Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

42 ENGINEERING↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

47 OTHER INSTRUMENTATION↗

Pareto-optimal target definition for multi-axis random vibration testing

In random vibration testing with multiple control channels, existing control laws require specification of a complete spectral density matrix at each control frequency. Spectral density matrices include autospectral densities on the diagonal and cross-spectral densities on the off-diagonal. In practice, the off-diagonal terms are often unknown, and recent vibration testing research has focused on fixing the diagonal and specifying the off-diagonal to minimize the required control energy, subject to a constraint that the target matrix is positive semidefinite. This paper shows that, even with a fixed diagonal, off-diagonal terms strongly affect control residuals. This overlooked effect occurs in both square and rectangular systems. By jointly considering input energy and control residuals, open-loop inputs are derived directly from the diagonal without specifying the off-diagonal terms. Vibration targets that can be used in closed-loop control are then derived using the optimal inputs, with positive semidefinite constraints applied during the derivation. The result is a set of Pareto-optimal control solutions. For each solution in the set, any other possible solution produces greater control error, greater input energy, or both. A balanced solution is selected automatically, though others can be chosen based on test needs. Simulations and experiments show that the proposed method outperforms state-of-the-art energy-minimizing approaches, achieving significant reductions in both control error and input energy.

Autospectral density↗

Improving convergence of the Matrix Power Control Algorithm for random vibration testing

Herein, this paper describes modifications to the Matrix Power Control Algorithm (MPCA) to improve convergence for Random Vibration Control (RVC) testing. In particular, this paper presents Multiple-Input Multiple-Output (MIMO) implementations of MPCA in simulation and experiment. An Euler–Bernoulli beam model was simulated with applied base excitations and the Box Assembly with Removable Component (BARC) was used in experiment to validate results. The Bayesian optimization package Dragonfly was used to optimize control parameters. Additionally, a moving-average was employed and optimized to improve the measured response feedback for MPCA, reduce the number of averages needed to be taken between control updates, and further improve convergence. The key results of this paper show that the performance of MPCA can be improved by tuning the control parameters and by applying an optimized moving-average. Furthermore, it is demonstrated that convergence can be achieved within 12 drive-frames, which greatly enhances vibration control capability.

42 ENGINEERING↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality x-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)} and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010)]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binarypseudo-random (BPR) gratings and arrays has been suggested and and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer. Here we describe the details of development of binarypseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML testsamples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

36 MATERIALS SCIENCE↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guide to Random Drug Testing

A collector is the person who instructs and assists donors at a collection site and receives the specimen provided by the donor. The collector should maintain his or her original collector training records (i.e., for initial and refresher training). Collection site records must be stored for a minimum of 2 years. Collection records must be stored and disposed of in a manner that ensures donor confidentiality is maintained.

Eisele, Gerhard R.↗

Performance Monitoring Program: Developing Comparative Metrics for Fitness-for-Duty Programs

To comply with U.S. Nuclear Regulatory Commission (NRC) regulations, licensees and entities authorized under Title 10 of the Code of Federal Regulations (CFR) Part 26 Section 26.3 (§ 26.3) are required to have fitness-for-duty (FFD) programs. Under § 26.3, the expectation of these FFD programs is to provide reasonable assurance that individuals who are granted unescorted access to nuclear power reactor protected areas and Category I fuel cycle facility material control areas are trustworthy, will perform their tasks in a reliable manner, are not under the influence of any substance, legal or illegal, that may impair their ability to perform their duties, and are not mentally or physically impaired from any cause that can adversely affect their ability to safely and competently perform their duties. Pacific Northwest National Laboratory (PNNL) was tasked with developing a performance monitoring program to risk inform NRC inspection and policy regarding quantitative FFD performance data. To meet this need, PNNL developed methodologies that could be implemented within a performance monitoring program. Throughout this report, these methodologies are referred to as comparative metrics. The NRC provided PNNL with 2016–2019 data from annual reporting forms and single positive test forms provided by licensees and other entities. For most of the comparative metrics, the analyses required customized processing, such as creating filtering fields, adding data fields and summaries, and joining datasets. The comparative metrics developed include: random testing rate, random policy violation rate, pre-access policy violation rate, subversion attempt rate, and number of policy violations by labor category. The comparative metrics can be used for parsing and visualizing FFD program data and monitoring FFD performance at the labor category, facility, licensee, and industry levels to risk inform NRC inspection and policy with regard to the FFD data currently collected from licensees and other entities that implement Part 26 requirements. Furthermore, these developed comparative metrics allow a more in-depth look at the FFD programs for the industry to discern trends and patterns that may warrant changes at an industry level and to inform policy decisions. These analyses should be refreshed as new FFD data become available.

99 GENERAL AND MISCELLANEOUS↗

Varity

Brief Description for Public Release: Varity is a framework to identify variations in floating-point programs through randomized differential testing. Varity generates random tests that include floating-point operations and compile these tests with different compilers in a system. It also generates random floating-point inputs for the tests. When tests are executed, the results are compared to identify variations in the results. Varity helps users of a system to identify the compilers that produce the most similar results in the system.

Laguna Peralta, Ignacio↗