Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

Human ocular torsion during parabolic flights: an analysis with scleral search coil

Rotation of the eyes about the visual axis is known as ocular torsion. A lateral inclination (a "roll") of the head induces ocular torsion in the opposite direction, a response known as ocular counterrolling. For six subjects, we recorded the static (head still) and dynamic (head in oscillatory roll motion) ocular torsion in normal 1 g condition and also during the microgravity and hypergravity periods of parabolic flight, using the electromagnetic scleral search coil technique. With the head still, the direction and magnitude of torsion that occurred in response to microgravity and hypergravity differed substantially from one individual to another, but there was a significant difference in torsional magnitude between the microgravity and hypergravity periods, for all static head positions including the upright position. Under normal 1 g conditions, counterrolling compensated for about 16% of (voluntary) static head roll, while dynamic counterroll was much larger, up to 36% of head roll at 0.55 Hz. With increasing frequency of head oscillation between 0.33 Hz and 0.55 Hz, the gain of counterrolling increased and there was no change in the phase relationship. The gain of dynamic counterroll (in response to voluntary head rolling) was not significantly less in hypogravity, suggesting that on the ground at these frequencies the contribution of gravity and gravity receptors to this reflex is redundant: this reflex is probably driven by the semicircular canals. In some subjects, the torsional displacement in microgravity is accompanied by micro-torsional oscillatory motion.

Non-NASA Center↗

Magnetic Measurements of HL-LHC AUP Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profile. A multi-probe, PCB-based rotating coil and Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. This paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements of $\mathrm{HL-LHC AUP}$ Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profiles. A multi-probe, PCB-based rotating coil and a Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. Here this paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent activities of National Synchrotron Light Source-II Insertion Device Group

Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.

47 OTHER INSTRUMENTATION↗

Uniform rotating field network structure to efficiently package a magnetic bubble domain memory

A unique and compact open coil rotating magnetic field network structure to efficiently package an array of bubble domain devices is disclosed. The field network has a configuration which effectively enables selected bubble domain devices from the array to be driven in a vertical magnetic field and in an independent and uniform horizontal rotating magnetic field. The field network is suitably adapted to minimize undesirable inductance effects, improve capabilities of heat dissipation, and facilitate repair or replacement of a bubble device.

Wolfshagen, Ronald G.↗

Laminar flow effects in the coil planet centrifuge

The coil planet centrifuge designed by Ito employs flow of a single liquid phase, through a rotating coiled tube in a centrifugal force field, to provide a separation of particles based on sedimentation rates. Mathematical solutions are derived for the linear differential equations governing particle behavior in the coil planet centrifuge device. These solutions are then applied as the basis of a model for optimizing particle separations.

Herrmann, F. T.↗

Coil planet centrifugation as a means for small particle separation

The coil planet centrifuge uses a centrifugal force field to provide separation of particles based on differences in sedimentation rates by flow through a rotating coiled tube. Three main separations are considered: (1) single phase fresh sheep and human erythrocytes, (2) single phase fixed heep and human erythrocytes, and (3) electrophoretically enhanced single phase fresh sheep and human erythrocytes.

Herrmann, F. T.↗

Field Harmonic Measurement of High-Gradient Permanent Magnet Quadrupoles for NSLS- II Upgrade

The National Synchrotron Light Source II (NSLS-II) is preparing for a major upgrade based on a new lattice concept, known as “Complex Bend,” to replace its existing double bend achromat (DBA) lattice. Here, this novel lattice will use high-gradient permanent magnet quadrupoles (PMQs) with small apertures in the range of 16–22 mm. A prototype complex bend branch with PMQs has been installed in the NSLS-II linac to evaluate the lattice's performance. An accurate and precise magnetic measurement system is required for field harmonic characterization and magnetic tuning of these PMQs. As part of this project a Rotating-Coil bench, based on a Printed Circuit Board (PCB) coil with a 12 mm diameter, has been configured to measure nine PMQs with bore diameter of 12.7 mm. This PCB coil has an active length of 270 mm, and is able to measure fields up to the 15th harmonic of the main field at a reference radius of 5 mm, while maintaining field quality levels within 10 ppm of the main field. This article presents the PCB coil setup, the harmonic measurement results and their temperature dependencies and repeatability. Simulation results on compensation of undesired multipoles using “IDBuilder”, a genetic algorithm-based optimizer code for magnetic tuning is included for field harmonic corrections.

