Formation of a pinched electron beam and an intense x-ray source in radial foil rod-pinch diodes

Low-impedance rod-pinch diode experiments were performed on the MIG generator at Institute of High Current Electronics using an aluminum foil placed between concentric electrodes of a rod-pinch diode. The J × B force accelerates the foil plasma in the axial and radial directions. After the foil plasma is pushed beyond the tip of the rod, a vacuum gap and a pinched electron beam form. The anode and cathode plasmas expansion and the following plasmas sweeping up by the J × B force can result in repetitive gap formations and closures, which are evident in the several successive intense x-ray pulses. A 0.7-mm-size point-like x-ray source was realized using a 1-mm-diameter tungsten rod, tapered to a point over the last 10 mm. The results of experiments show that the foil-shorted rod-pinch diode configuration has the potential to form low-impedance diodes, to shorten x-ray pulse duration and to realize submillimeter spot-size x-ray sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV

The negative polarity rod pinch diode (NPRPD) is a potential millimeter spot size radiography source for high voltage generators (4 to 8 MV) [Cooperstein et al., 'Considerations of rod-pinch diode operation in negative polarity for radiography,' in Proceedings of the 14th IEEE Pulsed Power Conference, 2003, pp. 975-978]. The NPRPD consists of a small diameter (few mm) cylindrical anode extending from the front end of the vacuum cell through a thin annular cathode, held by a central conductor. The polarity has been inverted when compared to the original rod pinch diode [Cooperstein et al., 'Theoretical modeling and experimental characterization of a rod-pinch diode,' Phys. Plasmas 8(10), 4618-4636 (2001)] in order to take advantage from the maximal x-ray emission toward the anode holder at such a voltage [Swanekamp et al., 'Evaluation of self-magnetically pinched diodes up to 10 MV as high resolution flash X-ray sources,' IEEE Trans. Plasma Sci. 32(5), 2004-2016 (2004). We have studied this diode at 4.5 MV, driven by the ASTERIX generator [Raboisson et al., 'ASTERIX, a high intensity X-ray generator,' in Proceedings of the 7th IEEE Pulsed Power Conference, 1989, pp. 567-570.]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode has been modified in order to set up flash a radiographic diode [Etchessahar et al., 'Negative polarity rod pinch diode experiments on the ASTERIX generator,' in Conference Records-Abstracts, 37th IEEE International Conference on Plasma Science, 2010]. The experiments and numerical simulations presented here allowed the observation and analysis of various physical phenomena associated with the diode operation. Also, the influence of several experimental parameters, such as cathode and anode diameters, materials and surface states, was examined. In order to achieve the most comprehensive characterization of the diode, both optical and x-ray diagnostics were used, including high speed multi-image ICCD (intensified CCD) cameras, streak camera, dosimeters, spot size measurements, and pinhole cameras. A set of new results have been obtained through this study. The plasma emission from the anode and cathode surfaces and its expansion appear to be critical for the diode functioning. Also, for the first time, potential sources of diode instability were identified. Finally, an optimal and stable diode configuration was found with the following parameters: 52 rad at 1 m (in Al) and 2.2 mm spot size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental development of rod pinch diode radiographic source using modified KALI 1000 pulsed power system

This paper highlights the development of Rod Pinch (RP) diode for flash X-ray generation as intense radiographic source at BARC, Vizag. The typical RP diode employed used a small diameter (1-2 mm) anode rod extended through a cathode circular aperture (5-6 mm inner diameter). The diode chamber is maintained at 10{sup -5} Torr vacuum by a rotary backed diffusion pump. Experiments performed on a modified Kali 1000 Pulsed Power System (300 kV, 30 kA, 100 ns) were aimed at optimizing the source by maximizing the figure of merit (dose @ 1m in rad/spot diameter{sup 2} in mm{sup 2}) with minimizing of the diode impedance. The typical electron beam parameters used in the experiments are 240-270 kV, 20-25 kA, 100 ns, with a few hundreds of kA/cm{sup 2} current density. The optimization resulted in a configuration with tungsten anode rod having dimensions of a 1.6 mm diameter, tapering extension length 5-25 mm beyond the graphite cathode aperture (Cathode disk ID = 5 mm, thickness = 3mm) to produce a radiation dose of 150-200 milli rad at 1 m distance having an estimated spot-size of 1-2 mm. The radiation emitted from a rod-pinch diode is measured using Thermoluminescence dosimeters (TLDs) at an angular interval of 15° on either side of the rod in horizontal and vertical plane. (author)

