Validation of a Hybrid Domain Overlapping Coupling Between SAM and CFD Against the TALL-3D Transients
The System Thermal Hydraulics (STH) code SAM has been coupled to the Computational Fluid Dynamics (CFD) code Simcenter STAR-CCM+ utilizing a hybrid domain overlapping method with an explicit coupling in time. The coupling aims to extend the STH code’s applicability to scenarios where local momentum and energy transfers are important yet difficult for STH codes to capture, such as three-dimensional (3D) mixing. The coupling method’s numerical stability was verified in the past against two closed-loop configurations, and it was validated against a double T-junction experiment with 3D scalar mixing. In the present work, the coupling method is validated against the TALL-3D STH/CFD coupling benchmark facility. TALL-3D is a three-legged, liquid-metal facility with a large, pool-type enclosure (test section) that exhibits 3D flow effects to be modeled by a CFD code. The rest of the system exhibits approximately 1D behavior well-predicted by an STH code. First, the present STAR-CCM+ CFD model of the 3D test section is validated against experimental data. Then, the SAM-STARCCM+ coupled model is validated against six different TALL-3D steady states, including SAM standalone model results for comparison. Lastly, the SAM-STARCCM+ coupled model is validated against two TALL-3D transients, one exhibiting flow reversal in the test section and one exhibiting nonlinear, Limit Cycle Oscillations (LCO). For the first transient, the SAM-STARCCM+ coupled model properly predicts an increase in the test section’s inlet temperature during flow reversal, and this is not predicted by the SAM standalone model. Following flow reversal, the SAM-STARCCM+ coupled model better-predicts the initial flow recovery and following oscillations as the system approaches a final natural circulation state. For the second transient, no true final steady state is observed due to LCO. Neither the SAM-STARCCM+ coupled model nor the SAM standalone model can perfectly capture the experiment’s changing oscillation frequency during the transient. However, the SAM-STARCCM+ coupled model does reproduce the oscillatory feedback observed in the system. This is a significant achievement as the SAM-STARCCM+ coupled model only uses an explicit coupling in time, as opposed to a semi-implicit coupling. In comparison, previous STH/CFD coupling efforts of the TALL-3D facility required semi-implicit coupling to obtain similar results.