Optimizing pink-beam fast X-ray microtomography for multiphaseflow in 3D porous media
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.
Explore the source record for details and available documents.
Abstract With their brilliance and temporal structure, X-ray free-electron laser can unveil atomic-scale details of ultrafast phenomena. Recent progress in split-and-delay optics (SDO), which produces two X-ray pulses with time-delays, offers bright prospects for observing dynamics at the atomic-scale. However, their insufficient pulse energy has limited its application either to phenomena with longer correlation length or to measurement with a fixed delay-time. Here we show that the combination of the SDO and self-seeding of X-rays increases the pulse energy and makes it possible to observe the atomic-scale dynamics in a timescale of picoseconds. We show that the speckle contrast in scattering from water depends on the delay-time as expected. Our results demonstrate the capability of measurement using the SDO with seeded X-rays for resolving the dynamics in temporal and spatial scales that are not accessible by other techniques, opening opportunities for studying the atomic-level dynamics.
Explore the source record for details and available documents.
The detection sensitivity of synchrotron-based X-ray techniques has been largely improved due to the ever-increasing source brightness, which has significantly advanced ex situ and in situ research for energy materials such as lithium-ion batteries. However, the strong beam–material interaction arising from the high beam flux can substantially modify the material structure. The beam-induced parasitic effect inevitably interferes with the intrinsic material property, making the interpretation of the experimental results difficult and requiring comprehensive assessments. Here, we present a quantitative study of the beam effect on an electrode material Ag 2 VO 2 PO 4 using four different X-ray characterization methods with different radiation dose rates. The material system exhibits interesting and reversible radiation-induced thermal and chemical reactions, further evaluated under electron microscopy to illustrate the underlying mechanism. Further, the work will provide a guideline for using synchrotron X-rays to distinguish the intrinsic behavior from extrinsic structure change of materials induced by X-rays.
Abstract Over the past decades, zinc oxide semiconductor and its derivatives have been extensively developed because of its optoelectronic properties. Since ZnO is an intrinsic n-type semiconductor, how to synthesize high-quality p-type ZnO semiconductors and investigate their optoelectronic properties and local chemical structures are important and necessary. In this article, two studies of synthesizing both undoped and phosphorus-doped ZnO nanostructures by hydrothermal method and chemical vapor deposition (CVD) technique are presented. Scanning electron microscopy (SEM) and laboratory X-ray diffraction (XRD) are used to track the surface morphology and the crystalline structure of both undoped and phosphorus doped ZnO nanostructures, respectively. X-ray absorption near edge structures (XANES), X-ray emission spectroscopy (XES) and X-ray excited optical luminescence (XEOL) are also used to determine the local chemical information of both undoped and phosphorus-doped ZnO nano/microstructures such as local symmetry and optical properties. It is found that the phosphorus is successfully doped into the surface of ZnO and substituted the Zn. The phosphorus-doped ZnO products have better crystallinity and less oxygen vacancies on the surface. These two are correlated as one leads to the other. The XEOL results suggest that the average bandgap for undoped and phosphorus doped ZnO is the same, 3.24 eV. The second derivative of the absorption-emission spectra yields the fundamental bandgap for undoped ZnO and phosphorus-doped ZnO is 3.25 eV. The implication of this observation is discussed.
Explore the source record for details and available documents.
Described are time-resolved radioluminescence (TRRL) properties of the Cu(I) cluster Cu4I62– upon pulsed X-ray, β-ray or α-particle excitation. The longer (>2 μs) TRRL component displayed exponential decay comparable to pulsed UV excitation; however, temporal behavior at shorter times indicates that high local excited state density provides an alternative decay channel.
Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.
HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (<10" FWHM) and broad spectral coverage (0.2–80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. With the recent discoveries of over 40 ultra-high-energy gamma-ray sources (detected above 100 TeV) and neutrino emission in the Galactic Plane, we have entered a new era of multi-messenger astrophysics facing the exciting reality of Galactic PeVatrons. In the next decade, as more Galactic PeVatrons and TeV gamma-ray sources are expected to be discovered, the identification of their acceleration and emission mechanisms will be the most pressing issue in both particle and high-energy astrophysics. In this paper, along with its companion papers, we will present that HEX-P is uniquely suited to address important problems in various cosmic-ray accelerators, including Galactic PeVatrons, through investigating synchrotron X-ray emission of TeV–PeV electrons produced by both leptonic and hadronic processes. For Galactic PeVatron candidates and other TeV gamma-ray sources, HEX-P can fill in a large gap in the spectral-energy distributions (SEDs) of many objects observed in radio, soft X-rays, and gamma rays, constraining the maximum energies to which electrons can be accelerated, with implications for the nature of the Galactic PeVatrons and their contributions to the spectrum of Galactic cosmic rays beyond the knee at ~3 PeV. In particular, X-ray observation with HEX-P and TeV observation with CTAO will provide the most powerful multi-messenger diagnostics to identify Galactic PeVatrons and explore a variety of astrophysical shock mechanisms. We present simulations of each class of Galactic TeV–PeV sources, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of Galactic cosmic-ray accelerators. In addition, we discuss HEX-P’s unique and complementary roles to upcoming gamma-ray and neutrino observatories in the 2030s.
HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (<10" FWHM) and broad spectral coverage (0.2–80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. With the recent discoveries of over 40 ultra-high-energy gamma-ray sources (detected above 100 TeV) and neutrino emission in the Galactic Plane, we have entered a new era of multi-messenger astrophysics facing the exciting reality of Galactic PeVatrons. In the next decade, as more Galactic PeVatrons and TeV gamma-ray sources are expected to be discovered, the identification of their acceleration and emission mechanisms will be the most pressing issue in both particle and high-energy astrophysics. In this paper, along with its companion papers, we will present that HEX-P is uniquely suited to address important problems in various cosmic-ray accelerators, including Galactic PeVatrons, through investigating synchrotron X-ray emission of TeV–PeV electrons produced by both leptonic and hadronic processes. For Galactic PeVatron candidates and other TeV gamma-ray sources, HEX-P can fill in a large gap in the spectral-energy distributions (SEDs) of many objects observed in radio, soft X-rays, and gamma rays, constraining the maximum energies to which electrons can be accelerated, with implications for the nature of the Galactic PeVatrons and their contributions to the spectrum of Galactic cosmic rays beyond the knee at ~3 PeV. In particular, X-ray observation with HEX-P and TeV observation with CTAO will provide the most powerful multi-messenger diagnostics to identify Galactic PeVatrons and explore a variety of astrophysical shock mechanisms. We present simulations of each class of Galactic TeV–PeV sources, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of Galactic cosmic-ray accelerators. In addition, we discuss HEX-P’s unique and complementary roles to upcoming gamma-ray and neutrino observatories in the 2030s.
A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.
Background: Reaction rates of radiative capture reactions can play a crucial role in the nucleosynthesis of heavy nuclei in explosive stellar environments. These reaction rates depend strongly on $\gamma$-ray decay widths in the reaction products, which are, for nonresonant capture reactions at high excitation energies, derived from the $\gamma$-ray strength function and the nuclear level density. Recently, the ratio method was applied to primary $\gamma$ rays observed from ($\textit{d, p}$) reactions and nuclear resonance fluorescence measurements to extract the dipole strength in atomic nuclei and to test the generalized Brink-Axel hypothesis. Purpose: The purpose of this work is to apply the ratio method to primary $\gamma$-ray intensities of the 63,65 Cu($\textit{p},\gamma$) reactions to extract $\gamma$-ray strength information on the nuclei 64,66 Zn. Here, the impact of spin distribution, total $\gamma$-ray decay widths, level densities, and width fluctuations on the application of the ratio method will be discussed. Additionally, by comparing the relative $\gamma$-ray strength at different excitation energies, conclusions on the validity of the generalized Brink-Axel hypothesis can be made. Method: The radiative proton capture reaction measurements have been performed at the HORUS $\gamma$-ray spectrometer of the University of Cologne at one excitation energy for each reaction. Primary $\gamma$-ray intensities have been determined by normalizing secondary $\gamma$-ray transitions in two-step cascades using their absolute branching ratio. The ratio method was applied to the measured primary $\gamma$-ray intensities as well as to previous measurements by Erlandsson et al. at different excitation energies. Results: The relative strength function curve for 64 Zn from our measurement shows no significant deviation from the previous measurement at a different excitation energy. The same is true for 66 Zn where both measurements were at almost the same excitation energy. Absolute $\gamma$-strength function values have been obtained by normalizing the relative curves to quasiparticle random phase approximation calculations because of the absence of experimental data in the respective energy region. Conclusion: The generalized Brink-Axel hypothesis, i.e., the independence of the strength function on the excitation energy, seems to hold in the studied energy region and nuclei. The method to obtain primary $\gamma$-ray intensities from two-step cascade spectra was shown to be a valuable and sensitive tool although its uncertainties are connected to the knowledge of the low-energy level scheme of the investigated nucleus. The scaling in the ratio method should be taken with care, because the relative strength is not a simple sum of $f_{E1}$ and $f_{M1}$ but a somewhat complex linear combination dependent on the excitation energy of the nucleus.
