Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rotating coil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements of HL-LHC AUP Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profile. A multi-probe, PCB-based rotating coil and Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. This paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements of $\mathrm{HL-LHC AUP}$ Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profiles. A multi-probe, PCB-based rotating coil and a Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. Here this paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent activities of National Synchrotron Light Source-II Insertion Device Group

Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.

47 OTHER INSTRUMENTATION↗

Field Harmonic Measurement of High-Gradient Permanent Magnet Quadrupoles for NSLS- II Upgrade

The National Synchrotron Light Source II (NSLS-II) is preparing for a major upgrade based on a new lattice concept, known as “Complex Bend,” to replace its existing double bend achromat (DBA) lattice. Here, this novel lattice will use high-gradient permanent magnet quadrupoles (PMQs) with small apertures in the range of 16–22 mm. A prototype complex bend branch with PMQs has been installed in the NSLS-II linac to evaluate the lattice's performance. An accurate and precise magnetic measurement system is required for field harmonic characterization and magnetic tuning of these PMQs. As part of this project a Rotating-Coil bench, based on a Printed Circuit Board (PCB) coil with a 12 mm diameter, has been configured to measure nine PMQs with bore diameter of 12.7 mm. This PCB coil has an active length of 270 mm, and is able to measure fields up to the 15th harmonic of the main field at a reference radius of 5 mm, while maintaining field quality levels within 10 ppm of the main field. This article presents the PCB coil setup, the harmonic measurement results and their temperature dependencies and repeatability. Simulation results on compensation of undesired multipoles using “IDBuilder”, a genetic algorithm-based optimizer code for magnetic tuning is included for field harmonic corrections.

36 MATERIALS SCIENCE↗

A New Magnetic Measurement System for the Future Low Emittance NSLS-II Storage Ring

A new magnetic measurement system is under construc-tion at BNL for accurate field harmonic measurements and fiducialization of magnets for a future upgrade of the NSLS- II storage ring. The entire storage ring is envi-sioned to be replaced with a new lattice concept, known as Complex Bend, which superimposes dipole and high-gradient quadrupole fields. The magnetic measurement system will use rotating wire and a PCB rotating coil specifically designed for small-aperture (< 15 mm) high gradient magnets. In this paper we describe in detail the mechanical design and the data acquisition hardware and software.

43 PARTICLE ACCELERATORS↗

Cost-effective Conductor, Cable, and Coils for High Field Rotating Electric Machines

The purpose of the DOE-AMMTO-funded project was to significantly reduce industrial energy intensity through manufacturing innovations. The project focused on superconducting technology for industrial motors to dramatically increase efficiency. The bottleneck in deploying high temperature superconducting (HTS) motors was high cost and low yield of the conductor manufacturing process. The process yield is low because of the defects in the conductor, forcing the manufacturers to cut off defective sections after characterizing each millimeter. Additionally, the piece lengths tend to be low because of the defects. The project tackled the low-yield manufacturing process challenge by devising an innovative method to use defective conductors in bundled cables without losing performance by engineering current sharing among the conductors. The innovation not only lowers the cost of the conductor but also enhances the reliability of HTS motors and other devices to mitigate the defects that might form during the fabrication and operation of the device. With the increasing interest in REBa2Cu3O7-x (REBCO)-coated conductors for various power, energy, and magnet applications, ensuring the reliability of HTS devices is of significant interest. The EERE funding allowed us to make significant progress in understanding the defects in manufactured conductors and the implications of the defects in superconducting electric motors and other superconducting power and energy applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Snakes for the Hadron Storage Ring

The Electron Ion Collider calls for collisions of polarized proton and polarized helion beams on polarized electron beams. To preserve polarization of these polarized hadron beams during acceleration, six full helical snakes will be installed. As there are currently 4 snakes in RHIC, the remaining two snakes will be made from existing rotator magnet coils. The existing snakes are made from only right-handed helices where the rotator magnets are made from both right handed and left handed helicity magnets. In order for a sufficient stock of spare coils, one snake will be made of left handed coils. Simulations using Opera field maps in zgoubi show the left handed snake has sufficient range to provide the desired snake precession axes for helions and protons with the existing power supplies. This is an overview of the right and left handed snake assemblies and their effects.

