Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The dependence of radius on relative humidity and solute mass at high relative humidities up to and including 100%

This manuscript presents a rigorous examination of the equilibrium radius ratio of hygroscopic aerosol particles that are solution drops of ideal and actual inorganic solutes for a range of solute masses in the relative humidity range 99-100%. Analysis is presented first for ideal solutes over a range of solute masses for different hygroscopicities, providing a theoretical framework for the subsequent analysis of actual solutes. Dimensionless quantities are used to reduce the Kohler equation to one with no free parameters and an approximate solution is presented. Next analysis is presented for three common inorganic solutes of atmospheric importance: sodium chloride, ammonium sulfate, and sulfuric acid, with a range of solute masses considered for each substance. The extent to which non-ideality is important for these solutes over the ranges of relative humidities and solute masses considered is examined. A simple but accurate single-parameter expression is presented for the equilibrium radius ratio as a function of relative humidity that contains the dependenceso on solute mass and composition for these solutes. The accuracy of this expression is quantified and factors that limit this accuracy are discussed. The expression is accurate to within 5% over most of the range of mass-equivalent dry radii from 10 to 250 nm and relative humidities from below 99 up to 100%, over which the equilibrium radius ratio varies by more than a factor of five, and it remains finite at 100% relative humidity. Lastly, measurements of hygroscopic growth of aerosol particles in this relative humidity range are discussed.

54 ENVIRONMENTAL SCIENCES↗

Effects of Porous Carbon Morphology, Agglomerate Structure and Relative Humidity on Local O 2 Transport Resistance

The morphology and ionomer distribution in a polymer electrolyte membrane fuel cell (PEMFC) cathode electrode are quantified with nano-scale resolution X-ray computed tomography (nano-CT). Using the nano-CT data, different shapes, sizes and compositions of agglomerates are extracted. Statistical information from multiple techniques, including transmission electron microscopy (TEM), ultra-small angle X-ray scattering (USAXS), and Brunauer-Emmett-Teller (BET) gas adsorption porosimetry are combined to reconstruct the high surface-area porous carbon (HSC) support, exterior (on the surface of carbon) and interior (inside carbon pores) catalysts, ionomer, and primary pores in the extracted agglomerates. Application of capillary condensation theory to the reconstructed agglomerate structure is shown to accurately represent the experimentally-observed relative humidity (RH) dependence of the electrochemically-active surface area (ECA). Direct numerical simulations show that the high local O 2 transport resistance ( R O 2 ) under dry conditions is mainly associated with the reduced ECA. We demonstrate that the agglomerate shape and size affect R O 2 only if the primary pores are poorly accessible (i.e., capillary-condensed water filled primary pores). We also evaluate the effect of transport to the interior catalyst particles on R O 2 .

agglomerate↗

Assessment of the combination of temperature and relative humidity on kidney stone presentations

Highlights: • Temperature and relative humidity have opposing effects on evaporative water loss. • Wet-bulb temperatures best predicted kidney stone presentations. • Differences in predictive capacity of temperature metrics were greatest in summer. Temperature and relative humidity have opposing effects on evaporative water loss, the likely mediator of the temperature-dependence of nephrolithiasis. However, prior studies considered only dry-bulb temperatures when estimating the temperature-dependence of nephrolithiasis. We used distributed lag non-linear models and repeated 10-fold cross-validation to determine the daily temperature metric and corresponding adjustment for relative humidity that most accurately predicted kidney stone presentations during hot and cold periods in South Carolina from 1997 to 2015. We examined three metrics for wet-bulb temperatures and heat index, both of which measure the combination of temperature and humidity, and for dry-bulb temperatures: (1) daytime mean temperature; (2) 24-h mean temperature; and (3) most extreme 24-h temperature. For models using dry-bulb temperatures, we considered four treatments of relative humidity. Among 188,531 patients who presented with kidney stones, 24-h wet bulb temperature best predicted kidney stone presentation during summer. Mean cross-validated residuals were generally lower in summer for wet-bulb temperatures and heat index than the corresponding dry-bulb temperature metric, regardless of type of adjustment for relative humidity. Those dry-bulb models that additionally adjusted for relative humidity had higher mean residuals than other temperature metrics. The relative risk of kidney stone presentations at the 99th percentile of each temperature metric compared to the respective median temperature in summer months differed by temperature metric and relative humidity adjustment, and ranged from an excess risk of 8–14%. All metrics performed similarly in winter. The combination of temperature and relative humidity determine the risk of kidney stone presentations, particularly during periods of high heat and humidity. These results suggest that metrics that measure moist heat stress should be used to estimate the temperature-dependence of kidney stone presentations, but that the particular metric is relatively unimportant.

