Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sequential Monte Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Persistent Sampling: Enhancing the Efficiency of Sequential Monte Carlo

Sequential Monte Carlo (SMC) samplers are powerful tools for Bayesian inference but suffer from high computational costs due to their reliance on large particle ensembles for accurate estimates. We introduce persistent sampling (PS), an extension of SMC that systematically retains and reuses particles from all prior iterations to construct a growing, weighted ensemble. By leveraging multiple importance sampling and resampling from a mixture of historical distributions, PS mitigates the need for excessively large particle counts, directly addressing key limitations of SMC such as particle impoverishment and mode collapse. Crucially, PS achieves this without additional likelihood evaluations-weights for persistent particles are computed using cached likelihood values. This framework not only yields more accurate posterior approximations but also produces marginal likelihood estimates with significantly lower variance, enhancing reliability in model comparison. Furthermore, the persistent ensemble enables efficient adaptation of transition kernels by leveraging a larger, decorrelated particle pool. Experiments on high-dimensional Gaussian mixtures, hierarchical models, and non-convex targets demonstrate that PS consistently outperforms standard SMC and related variants, including recycled and waste-free SMC, achieving substantial reductions in mean squared error for posterior expectations and evidence estimates, all at reduced computational cost. PS thus establishes itself as a robust, scalable, and efficient alternative for complex Bayesian inference tasks.

Karamanis, Minas↗

astroABC : An Approximate Bayesian Computation Sequential Monte Carlo sampler for cosmological parameter estimation

Given the complexity of modern cosmological parameter inference where we arefaced with non-Gaussian data and noise, correlated systematics and multi-probecorrelated data sets, the Approximate Bayesian Computation (ABC) method is apromising alternative to traditional Markov Chain Monte Carlo approaches in thecase where the Likelihood is intractable or unknown. The ABC method is called"Likelihood free" as it avoids explicit evaluation of the Likelihood by using aforward model simulation of the data which can include systematics. Weintroduce astroABC, an open source ABC Sequential Monte Carlo (SMC) sampler forparameter estimation. A key challenge in astrophysics is the efficient use oflarge multi-probe datasets to constrain high dimensional, possibly correlatedparameter spaces. With this in mind astroABC allows for massive parallelizationusing MPI, a framework that handles spawning of jobs across multiple nodes. Akey new feature of astroABC is the ability to create MPI groups with differentcommunicators, one for the sampler and several others for the forward modelsimulation, which speeds up sampling time considerably. For smaller jobs thePython multiprocessing option is also available. Other key features include: aSequential Monte Carlo sampler, a method for iteratively adapting tolerancelevels, local covariance estimate using scikit-learn's KDTree, modules forspecifying optimal covariance matrix for a component-wise or multivariatenormal perturbation kernel, output and restart files are backed up everyiteration, user defined metric and simulation methods, a module for specifyingheterogeneous parameter priors including non-standard prior PDFs, a module forspecifying a constant, linear, log or exponential tolerance level,well-documented examples and sample scripts. This code is hosted online athttps://github.com/EliseJ/astroABC

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilevel sequential Monte Carlo samplers

Here, we study the approximation of expectations w.r.t. probability distributions associated to the solution of partial differential equations (PDEs); this scenario appears routinely in Bayesian inverse problems. In practice, one often has to solve the associated PDE numerically, using, for instance finite element methods and leading to a discretisation bias, with the step-size level h L . In addition, the expectation cannot be computed analytically and one often resorts to Monte Carlo methods. In the context of this problem, it is known that the introduction of the multilevel Monte Carlo (MLMC) method can reduce the amount of computational effort to estimate expectations, for a given level of error. This is achieved via a telescoping identity associated to a Monte Carlo approximation of a sequence of probability distributions with discretisation levels ${\infty}$ >h 0 >h 1 ...>h L . In many practical problems of interest, one cannot achieve an i.i.d. sampling of the associated sequence of probability distributions. A sequential Monte Carlo (SMC) version of the MLMC method is introduced to deal with this problem. In conclusion, it is shown that under appropriate assumptions, the attractive property of a reduction of the amount of computational effort to estimate expectations, for a given level of error, can be maintained within the SMC context.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multilevel Sequential Monte Carlo Samplers for Normalizing Constants

This article considers the sequential Monte Carlo (SMC) approximation of ratios of normalizing constants associated to posterior distributions which in principle rely on continuum models. Therefore, the Monte Carlo estimation error and the discrete approximation error must be balanced. A multilevel strategy is utilized to substantially reduce the cost to obtain a given error level in the approximation as compared to standard estimators. Two estimators are considered and relative variance bounds are given. The theoretical results are numerically illustrated for two Bayesian inverse problems arising from elliptic partial differential equations (PDEs). The examples involve the inversion of observations of the solution of (i) a 1-dimensional Poisson equation to infer the diffusion coefficient, and (ii) a 2-dimensional Poisson equation to infer the external forcing.

