Engineering PapersSearch

SEARCH · Engineering Papers

Results for “screening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simulator comparison of thumball, thumb switch, and touch screen input concepts for interaction with a large screen cockpit display format

A piloted simulation study was conducted comparing three different input methods for interfacing to a large screen, multiwindow, whole flight deck display for management of transport aircraft systems. The thumball concept utilized a miniature trackball embedded in a conventional side arm controller. The multifunction control throttle and stick (MCTAS) concept employed a thumb switch located in the throttle handle. The touch screen concept provided data entry through a capacitive touch screen installed on the display surface. The objective and subjective results obtained indicate that, with present implementations, the thumball concept was the most appropriate for interfacing with aircraft systems/subsystems presented on a large screen display. Not unexpectedly, the completion time differences between the three concepts varied with the task being performed, although the thumball implementation consistently outperformed the other two concepts. However, pilot suggestions for improved implementations of the MCTAS and touch screen concepts could reduce some of these differences.

Jones, Denise R.

Comparison of experimental and theoretical turbulence reduction characteristics for screens, honeycomb, and honeycomb-screen combinations

Turbulence reduction research using screens, honeycomb, and combinations thereof was conducted in a half-scale model of a portion of the Langley 8-foot transonic pressure tunnel. It was found that screens alone reduce axial turbulence more than lateral turbulence; whereas, honeycomb alone reduces laterial turbulence more than axial turbulence. Because of this difference, the physical mechanism for decreasing turbulence for screens and honeycomb must be completely different. It is concluded that honeycomb with a downstream screen is an excellent combination for reducing turbulences.

Scheiman, J.

A comparison of experimental and theoretical turbulence reduction from screens, honeycomb and honeycomb-screen combinations

A 1/2-scale model of a portion of the NASA Langley 8-foot transonic pressure tunnel was used to conduct some turbulence reduction research. The experimental results are correlated with various theories. Screens alone reduce axial turbulence more than the lateral turbulence; whereas, honeycomb alone reduce lateral turbulence more than axial turbulence. Because of this difference, the physical mechanism for decreasing turbulence for screens and honeycomb must be completely different. Honeycomb with a downstream screen is an excellent combination for reducing turbulence.

Scheiman, J.

Two-Piece Screens for Decontaminating Granular Material

Two-piece screens have been designed specifically for use in filtering a granular material to remove contaminant particles that are significantly wider or longer than are the desired granules. In the original application for which the twopiece screens were conceived, the granular material is ammonium perchlorate and the contaminant particles tend to be wires and other relatively long, rigid strands. The basic design of the twopiece screens can be adapted to other granular materials and contaminants by modifying critical dimensions to accommodate different grain and contaminant- particle sizes. A two-piece screen of this type consists mainly of (1) a top flat plate perforated with circular holes arranged in a hexagonal pattern and (2) a bottom plate that is also perforated with circular holes (but not in a pure hexagonal pattern) and is folded into an accordion structure. Fabrication of the bottom plate begins with drilling circular holes into a flat plate in a hexagonal pattern that is interrupted, at regular intervals, by parallel gaps. The plate is then folded into the accordion structure along the gaps. Because the folds are along the gaps, there are no holes at the peaks and valleys of the accordion screen. The top flat plate and the bottom accordion plate are secured within a metal frame. The resulting two-piece screen is placed at the bottom opening of a feed hopper containing the granular material to be filtered. Tests have shown that such long, rigid contaminant strands as wires readily can pass through a filter consisting of the flat screen alone and that the addition of the accordion screen below the flat screen greatly increases the effectiveness of removal of wires and other contaminant strands. Part of the reason for increased effectiveness is in the presentation of the contaminant to the filter surface. Testing has shown that wire type contamination will readily align itself parallel to the material direction flow. Since this direction of flow is nearly always perpendicular to the filter surface holes, the contamination is automatically aligned to pass through. The two-filter configuration reduces the likelihood that a given contaminant strand will be aligned with the flow of material by eliminating the perpendicular presentation angle. Thus, for wires of a certain diameter, a two-piece screen is 20 percent more effective than is the corresponding flat perforated plate alone, even if the holes in the flat plate are narrower. An accordion screen alone is similarly effective in catching contaminants, but lumps of agglomerated granules of the desired material often collect in the valleys and clog the screen. The addition of a flat screen above the accordion screen prevents clogging of the accordion screen. Flat wire screens have often been used to remove contaminants from granular materials, and are about as effective as are the corresponding perforated flat plates used alone.

