An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography

2024-03U-JWS01 - Initial Abstract

Abstract for recently approved CRADA joint work statement 2024-03U-JWS01 with University of Nevada Reno. Publication of abstract at time of approval satisfies requirements of DOE O 483.1B.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS

Flow visualization in high-energy-density laboratory plasmas

Flow visualization is often essential for evaluating high-energy-density (HED) laboratory plasmas, examining their dynamics, and assessing design strategies. However, imaging at fine phenomenological flow scales is a major challenge. Here, a zone-plate–based radiography system tailored for applications in HED physics is demonstrated. The burst-mode radiography system combines a dual-flash laser-generated x-ray source, a high-magnification zone plate optic, and a multiple frame hybrid complementary metal-oxide-semiconductor (hCMOS) sensor for image detection. Operating at a magnification of 42 x⁠, a pair of radiographs is measured in rapid succession, each time gated by a 4.75 keV flash of x rays lasting 100 ps. The system achieves a spatial resolution below 3 μm. The potential of this approach for applications in HED physics is exemplified by observing small-scale spike morphologies at a pusher-foam interface impacted by a strong, laser-driven blast wave.

Flow instabilities

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE