The BioMole Facility: Advancement of In Situ Microbiome Analysis for the International Space Station

Characterization of the International Space Station (ISS) microbiome has been enabled by sample return and Earth-based analysis. As human exploration pushes beyond low-Earth orbit, microbial-related crew health, planetary protection, and space research requires in situ capabilities. Steps toward reducing Earth-dependence for complex sample analysis began in 2016 with the amplification of DNA within the miniPCR thermal cycler and DNA sequencing with the MinION sequencer onboard the ISS; for both, samples were prepared on Earth. In 2017, these platforms synergistically enabled the in-situ identification of unknown bacteria collected and cultured from ISS surfaces, thereby shifting the paradigm that microbial cultures had to be returned to Earth. The following year, a culture-independent, swab-to-sequencer method further advanced spaceflight microbiology, demonstrating that culturing could be excluded and provided enhanced insight into the bacterial profile of ISS surfaces. Based on the success of these payloads in confirming the ability to meet crew health identification requirements and the benefits accompanying a culture-independent method, the BioMole Facility was established by the medical operations Crew Health Care Systems team. BioMole is the set of hardware, consumables, and procedures required to support sample preparation and nanopore sequencing onboard the ISS. BioMole goals include expanding sample sources, comparing data to previous methods, demonstrating onboard data analytics, and validating new hardware. To date, comparative surface analysis, molecular- and culture-based, has been completed. Additionally, the demonstration of a sample-to-answer process was achieved when BioMole data was processed onboard using the IBM Open Data and AI Edge software platform installed on the ISS-residing Spaceborne Computer-2. The taxonomic profiles generated from the edge analysis were as expected and paralleled that of the downlinked processed data. Future BioMole efforts involve microbial profiling of the ISS water system, ISS validation of the MinION Mk1C, and an expansion to a research facility available to investigators.

Sarah L. Castro-Wallace↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗

Development of In Situ Instruments for Planetary Exploration - Unique Challenges in Design, Development, and Execution

A viewgraph presentation describing in situ instruments for NASA missions is shown. The topics include: 1) In Situ Instrumentation; 2) Planetary Extremes; 3) Mars Surface Environment; 4) Lunar Precursor Mission Environment; 5) Europa Surface Analogue; 6) Other Parameters; 7) Space In Situ Instrumentation still in its Infancy; 8) Needed Capabilities For In Situ Science; 9) Framework For Putting The Pieces Together; 10) The Wild World of Astrobiology; 11) Timeline; 12) Example: MOD; 13) In Situ Sample Analysis Laboratories are more complex; 14) technologies In Situ Sample Analysis Requires Integration of Many Emerging Advanced Concepts; 15) Supporting technologies for In Situ Laboratories; 16) Micro-laboratory example; 17) In Situ Instrument Classes; and 18) Key for Analytical Instrument:Sample Preparation.

In Situ Instrumentation↗

Mass Spectrometry on Future Mars Landers

Mass spectrometry investigations on the 2011 Mars Science Laboratory (MSL) and the 2018 ExoMars missions will address core science objectives related to the potential habitability of their landing site environments and more generally the near-surface organic inventory of Mars. The analysis of complex solid samples by mass spectrometry is a well-known approach that can provide a broad and sensitive survey of organic and inorganic compounds as well as supportive data for mineralogical analysis. The science value of such compositional information is maximized when one appreciates the particular opportunities and limitations of in situ analysis with resource-constrained instrumentation in the context of a complete science payload and applied to materials found in a particular environment. The Sample Analysis at Mars (SAM) investigation on MSL and the Mars Organic Molecule Analyzer (MOMA) investigation on ExoMars will thus benefit from and inform broad-based analog field site work linked to the Mars environments where such analysis will occur.

Brinckerhoff, W. B.↗

Molecular Analyzer for Complex Refractory Organic-Rich Surfaces (MACROS)

The Molecular Analyzer for Complex Refractory Organic-rich Surfaces, MACROS, is a novel instrument package being developed at NASA Goddard Space Flight Center. MACROS enables the in situ characterization of a sample's composition by coupling two powerful techniques into one compact instrument package: (1) laser desorption/ionization time-of-flight mass spectrometry (LDMS) for broad detection of inorganic mineral composition and non-volatile organics, and (2) liquid-phase extraction methods to gently isolate the soluble organic and inorganic fraction of a planetary powder for enrichment and detailed analysis by liquid chromatographic separation coupled to LDMS. The LDMS is capable of positive and negative ion detection, precision mass selection, and fragment analysis. Two modes are included for LDMS: single laser LDMS as the broad survey mode and two step laser mass spectrometry (L2MS). The liquid-phase extraction will be done in a newly designed extraction module (EM) prototype, providing selectivity in the analysis of a complex sample. For the sample collection, a diamond drill front end will be used to collect rock/icy powder. With all these components and capabilities together, MACROS offers a versatile analytical instrument for a mission targeting an icy moon, carbonaceous asteroid, or comet, to fully characterize the surface composition and advance our understanding of the chemical inventory present on that body.

