Lidar Measurements of Relative Humidity and Ice Supersaturation in the Upper Troposphere

We compute upper tropospheric relative humidity profiles using water vapor profiles measured by an airborne DIAL and a ground-based Raman lidar. LASE water vapor and MTP temperature profiles acquired from the NASA DC-8 aircraft during the recent Pacific Exploratory Mission Tropics B (PEM Tropics B) field mission in the tropical Pacific and the SAGE-III Ozone Loss and Validation Experiment (SOLVE) in the Arctic as well as water vapor profiles derived from the ground-based DOE ARM Southern Great Plains (SGP) CART Raman lidar are used. Comparisons of the lidar water vapor measurements with available in situ measurements show reasonable agreement for water vapor mixing ratios above 0.05 g/kg. Relative humidity frequency distributions computed using LASE data indicate that ice supersaturation occurred about 5-11% of the time when temperatures were below -35 C. While a higher frequency of ice supersaturation was observed during SOLVE, higher peak values of relative humidity were observed during PEM Tropics B. The relative humidity fields associated with cirrus clouds are also examined.

Ferrare, Richard A.

Experiments with the Mesoscale Atmospheric Simulation System (MASS) using the synthetic relative humidity

This study is intended to examine the impact of the synthetic relative humidity on the model simulation of mesoscale convective storm environment. The synthetic relative humidity is derived from the National Weather Services surface observations, and non-conventional sources including aircraft, radar, and satellite observations. The latter sources provide the mesoscale data of very high spatial and temporal resolution. The synthetic humidity data is used to complement the National Weather Services rawinsonde observations. It is believed that a realistic representation of initial moisture field in a mesoscale model is critical for the model simulation of thunderstorm development, and the formation of non-convective clouds as well as their effects on the surface energy budget. The impact will be investigated based on a real-data case study using the mesoscale atmospheric simulation system developed by Mesoscale Environmental Simulations Operations, Inc. The mesoscale atmospheric simulation system consists of objective analysis and initialization codes, and the coarse-mesh and fine-mesh dynamic prediction models. Both models are a three dimensional, primitive equation model containing the essential moist physics for simulating and forecasting mesoscale convective processes in the atmosphere. The modeling system is currently implemented at the Applied Meteorology Unit, Kennedy Space Center. Two procedures involving the synthetic relative humidity to define the model initial moisture fields are considered. It is proposed to perform several short-range (approximately 6 hours) comparative coarse-mesh simulation experiments with and without the synthetic data. They are aimed at revealing the model sensitivities should allow us both to refine the specification of the observational requirements, and to develop more accurate and efficient objective analysis schemes. The goal is to advance the MASS (Mesoscal Atmospheric Simulation System) modeling expertise so that the model output can provide reliable guidance for thunderstorm forecasting.

Chang, Chia-Bo

Global distributions of upper tropospheric relative humidity derived from SAGE II observations

The global distributions of upper tropospheric relative humidity derived from the archived SAGE II water vapor data set are presented. For both summer and winter months, vertical profiles of zonal mean relative humidity are derived for each of the six 20-deg latitude bands covering 60 deg N - 60 deg S. Some examples of global maps of upper tropospheric relative humidity are shown to illustrate the relationship between moist areas and convective activity.

Chiou, E. W.

Crystal Microbalance Monitors Relative Humidity

Sensor monitors water evaporation in industrial drying processes. Measured adsorption isotherm for instrument essentially linear over entire range of relative humidity. Testing at each temperature setting less than half hour for full relative-humidity range, with estimated frequency response time less than 10 seconds. Used to measure relative humidity of ambient atmosphere near drying paper, food textile fabrics and pulp to optimize water-drying portion of processing cycle.

Yang, L. C.

Relative Humidity Measurement Assurance Program Results

During the summer of 1992, the National Conference of Standards Laboratories sponsored a relative humidity measurement assurance program (RHMAP) whose purpose was to enable each participating center to assess the quality of relative humidity calibrations being performed by their respective standards laboratories. This paper presents the data which was submitted by the participants during the first round of the program and shows the multi-laboratory comparisons of the 20%, 50%, and 80% relative humidity meaurements performed.

