Engineering PapersSearch

SEARCH · Engineering Papers

Results for “random vibration testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Pareto-optimal target definition for multi-axis random vibration testing

In random vibration testing with multiple control channels, existing control laws require specification of a complete spectral density matrix at each control frequency. Spectral density matrices include autospectral densities on the diagonal and cross-spectral densities on the off-diagonal. In practice, the off-diagonal terms are often unknown, and recent vibration testing research has focused on fixing the diagonal and specifying the off-diagonal to minimize the required control energy, subject to a constraint that the target matrix is positive semidefinite. This paper shows that, even with a fixed diagonal, off-diagonal terms strongly affect control residuals. This overlooked effect occurs in both square and rectangular systems. By jointly considering input energy and control residuals, open-loop inputs are derived directly from the diagonal without specifying the off-diagonal terms. Vibration targets that can be used in closed-loop control are then derived using the optimal inputs, with positive semidefinite constraints applied during the derivation. The result is a set of Pareto-optimal control solutions. For each solution in the set, any other possible solution produces greater control error, greater input energy, or both. A balanced solution is selected automatically, though others can be chosen based on test needs. Simulations and experiments show that the proposed method outperforms state-of-the-art energy-minimizing approaches, achieving significant reductions in both control error and input energy.

Autospectral density

Effects of Central Cut Width on the Dynamical Characteristics of Box Assembly Structure

An investigation into the Box Assembly with Removable Component (BARC) structure is conducted by utilizing computational simulations and experimental structural testing in order to determine the complex dynamical responses instigated by the central cut of the system. Because the dynamics of the BARC system is complex, this study focuses primarily on analyzing the behavior of the box assembly (BA) system. The investigation explores the dynamics of the BA system by varying the central cut widths, ranging from a cut as wide as 0.5” cut to a 0.25” cut system, as well as a 0.1” cut and a system with no cut at all. Experimental testing is performed on each system including a free vibration test using an impact hammer to excite and identify the dominant frequencies of each structure. This testing is followed by pseudo-random vibration tests and swept sinusoidal excitation tests to determine the nonlinear aspects of these systems, such as the possible existence of nonlinear softening, hardening, and/or damping. The results show that nonlinear softening and nonlinear damping are present in each system. The no-cut system demonstrated the highest peak frequencies throughout all the tests, being the most rigid structure. The 0.25” cut system was shown to have the highest peak frequencies among all the cut systems in both the finite elemenet analysis (FEA) and impact testing. This trend did not continue, though, in the random and harmonic testing, possibly due to the added stiffness of the test setup with the slip table and stinger. The results show the importance of accurately measuring the central cut width and how possible geometric uncertainties change the overall dynamical behaviors of complex systems, such as natural characteristics, nonlinear responses, coupling of modes, and oscillating amplitudes.

Padilla, Christopher (ORCID:000900033446732X)

DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES

This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.

Hower, Jonathan [Kansas City National Security Cam

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator

Electric dipole polarizability of 58 Ni

The electric dipole strength distribution in 58 Ni between 6 and 20 MeV has been determined from proton inelastic scattering experiments at very forward angles at RCNP, Osaka. The experimental data are rather well reproduced by quasiparticle random-phase approximation calculations including vibration coupling, despite a mild dependence on the adopted Skyrme interaction. They allow an estimate of the experimentally inaccessible high-energy contribution above 20 MeV, leading to an electric dipole polarizability α D ⁡ ( 58 Ni) = 3.48 (31)⁢ fm 3 . This serves as a test case for recent extensions of coupled-cluster calculations with chiral effective field theory interactions to nuclei with two nucleons on top of a closed-shell system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Nuclear Materials Packaging, Transportation, and Systems Analysis Group Software Quality Assurance Plan: ANSYS Mechanical Finite Element Analysis Software Version 2023R1

ANSYS Inc. develops and markets engineering simulation software and services used in the aerospace, automotive, manufacturing, electronics, biomedical, energy, defense, and many other industries. ANSYS is dedicated to engineering simulation and is the world’s leading software provider. ANSYS was founded in 1970 and is headquartered in Canonsburg, Pennsylvania. ANSYS provides an engineering analysis tool combining structural, thermal, computational fluid dynamics, acoustic, and electromagnetic simulation capabilities. ANSYS has two main programs, which use the same solvers: (1) Mechanical APDL (ANSYS Design Parametric Language), a Fortran-based coding platform, and (2) ANSYS Workbench, which uses a graphical user interface to aid in finite element analysis implementation. This plan covers both APDL and Workbench. The ANSYS computer program is a large-scale, multipurpose finite element program that can be used to solve several classes of engineering analyses. The analysis capabilities of ANSYS include the ability to solve static and dynamic structural analyses, steady-state and transient heat transfer problems, mode-frequency and buckling eigenvalue problems, static or time-varying magnetic analyses, and various types of field and coupled-field applications. The program contains many special features that allow nonlinearities or secondary effects such as plasticity, large strain, hyperelasticity, creep, swelling, large deflections, contact, stress stiffening, temperature dependency, material anisotropy, and radiation to be included in the solution. As ANSYS has been developed, other special capabilities such as substructuring, submodeling, random vibration, kinetostatics, kinetodynamics, free convection fluid analysis, acoustics, magnetics, piezoelectrics, coupled-field analysis, and design optimization have been added to the program. These capabilities contribute further to making ANSYS a multipurpose analysis tool for varied engineering disciplines. The ANSYS program has been in commercial use for over 50 years and has been used extensively in the aerospace, automotive, construction, electronic, energy services, manufacturing, nuclear, plastics, oil, and steel industries. Additionally, many consulting firms and hundreds of universities have used ANSYS for analysis, research, and educational purposes. ANSYS is recognized worldwide as one of the most widely used and capable programs of its type. Ansys design analysis software is the first created within a quality system with ISO 9001 certification, the internationally accepted quality standard. Product development, testing, maintenance and support processes also meet the United States Nuclear Regulatory Commission's quality requirements, as they have for nearly four decades. The Quality Assurance Service Agreement is suitable for the customers working in the nuclear industry who need to meet specific federal regulations including 10CRF50 Appendix B and provisions of 10CFR21. ANSYS has retained its original International Organization for Standardization (ISO) 9001 accreditation certificate since1995-05-04, It’s current certificate is valid until 2027-05-29.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

A Vibrational Energy Harvesting Sensor Based on Linear and Rotational Electromechanical Effects

In this investigation, a magnetically coupled double-spring design is presented for harvesting low-level non-stationary random vibrational energy. The sensor relies on multimodal coupling between the translation and rotation of a two-spring magnet and coil system to widen the harvesting bandwidth. Energy methods are used to develop a model to characterize the electromechanical response of the system, the solution of which is obtained using stochastic techniques based on a particle swarm algorithm. This approach provides an efficient method to estimate system parameters that otherwise are difficult or impossible to determine with independent measurements. The experimental results demonstrate agreement with the theoretical predictions over a limited bandwidth. The sensor can effectively harvest non-stationary vibration energy down to 10 -4 g within a limited bandwidth of 130–150 Hz. The sensor prototype has an operational volume of 2.6 cm 3 with a calculated power density of 0.2 W/cm 3 . The sensor’s small size results in a coupling efficiency of approximately 6% across the tested bandwidth.

42 ENGINEERING