maximum dose rate of the bulk shield design, listed above. If shielding can’t be adequately provided or if other fault initiated losses could occur, then the necessary engineering controls will be indicated that will limit the energy, current or duration of the beam transport that constitute this high beam loss risk.

36 MATERIALS SCIENCE↗

Verification of the prompt radiation shielding design of the ESS Accelerator (Stage 2)

The purpose of this CRADA is to perform additional analyses using MARS Monte-Carlo calculations code for verification of the prompt radiation shielding design of the ESS Accelerator. Stage 2 includes the following activities: 1.Activation assessment of the soil surrounding the wall of the ESS accelerator that maymigrate with the groundwater 2.Shielding assessment of the HVAC exhaust duct The existing ESS accelerator model (with possible minor modifications) shall be used in calculations. This work builds on the analysis originally performed under agreement CRADA FRA-2015-0302.

43 PARTICLE ACCELERATORS↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shielding Design for Prototype Generation-IV Sodium-Cooled Fast Reactor

A Prototype Generation-IV Sodium-cooled Fast Reactor (PGSFR) with 150 MWe power rating is being developed jointly by the Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL). KAERI is responsible for the overall project with the ANL contributions integrated into the KAERI activities. Shielding concept of PGSFR was developed to ensure that the safety limit on internal structural damage and working personnel received dose is not exceeded. The first part evaluated the Displacement Per Atoms (DPA) and fast neutron fluence on the structures inside the reactor vessel, such as lower grid, Upper Internal Structure (UIS), barrel, Redan, and reactor vessels. The analysis determined the thickness of shields required to satisfy the DPA and fast fluence limit. The second part of the shielding analysis evaluated the radiation dose rate above the reactor head due to the primary sodium activation inside the reactor vessel. The analysis determined the necessary thickness of reactor head and additional shield to ensure that the dose rate received by personnel working on top of the reactor is below the safety limit. The last part of the shielding analysis investigated the dose rate received by personnel working near the secondary loop. The secondary sodium is activated inside the Intermediate heat exchanger (IHX). The activated secondary sodium flows out of the reactor vessel and emits high energy photons along the way. The shielding designs both inside the reactor vessel and around the pipes of the secondary loop were investigated. The shielding concept for the PGSFR was developed to minimize radiation exposure to plant personnel and the irradiation damage of the internal structural components. The damage of the internal structural components are mainly due to the loss of the ductility by the neutron irradiation, and the activated gammas of primary and secondary sodium coolants are the major radiation sources that are required to be shielded. Thicker and denser shielding structures are favorable to reduce the radiation dose and protect personnel who work in the plant; however, which enlarges the in-vessel space to accommodate the shielding structures. Thus, in order to install the shielding structures in a reasonable reactor to satisfy the DPA or dose rate limit size, the PGSFR shielding parameters were determined from the sensitivity study, which includes the compositions of the shielding materials and dimensions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial experimental demonstration of the principles of a xenon gas shield designed to protect optical components from soft x-ray induced opacity (blanking) in high energy density experiments

The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1 , 250–300 eV). Blanking of fused silica (SiO 2 ) was measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2 . A shield test device consisting of a 30 nm silicon nitride (Si 3 N 4 ) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.

42 ENGINEERING↗

Shielding design for the LANSCE/WNR neutron flight paths - 25334

The shielding surrounding the spallation target and the neutron flight paths at the Los Alamos Neutron Science Center Weapons Neutron Research facility is simulated using a detailed MCNPX Monte Carlo model to determine neutron and γ-ray backgrounds in the experimental areas. In some cases the shielding needs to be modified depending on the requirements of planned experiments. (authors)

07 ISOTOPE AND RADIATION SOURCES↗