43 PARTICLE ACCELERATORS↗

Note: On the generation of sub-300 keV flash-X-rays using rod-pinch diode: An experimental investigation

Generation of flash X-rays (FXRs) at less than 500 keV is described with emphasis on experimental investigation. The pulser is a Tesla transformer-Water transmission line based pulsed power generator operating in double resonance mode to power a rod-pinch diode. The configuration of aspect ratio reported here falls much below the normally reported ratios for the rod-pinch diode operation. Experimental investigation at such low pulsed voltage has revealed “flowering” of the anode tip and “pitting” of the perspex window. A possible explanation in terms of Lorentz body force is discussed rather than the pinch mechanism generally suggested in literature. The experimental investigation for the FXR generation is corroborated by measuring the radiation dose using CaSO{sub 4} (Dy) thermo luminescent dosimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research on pinching characteristics of electron beams emitted from different cathode surfaces of a rod-pinch diode

The particle-in-cell code UNIPIC is used to simulate the working process of a rod-pinch diode and investigate the pinching characteristics of electron beams emitted from different cathode surfaces. The simulation results indicate that the electron beam emitted from the upstream surface pinches better than from other surfaces when all the three surfaces emit electrons. The charge-density deposition on the anode surface peaks at the rod tip while the deposited charge density is approximately uniform over the first 15 mm of the rod before rapidly increasing over the last 3 mm, indicating a large axial extent of electron deposition. For the case of single-surface emission, the pinching quality of the electron beam emitted from the downstream surface is better than those from other surfaces. The charge-density deposition peaks at the rod tip and decreases rapidly off the tip. Based on the relationship of Larmor radius, beam's self-magnetic field, and the spatial current distribution, the above simulation results are analyzed theoretically. The experiments are performed on the inductive voltage adder to examine the simulations. By comparing the axial distribution of the radiation on the anode rod measured with the pinhole camera and the on-axis forward x-ray dose measured with the LiF thermoluminescent detectors, the simulation results are verified. The electron emission suppression method and the impedance change for each case are investigated or discussed in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric study of rod-pinch diode using particle-in-cell simulation

We perform Particle-In-Cell (PIC) simulation of KALI-30 GW pulsed power generator based rod-pinch diode. It is shown that ions emitted from the anode-plasma play a crucial role in diode dynamics. It is found that ions not only help in compensating the space charge due to electron beam, but also lead to enhancement of the local electric field at the side walls of the cathode leading to additional electron emission from the side wall. Electrons emanating from one side wall of the cathode tend to converge at the anode tip. This can be used to design an improved Flash X-ray source. (author)

43 PARTICLE ACCELERATORS↗

Formation of Sub-Millimeter-Size Powerful X-Ray Sources in Low-Impedance Rod-Pinch Diodes

In the paper, experiments on the formation of a low-impedance diode and a focused electron beam as a result of detachment of radial wires, accelerated by the current of a high-current generator, from the rod anode have been described. In the experiments, along with studies of conditions for compact focusing of the electron beam and effective generation of hard x-rays, the shape of the tip of the anode rod is determined at which the x-ray source is point-sized when viewed in the radial direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Pinhole Camera Measurements

The development of the rod pinch diode [1] has led to high-resolution radiography for dynamic events such as explosive tests. Rod pinch diodes use a small diameter anode rod, which extends through the aperture of a cathode plate. Electrons borne off the aperture surface can self-insulate and pinch onto the tip of the rod, creating an intense, small x-ray source (Primary Pinch). This source has been utilized as the main diagnostic on numerous experiments that include high-value, single-shot events. In such applications there is an emphasis on machine reliability, x-ray reproducibility, and x-ray quality [2]. In tests with the baseline rod pinch diode, we have observed that an additional pinch (Secondary Pinch) occurs at the interface near the anode rod and the rod holder. This suggests that stray electrons exist that are not associated with the Primary Pinch. In this paper we present measurements on both pinches using an x-ray pinhole camera. The camera is placed downstream of the Primary Pinch at an angle of 60° with respect to the diode centerline. This diagnostic will be employed to diagnose x-ray reproducibility and quality. In addition, we will investigate the performance of hybrid diodes relating to the formation of the Primary and Secondary Pinches.