54 ENVIRONMENTAL SCIENCES↗

Printed hygroscopic electrodes for low-cost capacitive relative humidity sensors

A capacitive relative humidity sensor includes a first electrode and a second electrode, where at least the one of the electrodes is a water-permeable electrode. The electrodes act in conjunction with a water-sensitive hygroscopic dielectric material. The design enables low-cost and simple fabrication of fast-responding and stable relative humidity sensors using digital fabrication techniques.

Pierre, Adrien↗

Lung function association with outdoor temperature and relative humidity and its interaction with air pollution in the elderly

Highlights: • We studied pulmonary effects of temperature and relative humidity in elderly. • Temperature and relative humidity were associated with decreased FEV1 and FVC. • The lag structure suggested that acute effects may last several days. • Effects of temperature and relative humidity were stronger on FVC than on FEV1. • Effects of temperature and relative humidity were amplified by black carbon exposure. While the effects of weather variability on cardio-respiratory mortality are well described, research examining the effects on morbidity, especially for vulnerable populations, is warranted. We investigated the associations between lung function and outdoor temperature (T in Celsius degrees (°C)) and relative humidity (RH), in a cohort of elderly men, the Normative Aging Study. Our study included 1103 participants whose forced vital capacity (FVC), forced expiratory volume in one second (FEV{sub 1}), and weather exposures were assessed one to five times during the period 1995–2011 (i.e. 3162 observations). Temperature and relative humidity were measured at one location 4 h to 7 days before lung function tests. We used linear mixed-effects models to examine the associations with outdoor T and RH. A 5-degree increase in the 3-day moving average T was associated with a significant 0.7% decrease (95%CI: −1.24, −0.20) in FVC and a 5% increase in the 7-day moving average RH was associated with a significant 0.2% decrease (95%CI: −0.40, −0.02) in FVC and FEV{sub 1}. The associations with T were greater when combined with higher exposures of black carbon with a 1.6% decrease (95%CI −2.2; −0.9) in FVC and a 1% decrease (95%CI −1.7; −0.4) in FEV{sub 1}. The relationships between T and RH and lung function were linear. No synergistic effect of T and RH was found. Heat and lung function are two predictors of mortality. Our findings suggest that increases in temperature and relative humidity are related to decreases in lung function, and such observations might be amplified by high black carbon levels.

54 ENVIRONMENTAL SCIENCES↗

Hydration of α-UO 3 following storage under controlled conditions of temperature and relative humidity

Changes in chemical speciation of uranium oxides following storage under varied conditions of temperature and relative humidity are valuable for characterizing material provenance. In this study, subsamples of high purity α-UO 3 were stored under four sets of controlled conditions of temperature and relative humidity over several years, and then measured periodically for chemical speciation. Powder X-ray diffraction (XRD) analysis and extended X-ray absorption fine structure spectroscopy confirm hydration of α-UO 3 to a schoepite-like end product following storage under each of the varied storage conditions, but the species formed during exposure to the lower relative humidity and lower temperature condition follows different trends from those formed under the other three storage conditions (high relative humidity with high or low temperatures, and low relative humidity with a high temperature). Thermogravimetry coupled with XRD analysis was carried out to distinguish desorption pathways of water from the hydrated end products. Density functional theory calculations discern changes in the structure of α-UO 3 following incorporation of 1, 2 or 3 H 2 O molecules or 1, 2 or 3 OH groups into the orthorhombic lattice, revealing differences in lattice constants, U–O bond lengths, and U–U distances. The collective results from this analysis are in contrast to analogous studies that report that U 3 O 8 is oxidized and hydrated in air during storage under high relative humidity conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lidar Measurements of Relative Humidity and Ice Supersaturation in the Upper Troposphere

We compute upper tropospheric relative humidity profiles using water vapor profiles measured by an airborne DIAL and a ground-based Raman lidar. LASE water vapor and MTP temperature profiles acquired from the NASA DC-8 aircraft during the recent Pacific Exploratory Mission Tropics B (PEM Tropics B) field mission in the tropical Pacific and the SAGE-III Ozone Loss and Validation Experiment (SOLVE) in the Arctic as well as water vapor profiles derived from the ground-based DOE ARM Southern Great Plains (SGP) CART Raman lidar are used. Comparisons of the lidar water vapor measurements with available in situ measurements show reasonable agreement for water vapor mixing ratios above 0.05 g/kg. Relative humidity frequency distributions computed using LASE data indicate that ice supersaturation occurred about 5-11% of the time when temperatures were below -35 C. While a higher frequency of ice supersaturation was observed during SOLVE, higher peak values of relative humidity were observed during PEM Tropics B. The relative humidity fields associated with cirrus clouds are also examined.