Getty, Stephanie A.↗

Polytopic vector analysis in igneous petrology: Application to lunar petrogenesis

Lunar samples represent a heterogeneous assemblage of rocks with complex inter-relationships that are difficult to decipher using standard petrogenetic approaches. These inter-relationships reflect several distinct petrogenetic trends as well as thermomechanical mixing of distinct components. Additional complications arise from the unequal quality of chemical analyses and from the fact that many samples (e.g., breccia clasts) are too small to be representative of the system from which they derived. Polytopic vector analysis (PVA) is a multi-variate procedure used as a tool for exploratory data analysis. PVA allows the analyst to classify samples and clarifies relationships among heterogenous samples with complex petrogenetic histories. It differs from orthogonal factor analysis in that it uses non-orthogonal multivariate sample vectors to extract sample endmember compositions. The output from a Q-mode (sample based) factor analysis is the initial step in PVA. The Q-mode analysis, using criteria established by Miesch and Klovan and Miesch, is used to determine the number of endmembers in the data system. The second step involves determination of endmembers and mixing proportions with all output expressed in the same geochemical variable as the input. The composition of endmembers is derived by analysis of the variability of the data set. Endmembers need not be present in the data set, nor is it necessary for their composition to be known a priori. A set of any endmembers defines a 'polytope' or classification figure (triangle for a three component system, tetrahedron for a four component system, a 'five-tope' in four dimensions for five component system, et cetera).

Shervais, John W.↗

Interferometer applications of VHF radars, part 3.6A

Using a spaced antenna setup of a VHF radar, the spatial distribution of amplitudes and phases of the radar echoes from the troposphere, stratosphere and mesosphere can be measured. Combining in a suitable analysis procedure the complex digital samples from the different receiving antennas is consistent with the radar interferometer method. In addition to the well-known parameters measured with the commonly applied Doppler and drifts methods, i.e., reflectivity and mean fluctuation velocity, the interferometer technique allows to measure the regular spectrum of the returns. This technique, which was first applied with the spaced antenna system of the SOUSY-VHF-Radar in W. Germany, as well as some first examples of results are described here. These comprise the measurements of the horizontal and vertical velocities of the mean flow as well as of turbulence structures, the aspect sensitivity and the tilt of layers from which the baroclinicity can be estimated. Particularly, results of interferometer measurements of the vertical and horizontal phase velocities and wavelengths of gravity waves in the stratosphere are displayed. The latter results are also discussed in terms of the generation and propagation of these waves.

Rottger, J.↗

Search for Chemical Biomarkers on Mars Using the Sample Analysis at Mars Instrument Suite on the Mars Science Laboratory

One key goal for the future exploration of Mars is the search for chemical biomarkers including complex organic compounds important in life on Earth. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) will provide the most sensitive measurements of the organic composition of rocks and regolith samples ever carried out in situ on Mars. SAM consists of a gas chromatograph (GC), quadrupole mass spectrometer (QMS), and tunable laser spectrometer to measure volatiles in the atmosphere and released from rock powders heated up to 1000 C. The measurement of organics in solid samples will be accomplished by three experiments: (1) pyrolysis QMS to identify alkane fragments and simple aromatic compounds; pyrolysis GCMS to separate and identify complex mixtures of larger hydrocarbons; and (3) chemical derivatization and GCMS extract less volatile compounds including amino and carboxylic acids that are not detectable by the other two experiments.

Glavin, D. P.↗

The Influence of Mineralogy on Recovering Organic Acids from Mars Analogue Materials Using the One-Pot Derivatization Experiment on the Sample Analysis at Mars(SAM) Instrument Suite

The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids, will require a chemical extraction and a derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed a ''one-pot'' extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment instrument suite on NASA's the Mars Science Laboratory (MSL) mission. The temperature and duration of the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 1C for several minutes of a variety of terrestrial Mars analog materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analog materials that contained high abundances of hydrated minerals, and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA. The combination of pyrolysis and two different wet-chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars.

