Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new water-based scintillator for efficient Cherenkov and scintillation separation

Neutrinos offer a unique window into the world around us, allowing us to probe otherwise unreachable regions like the interior of stars and the depths of the earth, as well as potentially offering a mechanism for monitoring nuclear activity. Both pure-water and organic liquid scintillators have been used as the detection medium of large-scale neutrino detectors. Organic liquid scintillators offer higher sensitivity at lower energies, which is desirable for many applications, but detection of the Cherenkov radiation required for directional sensitivity is very difficult. A possible solution is to use water-based liquid scintillators (WbLSs), where some fraction of the water is replaced with a micellar solution of the liquid scintillator. This can enhance the detection sensitivity beyond that of pure water, without significantly affecting the ability to leverage the topological Cherenkov signature. Very specific scintillation properties are required to achieve this goal: the scintillation decay time should be significantly slower than that of the Cherenkov emission, so timing-based discrimination of Cherenkov light from scintillation can be applied. At the same time, the light yield should be high enough to enhance the overall sensitivity of the detector, but without losing too much of the Cherenkov light. In this study, we report a new water-based liquid scintillation cocktail based on a 9-methylcarbazole fluorescent dye and a linear alkylbenzene solvent. Here, the proposed composition offers 13.8 ns scintillation decay time and 368 nm emission that matches the desired properties.

Wolszczak, Weronika W. [Lawrence Berkeley National↗

Characterization of water-based liquid scintillator for Cherenkov and scintillation separation

Abstract This paper presents measurements of the scintillation light yield and time profile for a number of concentrations of water-based liquid scintillator, formulated from linear alkylbenzene (LAB) and 2,5-diphenyloxazole (PPO). We find that the scintillation light yield is linear with the concentration of liquid scintillator in water between 1 and 10% with a slope of $$127.9\pm 17.0$$ 127.9 ± 17.0 ph/MeV/concentration and an intercept value of $$108.3\pm 51.0$$ 108.3 ± 51.0 ph/MeV, the latter being illustrative of non-linearities with concentration at values less than 1%. This is larger than expected from a simple extrapolation of the pure liquid scintillator light yield. The measured time profiles are consistently faster than that of pure liquid scintillator, with rise times less than 250 ps and prompt decay constants in the range of 2.1–2.85 ns. Additionally, the separation between Cherenkov and scintillation light is quantified using cosmic muons in the CHESS experiment for each formulation, demonstrating an improvement in separation at the centimeter scale. Finally, we briefly discuss the prospects for large-scale detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cherenkov and scintillation separation in water-based liquid scintillator using an LAPPDTM

Abstract This manuscript describes measurements of water-based liquid scintillators (WbLS), demonstrating separation of the Cherenkov and scintillation components using a low energy $$\beta $$ β source and the fast timing response of a Large Area Picosecond Photodetector (LAPPD). Additionally, the time profiles of three WbLS mixtures, defined by the relative fractions of scintillating compound, are characterized, with improved sensitivity to the scintillator rise-time. The measurements were made using both an LAPPD and a conventional photomultiplier tube (PMT). All samples were measured with an effective resolution $$O\left( 100~\text {ps}\right) $$ O 100 ps , which allows for the separation of Cherenkov and scintillation light (henceforth C/S separation) by selecting on the arrival time of the photons alone. The Cherenkov purity of the selected photons is greater than 60% in all cases, with greater than 80% achieved for a sample containing 1% scintillator. This is the first demonstration of the power of synthesizing low light yield scintillators, of which WbLS is the canonical example, with fast photodetectors, of which LAPPDs are an emerging leader, and has direct implication for future mid- and large-scale detectors, such as Theia , ANNIE, and AIT-NEO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillator Library: A database of inorganic and organic scintillator properties

The Scintillator Library (scintillator.lbl.gov) is a database of scintillator properties hosted by Lawrence Berkeley National Laboratory in a web-accessible format. It contains a variety of measured inorganic and organic scintillator properties extracted from peer-reviewed literature and manufacturer specifications. Data housed within the Scintillator Library supply an important resource for developers of scintillator-based detection systems and an aid for scientists seeking to establish connections between fundamental material and chemical properties and the associated scintillation performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the scintillation response of water-based liquid scintillator to alpha particles, and implications for particle identification