Backes, Douglas

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE

Optimal Stopping Ages for Colorectal Cancer Screening

Importance Prior studies have shown that the benefits, harms, and costs of colorectal cancer (CRC) screening at older ages are associated with a patient’s sex, health, and screening history. However, these studies were hypothetical exercises and not directly informed by data on CRC risk. Objective To identify the optimal stopping ages for CRC screening by sex, comorbidity, and screening history from a cost-effectiveness perspective. Design, Setting, and Participants This economic evaluation first validated the MISCAN-Colon (Microsimulation Screening Analysis–Colon) model against community-based CRC incidence and mortality rates for 2 subcohorts of the PRECISE (Optimizing Colorectal Cancer Screening Precision and Outcomes in Community-Based Populations) cohort. Subsequently, different CRC screening scenarios were simulated in older individuals. Cohorts of US adults aged 76 to 90 years varied by sex and comorbidity status (none, low, moderate, or severe). Statistical and sensitivity analyses were performed from March 2023 to May 2024. Exposures CRC screening histories including fecal immunochemical test (FIT) or colonoscopy, such as a negative colonoscopy result from 10, 15, 20, 25, or 30 years before the index age; 1 to 5 negative FIT results within 5 years of the index age, with different patterns of recency; or a combination of negative colonoscopy and negative FIT results. Main Outcomes and Measures The main outcomes included estimated lifetime clinical outcomes, incremental costs, and quality-adjusted life-years gained (QALYG) associated with 1 additional FIT or colonoscopy. Optimal stopping age for screening, defined as the oldest age for which the incremental cost-effectiveness ratio was still below the willingness-to-pay threshold of $\$$100 000 per QALYG, was evaluated. Results The first of the 2 PRECISE subcohorts used in validating the simulation model included 25 974 adults (15 060 females [58.0%]; 54.7% aged 76 to 80 years) with a negative colonoscopy result 10 years before the index date. The second subcohort consisted of 118 269 adults (67 058 females [56.7%]; 90.5% aged 76 to 80 years) with a negative FIT result 1 year before the index date. Older age, male sex, higher comorbidity levels, and recent CRC screenings were associated with reduced incremental benefit and cost-effectiveness of additional screening. For the reference cohort of 76-year-old females without comorbidities and a negative colonoscopy result 10 years before the index age, 1 additional colonoscopy cost $\$$38 226 per QALYG. For cohorts with otherwise equivalent characteristics, associated costs increased to $\$$1 689 945 per QALYG for females at age 90 years without comorbidities and a negative colonoscopy results 10 years before the index age, $\$$51 604 per QALYG for males at age 76 years without comorbidities and a negative colonoscopy result 10 years before the index age, and $\$$108 480 per QALYG for females at age 76 years with severe comorbidities and a negative colonoscopy result 10 years before the index age and decreased to $\$$16 870 per QALYG for females without comorbidities and a negative colonoscopy result 30 years before the index age. The optimal stopping ages across different cohorts ranged from younger than 76 to 86 years for colonoscopy and younger than 76 to 88 years for FIT. Conclusions and Relevance In this economic evaluation, age, sex, screening history, comorbidity, and future screening modality were associated with the clinical outcomes, cost-effectiveness, and optimal stopping age for CRC screening. These results can inform guideline development and patient-directed informed decision-making.