MSL↗

On the Hilbert-Huang Transform Data Processing System Development

One of the main heritage tools used in scientific and engineering data spectrum analysis is the Fourier Integral Transform and its high performance digital equivalent - the Fast Fourier Transform (FFT). The Fourier view of nonlinear mechanics that had existed for a long time, and the associated FFT (fairly recent development), carry strong a-priori assumptions about the source data, such as linearity and of being stationary. Natural phenomena measurements are essentially nonlinear and nonstationary. A very recent development at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC), known as the Hilbert-Huang Transform (HHT) proposes a novel approach to the solution for the nonlinear class of spectrum analysis problems. Using the Empirical Mode Decomposition (EMD) followed by the Hilbert Transform of the empirical decomposition data (HT), the HHT allows spectrum analysis of nonlinear and nonstationary data by using an engineering a-posteriori data processing, based on the EMD algorithm. This results in a non-constrained decomposition of a source real value data vector into a finite set of Intrinsic Mode Functions (IMF) that can be further analyzed for spectrum interpretation by the classical Hilbert Transform. This paper describes phase one of the development of a new engineering tool, the HHT Data Processing System (HHTDPS). The HHTDPS allows applying the "T to a data vector in a fashion similar to the heritage FFT. It is a generic, low cost, high performance personal computer (PC) based system that implements the HHT computational algorithms in a user friendly, file driven environment. This paper also presents a quantitative analysis for a complex waveform data sample, a summary of technology commercialization efforts and the lessons learned from this new technology development.

Kizhner, Semion↗

Characterization of soil and postlaunch pad debris from Cape Canaveral launch complex and analysis of soil interaction with aqueous HCl

Soil samples were fractionated and analyzed in order to assess the physical and chemical interactions of entrained soil with solid-rocket exhaust clouds. The sandy soil consisted primarily of quartz (silica) particles, 30 to 500 microns in diameter, and also contained seashell fragments. Differential and cumulative soil-mass size distributions are presented along with mineralogy, elemental compositions, and solution pH histories. About 90 percent of the soil mass consisted of particles 165 microns in diameter. Characteristic reaction times in aqueous HC1 slurries varied from a few minutes to several days, and capacities for reaction under acidic conditions varied from 10 to 40 g HCl/kg soil, depending on particle size. Airborne lifetimes of particles 165 microns are conservatively 30 min, and this major grouping is predicted to represent a small short-term chemical sink for up to 5% of the total HC1. The smaller and more minor fractions, below a 165 micron diameter, may act as giant cloud condensation nuclei over much longer airborne lifetimes. Finally, the demonstrated time dependency of neutralization is a complicating factor; it can influence the ability to deduce in-cloud HCl scavenging with reaction and can affect the accuracy of measured chemical compositions of near-field wet deposition.

Pellett, G. L.↗

[Cyto-embryologic investigation of super dwarf wheat grown on board of the Mir orbital complex]

The cytoembryologic analysis of wet and dry samples of super dwarf wheat cultivated in greenhouse SVET aboard the MIR station over the whole cycle of vegetation was made with the use of light microscopy. Characteristic features of wheat development in space flight are plentiful early tillering, and formation and rapid growth of side shoots. Elementary spikelets in the composite head were more numerous but the top spikelets were rudimentary and, therefore, the ripe head contained less of these spikelets as compared with the ground controls (9-13 and 14, respectively). The number of florets in a spike was also higher reaching 14-16 vs. 7-8 in the control. Typically, no more than 4 to 5 florets vs. 3 in the control were fully differentiated while the others died off earlier in development. The fact that there were no caryopses found in the flight crop is explained by absolute male sterility appearing at different stages of staminal development: before archesporium formation, on the stage of differentiated archesporium, during meiosis, on the stage of microspores or uninucleate "pollen". The female generative system developed mainly without abnormalities. An assumption was made that elevated ethylene concentrations in the MIR atmosphere at the time of the wheat experiment were the cause for abnormal development of the male generative system which led to barrenness of the super dwarf wheat crop.

manned↗

The Validity Chlorophyll-a Estimation by Sun Induced Fluorescence in Estuarine Waters: An Analysis of Long-term (2003-2011) Water Quality Data from Tampa Bay, Florida (USA)