36 MATERIALS SCIENCE↗

A New Magnetic Measurement System for the Future Low Emittance NSLS-II Storage Ring

A new magnetic measurement system is under construc-tion at BNL for accurate field harmonic measurements and fiducialization of magnets for a future upgrade of the NSLS- II storage ring. The entire storage ring is envi-sioned to be replaced with a new lattice concept, known as Complex Bend, which superimposes dipole and high-gradient quadrupole fields. The magnetic measurement system will use rotating wire and a PCB rotating coil specifically designed for small-aperture (< 15 mm) high gradient magnets. In this paper we describe in detail the mechanical design and the data acquisition hardware and software.

43 PARTICLE ACCELERATORS↗

Risk Reduction Testing of Superconducting Coils for the High Efficiency Megawatt Motor

Second generation high temperature superconducting coils provide a very attractive level of performance for use in the field winding of electric machines for aircraft. Aside from maintaining these coils at cryogenic temperatures, much care must be taken to prevent damaging these relatively fragile materials due to excessive stress. Thermal stresses due to temperature cycling and mechanical stresses due to centrifugal forces are the most critical for the High Efficiency Megawatt Motor. This paper summarizes two test campaigns that were undertaken to reduce the risks posed by these loads. In one campaign, several superconducting coils were fabricated, thermally cycled up to 50~times, and electrically tested in liquid nitrogen to assess the change in superconductivity metrics throughout thermal cycling. In the other campaign, a full-scale superconducting coil was fabricated, a test article was designed to produce a representative stress environment in the coil, the test article and coil were rotated at room temperature up to a speed of 11,800~rpm, and the superconductivity metrics were measured in liquid nitrogen before and after each rotation. The experimental results demonstrate that the superconducting coils manufactured in house can survive both thermal cycling and high speed rotation with no appreciable degradation in superconducting performance.

partially superconducting electric machine↗

Cost-effective Conductor, Cable, and Coils for High Field Rotating Electric Machines

The purpose of the DOE-AMMTO-funded project was to significantly reduce industrial energy intensity through manufacturing innovations. The project focused on superconducting technology for industrial motors to dramatically increase efficiency. The bottleneck in deploying high temperature superconducting (HTS) motors was high cost and low yield of the conductor manufacturing process. The process yield is low because of the defects in the conductor, forcing the manufacturers to cut off defective sections after characterizing each millimeter. Additionally, the piece lengths tend to be low because of the defects. The project tackled the low-yield manufacturing process challenge by devising an innovative method to use defective conductors in bundled cables without losing performance by engineering current sharing among the conductors. The innovation not only lowers the cost of the conductor but also enhances the reliability of HTS motors and other devices to mitigate the defects that might form during the fabrication and operation of the device. With the increasing interest in REBa2Cu3O7-x (REBCO)-coated conductors for various power, energy, and magnet applications, ensuring the reliability of HTS devices is of significant interest. The EERE funding allowed us to make significant progress in understanding the defects in manufactured conductors and the implications of the defects in superconducting electric motors and other superconducting power and energy applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Closed-Loop Optical Rotation Sensor

Optical/electronic system senses rotation and emits pulses at angular increments. System provides linear scale factor across wide range of rotation rates with no lockup at null. Design needs analog-to-digital converters with elaborate signal-processing circuits. Light from laser diode split evenly into two beams propagating in opposite directions around rotation-sensing coil of optical-fiber waveguide. Beams acquire phase difference proportional to rotation rate as they pass through coil. After emerging from coil, beams recombine in beam splitter, and coherent sum led to photodiode.

Goss, Willis C.↗