Harlass, Matthias [Erasmus Erasmus University Medi

Measurement of heat conduction through stacked screens

This paper describes the experimental apparatus for the measurement of heat conduction through stacked screens as well as some experimental results taken with the apparatus. Screens are stacked in a fiberglass-epoxy cylinder, which is 24.4 mm in diameter and 55 mm in length. The cold end of the stacked screens is cooled by a Gifford-McMahon (GM) cryocooler at cryogenic temperature, and the hot end is maintained at room temperature. Heat conduction through the screens is determined from the temperature gradient in a calibrated heat flow sensor mounted between the cold end of the stacked screens and the GM cryocooler. The samples used for these experiments consisted of 400-mesh stainless steel screens, 400-mesh phosphor bronze screens, and two different porosities of 325-mesh stainless steel screens. The wire diameter of the 400-mesh stainless steel and phosphor bronze screens was 25.4 micrometers and the 325-mesh stainless steel screen wire diameters were 22.9 micrometers and 27.9 micrometers. Standard porosity values were used for the experimental data with additional porosity values used on selected experiments. The experimental results showed that the helium gas between each screen enhanced the heat conduction through the stacked screens by several orders of magnitude compared to that in vacuum. The conduction degradation factor is the ratio of actual heat conduction to the heat conduction where the regenerator material is assumed to be a solid rod of the same cross sectional area as the metal fraction of the screen. This factor was about 0.1 for the stainless steel and 0.022 for the phosphor bronze, and almost constant for the temperature range of 40 to 80 K at the cold end.

NASA Discipline Environmental Health

Fatigue failure of regenerator screens in a high frequency Stirling engine

Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenerator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain a 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.

Hull, David R.

Fatigue failure of regenerator screens in a high frequency Stirling engine

Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.

Hull, David R.

Variable Shadow Screens for Imaging Optical Devices

Variable shadow screens have been proposed for reducing the apparent brightnesses of very bright light sources relative to other sources within the fields of view of diverse imaging optical devices, including video and film cameras and optical devices for imaging directly into the human eye. In other words, variable shadow screens would increase the effective dynamic ranges of such devices. Traditionally, imaging sensors are protected against excessive brightness by use of dark filters and/or reduction of iris diameters. These traditional means do not increase dynamic range; they reduce the ability to view or image dimmer features of an image because they reduce the brightness of all parts of an image by the same factor. On the other hand, a variable shadow screen would darken only the excessively bright parts of an image. For example, dim objects in a field of view that included the setting Sun or bright headlights could be seen more readily in a picture taken through a variable shadow screen than in a picture of the same scene taken through a dark filter or a narrowed iris. The figure depicts one of many potential variations of the basic concept of the variable shadow screen. The shadow screen would be a normally transparent liquid-crystal matrix placed in front of a focal-plane array of photodetectors in a charge-coupled-device video camera. The shadow screen would be placed far enough from the focal plane so as not to disrupt the focal-plane image to an unacceptable degree, yet close enough so that the out-of-focus shadows cast by the screen would still be effective in darkening the brightest parts of the image. The image detected by the photodetector array itself would be used as feedback to drive the variable shadow screen: The video output of the camera would be processed by suitable analog and/or digital electronic circuitry to generate a negative partial version of the image to be impressed on the shadow screen. The parts of the shadow screen in front of those parts of the image with brightness below a specified threshold would be left transparent; the parts of the shadow screen in front of those parts of the image where the brightness exceeded the threshold would be darkened by an amount that would increase with the excess above the threshold.