Satellite observation of phytoplankton concentration or chlorophyll-a is an important characteristic, critically integral to monitoring coastal water quality. However, the optical properties of estuarine and coastal waters are highly variable and complex and pose a great challenge for accurate analysis. Constituents such as suspended solids and dissolved organic matter and the overlapping and uncorrelated absorptions in the blue region of the spectrum renders the blue-green ratio algorithms for estimating chlorophyll-a inaccurate. Measurement of sun-induced chlorophyll fluorescence, on the other hand, which utilizes the near infrared portion of the electromagnetic spectrum, may provide a better estimate of phytoplankton concentrations. While modelling and laboratory studies have illustrated both the utility and limitations of satellite baseline algorithms based on the sun induced chlorophyll fluorescence signal, few have examined the empirical validity of these algorithms using a comprehensive long term in situ data set. In an unprecedented analysis of a long term (2003-2011) in situ monitoring data from Tampa Bay, Florida (USA), we assess the validity of the FLH product from the Moderate Resolution Imaging Spectrometer (MODIS) against chlorophyll ]a and a suite of water quality parameters taken in a variety of conditions throughout a large optically complex estuarine system. A systematic analysis of sampling sites throughout the bay is undertaken to understand how the relationship between FLH and in situ chlorophyll-a responds to varying conditions within the estuary including water depth, distance from shore and structures and eight water quality parameters. From the 39 station for which data was derived, 22 stations showed significant correlations when the FLH product was matched with in situ chlorophyll-alpha data. The correlations (r2) for individual stations within Tampa Bay ranged between 0.67 (n=28, pless than 0.01) and-0.457 (n=12, p=.016), indicating that for some areas within the Bay, FLH can be a good predictor of chlorophyll-alpha concentration and hence a useful tool for the analysis of water quality. Overall, the results show a 106% increase in the validity of chlorophyll -a concentration estimates using FLH over the standard the blue-green OC3M algorithm. This analysis also illustrates that the correlations between FLH and in situ chlorophyll -a measurements increases with increasing water depth and distance of the monitoring sites from both the shore and structures. However, due to confounding factors related to the complexity of the estuarine system, a linear improvement in the FLH to chlorophyll ]a relationship was not clearly noted with increasing depth and distance from shore alone. Correlations of FLH with turbidity, nutrients (total nitrogen and total phosphorous) biological oxygen demand, salinity, sea surface temperature correlated positively with FLH concentrations, while dissolved oxygen and pH showed negative correlations. Principle component analyses are employed to further describe the relationships between the multivariate water quality parameters and the FLH product. The majority of sites with higher and very significant correlations (pless than 0.01) also showed high correlation values for nutrients, turbidity and biological oxygen demand. These sites were on average in greater than seven meters of water and over five kilometers from shore. A thorough understanding of the relationship between the MODIS FLH product and in situ water quality parameters will enhance our understanding of the accuracy MODIS fs global FLH algorithm and assist in optimizing its calibration for use in monitoring the quality of estuarine and coastal waters worldwide.

Moreno-Madrinan, Max Jacobo↗

Applications of MODIS Fluorescent Line Height Measurements to Monitor Water Quality Trends and Algal Bloom Activity

Recent advances in satellite and airborne remote sensing, such as improvements in sensor and algorithm calibrations, processing techniques and atmospheric correction procedures have provided for increased coverage of remote-sensing, ocean-color products for coastal regions. In particular, for the Moderate Resolution Imaging Spectrometer (MODIS) sensor calibration updates, improved aerosol retrievals and new aerosol models has led to improved atmospheric correction algorithms for turbid waters and have improved the retrieval of ocean color in coastal waters. This has opened the way for studying ocean phenomena and processes at finer spatial scales, such as the interactions at the land-sea interface, trends in coastal water quality and algal blooms. Human population growth and changes in coastal management practices have brought about significant changes in the concentrations of organic and inorganic, particulate and dissolved substances entering the coastal ocean. There is increasing concern that these inputs have led to declines in water quality and have increase local concentrations of phytoplankton, which cause harmful algal blooms. In two case studies we present MODIS observations of fluorescence line height (FLH) to 1) assess trends in water quality for Tampa Bay, Florida and 2) illustrate seasonal and annual variability of algal bloom activity in Monterey Bay, California as well as document estuarine/riverine plume induced red tide events. In a comprehensive analysis of long term (2003-2011) in situ monitoring data and satellite imagery from Tampa Bay we assess the validity of the MODIS FLH product against chlorophyll-a and a suite of water quality parameters taken in a variety of conditions throughout a large optically complex estuarine system. A systematic analysis of sampling sites throughout the bay is undertaken to understand how the relationship between FLH and in situ chlorophyll-a responds to varying conditions and to develop a near decadal trend in water quality changes. In situ monitoring locations that correlated well with satellite imagery were in depths greater than seven meters and were located over five kilometers from shore. Water quality parameter of total nitrogen, phosphorous, turbidity and biological oxygen demand had high correlations with these sites, as well. Satellite FLH estimates show improving water quality from 2003-2007 with a slight decline up through 2011. Dinoflagellate blooms in Monterey Bay, California (USA) have recently increased in frequency and intensity. Nine years of MODIS FLH observations are used to describe the annual and seasonal variability of bloom activity within the Bay. Three classes of MODIS algorithms were correlated against in situ chlorophyll measurements. The FLH algorithm provided the most robust estimate of bloom activity. Elevated concentrations of phytoplankton were evident during the months of August-November, a period during which increased occurrences of dinoflagellate blooms have been observed in situ. Seasonal patterns of FLH show the on- and offshore movement of areas of high phytoplankton biomass between oceanographic seasons. Higher concentrations of phytoplankton are also evident in the vicinity of the land-based nutrient sources and outflows, and the cyclonic bay-wide circulation can transport these nutrients to the northern Bay bloom incubation region. Both of these case studies illustrate the utility MODIS FLH observations in supporting management decisions in coastal and estuarine waters.