Humidity

The aging correlation (RH + t): Relative humidity (%) + temperature (deg C)

An aging correlation between corrosion lifetime, and relative humidity RH (%) and temperature t (C) has been reported in the literature. This aging correlation is a semi-log plot of corrosion lifetime on the log scale versus the interesting summation term RH(%) + t(C) on the linear scale. This empirical correlation was derived from observation of experimental data trends and has been referred to as an experimental law. Using electrical resistivity data of polyvinyl butyral (PVB) measured as a function of relative humidity and temperature, it was found that the electrical resistivity could be expressed as a function of the term RH(%) t(C). Thus, if corrosion is related to leakage current through an organic insulator, which, in turn, is a function of RH and t, then some partial theoretical validity for the correlation is indicated. This article describes the derivation of the term RH(%) t(C) from PVB electrical resistivity data.

Cuddihy, E. F.

Implications of Enhanced Relative Humidity in Cold Tropical Cirrus

In situ measurements of water vapor concentration and temperature in tropical cirrus during the CRYSTAL-FACE and Pre-AVE missions indicate that the steady-state relative humidity within cirrus at T less than 200 K is about 20-30% higher than ice saturation. These measurements challenge the conventional belief, that any water vapor in excess of ice saturation should be depleted by crystal growth given sufficient time. Detailed simulations of thin cirrus near the tropopause indicate that this enhanced steady-state relative humidity increases ice number densities, decreases crystal sizes and extends cloud lifetimes. The areal coverage of thin cirrus in the tropics is increased rather than decreased as indicated by simpler conceptual models. Perhaps most significantly, the increased steady-state H2O saturation mixing ratio over ice in thin cirrus near the tropopause results in about a 0.5-1 ppmv increase in the amount of water that can enter the stratosphere across the tropical tropopause cold trap. Hence, the enhanced steady-state relative humidity in cold cirrus implies that lower tropopause temperatures are required to explain the observed stratospheric water vapor mixing ratios than previously assumed.

Jensen, Eric

Physical Processes Controlling the Spatial Distributions of Relative Humidity in the Tropical Tropopause Layer over the Pacific

The spatial distribution of relative humidity with respect to ice (RHI) in the boreal wintertime tropical tropopause layer (TTL, is asymptotically Equal to 14-18 km) over the Pacific is examined with the measurements provided by the NASA Airborne Tropical TRopopause EXperiment. We also compare the measured RHI distributions with results from a transport and microphysical model driven by meteorological analysis fields. Notable features in the distribution of RHI versus temperature and longitude include (1) the common occurrence of RHI values near ice saturation over the western Pacific in the lower to middle TTL; (2) low RHI values in the lower TTL over the central and eastern Pacific; (3) common occurrence of RHI values following a constant mixing ratio in the middle to upper TTL (temperatures between 190 and 200 K); (4) RHI values typically near ice saturation in the coldest airmasses sampled; and (5) RHI values typically near 100% across the TTL temperature range in air parcels with ozone mixing ratios less than 50 ppbv. We suggest that the typically saturated air in the lower TTL over the western Pacific is likely driven by a combination of the frequent occurrence of deep convection and the predominance of rising motion in this region. The nearly constant water vapor mixing ratios in the middle to upper TTL likely result from the combination of slow ascent (resulting in long residence times) and wave-driven temperature variability. The numerical simulations generally reproduce the observed RHI distribution features, and sensitivity tests further emphasize the strong influence of convective input and vertical motions on TTL relative humidity.

Jensen, Eric J.