Next-generation large-scale neutrino detectors, from EOS, at the 1 t scale, to THEIA, at the 10 s-of-kt scale, will utilize differences in both the scintillation and Cherenkov light emission for different particle species to perform background rejection. This manuscript presents measurements of the scintillation light yield and emission time profile of water-based liquid scintillator samples in response to α radiation. These measurements are used as input to simulation models used to make predictions for future detectors. In particular, we present the timing-based particle identification achievable in generic water-based scintillator detectors at the 4 t, 1 kt, and 100 kt scales. We find that α/β discrimination improves with increasing scintillation concentration and we identify better than 80% α rejection for 90% β acceptance in 10% water-based liquid scintillator, at the 4 t scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crystal growth and scintillation properties of new ytterbium-activated scintillators Cs 4 CaI 6 :Yb and Cs 4 SrI 6 :Yb

Yb 2+ was investigated as a potential alternative activator for Cs 4 SrI 6 and Cs 4 CaI 6 scintillators for the first time, as opposed to the previously studied Eu2+ activator. Single crystals with nominal Yb 2+ concentrations of 0.5 mol%, 1 mol%, and 3 mol% were grown in Ø7 mm ampoules using the vertical Bridgman method. Luminescence and scintillation properties were evaluated as a function of Yb 2+ concentration and host compound. Here, the 5d → 4f electronic transition of Yb 2+ was observed for both the Sr- and Ca-containing compositions. X-ray induced radioluminescence emission was centered between 449 nm and 463 nm depending on Yb 2+ concentration and host compound. Both the spin-allowed and spin-forbidden transitions were observed in photoluminescence emission spectra and were centered at 446 nm and 476 nm, respectively, for both compounds. The best scintillation performance was achieved with Cs 4 CaI 6 :Yb 1 mol%, which had a 3.5% energy resolution at 662 keV and 43,000 ph/MeV light yield. To our knowledge this is the best energy resolution ever reported for a Yb 2+ -doped scintillator. Additional Cs 4 CaI 6 :Yb 1% crystals were grown in Ø12 mm ampoules to investigate the size dependence of scintillation properties, as well as crystal homogeneity.

36 MATERIALS SCIENCE↗

Codoping method for modifying the scintillation and optical properties of garnet-type scintillators

A method of tailoring the properties of garnet-type scintillators to meet the particular needs of different applications is described. More particularly, codoping scintillators, such as Gd 3 Ga 3 Al 2 O 12 , Gd 3 Ga 2 Al 3 O 12 , or other rare earth gallium aluminum garnets, with different ions can modify the scintillation light yield, decay time, rise time, energy resolution, proportionality, and/or sensitivity to light exposure. Also provided are the codoped garnet-type scintillators themselves, radiation detectors and related devices comprising the codoped garnet-type scintillators, and methods of using the radiation detectors to detect gamma rays, X-rays, cosmic rays, and particles having an energy of 1 keV or greater.

Tyagi, Mohit↗

Intrinsic scintillation performance & europium concentration effects in RbSr 2 I 5 and RbSr 2 Br 5 scintillators

Scintillators play crucial roles in homeland security applications like gamma ray spectroscopy and high energy X-ray radiography. For promising new scintillators, fine-tuning the luminescent dopant concentration is one avenue to further improve their performance and tailor their properties. In this work, the effects of europium dopant concentrations on the crystal growth, luminescence and scintillation properties of RbSr 2 Br 5 and RbSr 2 I 5 crystals was investigated. Nine transparent 7 mm diameter single crystals were grown via the Vertical Bridgman method. Here, the optical band gap of RbSr 2 Br 5 was 5.9 eV and that of RbSr 2 I 5 was 4.7 eV. High scintillation performance was achieved with a relatively low europium concentration of 1 mol%. For both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu crystals, light yield of 60–90,000 ph/MeV, energy resolution 2.8–4.0 % at 662 keV, and X-ray afterglow 0.79–1.5 % at 2 ms were obtained.