Lu, Ed

Determination of the NOAA-20 VIIRS screen transmittance functions with both the yaw maneuver and regular on-orbit calibration data

The Visible Infrared Imaging Radiometer Suite (VIIRS) aboard theNOAA-20 satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs) through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and then scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD’s bidirectional reflectance distribution function (BRDF), referred to as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM) whose eight detectors alternately observe the Sun through another attenuation screen (the SDSM screen) and the sunlit SD. The products of the SD screen transmittance and the BRDF at the mission start for both the SDSM and RSBs and the SDSM screen effective transmittance were measured prelaunch. Large unrealistic undulations in the retrieved H-factor were seen when using the prelaunch screen functions. To improve the accuracy of the retrieved H-factor, shortly after the satellite launch, 15 yaw maneuvers were performed to further characterize the screens. Although significantly improved, the H-factor derived using the screen functions determined fromthe yaw maneuver data still has large unrealistic undulations, revealing that the solar azimuth angular step size of the yaw maneuvers is too large. In this paper,we add high-quality regular on-orbitSDcalibration data to the yaw maneuver data to further improve the relative product of the SD screen effective transmittance and the BRDF at the mission start for the SDSM and the SDSM screen relative effective transmittance. The H-factor time series derived from the newly determined screen transmittance functions is much smoother than that derived from using only the yaw maneuver data and thus considerably improves the radiometric calibration accuracy.

Ning Lei

Initial Determination of the NOAA-20 VIIRS Screen Transmittances with Both Yaw Maneuver and Regular on Orbit Data

One of the scientific instruments aboard the NOAA-20 satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). The VIIRS regularly performs on-orbit radiometric calibration of its reflective solar bands, primarily through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD bidirectional reflectance distribution function (BRDF), denoted as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM). The eight SDSM detectors observe the sun through another attenuation screen (the SDSM screen) and the sunlit SD almost at the same time to measures the SD BRDF change. The products of the SD screen transmittance and the BRDF at t=0 and the SDSM screen transmittance were measured prelaunch. Large undulations in the H-factor were seen when using the prelaunch screen transmittances. Fifteen on-orbit yaw maneuvers were performed to validate and to further characterize the screens. Although significantly improved, the H-factor from the yaw maneuver data determined screen transmittance still has undulations as large as about 0.7-0.8%, revealing that the angular step size of the yaw maneuvers is too large. In this paper, we add regular on-orbit data to the yaw maneuver data to further improve the relative products and the relative SDSM screen transmittance. The H-factor time series derived from the newly determined screen transmittance is much smoother than that derived from using only the yaw maneuver data and thus improves considerably the radiometric calibration accuracy.

Lei, Ning

A Transient Hydrodynamic Model of Screen Channel Liquid Acquisition Devices for In-Space Cryogenic Propellant Management

Screen channel liquid acquisition devices (LADs) will play a crucial role in future deep space travel. It is essential that vapor-free delivery of propellants during tank-to-tank transfer is ensured to maximize yield from storage tanks and prevent potential combustion instabilities. The screen channel LAD utilizes a fine screen wire mesh that can separate phases in a low Bond number (i.e. microgravity) environment using surface tension forces. This study presents the development and verification of a new model for transient screen compliance, one of the influential factors for screen channel LAD design. Screen compliance is crucial during LAD channel outflow transients because the slight deflection of the screen can provide needed mass to satisfy rapid outflow demands and reduce the pressure difference across the screen. The model is successfully verified against CFD simulations. In addition, the characteristic speed for the governing screen compliance equations is derived which allows for numerical stability criteria to be established. As shown in this study, the transient maximum pressure difference across the screen can greatly exceed the steady state maximum pressure difference across the screen in many cases.