43 PARTICLE ACCELERATORS↗

Control rod drive mechanism (CRDM) with remote disconnect mechanism

The drive assembly includes annular drive magnets extending around a top end of a drive shaft and annular drive coils extending around the drive magnets, separated by a pressure boundary. A latch assembly is coupled to the drive magnets and engages with the drive shaft in response to actuation of the drive assembly. The drive coils also rotate the drive magnets and the engaged latch assembly to axially displace the drive shaft. Deactivating the drive coils disengages the latch assembly from the drive shaft, dropping a connected control rod assembly via gravity into a nuclear fuel assembly.

Lobscheid, Christian↗

Circuit Modeling, Simulation, and Experimental Validation of a 100-kW Polyphase Wireless Power Transfer System for EV Applications

Polyphase wireless power transfer (WPT) systems can achieve much higher surface power densities (kW/m2) and specific power levels (kW/kg) compared to the conventional circular single phase WPT systems. Therefore, polyphase WPT systems can reduce the size, weight, volume, and cost of the WPT systems and can simplify the electric vehicle integration with less demand for space. This study presents the high-performance and compact 100-kW WPT development using polyphase electromagnetic coupling coils with rotating magnetic fields.

Onar, Omer [ORNL] (ORCID:0000000292028857)↗

Resonant mode effects on rotation braking induced by n = 1 resonant magnetic perturbations in the EAST tokamak

Abstract The spectrum effects on toroidal rotation braking, induced by n = 1 resonant magnetic perturbations (RMPs) in the discharges with q 95 = 4.1 and q 95 = 5.1 , are studied in the EAST tokamak. Here n is the toroidal mode number, RMP spectrum is varied by scanning δ ϕ U L , the phase difference between the upper and lower rows of RMP coils. The toroidal rotation changes periodically with the periodic δ ϕ U L scanning and such an effect is stronger in the discharge with lower q 95 = 4.1 . The spectrum dependence of the neoclassical toroidal viscosity (NTV) torque, modeled by NTVTOK based on the magnetic perturbation obtained from MARS-F calculation, agrees well with that of the experimentally observed braking torques in both discharges. The modeled NTV torque is stronger in the discharge with lower q 95 , which also agrees with the observations. The comparisons between the spectrum dependence of the NTV and magnetic perturbations show that the resonant mode of magnetic perturbations near the plasma edge mainly contribute the NTV torque. These agreements between modeling and experiments highlight the capability of NTV theory in explaining the experimental observation in the EAST tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of laser-driven magnetic fields with a continuous wave Faraday rotation diagnostic

Magnetic fields driven by a laser in coil targets were studied for laser energies of ~25 J and two pulse durations of 2.8 ns and 70 ps. Axial magnetic fields in the coils were measured by continuous wave Faraday rotation diagnostics. The diagnostics indicated magnetic fields of 6–14 T in the coil and currents of 10–20 kA. Magnetic fields were compared for similar laser targets, focusing conditions, and laser energies. A 30-times increase in the intensity of the laser beam by reducing the pulse duration resulted in an increase in the magnetic field and current by a factor of 2. The relaxation time of the magnetic pulse was on the sub-microsecond scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Misalignment Tolerant Magnetic Coupler Design and Implementation for Wireless Charging of Unmanned Aerial Vehicles (UAVs)

Wireless power transfer technology is getting more attention these days as a part of expanded battery charging infrastructure and network at a wide range of power levels. Charging Unmanned aerial vehicles (UAVs) is one wireless charging application, and charging their batteries can be challenging because they have short flight times and are frequently charged. For wireless charging of UAVs, the misalignment performance of the magnetic coupler pads is critical because landing on a charging pad at a perfectly aligned position is difficult and can be time-consuming. Different coil shapes and system structures have been proposed in the literature to overcome this challenge. A new design with a high misalignment tolerance is needed; therefore, to fill this gap, a wireless power transfer system has been designed for a 250 W UAV battery charging system with a new magnetic coupler design. A 3D model of the proposed design was created, and finite element simulations were performed. To prove the proposed design, the magnetic coupler prototypes were developed, and experimental results are presented herein. The misalignment tolerance of the proposed system was observed for various rotational positions of the secondary coil, from 0° to 360°. The results demonstrate that DC–DC efficiency varies between 80% and 85% within full 360° rotation of the receiver coil. This result enables the proposed system to address the misalignment problem for wireless charging of UAVs.

UAVs↗