Binary systems are a well-established subclass of gamma-ray sources. The high mass X-ray binary pulsar 1A 0535+262 has been considered to be a possible gamma-ray emitter for a long time, although former gamma-ray searches using the Fermi Large Area Telescope (LAT) and VERITAS data resulted in upper limits only. We aim at a deep search for gamma-ray emission and pulsations from 1A 0535+262 using more than 13 yr of Fermi-LAT data. The analysis was performed for both the whole Fermi-LAT data set, as well as for the X-ray outbursts that 1A 0535+262 has experienced since the launch of Fermi. Various X-ray observations have been used to generate the ephemeris for the pulsation search. We also investigate the long-term gamma-ray flux variability and perform orbital phase-resolved analysis for the outbursts. We did not detect any steady or pulsed gamma-ray emission from 1A 0535+262 during the whole Fermi-LAT mission span or its X-ray outbursts. We thus derived the deepest gamma-ray luminosity upper limits to date at the 95% confidence level to be around (2.3–4.7) × 10 32 erg s -1 depending on different spectral indices assumed, which results in a ratio of L γ to L X (2–150 keV) being (1.9–3.9) × 10 -6 .
To understand the X-ray emission of active galactic nuclei (AGNs), we explored the optical-to-X-ray variation correlation of a radio-loud quasar (RLQ) SDSS J121426.52+140258.9 (hereafter J1214+1402) with multi-epoch observations by the Swift and XMM–Newton telescopes. With the historical multiband data, we found that the infrared-to-X-ray flux of RLQ J1214+1402 should not be dominated by the beamed-jet emission. The Swift optical/UV and X-ray light curves showed that J1214+1402 has two optical states, with low flux before 2014 April 8 and high flux after 2014 June 11, but has no significant X-ray variations during the time range between 2007 March 9 and 2014 August 4. This result was supported by the XMM–Newton observations in the time overlapping with Swift. Interestingly, the early XMM–Newton data prior to the Swift time present two unusual emission epochs when J1214+1402 has relatively low optical fluxes but has the brightest X-ray fluxes. The overall independence of optical-to-X-ray variation seems hard to describe by the disc–corona model. With the X-ray spectral fitting, we find that the soft X-ray excess in J1214+1402 appears only during the high optical state when the X-ray emission is at a low state. The soft X-ray excess in J1214+1402 is difficult to explain by an ionized accretion disc; instead, it may be related to the warm corona.
The X-ray and $γ$-ray emission of globular clusters (GCs) is attributed to their large fraction of compact binary systems, especially those with millisecond pulsars (MSPs). We analyse a population of 124 Galactic GCs to investigate how their dynamical properties affect the formation and evolution of compact binary systems and how this can be translated into the clusters’ observed X-ray and γ-ray emission. We use mainly Chandra X-ray Observatory and Fermi Large Area Telescope observations to achieve our goals and start by detecting 39 GCs in γ rays, seven of which are not listed in previous Fermi -LAT catalogs. Additionally, we find that the total number of X-ray sources within a GC and its γ-ray luminosity are linearly correlated with the stellar encounter rate, indicating that compact binary systems are mainly formed via close stellar encounters. We also find an unexpected rise in the number of X-ray sources for GCs with low rates of stellar encounters, suggesting that there is a dynamical threshold where the formation of X-ray sources is dominated by stellar encounters. Furthermore, we use the Heggie-Hills law to find that subsequent stellar encounters in these compact binaries will, on average, make the binaries even harder, with basically no possibility of binary ionization. Finally, we find that all GCs are point-like sources in γ rays, indicating that the MSPs are concentrated in the clusters’ cores, likely due to dynamical friction.