A MEMS Nanopositioner With Integrated Tip for Scanning Tunneling Microscopy
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Scanning tunneling microscopy (STM) methods are used to directly control the barrier height of a metal tunnel tip-semiconductor tunnel junction. Barrier behavior is measured by tunnel current-voltage spectroscopy and compared to theory. A unique surface preparation method is used to prepare a low surface state density Si surface. Control of band bending with this method enables STM investigation of semiconductor subsurface properties.
A scanning tunneling microscope (STM) combines unique capabilities in imaging and spectroscopy with atomic precision, and it can obtain energy-resolved spectroscopic data with atomic resolution. In this paper, we utilize a recently proposed modification to the STM feedback control loop to acquire high quality d 2 I/dV 2 images. We have developed a constant differential conductance imaging method by closing the STM feedback loop with a high precision dI/dV measurement. In this mode, the tip’s vertical position is adjusted so as to keep the differential conductance constant during raster scanning of the surface. Based on this imaging mode, we propose a new technique to acquire fast and reliable scanning tunneling spectroscopy (STS) data simultaneously with the imaging.
Abstract not provided.
A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between the tip and the sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here, we discuss another approach using a computer and data acquisition through the universal serial bus port. We find that it allows successful ultralow noise studies of surfaces at cryogenic temperatures. We show results on different compounds including a type II Weyl semimetal (WTe2), a quasi-two-dimensional dichalcogenide superconductor (2H–NbSe2), a magnetic Weyl semimetal (Co3Sn2S2), and an iron pnictide superconductor (FeSe).
Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically < 10 Hz) that the feedback circuit could respond, then the voltage applied to the piezoelectric tip-height actuator could be measured by use of a lock-in amplifier locked to the modulation (chopping) signal. However, at a high modulation frequency (typically in the kilohertz range or higher), the feedback circuit would be unable to respond. In this case, the photoenhanced portion of the tunneling current could be measured directly. For this purpose, the tunneling current would be passed through a precise resistor and the voltage drop would be measured by use of the lock-in amplifier.
Photon scanning tunneling microscopy (PSTM) is used to characterize Si3N4/Si02 optical channel waveguides being used for integrated optical-micromechanical sensors. PSTM utilizes an optical fiber tapered to a fine point which is piezoelectrically positioned to measure the decay of the evanescent field intensity associated with the waveguide propagating mode. Evanescent field decays are recorded for both ridge channel waveguides and planar waveguide regions. Values for the local effective refractive index are calculated from the data for both polarizations and compared to model calculations.
Various examples are provided related to scanning tunneling thermometers and scanning tunneling microscopy (STM) techniques. In one example, a method includes simultaneously measuring conductance and thermopower of a nanostructure by toggling between: applying a time modulated voltage to a nanostructure disposed on an interconnect structure, the time modulated voltage applied at a probe tip positioned over the nanostructure, while measuring a resulting current at a contact of the interconnect structure; and applying a time modulated temperature signal to the nanostructure at the probe tip, while measuring current through a calibrated thermoresistor in series with the probe tip. In another example, a device includes an interconnect structure with connections to a first reservoir and a second reservoir; and a scanning tunneling probe in contact with a probe reservoir. Electrical measurements are simultaneously obtained for temperature and voltage applied to a nanostructure between the reservoirs.
Various examples are provided related to scanning tunneling thermometers and scanning tunneling microscopy (STM) techniques. In one example, a method includes simultaneously measuring conductance and thermopower of a nanostructure by toggling between: applying a time modulated voltage to a nanostructure disposed on an interconnect structure, the time modulated voltage applied at a probe tip positioned over the nanostructure, while measuring a resulting current at a contact of the interconnect structure; and applying a time modulated temperature signal to the nanostructure at the probe tip, while measuring current through a calibrated thermoresistor in series with the probe tip. In another example, a device includes an interconnect structure with connections to a first reservoir and a second reservoir; and a scanning tunneling probe in contact with a probe reservoir. Electrical measurements are simultaneously obtained for temperature and voltage applied to a nanostructure between the reservoirs.
