Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “residential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impacts of non-residential solar on residential adoption decisions

Household decisions to adopt rooftop solar photovoltaics are partly driven by social influence. Previous research on solar adoption influence has focused on influence among residential peers. Here, we expand the framework of solar adoption influence by exploring the influence of non-residential installations on residential adoption decisions. We use staggered differences-in-differences to estimate non-residential influence effects using a large data sample of residential adoptions. We also critically evaluate prevailing frameworks for solar adoption influence. We find that non-residential installations are associated with accelerated residential adoption rates, on the order of 0.4 additional residential adoptions per quarter per non-residential installation. We show that non-residential systems exert a continuous, long-term influence on residential adoption decisions. We explore separate results and influence mechanisms for solar installed on commercial buildings, government buildings, and houses of worship. The results suggest that non-residential solar adopters could serve as partners in policies to “seed” residential adoption in underserved communities.

14 SOLAR ENERGY↗

Evaluating the Impact of Residential Solar Contract Cancellations in the United States

The residential solar photovoltaic (PV) market in the United States is growing, despite frequent customer cancellations. Contract cancellations result in lost time and costs that must be borne by installers, often in the form of higher "soft costs" (i.e., non-equipment costs). These costs are often passed on to customers who successfully install PV systems. To date, few studies have attempted to estimate national cancellation rates or model the impacts on installed system costs. In this report, we utilize an installer-provided dataset of 199,665 residential PV-only projects representing about 10% of U.S. installs each year from 2017-2019. With this data, we evaluate cancellation rates and trends from contract signing to install. Next, by leveraging NREL's soft cost model for residential solar, we estimate installer spending through each phase of the pre-install process. Applying our findings on cancellation timelines and rates, we then estimate the potential cost impacts to successful installs from contract cancellations. Our work suggests that the rates and impacts of contract cancellations have been previously underestimated. Namely, we find that cancellations/unsuccessful project are; more common than previous estimates suggest; occur earlier in project timelines, though a significant number happen even after permit/ATB approvals; and contribute significantly to customer acquisition and other soft costs. We also find that cancellation do not appear to be driven by review delays in permitting and interconnection applications.

14 SOLAR ENERGY↗

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY↗

Smart thermostat data-driven U.S. residential occupancy schedules and development of a U.S. residential occupancy schedule simulator

Occupancy schedule is one of the key inputs in Building Energy Modeling (BEM) to reflect the interaction between buildings and occupants. Over the past decades, standardized occupancy schedules, developed mainly by engineering rule-of-thumb, have been widely used in BEM due to its simplicity and lack of real measured occupancy data. However, the BEM community has recognized their association with uncertainty and reliability in simulation results from BEM. This study introduces representative occupancy schedules in the U.S. residential buildings, derived from a large smart thermostat dataset and time-series K-means clustering, and an open-source tool to generate a stochastic residential occupancy schedule. Over 90,000 residential occupancy schedules were estimated from the ecobee Donate Your Data dataset. Then, the representative occupancy schedules were identified through clustering. This study further investigated the impacts of three parameters (day, house type, and state) on residential occupancy schedules. Then, a tool, the Residential Occupancy Schedule Simulator (ROSS), is developed using the representative occupancy schedules derived in this study. Details of this tool are presented in this paper. In conclusion, the derived representative occupancy schedules and the ROSS tool can help improve the energy modeling of residential buildings.

42 ENGINEERING↗

Incorporating Residential Smart Electric Vehicle Charging in Home Energy Management Systems

Electric vehicles (EVs) are expected to drastically increase residential electricity consumption and could provide a significant source of flexible demand. Aggregating smart EV charge controllers with other smart home devices through a home energy management system can lead to more optimal outcomes that benefit homeowners, utilities, and grid operators. Control strategies should consider occupant convenience by accounting for the need for fully charged EVs near the EV departure time. In this paper, we develop an EV charging framework that accounts for occupant convenience using OCHRE, a residential energy model, and foresee, a home energy management system. We simulate a community with high EV penetration and show that integrated, smart EV charging reduces peak demand and smooths night-time energy consumption. Simulation results show that the proposed control strategy nearly eliminates peak period EV charging and reduces the daily peak demand from EVs by 23%.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Impact of Control on Availability and Cycling of Residential HVAC in a Real-World Experiment

Demand response is an important emerging part of smart grids and there is a large stream of research from theoretical and modeling perspectives. However, there is relatively little experimental evidence that could help researchers and building operators make informed decisions on best practices for modeling, developing, and deployment of control mechanisms. We contribute to the body of experimental research by providing numerical insights into the role and availability of residential HVAC systems for control. We share the findings on the duration of the cooling cycle, off cycle, and temperature settling time of HVAC systems from data collected from a smart neighborhood located in Atlanta, GA.

cycling↗

Calculating Average Hot Water Mixes of Residential Plumbing Fittings Using the ANSI 301-2019 Hot Water Draw Model and National Residential Data to Estimate Hot Water Use in Showerheads and Lavatory Faucets

Available studies of hot water use percentages may not necessarily be generalized to a national level given regional differences, varying methodological approaches, and limited sample sizes. While some publicly available usage data, reports, and surveys estimate actual household usage, a lack of water use data specific to end uses make more precise savings calculations difficult. Additionally, most hot water draw models tend to focus on overall household use and may not readily estimate lavatory fixture use. However, reviewing more recent studies and standards enables the U.S. Environmental Protection Agency’s WaterSense program to update its estimates for hot water use and consumers’ corresponding energy and monetary savings to better reflect realworld conditions. This report specifically focuses on improving hot water use and savings estimates of lavatory faucets and showerheads. To estimate the hot water use of lavatory faucets and showerheads, we employed the 2015 Residential Energy Consumption Surveys (RECS) microdata alongside the ANSI 301-2019 Hot Water Draw Model. These estimates account for regional differences in hot water use, including regional cold water inlet temperatures. As a result, the refinements presented in this report are more robust, more recent, and better describe the geographic variation than previous inputs used by the WaterSense program. In addition, the approach described in this paper can be updated over time or tailored to regionally specific needs given available inputs. We conclude that hot water percentages for showers and faucets calculated using publicly available national data are close to the percentages found by regional studies and are consistent with household-level models of water use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