The Vertical Structure of Relative Humidity and Ozone in the Tropical Upper Troposphere: Intercomparisons Among In Situ Observations, A-Train Measurements and Large-Scale Models

In situ measurements in the tropics have shown that in regions of active convection, relative humidity with respect to ice in the upper troposphere is typically close to saturation on average, and supersaturations greater than 20% are not uncommon. Balloon soundings with the cryogenic frost point hygrometer (CFH) at Costa Rica during northern summer, for example, show this tendency to be strongest between 11 and 15.5 km (345-360 K potential temperature, or approximately 250-120 hPa). this is the altitude range of deep convective detrainment. Additionally, simultaneous ozonesonde measurements show that stratospheric air (O3 greater than 150 ppbv) can be found as low as approximately 14 km (350 K/150 hPa). In contrast, results from northern winter show a much drier upper troposphere and little penetration of stratospheric air below the tropopause at 17.5 km (approximately 383 K). We show that these results are consistent with in situ measurements from the Measurement of Ozone and water vapor by Airbus In-service airCraft (MOZAIC) program which samples a wider, though still limited, range of tropical locations. To generalize to the tropics as a whole, we compare our insitu results to data from two A-Train satellite instruments, the Atmospheric Infrared Sounder (AIRS) and the Microwave Limb Sounder (MLS) on the Aqua and Aura satellites respectively. Finally, we examine the vertical structure of water vapor, relative humidity and ozone in the NASA Goddard MERRA analysis, an assimilation dataset, and a new version of the GEOS CCM, a free-running chemistry-climate model. We demonstrate that conditional probability distributions of relative humidity and ozone are a sensitive diagnostic for assessing the representation of deep convection and upper troposphere/lower stratosphere mixing processes in large-scale analyses and climate models.

Selkirk, Henry B.

A theoretical index for understanding distinct land relative humidity trends in observations, reanalyses, and models

Land surface relative humidity (RH) is a key variable in the coupled land–atmosphere system that profoundly influences terrestrial hydroclimate and ecosystems. Yet historical changes in land RH are not well understood due to limited observations, biased reanalyses, and the lack of a framework for interpreting RH changes under multiple influencing factors. Here, we show that the spatiotemporal variability of land RH and its distinct historical trends among observations, reanalyses, and Earth system models are captured by a simple index based on the ratio of precipitation (P) to a modified potential evapotranspiration formulated independently of RH (PET°). The index provides a physical calibration of biased land RH in reanalyses and a quantitative framework for interpreting land RH changes. Over 1973–2024, land RH has decreased substantially, owing to the intrinsic rise in PET° with temperature and little increase in land precipitation. Reanalyses overestimate the observed RH decrease, consistent with exaggerated surface warming and precipitation decline. The index captures this coherent bias and enables a calibration using observed precipitation and temperature. Models simulate a wide range of land RH trends, but nearly all runs underrepresent the historical drying. The index captures the model spread and discrepancy and attributes them to contributions of precipitation and PET°. Weaker land RH decreases in models arise mainly from weaker subtropical precipitation declines, linked to muted intensification of subtropical highs and biased subtropical climatology. The model–observation discrepancy is unlikely explained by internal variability, implying model underestimation of forced RH decrease and a drier land future than current projections.

Earth system models

Relative humidity from psychrometric data

Analytical equation for computing relative humidity as function of wet bulb temperature, dry bulb temperature, and atmospheric pressure is suitable for use with calculator or computer. Analytical expressions may be useful for chemical process control systems and building environmental control systems.

Putnam, T. W.

Room temperature degradation of YBa2Cu3O(7-x) superconductors in varying relative humidity environments

An aging study was performed to determine the stability of YBa2Cu3O(7-x) ceramics in humid environments at 20 C. In this study, fired ceramic specimens were exposed to humidity levels ranging from 30.5 to 100 percent for 2-, 4-, and 6-week time intervals. After storage under these conditions, the specimens were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and electrical resistance measurements. At every storage condition evaluated, the fired ceramics were found to interact with H2O present in the surrounding environment, resulting in the decomposition of the YBa2Cu3O(7-x) phase. XRD data showed that BaCO3, CuO, and Y2BaCuO5 were present after aging and that the peak intensities of these impurity phases increased both with increasing humidity level and with increasing time of exposure. Additionally, SEM analyses of the ceramic microstructures after aging revealed the development of needle-like crystallites along the surface of the test specimens after aging. Furthermore, the superconducting transition temperature T(sub c) was found to decrease both with increasing humidity level and with increasing time of exposure. All the specimens aged at 30.5, 66, and 81 percent relative humidity exhibited superconducting transitions above 80 K, although these values were reduced by the exposure to the test conditions. Conversely, the specimens stored in direct contact with water (100 percent relative humidity) exhibited no superconducting transitions.