Ferrare, Richard A.↗

Impact of Relative Humidity during Spin-Deposition of Metal Oxide Thin Films from Aqueous Solution Precursors

Relative humidity during the spin-processing of thin film solution precursors is often not controlled or measured, and its effect on film thickness is generally unappreciated. Herein, we report that the relative humidity during spin-processing has a marked impact on the film thickness of amorphous metal oxide (aluminum oxide and lanthanum zirconium oxide) and hafnium oxide-sulfate (HafSOx) thin films deposited from aqueous precursors. In the humidity range studied [20–95% relative humidity (RH)], film thicknesses varied by a factor of nearly 3, and this effect is independent of the metal precursor identity. Our data suggest that film thickness depends linearly on evaporation rate (100 – RH) for all systems studied, suggesting this effect is predominantly due to the unique characteristics of water as a solvent. In situ X-ray reflectivity studies of HafSOx films deposited under different humidities reveal that, while the thickness varies significantly with humidity, the density of the as-deposited films is similar, suggesting that humidity primarily affects the relative amount of material deposited. Because reproducible film thickness is critical for many applications, our data highlight the importance of controlling humidity during spin-processing.

36 MATERIALS SCIENCE↗

Experiments with the Mesoscale Atmospheric Simulation System (MASS) using the synthetic relative humidity

This study is intended to examine the impact of the synthetic relative humidity on the model simulation of mesoscale convective storm environment. The synthetic relative humidity is derived from the National Weather Services surface observations, and non-conventional sources including aircraft, radar, and satellite observations. The latter sources provide the mesoscale data of very high spatial and temporal resolution. The synthetic humidity data is used to complement the National Weather Services rawinsonde observations. It is believed that a realistic representation of initial moisture field in a mesoscale model is critical for the model simulation of thunderstorm development, and the formation of non-convective clouds as well as their effects on the surface energy budget. The impact will be investigated based on a real-data case study using the mesoscale atmospheric simulation system developed by Mesoscale Environmental Simulations Operations, Inc. The mesoscale atmospheric simulation system consists of objective analysis and initialization codes, and the coarse-mesh and fine-mesh dynamic prediction models. Both models are a three dimensional, primitive equation model containing the essential moist physics for simulating and forecasting mesoscale convective processes in the atmosphere. The modeling system is currently implemented at the Applied Meteorology Unit, Kennedy Space Center. Two procedures involving the synthetic relative humidity to define the model initial moisture fields are considered. It is proposed to perform several short-range (approximately 6 hours) comparative coarse-mesh simulation experiments with and without the synthetic data. They are aimed at revealing the model sensitivities should allow us both to refine the specification of the observational requirements, and to develop more accurate and efficient objective analysis schemes. The goal is to advance the MASS (Mesoscal Atmospheric Simulation System) modeling expertise so that the model output can provide reliable guidance for thunderstorm forecasting.

Chang, Chia-Bo↗

Global distributions of upper tropospheric relative humidity derived from SAGE II observations

The global distributions of upper tropospheric relative humidity derived from the archived SAGE II water vapor data set are presented. For both summer and winter months, vertical profiles of zonal mean relative humidity are derived for each of the six 20-deg latitude bands covering 60 deg N - 60 deg S. Some examples of global maps of upper tropospheric relative humidity are shown to illustrate the relationship between moist areas and convective activity.