X-RAY, pinhole, camera, measurements, rod pinch di↗

Analysis of Cygnus Electrical Signals

The United States initiated the Subcritical Experiment (SCE) program to support a stockpile stewardship mission shortly after the 1992 moratorium on underground nuclear testing was established. Many SCE’s are conducted at the Nevada National Security Site (NNSS) in Nevada. Cygnus is a high-energy radiation generating device (RGD) located and operated at the NNSS and is a primary diagnostic for the SCE program. The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2. From creation of the high power V-I drive to energy transport and X-ray conversion at the rod-pinch diode, the Cygnus machines utilize the following components: oil-filled Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line (CTL), three-cell vacuum induction voltage adder (IVA), and rod-pinch diode. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. Each source has the following X-ray specifications: 1 mm diameter, 4 rad at 1 m, and 50 ns radiation pulse. SCEs are both single-event and high-value; therefore, a high level of performance in reliability and reproducibility are key issues of Cygnus. Prior to executing such a SCE, there are a formidable number of shots (e.g., each of the two Cygnus RGDs charging and discharging properly into the rod-pinch diode load) that must be executed to determine reliability and reproducibility of the Cygnus RGDs. For every shot on Cygnus, voltages and currents along the machine are recorded and analyzed. In this paper we summarize attributes of the voltage and current waveforms at different locations using distribution plots. These distribution plots are used to quantify the reliability and reproducibility for Cygnus. This analysis methodology will provide a standard to trouble shoot results of individual Cygnus shots, and also to monitor long term Cygnus performance. Accordingly, this type of extensive analysis will contribute to optimized Cygnus performance on SCEs.

42 ENGINEERING↗

X-ray Pinhole Camera Measurements

The rod pinch diode is made up of a cathode plate and a small diameter anode rod that extends through the cathode hole. The anode is charged positively. The rod tip is made of a high-z material which is chosen for its bremsstrahlung efficiency. When the diode is pulsed it produces an intense x-ray source used for pulsed radiography. The baseline or reference diode consists of a 0.75 mm diameter Tungsten (W) tapered anode rod which extends 10 mm through a 9 mm diameter 3 mm thick aluminum (Al) aperture. The majority of the current in the electron beam is created on the edges of the cathode aperture and when properly configured, the electrons will self insulate, travel down the extension of the rod, and pinch onto the tip of the rod. In this presentation, performance of hybrid diodes will be compared with the baseline diode.

x-ray, pinhole, camera, measurements↗

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗

K-line spectra from tungsten heated by an intense pulsed electron beam

The plasma-filled rod-pinch diode (PFRP) is an intense source of x-rays ideal for radiography of dense objects. In the PRFP megavoltage electrons from a pulsed discharge concentrate at the pointed end of a 1 mm diameter tapered tungsten rod. Ionization of this plasma might increase the energy of tungsten's K{alpha}{sub 1} fluorescence line, at 59.3182 keV, enough for the difference to be observed by a high-resolution Cauchois transmission crystal spectrograph. When the PFRP's intense hard bremsstrahlung is suppressed by the proper shielding, such an instrument gives excellent fluorescence spectra, albeit with as yet insufficient resolution to see any effect of tungsten's ionization. Higher resolution is possible with various straightforward upgrades that are feasible thanks to the radiation's high intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anodizing of High Electrically Stressed Components

Anodizing creates an aluminum oxide coating that penetrates into the surface as well as builds above the surface of aluminum creating a very hard ceramic-type coating with good dielectric properties. Over time and use, the electrical carrying components (or spools in this case) experience electrical breakdown, yielding undesirable x-ray dosages or failure. The spool is located in the high vacuum region of a rod pinch diode section of an x-ray producing machine. Machine operators have recorded decreases in x-ray dosages over numerous shots using the reusable spool component, and re-anodizing the interior surface of the spool does not provide the expected improvement. A machine operation subject matter expert coated the anodized surface with diffusion pump oil to eliminate electrical breakdown as a temporary fix. It is known that an anodized surface is very porous, and it is because of this porosity that the surface may trap air that becomes a catalyst for electrical breakdown. In this paper we present a solution of mitigating electrical breakdown by oiling. We will also present results of surface anodizing improvements achieved by surface finish preparation and surface sealing. We conclude that oiling the anodized surface and using anodized hot dip sealing processes will have similar results.

Anodizing, sealing, dielectric strength, surface q↗