Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiography, radiographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Examining astrophysical gas cloud collapse using an optical depth-scaled, x-ray-irradiated, carbon-foam sphere

When stellar radiation interacts with a molecular cloud, the cloud's fate depends on the strength of the incident radiation and the radiation's mean-free-path within the cloud [F. Bertoldi, Astrophys. J. 346, 735–755 (1989)]. Under the right conditions, the radiation compresses the cloud and a star formation may occur. Where and when the stellar formation occurs in the cloud's collapse are open questions. Direct observation of the complete star–cloud lifecycle is nearly impossible due to the immense timescales and distances over which the interaction occurs. Laboratory astrophysics offers a way to investigate such a system by scaling the important astrophysical parameters to the laboratory. This work describes laboratory experiments to study the radiation-driven implosion of clouds, using x rays from a laser-irradiated, thin, gold foil as a surrogate star and a carbon-foam sphere as a surrogate cloud. An optically thick system, theoretically corresponding to a star-forming regime, was selected by choice of the foam density. Gold foil and sphere motions were imaged by x-ray radiography. Radiographic images show the formation of an interface between rarefied gold and carbon plasmas, a shock moving into the sphere, and a blunting of the initial sphere's shape. Measurements show that the shock moved linearly around 64 μm/ns into the sphere, and the gold–carbon interface formed by 2 ns at the sphere edge remained stationary. The deformation of the sphere was driven by the incident radiation and not by mechanical pressures applied by gold plasma. The blunting of the sphere was likely due to the geometric reduction of flux near the sphere's poles. Higher x-ray flux near the sphere's equator caused high compression and a faster shock, which flattened the sphere. We will discuss the results and implications of our observations.

VanDervort, R. W. [University of Michigan 1 , Ann ↗

Optimization of scintillated imaging detectors for MeV X-ray radiography

Radiographic imaging at X-ray energies in the MeV range poses a complex problem. Detection of high energy X-rays depends heavily on the ability of the detection material, in this work the scintillator, to attenuate and ultimately stop the X-ray. Attenuation is more readily achieved by increasing material thickness, however thick scintillators are plagued with relatively high internal scattering, leading to an overall decrease in spatial resolution and image quality.

42 ENGINEERING↗

Irradiation of an enriched uranium (NaCl-UCl 3 ) fuel salt capsule, summary of nondestructive post-irradiation examinations, and solidification modeling

Molten salt reactors (MSRs) are gaining attention due to their potential for safe, carbon-free nuclear energy with reduced waste. However, licensing these reactors is hindered by limited experimental data on fueled salts, both pre- and post-irradiation. Here, the novel Molten-salt Research Temperature-controlled Irradiation (MRTI) vehicle was designed to address knowledge gaps in irradiating enriched‑uranium-bearing salts. The MRTI experiment irradiated 13 cm 3 of UCl₃-NaCl (93 % U-235) salt in the Neutron Radiography (NRAD) Reactor, achieving a burnup of 0.196 GWd/MTU over 390 h. Despite a heater failure, the thermocouple data suggested fission heat kept the salt molten. The MRTI assembly was remotely disassembled for nondestructive post-irradiation examination (PIE), which included precision gamma-ray scanning (PGS) and neutron radiography. Radiograph images showed the location of the salt and the solidification pattern. PGS results provided an early indication that activated materials of construction did not increase in relative intensity in the region of the capsule where the salt was in contact with the material of construction. Additionally, PGS data showed the presence of several gamma emitting fission products, such as Nb-95, Zr-95, Ru-103, Ce-141, and La-140, where Ru-103 had the highest counts at the bottom of the capsule. Computational fluid dynamics modeling supported observations of salt solidification patterns and proved to be a valuable tool to inform PIE activities. The MRTI experiment has thus far provided critical data and lessons learned for fuel salt PIE activities, essential for advancing the technical readiness of MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Workshop on Radiographic Imaging and Applications Research and Development Recommendations for Field Radiography

The Workshop on Radiographic Imaging and Applications (WORIA) brought together subject matter experts from industry, academia, US and UK government agencies, and the national laboratories to provide a forum to liaise and share information between technology developers in government and industry, end users, and mission stakeholder to produce an “expert consensus view” regarding future research directions toward a comprehensive radiography/penetrating imaging portfolio in the Defense Nuclear Nonproliferation Research and Development Near Field Detection Portfolio. The inaugural WORIA was held at the Spallation Neutron Source at Oak Ridge National Laboratory on February 7–9, 2023. The inaugural WORIA meeting focused on field radiography applications, or situations in which a portable imaging system must be brought to an item of interest (rather than the item brought to an imaging facility). This report documents consensus views derived from the meeting and provides research and development recommendations for federal program managers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kraken Imager and Camera Systems