97 MATHEMATICS AND COMPUTING↗

Sequential Monte Carlo for Cut-Bayesian Posterior Computation

We propose a sequential Monte Carlo (SMC) method to efficiently and accurately compute cut-Bayesian posterior quantities of interest, variations of standard Bayesian approaches constructed primarily to account for model misspecification. We prove finite sample concentration bounds for estimators derived from the proposed method along with a linear tempering extension and apply these results to a realistic setting where a computer model is misspecified. We then illustrate the SMC method for inference in a modular chemical reactor example that includes submodels for reaction kinetics, turbulence, mass transfer, and diffusion. The samples obtained are commensurate with a direct-sampling approach that consists of running multiple Markov chains, with computational efficiency gains using the SMC method. Overall, the SMC method presented yields a novel, rigorous approach to computing with cut-Bayesian posterior distributions.

97 MATHEMATICS AND COMPUTING↗

Multilevel sequential Monte Carlo: Mean square error bounds under verifiable conditions

We consider the multilevel sequential Monte Carlo (MLSMC) method of Beskos et al. (Stoch. Proc. Appl. [to appear]). This technique is designed to approximate expectations w.r.t. probability laws associated to a discretization. For instance, in the context of inverse problems, where one discretizes the solution of a partial differential equation. The MLSMC approach is especially useful when independent, coupled sampling is not possible. Beskos et al. show that for MLSMC the computational effort to achieve a given error, can be less than independent sampling. In this article we significantly weaken the assumptions of Beskos et al., extending the proofs to non-compact state-spaces. The assumptions are based upon multiplicative drift conditions as in Kontoyiannis and Meyn (Electron. J. Probab. 10 [2005]: 61–123). The assumptions are verified for an example.

97 MATHEMATICS AND COMPUTING↗

Adaptive Sequential Monte Carlo for Multiple Changepoint Analysis

Process monitoring and control requires detection of structural changes in a data stream in real time. This paper introduces an efficient sequential Monte Carlo algorithm designed for learning unknown changepoints in continuous time. The method is intuitively simple: new changepoints for the latest window of data are proposed by conditioning only on data observed since the most recent estimated changepoint, as these observations carry most of the information about the current state of the process. The proposed method shows improved performance over the current state of the art. Another advantage of the proposed algorithm is that it can be made adaptive, varying the number of particles according to the apparent local complexity of the target changepoint probability distribution. This saves valuable computing time when changes in the changepoint distribution are negligible, and enables re-balancing of the importance weights of existing particles when a significant change in the target distribution is encountered. The plain and adaptive versions of the method are illustrated using the canonical continuous time changepoint problem of inferring the intensity of an inhomogeneous Poisson process, although the method is generally applicable to any changepoint problem. Performance is demonstrated using both conjugate and non-conjugate Bayesian models for the intensity. Lastly, appendices to the article are available online, illustrating the method on other models and applications.

97 MATHEMATICS AND COMPUTING↗

Sequential Monte Carlo sampling in hidden Markov models of nonlinear dynamical systems

We investigate the issue of which state functionals can have their uncertainty estimated efficiently in dynamical systems with uncertainty. Because of the high dimensionality and complexity of the problem, sequential Monte Carlo (SMC) methods are used. We investigate SMC methods where the proposal distribution is computed by maximum likelihood or by a linearization approach. We prove that the variance of the SMC method is bounded linearly in the number of time steps when the proposal distribution is truncated normal distribution. We also show that for a moderate large number of steps the error produced by approximation of dynamical systems linearly accumulates on the condition that the logarithm of the density function of noise is Lipschitz continuous. This finding is significant because the uncertainty in many dynamical systems, in particular, in chemical engineering systems, can be assumed to have this nature. We demonstrate our findings for a simple test case from chemical engineering. The theoretical findings provide a foundation for the parallel software SISTOS.

97 MATHEMATICS AND COMPUTING↗

Validating sequential Monte Carlo for gravitational-wave inference

Nested sampling (NS) is the preferred stochastic sampling algorithm for gravitational-wave inference for compact binary coalescences. It can handle the complex nature of the gravitational-wave likelihood surface and provides an estimate of the Bayesian model evidence. However, there is another class of algorithms that meets the same requirements, but has not been used for gravitational-wave analyses: sequential Monte Carlo (SMC), an extension of importance sampling that maps samples from an initial density to a target density via a series of intermediate densities. In this work, we validate a type of SMC algorithm, called persistent sampling (PS), for gravitational-wave inference. We consider a range of different scenarios including binary black holes and binary neutron stars and real and simulated data and show that PS produces results that are consistent with NS whilst being, on average, 2 times more efficient and 2.74 times faster. This demonstrates that PS is a viable alternative to NS that should be considered for future gravitational-wave analyses.

black hole mergers↗

Registration of 3D FMT and CT Images of Mouse via Affine Transformation using Sequential Monte Carlo