Hooker, M. W.

Water-absorbing capacitor system for measuring relative humidity

A method and apparatus using a known water-absorbent polymer as a capacitor which is operated at a dc voltage for measuring relative humidity is presented. When formed as a layer between porous electrically-conductive electrodes and operated in an RC oscillator circuit, the oscillator frequency varies inversely with the partial pressure of the moisture to be measured. In a preferred embodiment, the capacitor is formed from Nafion and is operated at a low dc voltage with a resistor as an RC circuit in an RC oscillator. At the low voltage, the leakage current is proper for oscillation over a satisfactory range. The frequency of oscillation varies in an essentially linear fashion with relative humidity which is represented by the moisture being absorbed into the Nafion. The oscillation frequency is detected by a frequency detector.

Laue, Eric G.

A Study of the Effects of Relative Humidity on Small Particle Adhesion to Surfaces

Ambient dust ranging in size from less than one micron up to 140 microns was used as test particles. Relative humidities of 33% to 100% were used to condition test surfaces after loading with the test particles. A 20 psi nitrogen blowoff was used as the removal mechanism to test for particle adhesion. Particles were counted before and after blowoff to determine retention characteristics. Particle adhesion increased drastically as relative humidity increased above 50%. The greatest adhesion changes occurred within the first hour of conditioning time. Data are presented for total particle adhesion, for particles 10 microns and larger, and 50 microns and larger.

Whitfield, W. J.

Effect of Air Temperature and Relative Humidity at Various Fuel-Air Ratios on Exhaust Emissions on a Per-Mode Basis of an AVCO Lycoming 0-320 Diad Light Aircraft Engine: Volume 1: Results and Plotted Data

A carbureted four cylinder air cooled 0-320 DIAD Lycoming aircraft engine was tested to establish the effects of air temperature and humidity at various fuel-air ratios on the exhaust emissions on a per-mode basis. The test conditions include carburetor lean out at air temperatures of 50, 59, 80, and 100 F at relative humidities of 0, 30, 60, and 80 percent. Temperature humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased. Even at a fixed fuel air ratio, the HC emissions increase and the NOx emissions decrease at the higher values of air temperature and humidity.

Skorobatckyi, M.

Effect of air temperature and relative humidity at various fuel-air ratios on exhaust emissions on a per-mode basis of an Avco Lycoming 0-320 DIAD light aircraft engine. Volume 2: Individual data points

A carbureted four cylinder air cooled 0-320 DIAD Lycoming aircraft engine was tested to establish the effects of air temperature and humidity at various fuel-air ratios on the exhaust emissions on a per-mode basis. The test conditions included carburetor lean-out at air temperatures of 50, 59, 80, and 100 F at relative humidities of 0, 30, 60, and 80 percent. Temperature-humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased. Even at a fixed fuel-air ratio, the HC emissions increase and the NOx emissions decrease at the higher values of air temperature and humidity. Volume II contains the data taken at each of the individual test points.

Skorobatckyi, M.

The Relative Humidity of the Atmosphere in the Encasements Containing the Declaration of Independence, the US Constitution (Pages 1 and 4), and the Bill of Rights

In 1951, the four pages of the US Constitution, the Letter of Transmittal, the Bill of Rights and the Declaration of Independence, collectively called the 'Charters of Freedom,' were hermetically sealed individually in glass encasements. The atmosphere in the encasements consisted of a mixture of helium with water vapor at a relative humidity between 25 and 35% at room temperature. In 1998, Margaret Kelly of the National Archives and Records Administration (NARA), contacted Dr. Joel S. Levine at NASA Langley Research Center (LaRC) to request assistance in determining the chemical composition of the atmosphere inside the encasements. Several different Langley learns were assembled to address that request. each using a different measurement technique. This report describes the method and results of one team's relative humidity measurements on encasements containing pages 1 and 4 of the US Constitution, the Bill of Rights, and the Declaration of Independence performed at NARA, College Park. Maryland, on July 23, 2001.

West, James W.