Among the many parts constituting a scanning tunneling microscope, the metallic tip is the component that directly interacts with the specimen and plays a critical role in visualizing the physical quantity of interest. While tip materials such as W and Pt–Ir are commonly used for topographic imaging and their preparation is well-documented, the preparation of plasmonic materials such as Ag for tip-enhanced Raman spectroscopy is relatively less standardized. Furthermore, we present several in situ Ag tip preparation and validation techniques for the microscopist to use depending on their intended application, including atomic resolution imaging, scanning tunneling spectroscopy (STM), and tip-enhanced Raman spectro-microscopy in ultrahigh vacuum. Besides optical applications, these methods are not limited to Ag but also applicable to other STM tip materials.
Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.
A vacuum compatible scanning tunneling microscope was designed and built, capable of imaging solid surfaces with atomic resolution. The single piezoelectric tube design is compact, and makes use of sample mounting stubs standard to a commercially available surface analysis system. Image collection and display is computer controlled, allowing storage of images for further analysis. Calibration results from atomic scale images are presented.
In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.
The combination of optical spectroscopy and scanning tunneling microscopy techniques has the potential to yield the unambiguous single-molecule level insight required to fully understand the complex structure–property relationship of emerging material systems. In this Perspective, we highlight the recent progress of single-molecule absorption detected by scanning tunneling microscopy (SMA-STM) to investigate light–matter interactions of supported (nano)particles, quantum dots, and molecular and thin films at the nanoscale. We further show how the SMA-STM technique has been recently extended to expand the classes of materials that can be investigated as well as recent design modifications that enable both time-resolved imaging and tomography. Finally, we hypothesize how these modifications can be further leveraged to advance our current knowledge of light–matter interactions and how the resulting nanoscale insight can be implemented for future material applications.
Atomically resolved images of highly oriented pyrolytic graphite (HOPG) in air at point contact have been obtained. Direct contact between tip and sample or contact through a contamination layer provides a conduction mechanism in addition to the exponential tunneling mechanism responsible for scanning tunneling microscopy (STM) imaging. Current-voltage (I-V) spectra were obtained while scanning in the current imaging mode with the feedback circuit interrupted in order to study the graphite imaging mechanism. Multiple tunneling tips are probably responsible for images without the expected hexagonal or trigonal symmetry. The observations indicate that the use of HOPG for testing and calibration of STM instrumentation may be misleading.
A new tip for scanning tunneling microscopy and a tip repair procedure that allows one to reproducibly obtain atomic images of highly oriented pyrolytic graphite with previously inoperable tips are reported. The tips are shown to be relatively oxide-free and highly resistant to oxidation. The tips are fabricated with graphite by two distinct methods.
The low-temperature scanning tunneling microscope (STM) system described by LeDuc et al. (1987) was used to observe the phonon density of states effects in a superconductor. Using techniques based on those employed in macroscopic tunneling spectroscopy, electron tunneling current-voltage (I-V) spectra were measured for NbN and Pb, and dI/dV vs V spectra were measured using standard analog derivative techniques. I-V measurements on NbN and Pb samples under typical STM conditions showed no evidence for multiparticle tunneling effects.
THz-pulse driven scanning tunneling microscopy (THz-STM) enables access to the ultrafast quantum dynamics of low-dimensional material systems at simultaneous ultrafast temporal and atomic spatial resolution. State-selective tunneling requires precise amplitude and phase control of the THz pulses combined with quantitative near-field waveform characterization. Here, we employ our state-of-the-art THz-STM with multi-MHz repetition rates, efficient THz generation, and precisely tunable THz waveforms to investigate a single sulfur vacancy in monolayer MoS2. We demonstrate that 2D transition metal dichalcogenides (TMDs) are an ideal platform for near-field waveform sampling by THz cross-correlation. Furthermore, we determine the THz voltage via QEV scans, which measure the THz rectified charge Q as a function of THz field amplitude E and dc bias Vdc. Mapping the complex energy landscape of localized states with a resolution down to 0.01 electrons per pulse facilitates state-selective tunneling to the HOMO and LUMO orbitals of a charged sulfur vacancy.