It is difficult to directly co-register the 3D FMT (Fluorescence Molecular Tomography) image of a small tumor in a mouse whose maximal diameter is only a few mm with a larger CT image of the entire animal that spans about ten cm. This paper proposes a new method to register 2D flat and 3D CT image first to facilitate the registration between small 3D FMT images and large CT images. A novel algorithm based on SMC (Sequential Monte Carlo) incorporated with least square operation for the registration between the 2D flat and 3D CT images is introduced and validated with simulated images and real images of mice. The visualization of the preliminary alignment of the 3D FMT and CT image through 2D registration shows promising results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Multilevel Monte Carlo Methods

This article reviews the application of some advanced Monte Carlo techniques in the context of multilevel Monte Carlo (MLMC). MLMC is a strategy employed to compute expectations, which can be biassed in some sense, for instance, by using the discretization of an associated probability law. The MLMC approach works with a hierarchy of biassed approximations, which become progressively more accurate and more expensive. Additionally, using a telescoping representation of the most accurate approximation, the method is able to reduce the computational cost for a given level of error versus i.i.d. sampling from this latter approximation. All of these ideas originated for cases where exact sampling from couples in the hierarchy is possible. This article considers the case where such exact sampling is not currently possible. We consider some Markov chain Monte Carlo and sequential Monte Carlo methods, which have been introduced in the literature, and we describe different strategies that facilitate the application of MLMC within these methods.

97 MATHEMATICS AND COMPUTING↗

Forward and inverse uncertainty quantification using multilevel Monte Carlo algorithms for an elliptic non-local equation

Our paper considers uncertainty quantification for an elliptic nonlocal equation. In particular, it is assumed that the parameters which define the kernel in the nonlocal operator are uncertain and a priori distributed according to a probability measure. It is shown that the induced probability measure on some quantities of interest arising from functionals of the solution to the equation with random inputs is well-defined,s as is the posterior distribution on parameters given observations. As the elliptic nonlocal equation cannot be solved approximate posteriors are constructed. The multilevel Monte Carlo (MLMC) and multilevel sequential Monte Carlo (MLSMC) sampling algorithms are used for a priori and a posteriori estimation, respectively, of quantities of interest. Furthermore, these algorithms reduce the amount of work to estimate posterior expectations, for a given level of error, relative to Monte Carlo and i.i.d. sampling from the posterior at a given level of approximation of the solution of the elliptic nonlocal equation.

97 MATHEMATICS AND COMPUTING↗

SU-F-SPS-02: Accuracy of the Small Field Dosimetry Using the Monte Carlo and Sequential Dose Calculation Algorithms of Multiplan Treatment Planning System Within and Beyond Heterogeneous Media for Cyberknife M6 Unit

Purpose: In small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation algorithm to accurately predict the dose, especially in the presence of tissue heterogeneities. In this study, dosimetric accuracy of Monte Carlo (MC) advanced dose calculation and sequential algorithms of Multiplan treatment planning system were investigated for small radiation fields incident on homogeneous and heterogeneous geometries. Methods: Small open fields of fixed cones of Cyberknife M6 unit 100 to 500 mm2 were used for this study. The fields were incident on in house phantom containing lung, air, and bone inhomogeneities and also homogeneous phantom. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. The dosimetric accuracy of MC and sequential algorithms in the presence of the inhomogeneities was compared against EBT3 film dosimetry Results: Open field tests in a homogeneous phantom showed good agreement between two algorithms and film measurement For MC algorithm, the minimum gamma analysis passing rates between measured and calculated dose distributions were 99.7% and 98.3% for homogeneous and inhomogeneous fields in the case of lung and bone respectively. For sequential algorithm, the minimum gamma analysis passing rates were 98.9% and 92.5% for for homogeneous and inhomogeneous fields respectively for used all cone sizes. In the case of the air heterogeneity, the differences were larger for both calculation algorithms. Overall, when compared to measurement, the MC had better agreement than sequential algorithm. Conclusion: The Monte Carlo calculation algorithm in the Multiplan treatment planning system is an improvement over the existing sequential algorithm. Dose discrepancies were observed for in the presence of air inhomogeneities.

60 APPLIED LIFE SCIENCES↗

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

Transport error estimation using residual Monte Carlo

The residual Monte Carlo (RMC) method is also known in the literature as sequential Monte Carlo and reduced-source Monte Carlo. Given a Monte Carlo method for solving a linear equation and an approximate solution to that system, the residual method enables use of essentially the same Monte Carlo algorithm to directly compute the additive error or “defect” associated with the approximate solution. As the size of the defect decreases relative to the size of the solution, the residual Monte Carlo method becomes increasingly efficient relative to the standard Monte Carlo (SMC) method. Here we present a new RMC algorithm for evaluating the space-angle error in S n radiation transport solutions, and provide computational examples demonstrating that it can be far more efficient than SMC for this purpose. Herein we also describe a particular pitfall that must be avoided if RMC is to be efficient, and explain why the performance of RMC can significantly differ between different transport problems and different quantities of interest for the same problem.

97 MATHEMATICS AND COMPUTING↗