Presentation describes the Kraken imager and camera systems under development for use at the Nevada National Security Site for work conducted by the National Nuclear Security Administration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe Ejecta Diagnostic

Presentation to be given at a Radiography Workshop to be held April 6, 2021 at Los Alamos National Laboratory's LANSCE facility. Presentations are requested to be delivered in advance, by April 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kraken Camera System

Specification sheet for Kraken camera system being developed by NNSS Transformational Diagnostics and Imaging in Los Alamos. Will be shared internally and externally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Design Yields Robust Large-Area Framing Camera

Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow. The NNSS has designed and fielded a new, large-area, gated framing camera called Kraken. The camera design emphasized manufacturability and flexibility by improving imager yield and creating a camera architecture to shorten design cycles. Design strategies and field data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sparse-Data Deep Learning Strategies for Radiographic Non-Destructive Testing

Radiography is an imaging technique used in a variety of applications, such as medical diagnosis, airport security, and nondestructive testing. We present a deep learning system for extracting information from radiographic images. We perform various prediction tasks using our system, including material classification and regression on the dimensions of a given object that is being radiographed. Our system is designed to address the sparse-data issue for radiographic nondestructive testing applications. It uses a radiographic simulation tool for synthetic data augmentation, and it uses transfer learning with a pre-trained convolutional neural network model. Using this system, our preliminary results indicate that the object geometry regression task saw an improvement of 70% in the R-squared value when using a multi-regime model. In addition, we increase the performance of the object material classification tasks by utilizing data from different imaging systems. In particular, using neutron imaging improved the material classification accuracy by 20% when compared to x-ray imaging.

convolutional neural networks↗

Our teams design high-resolution MeV x-ray radiography systems for National security missions [Poster]

The NNSS has been at the forefront of custom high-fidelity x-ray/gamma radiographic imaging solutions that serve our national security for over five decades. Our radiography team utilizes expertise in physics modeling and analysis, along with optical, mechanical, and electrical design, in close collaboration with our customers, to develop imaging methods and capabilities that go beyond their needs. Conceptual designs are developed through R&D efforts to provide solutions for the specific problem at hand. Field systems are designed and built in-house, then qualified utilizing a range of facilities across the National Security Enterprise. Radiographic imaging systems are deployed by our team in the most challenging environments. The NNSS has a strong math and programming team that provides novel on-site image analysis methods that extract crucial information from data returned in field tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗

Using deep machine learning to interpret proton radiography data from a pulsed power experiment

Deep machine learning is used to analyze a proton radiograph from a tin pulsed power experiment and determine density values for each pixel in the image. Two promising convolutional neural network architectures that have proven to be effective for image analysis in other applications are applied to analyze a proton radiograph and find density values. The process of creating a suitable training dataset is described, involving the Lagrangian hydrodynamic model used for simulations of the experiment, the proton radiography forward model to make synthetic images for training, and the manner in which data augmentation is used to expand the resulting image dataset. It is shown that machine learning not only produces a reasonable density field but is also able to predict features in the density field that are suggested by the proton radiograph but not captured by simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model and Standard Operating Procedures Supporting Signal Variation Flow Graph Analysis

This document will describe the principles of the Signal Variation Flow Technique, and the uncertainty models generated using it. We focus on the capture of the variation between the ideal signal and the measured signal. The ideal signal is defined to represent the signal output of a system whose full state behavior is known, with no variation in environment or during operation, and whose photons trajectories are not modified by the object. A CT uncertainty analysis is the result of two main steps. First, the radiography regime extends from the source to the collected image, which is 2D in the case of standard CT. This maps all upstream uncertainties into the variation observed on the radiograph and captures all variation in the physical domain. Second, the reconstruction regime extends from the captured images to the reconstructed 3D image. This regime is purely in the mathematical domain and corrects reconstruction algorithm artifacts/anomalies. The present work focuses on building the model through the radiography regime. The reconstruction regime is expected to be largely a study of algorithmic sensitivity, requiring the definition of a range of standardized tests through which the algorithms would be run. Radiographic variation would then be mapped through reconstruction sensitivities to predict the signal variation in the final image. An incomplete list for the reconstructed image variation output basis includes voxel density, edge blur and length variation, in analogous fashion to the basis functions presented in this work. The signal variation occurs in several forms at the radiograph. These forms are gathered into a complete basis set of functions describing all variation on the radiograph. The scale of each basis function is calculated independently via a specific SVFG. This includes 0D pixel noise (0DI), 0D energy noise (0DE), 1D blur (1DB), 1D length (1DL) or 2D position (2DP). These models are orthogonal in that they each explore a space in the signal variation domain that cannot be reached by the other basis functions. The variation basis functions, and associated SVFG models are split by output dimensionality, a term loosely used for categorization, and explained further below.

42 ENGINEERING↗