Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receiver synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A source-synchronous filter for uncorrelated receiver traces from a swept-frequency seismic source

We have developed a novel algorithm to reduce noise in signals obtained from swept-frequency sources by removing out-of-band external noise sources and distortion caused from unwanted harmonics. The algorithm is designed to condition nonstationary signals for which traditional frequency-domain methods for removing noise have been less effective. The source synchronous filter (SSF) is a time-varying narrow band filter, which is synchronized with the frequency of the source signal at all times. Because the bandwidth of the filter needs to account for the source-to-receiver propagation delay and the sweep rate, SSF works best with slow sweep rates and moveout-adjusted waveforms to compensate for source-receiver delays. The SSF algorithm was applied to data collected during a field test at the University of California Santa Barbara’s Garner Valley downhole array site in Southern California. At the site, a 45 kN shaker was mounted on top of a one-story structure and swept from 0 to 10 Hz and back over 60 s (producing useful seismic waves greater than 1.6 Hz). The seismic data were captured with small accelerometer and geophone arrays and with a distributed acoustic sensing array, which is a fiber-optic-based technique for the monitoring of elastic waves. The result of the application of SSF on the field data is a set of undistorted and uncorrelated traces that can be used in different applications, such as measuring phase velocities of surface waves or applying convolution operations with the encoder source function to obtain traveltimes. Lastly, the results from the SSF were used with a visual phase alignment tool to facilitate developing dispersion curves and as a prefilter to improve the interpretation of the data.

58 GEOSCIENCES↗

Note: An improved calibration system with phase correction for electronic transformers with digital output

The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Pulsar Based Timing for Grid Synchronization

Existing synchronization systems in the power grid, such as the global positioning system, are susceptible to temporary or permanent failures due to various unpredictable and uncontrollable factors such as cyber-attack and electromagnetic interferences, thus affecting the accuracy and reliability of generated timing signal. In this article, a pulsar astronomy-based timing system is proposed to provide an alternative synchronization signal. Further, this clock will offer significant security improvements to power grid applications, such as a wide-area monitoring system, which depends on a precise timing signal. The hardware and software frameworks are described in detail. First, a high-speed sampling hardware platform is designed to collect signals from radio telescopes. Then a periodic pulse extraction method with three steps is proposed to process the pulsar signal, including polyphase filterbanks, incoherent de-dispersion, and sliding window folding. Lastly, three experiments are conducted to verify the effectiveness of the frameworks. The generated pulsar timing pulse is presented, and the factors affecting its accuracy are also discussed. The analysis results demonstrate that the pulsar signals can provide high-accurate timing pulses for grid synchronization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods and systems of synchronizer selection

A circuit includes a plurality of synchronizers to adapt a signal from a first clock domain to a second clock domain. Each synchronizer of the plurality of synchronizers includes a synchronizer input to receive the signal from the first clock domain and a synchronizer output to provide the signal as adapted to the second clock domain. The circuit also includes a multiplexer (mux) that includes a plurality of mux inputs and a mux output. Each mux input is coupled to the synchronizer output of a respective synchronizer of the plurality of synchronizers. The mux output provides the signal, as adapted to the second clock domain, from the synchronizer output of a selected synchronizer of the plurality of synchronizers.

42 ENGINEERING↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

GPS signal loss in the wide area monitoring system: Prevalence, impact, and solution

The phasor measurement unit (PMUs), equipped with Global Positioning System (GPS) receivers for precise time synchronization, provides measurements of voltage and current phasors at different nodes of the wide area monitoring system. However, GPS receivers are likely to lose satellite signals due to various unpredictable factors. The prevalence of GPS signal loss (GSL) on PMUs is first investigated using real PMU data. The historical GSL events are extracted from a phasor data concentrator (PDC) and FNET/GridEye server. The correlation between GSL and time, spatial location, solar activity are explored via comprehensive statistical analysis. Furthermore, the impact of GSL on phasor measurement accuracy has been studied via experiments. Finally, several potential solutions to mitigate the impact of GSL on PMUs are discussed and compared.

47 OTHER INSTRUMENTATION↗

Synchrophasor measurement method for power systems

A synchrophasor measurement method for a device configured to take synchronized measurements in a power system is provided. The synchrophasor measurement method includes receiving global positioning system (GPS)-synchronized samples of a signal sensed by the device from the power system; determining a level of distortion of the signal; selecting, based on the level of distortion, a computation method, the computation method being one of an improved zero-crossing (IZC) method and an enhanced phase-lock-loop (EPLL) method; performing the selected computation method to determine at least one parameter of the signal at a reporting frequency, which is at least twice a line frequency of the power system; and outputting, at the reporting frequency, the at least one parameter to an operator of the power system to allow the operator to perform at least one of a monitoring and a controlling of at least one element of the power system.