Hydrodynamics Simulations

Screening EEG in Aircrew Selection: Clinical Aerospace Neurology Perspective

As clinical aerospace neurologists we do not favor using screening EEG in pilot selection on unselected and otherwise asymptomatic individuals. The role of EEG in aviation screening should be as an adjunct to diagnosis, and the decision to disqualify a pilot should never be based solely on the EEG. Although a policy of using a screening EEG in an unselected population might detect an individual with a potentially increased relative risk, it would needlessly exclude many applicants who would probably never have a seizure. A diagnostic test performed on an asymptomatic individual without clinical indications, in a population with a low prevalence of disease (seizure) may be of limited or possibly detrimental value. We feel that rather than do EEGs on all candidates, a better approach would be to perform an EEG for a specific indication, such as family history of seizure, single convulsion (seizure) , history of unexplained loss of consciousness or head injury. Routine screening EEGs in unselected aviation applications are not done without clinical indication in the U.S. Air Force, Navy, or NASA. The USAF discontinued routine screening EEGs for selection in 1978, the U.S. Navy discontinued it in 1981 , and NASA discontinued it in 1995. EEG as an aeromedical screening tool in the US Navy dates back to 1939. The US Navy routinely used EEGs to screen all aeromedical personnel from 1961 to 1981. The incidence of epileptiform activity on EEG in asymptomatic flight candidates ranges from 0.11 to 2.5%. In 3 studies of asymptomatic flight candidates with epileptiform activity on EEG followed for 2 to 15 years, 1 of 31 (3.2%), 1 of 30 (3.3%), and 0 of 14 (0%) developed a seizure, for a cumulative risk of an individual with an epileptiform EEG developing a seizure of 2.67% (2 in 75). Of 28,658 student naval aviation personnel screened 31 had spikes and/or slow waves on EEG, and only 1 later developed a seizure. Of the 28,627 who had a normal EEG, 4 later developed seizures, or .0139% (4/28627). After review of the value of the EEG as a screening tool, the US Navy now uses EEG only for certain clinical indications (head injury, unexplained loss of consciousness, family history of epilepsy, and abnormal neurological exam). Currently the US Navy does not use EEG for screening for any flight applicant without a neurologic indication. In the US Navy, an electroencephalographic pattern is determined to be epileptiform by a neurologist.

Clark, Jonathan B.

Modeling transmittance of MODIS solar diffuser stability monitor sun view screen

Earlier work by Sun et al. [2005] modeled the Sun view screen transmittance of the solar diffuser stability monitor (SDSM) on Moderate Resolution Imaging Spectroradiometer (MODIS) which explains the oscillatory pattern in the Terra/Aqua MODIS SDSM Sun view response collected during the post-launch yaw maneuvers. The SDSM screen consists of small size pinholes which limit the screen transmittance. The SDSM Sun view transmittance pattern is affected by the size and distribution of pinholes, screen thickness, and orientation between the aperture stop and the Sun view screen. Planning of post-launch yaw maneuver test often requires comprehensive angular coverage to resolve the angular variation of the screen transmittance. This paper developed a Gauss-Kronrod quadrature method-based model to simulate the SDSM Sun view transmittance. This method performs iterative integration of the interception area between pinhole and aperture stop which is critical in the screen transmittance calculation. Parametric dependences of the MODIS SDSM Sun view transmittance on various geometric factors such as the pinhole size or spacing and misalignment between the SDSM Sun view screen and aperture stop are studied. The implications for the post-launch yaw maneuver planning to resolve the angular variation of the SDSM Sun view transmittance due to the SDSM Sun view screen misalignment are discussed.

MODIS

Effect of screens in wide-angle diffusers

An experimental investigation at low airspeeds was made of the filling effect observed when a screen or similar resistance is placed across a diffuser. The filling effect is found to be real in that screens can prevent separation or restore separated flow in diffusers even of extreme divergence and to depend principally on screen location and pressure-drop coefficient of the screen. Results are given for three different diffusers of circular cross section with a variety of screen arrangements. Effects of single screens and multiple screens are shown. The mechanics of the filling effect is explained, and possible efficiencies are discussed. Results of arrangements of multiple screens in wide-angle diffusers are given to show a possible application to damping screens as used in wind tunnels to reduce turbulence. (author)

Schubauer, G B

NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid

While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.

Wollen, Mark

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN