Engineering PapersSearch

SEARCH · Engineering Papers

Results for “relativeHumidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Seasonal delay of Sahelian rainfall driven by an east–west contrast in radiative forcing in idealized CESM experiments

Recent studies suggest the observed seasonal delay of rainfall over the Sahel is mainly driven by anthropogenic aerosol forcing, which features a robust east–west contrasting changes in recent decades, with negative and positive top-of-the-atmosphere shortwave radiative forcing in South and East Asia (SA&EA) and in North America and Europe (NA&EU), respectively. Their individual effects on the Sahel rainfall annual cycle remain unclear. Here, by designing idealized sensitivity experiments based on Community Earth System Model (CESM1.2), we show that both negative radiative forcing over SA&EA and positive radiative forcing over NA&EU contribute to the delayed phase and enhanced amplitude of Sahel rainfall annual cycle. To understand the underlying physical processes, both the convective quasi-equilibrium (CQE) and atmospheric energetic frameworks are utilized. Both frameworks can well explain the seasonal delay in the rainfall annual cycle over the Sahel under the regional radiative forcings, with the CQE framework showing stronger explanatory power. Based on the insights from both frameworks, we conducted a moisture budget analysis and found that the negative radiative forcing over SA&EA causes an anomalous low-level anticyclonic circulation, which transports more moisture to the Sahel. As the anomalous anticyclone is stronger in summer and fall compared to spring, rainfall is delayed in the Sahel. Further, under the influence of the positive radiative forcing over NA&EU, more warming in the northern hemisphere causes northward transport of moisture to the northern tropics associated with the cross-equatorial transport of energy. The moisture transport increases relativehumidity over the Sahel and enhances the effective atmospheric heat capacity that delays the seasonal rainfall.

54 ENVIRONMENTAL SCIENCES

Cleaned 5-Minute Resolution Air Quality and Meteorological Data from Nine TCEQ CAMS Sites in Houston, Texas (Nov 2021 – Oct 2022)

These data encompass 5-minute air monitoring and meteorological observations collected in the greater Houston, Texas metropolitan region, at nine (9) Continuous Ambient Monitoring Stations (CAMS) operated by the Texas Commission on Environmental Quality (TCEQ) between November 1, 2021 and October 31, 2022. The CAMS sites (CAMS 1, 8, 35, 45, 148, 403, 405, 410, and 1052) were chosen because their instrumentation includes measurements of PM2.5. These sites also provide continuous multi-parameter air-quality and meteorological measurements. Particulate matter (PM2.5, PM10) was sampled along with several trace gases, including ozone (O3), nitrogen oxides (NO, NO2, NOx), sulfur dioxide (SO2), and carbon monoxide (CO). The data set also contains standard surface meteorological parameters (temperature, humidity, pressure, wind speed, and wind direction). Several sites also include AutoGC-based measurements of volatile organic compounds (VOCs). Air monitoring instruments deployed at the selected sites comprise the following systems: BAM-1020 or TEOM (PM2.5), Thermo Scientific TEI 49i (O3), TEI 42i (NOx), and AutoGCs (VOCs). This data set is similar to the data included within the houairq5mX1.00 datastream, except for a few additional quality control steps. A systematic data cleaning and verification process was performed on the data set to ensure its quality and preparation for analysis. Removal of non-numeric status flags (e.g., [LIM], [QAS], [SPZ], [CAL], [PMA], [AQI], [SPN], [MAL]) was accomplished by employing rule-based string parsing to extract valid numerical values. Missing entries were set to -9999; however, invalid or anomalous values (e.g., 99999) were retained as originally reported by the TCEQ to preserve data provenance. The time sequence was verified for completeness, removal of duplicates, and uniformity at 5-minute intervals. Column labeling was standardized, and corresponding values were assessed for physical plausibility. All timestamps in the data set were reported in Coordinated Universal Time (UTC) as provided by the TCEQ. Further, the latitude and longitude coordinates were added for each CAMS site. A subset of the data (June 1–September 30, 2022) has been used in the following publication: Subba et al. 2025. “Implications of sea breeze circulations on boundary layer aerosols in the southern coastal Texas region.” EGUsphere 2025: 1–49, https://doi.org/10.5194/egusphere-2025-2659.

latitude

CRGTBSO3 TBS Ozone Data

The Tethered Balloon System (TBS) operated for two weeks during a summer IOP of the CoURAGE campaign. This dataset includes data collected from an En-Sci electrochemical cell (ECC) ozonesonde on the TBS. The ozonesonde was connected to an iMet-4RSB radiosonde, and the overall data collected included ozone, relative humidity, temperature, and altitude. The data from the iMet is the same as that found in the TBSMERGED data product. The TBS also had another instrument (iMet XQ2) that collected meteorological data, which may have more accurate relative humidity (RH) data. This ozonesonde data set is intended to complement the TBSMERGED data product, the CRGTBSO3 surface ozone measurements, and the CoURAGE SWARM ozone lidar (TOLNet) measurements from other locations.

Atmospheric relative humidity