Chiou, E. W.↗

Observational Relationship between Entrainment Rate and Environmental Relative Humidity and Implications for Convection Parameterization

Entrainment rate is a critical but highly uncertain quantity in convective parameterizations; especially, the effects of environmental relative humidity on entrainment rate are controversial, or even opposite, in different studies. Analysis of aircraft observations of cumuli from the RACORO and RICO field campaigns shows that entrainment rate is positively correlated with relative humidity. Physical analysis shows that higher relative humidity promotes entrainment by reducing buoyancy in the cloud cores and by weakening downdrafts near the cloud cores. The reduced buoyancy in the cloud cores and weakened downdrafts surrounding the cores further reduce updrafts in the cloud cores; the cloud cores with smaller updrafts are more significantly affected by their environment, resulting in larger entrainment rate. The relationship between entrainment rate and relative humidity is consistent with the buoyancy sorting concept widely used in convection parameterizations. The results provide reliable in situ observations to improve parameterizations of entrainment rate.

54 ENVIRONMENTAL SCIENCES↗

Water adsorption on vanadium oxide thin films in ambient relative humidity

Here in this work, ambient pressure x-ray photoelectron spectroscopy (APXPS) is used to study the initial stages of water adsorption on vanadium oxide surfaces. V 2p, O 1s, C 1s, and valence band XPS spectra were collected as a function of relative humidity in a series of isotherm and isobar experiments. Experiments were carried out on two VO 2 thin films on TiO 2 (100) substrates, prepared with different surface cleaning procedures. Hydroxyl and molecular water surface species were identified, with up to 0.5 ML hydroxide present at the minimum relative humidity, and a consistent molecular water adsorption onset occurring around 0.01% relative humidity. The work function was found to increase with increasing relative humidity, suggesting that surface water and hydroxyl species are oriented with the hydrogen atoms directed away from the surface. Changes in the valence band were also observed as a function of relative humidity. The results were similar to those observed in APXPS experiments on other transition metal oxide surfaces, suggesting that H 2 O-OH and H 2 O-H 2 O surface complex formation plays an important role in the oxide wetting process and water dissociation. Compared to polycrystalline vanadium metal, these vanadium oxide films generate less hydroxide and appear to be more favorable for molecular water adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effect of Environmental Relative Humidity on Carbonation and Oxidation in a Cementitious Waste Form - 18448

Cementitious material has been developed and used for the nuclear waste disposal. Cast Stone, a type of cementitious waste form, is considered for solidification and immobilization of part of low activity radioactive waste (LAW) at DOE Hanford Site in Richland, WA. During its life cycle, the waste form, which is produced from Portland cement, fly ash, blast furnace slag and liquid waste, is subject to reaction with carbon dioxide and oxygen, both in gaseous and dissolved form. The reactions may alter the physical and chemical properties of the waste form and thus change its retention ability for the radionuclides. Therefore, understanding the rate and the impact of oxidation and carbonation in the material is important for projecting the long-term performance of Cast Stone. However, the rate of carbonation and oxidation in Cast Stone closely depends on the moisture content in the material, which varies largely with the environmental relative humidity (RH). In this study, experiments are carried out to study the effect of environmental relative humidity on the carbonation and oxidation rate as well as the leaching of the constituents from Cast Stone. Cast Stone samples doped with Cr as a reaction indicator are aged for 16 to 32 weeks under N{sub 2}, air, and 2% CO{sub 2} (in nitrogen) environments with various relative humidities (15%, 40%, 68%, 100%). After aging, samples were tested for the pH-dependent leaching (EPA Method 1313) and mass transfer rate under diffusion-controlled leaching (EPA Method 1315) of constituents. The progress of the carbonation was measured for each condition to determine the rate of carbonation front ingress. The results show that environmental relative humidity strongly influences carbonation and oxidation in Cast Stone; however, the impact is different for the rate of reaction and for the extent of reactions. The former refers to the rate at which the reaction front ingresses, while the latter refers to the fraction of the material reacted. For both carbonation and oxidation, the largest impact of the reactions at the exposure surface is observed at intermediate relative humidity (68%). However, for carbonation, the reaction front evolves more rapidly under drier conditions, with the highest rate observed at 15% RH. As a result, carbonation and oxidation have different degree of impact on the leaching behavior of Cast Stone samples aged under various relative humidities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystal Microbalance Monitors Relative Humidity

Sensor monitors water evaporation in industrial drying processes. Measured adsorption isotherm for instrument essentially linear over entire range of relative humidity. Testing at each temperature setting less than half hour for full relative-humidity range, with estimated frequency response time less than 10 seconds. Used to measure relative humidity of ambient atmosphere near drying paper, food textile fabrics and pulp to optimize water-drying portion of processing cycle.

Yang, L. C.↗