Fischer, Andrew↗

Maximizing Spaceflight Biological Data with Omics Analytics: The NASA GeneLab Database

NASA’s GeneLab includes an open-access repository of some 250+ omics datasets generated by biological experiments relevant to spaceflight including simulated cosmic radiation and microgravity. In order to maximize the intelligibility of these data, particularly for users with limited bioinformatics background, GeneLab has become a knowledgebase platform converting raw genetic and proteomic signatures found in flight samples into biological and physiological meanings. A large community of more than 100 scientists has rallied behind GeneLab and organized into four Analysis Working Groups (AWGs: Animal, Plant, Microbe, and Multi-Omics). Together, the AWGs have gained scientific recognition worldwide by establishing a consortium in charge of adopting new complex standards for data analysis workflows and omics sample processing in a rapidly evolving field. We will demonstrate the usage of the repository with smart search capability, an online controlled-access toolshed "Galaxy" to process user data with vetted standard workflows, a workspace for data sharing and a data submission portal with ontology control for better metadata curation. The GeneLab visualization portal will also be demonstrated, showing how anyone without formal training in bioinformatics can now browse the space biology omics data to discover new biology and potential solutions to improve life in space.

Sylvain Vincent Costes↗

GeneLab: The NASA System Biology Platform for Space Omics Repository, Analysis and Visualization

NASA’s GeneLab includes an open-access repository of some 250+ omics datasets generated by biological experiments relevant to spaceflight including simulated cosmic radiation and microgravity. In order to maximize the intelligibility of these data, particularly for users with limited bioinformatics background, GeneLab has become a knowledgebase platform converting raw genetic and proteomic signatures found in flight samples into biological and physiological meanings. A large community of more than 100 scientists has rallied behind GeneLab and organized into four Analysis Working Groups (AWGs: Animal, Plant, Microbe, and Multi-Omics). Together, the AWGs have gained scientific recognition worldwide by establishing a consortium in charge of adopting new complex standards for data analysis workflows and omics sample processing in a rapidly evolving field. We will demonstrate the usage of the repository with smart search capability, an online controlled-access toolshed "Galaxy" to process user data with vetted standard workflows, a workspace for data sharing and a data submission portal with ontology control for better metadata curation. The GeneLab visualization portal will also be demonstrated, showing how anyone without formal training in bioinformatics can now browse the space biology omics data to discover new biology and potential solutions to improve life in space.

GeneLab↗

Microsampling techniques for infrared spectroscopic analysis of lunar and terrestrial minerals

Microsampling techniques have been developed for infrared analysis of single mineral grains from lunar rocks and dusts, allowing a detailed molecular structure characterization of these complex fine-grained samples. The methods include special devices for isolating single grains, preparing micropellets from the grains, and obtaining in situ microspecular reflectance spectra from grains in polished rock samples. Although specifically developed for the work on lunar samples, the special techniques for single grain infrared analysis were found to be equally useful in studies of complex terrestrial mineral samples. For example, infrared microanalysis has contributed substantially in solving problems concerned with our natural resources, such as the structural characterization of minerals from commercial iron ores, marine deposits, coal, and fly ash derived from coal.

Estep, P. A.↗

Analysis of interplanetary dust collections

Interplanetary dust particles collected in the form of micrometeorites in the stratosphere and meteor ablation spherules in deep sea sediments are possibly a relatively unbiased sample of the micrometeoroid complex near 1 AU. Detailed laboratory analysis of the particles has provided information on physical properties which may be useful in modeling a variety of aspects of interplanetary dust.

Brownlee, D. E.↗