Network-Level Optimization for Unbalanced Power Distribution System: Approximation and Relaxation

The nonlinear programming (NLP) problem to solve distribution-level optimal power flow (D-OPF) poses convergence issues and does not scale well for unbalanced distribution systems. The existing scalable D-OPF algorithms either use approximations that are not valid for an unbalanced power distribution system, or apply relaxation techniques to the nonlinear power flow equations that do not guarantee a feasible power flow solution. In this paper, we propose scalable D-OPF algorithms that simultaneously achieve optimal and feasible solutions by solving multiple iterations of approximate, or relaxed, D-OPF subproblems of low complexity. The first algorithm is based on a successive linear approximation of the nonlinear power flow equations around the current operating point, where the D-OPF solution is obtained by solving multiple iterations of a linear programming (LP) problem. The second algorithm is based on the relaxation of the nonlinear power flow equations as conic constraints together with directional constraints, which achieves optimal and feasible solutions over multiple iterations of a second-order cone programming (SOCP) problem. Finally, it is demonstrated that the proposed algorithms are able to reach an optimal and feasible solution while significantly reducing the computation time as compared to an equivalent NLPD-OPF model for the same distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Cost and Benefit of Enhancing Cybersecurity for Hybrid AC/DC Grids

As critical interfaces of AC grids and DC grids inside a hybrid AC/DC grid, the voltage-sourced-converter (VSC) has been demonstrated to be vulnerable to false data injection (FDI) cyber-attacks. As a result, the cyber-attack-induced AC grid frequency deviations and DC grid voltage deviations threaten the secure operation. Here, to enhance cybersecurity in a not only feasible but also cost-effective manner, this paper proposes a cost-benefit-based cyber-defense strategy for a hybrid AC/DC grid. First, this paper establishes a spatial-temporal dual cyber-attack evaluation model, in which the cyber-attack-induced frequency and voltage deviations are modelled in both a spatially and temporally dual manner. Then, the proposed cost-benefit-based cyber-defense strategy is modelled as a VSC commitment problem to achieve the trade-off between maximizing the cyber-defense benefits and minimizing the cyber-defense costs. The VSC commitment problem is then mathematically convexified into a mixed-integer second-order cone programming (MISOCP) problem, which could be efficiently solved in an event-triggered manner against unfolding cyber-attack events. Simulation results on a test hybrid AC/DC grid verified the feasibility and the cost-effectiveness of the proposed cyber-defense strategy.

cost-benefit analysis↗

Efficient Region of Attraction Characterization for Control and Stabilization of Load Tap Changer Dynamics

In this article, we study the monitoring and control of long-term voltage stability considering load tap changer (LTC) dynamics. We show that under generic conditions, the LTC dynamics admit a unique stable equilibrium. For the stable equilibrium, we characterize an explicit inner approximation of its largest region of attraction (ROA). Compared to existing results, the computational complexity of the ROA characterization is drastically reduced. We propose a quadratically constrained linear program formulation for the ROA characterization problem. In addition, we formulate a second-order cone program for online voltage stability monitoring and control exploiting the proposed ROA characterization. Finally, we demonstrate the efficacy of the proposed formulations on the ROA characterization and stability monitoring and control using a standard IEEE test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.