36 MATERIALS SCIENCE↗

Investigation of the competition between Tl + and Ce 3+ scintillation in Tl2LiYCl6:Ce, an elpasolite scintillator

Li-containing elpasolite scintillators are currently investigated for their ability to detect both thermal neutrons and gamma photons with a single inorganic crystal. The scintillation is typically triggered by using an activator such as Ce. However, when Tl, also a luminescent ion, is present in the matrix, competition between the two centers Tl and Ce can occur. In this study, we are using Ce doped Tl 2 LiYCl 6 to investigate this competition. To this end, the Ce (which substitutes Y) concentration is varied from 0 to 1 in the Tl 2 LiY 1-x CexCl 6 composition. In the low concentration range in which Ce remains a dopant, the photo- and radioluminescence spectra show that the scintillation of Tl 2 LiYCl 6 :Ce is mostly dominated by recombination on intrinsic luminescent centers. For cerium concentrations higher than x = 0.02, very different emissions can be easily distinguished from the photo- and radioluminescence of undoped and low Ce doped Tl 2 LiYCl 6 crystals. These emissions are attributed to the formation of a second phase Tl 2 CeCl 5 , identified by X-ray diffraction. We conclude that the intrinsic luminescence related to Tl dominates the scintillation in the range of concentration for which Ce does substitute on the Y-site.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy migration and scintillation kinetics in compositionally complex (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce single crystal scintillator

It is well-established that compositional tuning through binary admixture can improve scintillation performance in several materials systems, including Ce-activated garnets. Although recent work on ternary or quaternary cation admixture shows promise, the impact of this increased compositional complexity on thermal stability and carrier-defect dynamics has not been addressed. Here, we investigate a compositionally complex garnet, (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), grown by the Czochralski method using temperature-dependent photoluminescence (PL), PL decay, and thermoluminescence (TL). PL and PL decay measurements support a thermally activated Tb 3+ -Ce 3+ energy transfer, where Tb 3+ emission dominates below 60 K, but Ce 3+ emission increases from 20-300 K. Thermal quenching of Ce 3+ emission occurs around T 50 = 508 K, with an activation energy of 0.6 eV. TL and wavelength-resolved TL spectra from 20–500 K show that GYTLAG contains similar trap groups to LuAG but with a broader distribution of glow peaks below room temperature, possibly caused by quaternary cation mixing. A combination of dose dependence, partial cleaning and initial rise, and glow curve fitting to a first order continuous Gaussian distribution model are used to understand the contribution of electronic point defects to scintillation decay and afterglow at room temperature. Furthermore, these results inform how increased compositional complexity influences recombination dynamics in garnet scintillators.

Compositionally complex↗

Scintillation characteristics of the EJ-299-02H scintillator

Here a study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer to be 630 ± 110 nm. The relative light outputs from the decay of 241 Am and Compton scattering of electrons were used to extract Birks’ law coefficient, yielding a kB value of 0.087 ± 0.003 mm/MeV, consistent with some previous reports for other polystyrene-based scintillators. The results from these measurements are incorporated into the simulation to show that an energy threshold of (∼9 keV) can be achieved for the UCNProBe experiment. This low threshold enables high beta particle detection efficiency and the indirect measurement of UCN. The ability to make the scintillator deuterated, accompanied by its relatively thin dead layer, gives rise to unique applications in a wide range of UCN experiments, where it can be used to trap UCN and detect charged particles in situ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Luminescence and Scintillation in the Niobium Doped Oxyfluoride Rb4Ge5O9F6:Nb

A new niobium-doped inorganic scintillating oxyfluoride, Rb4Ge5O9F6:Nb, was synthesized in single crystal form by high-temperature flux growth. The host structure, Rb4Ge5O9F6, crystallizes in the orthorhombic space group Pbcn with lattice parameters a = 6.98430(10) Å, b = 11.7265(2) Å, and c = 19.2732(3) Å, consisting of germanium oxyfluoride layers made up of Ge3O9 units connected by GeO3F3 octahedra. In its pure form, Rb4Ge5O9F6 shows neither luminescence nor scintillation but when doped with niobium, Rb4Ge5O9F6:Nb exhibits bright blue luminescence and scintillation. The isostructural doped structure, Rb4Ge5O9F6:Nb, crystallizes in the orthorhombic space group Pbcn with lattice parameters a = 6.9960(3) Å, b = 11.7464(6) Å, and c = 19.3341(9) Å. X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) measurements suggest that the niobium is located in an octahedral coordination environment. Optical measurements inform us that the niobium dopant acts as the activator. The synthesis, structure, and optical properties are reported, including radioluminescence (RL) measurements under X-ray irradiation.

Carone, Darren (ORCID:0000000164014098)↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