Yao, Wenxuan↗

Integrating Hybrid-Clustering and Localized Regression for Time Synchronization of a Hierarchical Underwater Acoustic Sensor Array

Time synchronization is a critical requirement for the application of underwater acoustic sensor network (UWSN). Although a number of time synchronization protocols have been proposed for UWSN, none of them can be directly applied to autonomous acoustic receivers due to lack of hardware platform to communicate with each other. In this paper, we propose a machine learning-based time synchronization framework for autonomous receiver arrays, using the Juvenile Salmon Acoustic Telemetry System as a case study. The proposed framework consists of array partition and time synchronization. Using detections of receiver attached beacons as input, this framework synchronizes all receiver clocks to a root receiver clock. The framework has been successfully used in a field study at Trevallyn Dam forebay in Tasmania, Australia.

Fu, Tao↗

Noise Radar Approach for Interrogating SAW Sensors Using Software Defined Radio

Passive, wireless surface acoustic wave (SAW) sensor systems can be approached from a radar perspective, where the SAW device is thought of as a cooperative target. Here, this paper investigates the use of a commercial-off-the-shelf software defined radio to interrogate wireless SAW sensors with a randomly generated interrogation pulse. The USRP B200mini is utilized as the transceiver platform with custom field-programmable gate array (FPGA) modifications to generate the random interrogation waveform and provide synchronization and buffering to the received signal. Each transmit sample bit in the FPGA is fed by an independent linear-feedback shift register, which generates pseudo-random I and Q samples for the interrogation pulse. An RF daughterboard has also been developed and integrated with the B200mini to increase the transmit power, provide filtering of the RF signals, and switch a signal antenna between the transmit and receive channels. Radio control and matched filter correlator post-processing are accomplished using Python. Design and implementation details for the FPGA modifications, RF daughterboard, and post-processing are discussed. Lastly, the system is demonstrated by wirelessly interrogating SAW temperature sensors at 915 MHz.

47 OTHER INSTRUMENTATION↗

A simple amplitude decision based symbol timing synchronization method for real-time IMDD-OOFDM systems

A simple amplitude decision based symbol timing synchronization method for real-time IMDD-OOFDM transmission systems is proposed and experimentally evaluated by using directly modulated DFB laser in 25 km SSMF. The experimental results show that the hardware resource consumption of the proposed synchronization technique is only 6% of the total system which can effectively release the computation complexity without sacrificing the synchronization accuracy. Less than 2 samples offset error of synchronization accuracy can be achieved at received optical power as low as − 20 dBm without employing correlation and multiplication operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchronizing data from irregularly sampled sensors

A system and method include receiving a set of sampled measurements for each of multiple sensors, wherein the sampled measurements are at irregular intervals or different rates, re-sampling the sampled measurements of each of the multiple sensors at a higher rate than one of the sensor's set of sampled measurements, and synchronizing the sampled measurements of each of the multiple sensors.

47 OTHER INSTRUMENTATION↗

Low latency asynchronous interface circuits

In one form, a logic circuit includes an asynchronous logic circuit, a synchronous logic circuit, and an interface circuit coupled between the asynchronous logic circuit and the synchronous logic circuit. The asynchronous logic circuit has a plurality of asynchronous outputs for providing a corresponding plurality of asynchronous signals. The synchronous logic circuit has a plurality of synchronous inputs corresponding to the plurality of asynchronous outputs, a stretch input for receiving a stretch signal, and a clock output for providing a clock signal. The synchronous logic circuit provides the clock signal as a periodic signal but prolongs a predetermined state of the clock signal while the stretch signal is active. The asynchronous interface detects whether metastability could occur when latching any of the plurality of the asynchronous outputs of the asynchronous logic circuit using said clock signal, and activates the stretch signal while the metastability could occur.

42 ENGINEERING↗

Event Fanout/Receiver (evfr) v1.0

The event fanout-receiver is an event-based timing system implementation capable of synchronizing (with respect to clock, events and triggers) to an upstream event generator. This can be used in 2 modes: fanout or receiver. the first one receives 1 upstream timing streams and fanouts it to 36. The second one receives and decodes the stream. This has been in use by ALS for many years and this is a similar implementation, but providing a more flexible configuration

Russo, Lucas↗

Systems and methods for synchronizing converter modules

Various examples are directed to a converter system comprising first and second series-connected converter modules and a synchronization circuit. The synchronization circuit may modulate a reference signal onto a carrier signal to generate a synchronization current signal and the synchronization current signal to an output current of the converter system to generate an aggregated output current. A first converter module may receive the aggregated output current from a first current sensor and generate a first reproduced synchronization signal at least in part from the aggregated output current. A first switch control signal for switching at least one switch at the first converter may be generated based at least in part on the first reproduced synchronization signal.

Cox, Robert Williams↗

Detecting faults in turbine generators

Turbine generator faults can be detected by receiving a current signal from the turbine generator, and synchronously sampling the current signal to obtain a set of current signal samples that are evenly spaced in the phase domain, in which phase differences between adjacent current signal samples in the set of current signal samples are substantially the same. The process includes generating a frequency spectrum of the current signal samples, identifying one or more excitations in the frequency spectrum, and detecting a fault in the turbine generator based on the one or more excitations in the frequency spectrum.

Qiao, Wei↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